• Title/Summary/Keyword: Shear Flow Stress

Search Result 889, Processing Time 0.026 seconds

Numerical study for fluid-structure interaction of blood flow in TPLS (박동형 인공심폐기에서의 혈류의 고체-유체 상호작용에 대한 수치적 연구)

  • Jung G. S.;Seong H. C.;Shim E. B.;Ko H. J.;Min B. G.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.705-706
    • /
    • 2002
  • Hemodynamics of the TPLS(Twin Pulse Life Support System) is numerically investigated to delineate the possibility of hemolysis in blood. Computational method employing finite element algorithm is utilized to solve the blood flow of the sac squeezed by moving actuator. We assume that the blood flow interacts with the sac material which is activated by the rigid body motion of the actuator. Valve dynamics at the ends of the sac is simplified as on/off type motion. We compute the transient viscous flow in the two-dimensional geometry of the blood sac. Incompressible laminar flow is simulated on the assumption of Newtonian fluid. Blood velocity has a step gradient near the throat of the sac formed by the moving actuator. According to the decrease of the gap size of blood passage, the magnitude of shear stress in the blood is dramatically increased. Numerical solutions show that the maximum value of shear stress in the blood flow in TPLS is relatively smaller than that of the roller type ECLS.

  • PDF

Numerical Study of Pulsatile Blood Flow in Stenotic Artery (협착 동맥에서의 맥동 혈류 유동에 대한 수치해석적 연구)

  • Seo, Tae-Won;Buriev, Bahtiyor
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.32 no.11
    • /
    • pp.891-896
    • /
    • 2008
  • In the present computational study, simple stenotic artery models using pulsatile flow condition were investigated. A 1 Hz non-reversing sinusoidal velocity for pulsatile flow was imposed at the flow inlet and the corresponding Womersley number based on the vessel radius is 2.75. The simple stenotic geometries have been used that consist of 25%, 50% and 75% semicircular constriction in a cylindrical tube. In this paper, numerical solutions are presented for a first harmonic oscillatory flow using commercial software ADINA 8.4. As stenosis and Reynolds number increase, the maximum wall shear stress(WSS) increases while the minimum WSS decreases. As the stenotic rate increases, the pressure drop at the throat severely decreases to collapse the artery and plaque. It is found that the fluid mechanical disturbances due to the constriction were highly sensitive with rate of stenosis and Reynolds number. When Reynolds number and stenosis increase, the larger recirculation region exists. In this recirculation region the possibility of plaque attachment is increasingly higher. The present results enhance our understanding of the hemodynamics of a stenotic artery.

An Experimental Study on Flow Characteristics of Turbulent Pulsating Flow in a Curved Duct by Using LDV (LDV에 의한 곡관덕트에서 난류맥동유동의 유동특성에 관한 실험적 연구)

  • Lee, Hong-Gu;Son, Hyeon-Cheol;Lee, Haeng-Nam;Park, Gil-Mun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.11
    • /
    • pp.1561-1568
    • /
    • 2001
  • In the present study, flow characteristics of turbulent pulsating flow in a square-sectional 180$^{\circ}$curved duct were experimentally investigated. The experimental study for air flows in a curved duct are carried out to measure axial velocity profiles, wall shear stress distributions and entrance length in a square-sectional 180$^{\circ}$curved duct by using the Laser Doppler Velocimeter(LDV) system and the data acquisition. Velocity profiles are obtained using the Rotating Machinery Resolver(RMR)and PHASE software in case of turbulent pulsating flow. Finally, it was plotted by the ORIGIN software. The experiment was conducted in seven sections from the inlet (ø = 0$^{\circ}$) to the outlet (ø=l80$^{\circ}$) at 3 0$^{\circ}$intervals of the duct.

