• 제목/요약/키워드: Shaft fracture

검색결과 159건 처리시간 0.032초

일체형 스티어링 휠 튜브의 인발공정 설계 (Process design of Monobloc Tube for Steering Input Shaft in cold drawing)

  • 문형준;이상곤;이정환;이영선;이준우;김병민
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 추계학술대회 논문집
    • /
    • pp.431-434
    • /
    • 2005
  • MTS(Monobloc Tube Shaft) has been used for the reduction in weight of shaft and increase in supply of power in the auto industry nowadays. Cold drawing process having high productivity and reduction in the cost has been regarded as the effective technology that is able to substitute for swaging process as forming MTS with constant outer diameter or hollow shaft without surface defects. The objective of this study is not only to find out the optimal process conditions understanding the effect of process parameters on carrying out cold drawing process of SIS(Steering Input Shaft) but also to control the defects resulted from inappropriate process conditions. Therefore, the proper drawing conditions are presented using FE-Analysis and experiment in the paper.

  • PDF

파단방지를 위한 튜브인발공정 최적 금형형상 설계에 관한 연구 (Optimal Die Profile Design in Tube Drawing Process for Prevention of Material Fracture)

  • 이상곤;김상우;이영선;이정환;김병민
    • 한국정밀공학회지
    • /
    • 제23권11호
    • /
    • pp.78-84
    • /
    • 2006
  • The objective of this study is to design the optimal die profile that can prevent material fracture in the tube drawing process for automobile steering input shaft. First, the CDV(Critical Damage Value) of material is obtained by the compression test and FE-analysis. The occurrence of fracture is estimated by the FE-analysis considering the CDV. In order to achieve the objective of this study, optimization technique and FE-analysis are applied. FPS(Flexible Polyhedron Search) method, which is one of the non-gradient optimization techniques often used in engineering, is used to search optimal die profile. The drawing die profile is represented by Bezier-curve to generate all the possible die profile. Using FPS method and FE-analysis the optimal drawing die profile is determined. To verify tile effectiveness of the redesigned optimal die, the tube drawing experiment is performed. In the experimental result, it is possible to produce sound product without material fracture using the redesigned optimal die.

상완골 간부 골절 수술 후 발생한 요골신경 마비에서 시행한 초음파 검사 -증례 보고- (Ultrasonography in Radial Nerve Palsy after Surgery of Humerus Shaft Fracture - Case Report -)

  • 윤형문;고덕환;김형준;남경모;강대명
    • 대한정형외과 초음파학회지
    • /
    • 제5권2호
    • /
    • pp.106-112
    • /
    • 2012
  • 상완골 간부 골절에 대한 수술적 치료 후 발생하는 요골신경 마비는 흔치 않다. 하지만 수술 후 요골신경 손상 정도를 정확히 진단하고 예후를 예측하기가 어려워 수술적 치료를 요할 수 있다. 저자들은 상완골 간부 골절에 관혈적 정복 및 금속판 내고정 수술 후 발생한 요골신경 마비에서 초음파 검사를 시행하여 신경의 연속성을 확인하였다. 이 후 보존적 치료를 시행하여 마비가 회복된 1예를 경험하여 문헌고찰과 함께 보고하는 바이다.

  • PDF

Aseptic Humeral Nonunion: What Went Wrong? What to Do? A Retrospective Analysis of 20 Cases

  • Kim, Jinil;Cho, Jae-Woo;Cho, Won-Tae;Cho, Jun-Min;Kim, Namryeol;Kim, Hak Jun;Oh, Jong-Keon;Kim, Jin-Kak
    • Journal of Trauma and Injury
    • /
    • 제29권4호
    • /
    • pp.129-138
    • /
    • 2016
  • Purpose: Due to recent advances in internal fixation techniques, instrumentation and orthopedic implants there is an increasing number of humeral shaft fracture treated operatively. As a consequence, an increased number nonunion after operative fixation are being referred to our center. The aim of this study is to report the common error during osteosynthesis that may have led to nonunion and present a systematic analytical approach for the management of aseptic humeral shaft nonunion. Methods: In between January 2007 to December 2013, 20 patients with humeral shaft nonunion after operative procedure were treated according to our treatment algorithm. We could analysis x-rays of 12 patients from initial treatment to nonunion. In a subgroup of 12 patients the initial operative procedure were analyzed to determine the error that may have caused nonunion. The following questions were used to examine the cases: 1) Was the fracture biology preserved during the procedure? 2) Does the implant construct have enough stability to allow fracture healing? Results: In 19 out of 20 patients have showed radiographic evidence of union on follow up. One patient has to undergo reoperation because of the technical error with bone graft placement but eventually healed. There were 2 cases wherein the treatment algorithm was not followed. All patients had problems with mechanical stability, and in 13 patients had biologic problems. In the analysis of the initial operative fixation, only one of 12 patients had biologic problems. Conclusion: In our analysis, the common preventable error made during operative fixation of humeral shaft fracture is failure to provide adequate stability for bony union to occur. And with these cases we have demonstrated a systematic analytic management approach that may be used to prevent surgeons from reproducing the same fault and reduce the need for bone grafting.