Transient rheological probing of PIB/hectorite-nanocomposites

  • Sung, Jun-Hee;Mewis, Jan;Moldenaers, Paula
    • Korea-Australia Rheology Journal
    • /
    • v.20 no.1
    • /
    • pp.27-34
    • /
    • 2008
  • Clay suspensions in liquid polymers exhibit a time-dependent behaviour that includes viscoelastic as well as thixotropic features. Because of the presence of interacting clay platelets, particulate networks can develop, which are broken down during flow and rebuild upon cessation of the flow. Here, the use of thixotropic techniques in probing flow-induced structures in nanocomposites is explored with data on a hectorite-poly(isobutylene) model system. By means of fast stress jump measurements the hydrodynamic contributions to the steady state stresses are determined as well as those caused by the stretching of the clay floes. Flow reversal measurements do not provide a clear indication of flow-induced anisotropy in the present case. The recovery of the clay microstructure upon cessation of flow is followed by means of overshoot and dynamic measurements. The development of a particulate network is detected by the appearance and growth of a low frequency plateau of the storage moduli. The modulus-frequency curves after various rest times collapse onto universal master curves, regardless of the pre-shear history or temperature. The scaling factors for this master curve are the crossover parameters. The crossover moduli are nearly a linear function of the crossover frequency, the relation being identical for recovery after shearing at different shear rates. This function depends, however, on temperature.

Hydrodynamic Effect on the Inhibition for the Flow Accelerated Corrosion of an Elbow

  • Zeng, L.;Zhang, G.A.;Guo, X.P.
    • Corrosion Science and Technology
    • /
    • v.16 no.1
    • /
    • pp.23-30
    • /
    • 2017
  • The inhibition effect of thioureido imidazoline inhibitor (TAI) for flow accelerated corrosion (FAC) at different locations for an X65 carbon steel elbow was studied by array electrode and computational fluid dynamics (CFD) simulations. The distribution of the inhibition efficiency measured by electrochemical impedance spectroscopy (EIS) is in good accordance with the distribution of the hydrodynamic parameters at the elbow. The inhibition efficiencies at the outer wall are higher than those at the inner wall meaning that the lower inhibition efficiency is associated with a higher flow velocity, shear stress, and turbulent kinetic energy at the inner wall of the elbow, as well as secondary flow at the elbow rather than the mass transport of inhibitor molecules. Compared to the static condition, the inhibition efficiency of TAI for FAC was relatively low. It is also due to a drastic turbulence flow and high wall shear stress during the FAC test, which prevents the adsorption of inhibitor and/or damages the adsorbed inhibitor film.

VORTEX SHEAR VELOCITY AND ITS EROSION IN THE SCOUR HOLE

  • Lee, Hong-Sik;Kim, Jin-Hong;Lee, Sam-Hee
    • Water Engineering Research
    • /
    • v.1 no.4
    • /
    • pp.259-266
    • /
    • 2000
  • Scour hole is formed due to the high shear stress of the jet flow at the outlet of a hydraulic structure and vortex erosion occurs in the scour hole. It is important to determine the amount of vortex erosion occurs in the scour hole. It is important to determine the amount of vortex erosion for the design of bed protection. If the vortex erosion continues and reaches to the hydraulic structure, it causes the deformation of the structure itself. To obtain the amount of the vortex erosion, it is necessary to determine the shear velocity of the line vortex in the scour hole was derived by the theory of energy conservation and found to be related to the upstream overflow velocity. The amount of vortex erosion from the scour hole was obtained using entrainment equation for given value of shear velocity. For a design purpose, if the flow velocity at the end of an apron and the properties of bed material are given, the amount of vortex erosion was obtained.

  • PDF

Effects of Kurtosis on the Flow Factors using Average Flow Model (Average Flow Model을 이용한 Kurtosis의 변화에 따른 Flow Factors에 관한 연구)

  • 강민호;구영필;조용주
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.280-288
    • /
    • 2000
  • In this study, flow factors are evaluated in terms of kurtosis using random rough surface generated numerically. As h/$\sigma$become large øx, øy, øfp approach to 1 and øs, øfs to 0 asymptotically regardless of kurtosis. øx, øy, øfp increase with increasing kurtosis in the mixed lubrication regime. øs, øfs is associated with an additional flow transport due to the combined effect of sliding and roughness. As h/$\sigma$ decreases øs, øfs increase up to a certain point, and then decrease toward zero. This behavior can be attributed to the increasing number of contacts in the mixed lubrication regime. øx in the presence of elastic deformation on the surface is larger than øx in the absence of it because local film thickness( h$\_$T/) increases by elastic deformation.

  • PDF

A Study on the Cutting Mechanism and Energy with Saw-toothed Chip (톱니형Chip의 절삭기구와 Energy에 관한 연구)

  • Kim, Hang-Young;Oh, Seok-Hyung;Seo, Nam-Seob
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.4 no.3
    • /
    • pp.44-51
    • /
    • 1987
  • In metal cutting various types of chips are produced in consequence of cutting conditions. Flow-type chips have been studied in most cases because they are easier to be analyzed, but the actual surfaces of chips are not smooth, but crushed. This paper deals with saw-toothed chips, special types of flow-type chips, which have deep concaves and high convexes and sharp angles on the free surface. I tried to establish the theory of saw-toothed chip mechanism through experimental observation, that is, the mathmatical model of the cutting energy and cutting mechanism through the geometrical observation of the chips by using a microscope. The results obtained are as follows: 1. The mechanism of saw-toothed chips is diffenent from that of general flow-chips. 2. In the case of saw-toothed chips, the shear angle must be measured by the hypotenuse angle and the rake angle, and the shear angle is more affected by the rake angle than by the hypotenbuse angle. 3. The friction angle is represented by .beta. = . pi. /4+ .alpha./ sub n/- .phi. which is different from Merchant's equation. 4. The pitch and the slip are greatly influenced by depth of cut, but the influence of the rake angle on it is small. 5. The normal stress and the shear stress on the shear plane decrease with the increase of the cutting depth, and they are almost independent on the variation of a rake angle. 6. The unit friction energy on the tool face, the unit shear energy on the shear plane, and the total cutting energy per unit volume decrease with the increase of rake angle and cutting depth.

  • PDF

Preparation of Semi-solid Fibroin Gel and its Flow Property (반고형 피브로인 단백질 겔의 제조 및 유동특성)

  • Hur, Won;Lee, Shin-Young
    • KSBB Journal
    • /
    • v.24 no.6
    • /
    • pp.563-569
    • /
    • 2009
  • Fibroin is an insoluble structural protein from Bombyx mori. It can be solubilized by dissolving in a hot $CaCl_2$ solution and subsequent dialysis. The aqueous solution is unstable and a transition from aqueous fibroin molecules rich in random coil is undergo to one rich in $\beta$-sheet content, resulting in hydrogelation. However, fibroin gel is so fragile and plastic that its mechanical property should be reformed for various applications. In this report, a semi-solid form of fibroin gel was prepared using glycerol and ethanol and was investigated to analyze their flow properties. A fibroin gel with 80% glycerol showed pseudoplastic and thixotropic properties. The square root of its yield stress varied linearly with fibroin concentration and it extrapolated to zero shear stress at 0.2% fibroin. A fibroin gel with 40% ethanol was shown to be highly thixotropic but its shear-thinning behavior was only observed above a certain level of shear rate. Its pseudoplasticity was restored by a high rate of shear stress.

3-D Flow Analysis of Blood and Blood Substitutes in a Double Branching Model (이중 분지관내 혈액 및 혈액대용유체의 3차원 유동해석)

  • Suh, Sang-Ho;Yoo, Sang-Sin;Roh, Hyung-Woon
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.187-196
    • /
    • 1997
  • The three-dimensional flow analysis using the finite volume method is presented to compare the steady flow characteristics of blood with those of blood substitutes such as water and aqueous polymer solution in an idealized double branching model. The model is used to simlllate the region of the abdominal aorta near the celiac and superior mesenteric branches. Apparent viscosities of blood and the aqueous Separan solution are represented as a function of shear rate by the Carreau model, Water and aqueoiu Separan AP-273 500wppm solution are frequently used as blood substitutes in vitro experiments. Water is a typical Newtonian fluid and blood and Separan solution are non-Newtonian fluids. Flow phenomena such as velocity distribution, pressure variation and wall shear stress distribution of water, blood and polymer solution are quite different due to differences of the rheological characteristics of fluids. Flow phenomena of polymer solution are qualitatively similar to those of blood but the phenomena of water are quite different from those of blood and polymer solution. It is recommended that a lion-Newtonian fluid which exhibits very similar rheological behavior to blood be used in vitro experiments. A non-Newtonian fluid whose rheological characteristics are very similar to those of blood should be used to obtain the meaninylll hemodynamic data for blood flow in vitro experiment and by numerical analysis

  • PDF