SNCM220 강 권축의 열처리를 통한 기계적성질 향상 (The Improvement of SNCM220 Winding Shaft in Mechanical Properties by Heat Treatment)

  • 이호성
    • 한국생산제조학회지
    • /
    • 제7권3호
    • /
    • pp.61-67
    • /
    • 1998
  • To find out the reason of fracture, specimens were made from the fractured winding shaft and the mechanical properties as well as their microstructures were investigated. Several heat treatments. including caburizing and tempering were carried out to improve the microstructure, mechanical properties, fatigue crack propagation and rotating bending fatigue characteristics. Through these experiments, following conclusions were obtained. (1) Carburized and tempered specimens showed greatly improved mechanical properties including impact energy, hardness and strength. (2) The fatigue strength of the carburized and tempered specimens increased more than twice than that of the original fractured winding shaft. (3) Crack propagation of the carburized and tempered specimens were faster than that of the original fractured speciens under the same △K. However, it is believed that, in the early stage, the fatigue crack initiation and growth for the carburized and tempered specimen is more difficult.

  • PDF

실험계획법을 이용한 세탁기 플랜지 단면 최적설계 (Optimum Design of Washing Machine Flange using Design of Experiment)

  • 이인수;김병민;김의수
    • 대한기계학회논문집A
    • /
    • 제31권5호
    • /
    • pp.601-608
    • /
    • 2007
  • To meet demand of big capacity and high speed rotation for washing machine, more stress from bending and twisting are complexly loaded onto the shaft supporting the horizontal drum, causing problems in fracture strength and fatigue life. Shafting system is mainly divided into flange and shaft. Flange is located between the drum and shaft, transferring power from the shaft to drum, and acting as a supporter of the back of the drum. Because section of flange has various design factors according to configuration of flange, the optimum conditions can’t be easily determined. Using a design of experiment (DOE), this study was performed investigating the interaction effect between factors as well as the main effect of the each design factor under bending and twist and proposed optimum condition using center composition method among response surface derived from regression equation of simulation-based DOE.

Intramedullary fibula strut bone allograft in a periprosthetic humeral shaft fracture with implant loosening after total elbow arthroplasty

  • Jo, Young-Hoon;Lee, Seung Gun;Kook, Incheol;Lee, Bong Gun
    • Clinics in Shoulder and Elbow
    • /
    • 제23권3호
    • /
    • pp.152-155
    • /
    • 2020
  • Periprosthetic fracture after total elbow replacement surgery is a difficult complication to manage, especially when it comes together with implant loosening. If stem revision and internal fixation of the periprosthetic fracture are performed simultaneously, this would be a very challenging procedure. Most of total elbow replacement implants are cemented type. Cement usage at periprosthetic fracture site may interfere healing of fractured site. Authors underwent internal fixation with use of locking plate and cerclage wire for periprosthetic fracture, allogenous fibular strut bone inserted into the humerus intramedullary canal allowing the fractured site to be more stable without cement usage. At 10-month follow-up, the complete union and good clinical outcome was achieved. We present a novel technique for treating periprosthetic fracture with implant loosening after total elbow replacement surgery, using intramedullary allogenous fibula strut bone graft.

대구지방에서 발생한 개의 골절 (Fractures of the dog in Taegu area)

  • 김대영;장인호
    • 한국임상수의학회지
    • /
    • 제15권1호
    • /
    • pp.222-227
    • /
    • 1998
  • This survey was based on the data of one hundred four dogs with 108 case,T of fracture admitted to the veterinary teaching hospital, College of Veterinary Medicine, Kyungpook National University and 24 private small animal hospitals from January, 1995 to Decemberi 1996. The results were analyzed as following criteria; the distribution of fractures causes of fractured age and sexual distributions month of the most frequencel total body weights presence of communicating external wound, extent of damaged direction of fracture line, location of fracture liner fracture managements fixations methods, fixations methods according to location of fracture. The results of survey were as follow: 1. Main distribution of fracture; radius . ulna (23.1%).2. Causes of fracture; road toraffic accident (39.4 T,). 3. Age; over 24 months (27.9%). 4. Sex; male (53.89)), female (46.2%). 5. Month of the most frequence; July (14.4%) 6. Total body weight: 2-5 kg (45.27)). 7. Presence of communicating external wound; closed fracture (94.2%). 8. Extent of damage; complete fracture (92.6%). 9. Direction of fracture line: comminuted fracture (27.8 To). 10. Location of fracture line; diaphysis (62.0%). 11. Fracture management; open reduction (58.3% ). 12. Fixation methods; not treat (22.2%). 13. Fixation methods according to location of fracture; radius ulna-Kirschner wire fixation (45.5%), femur. shaft-intramedullary pinning (71.4%), pelvis-bone plate (53.3%), metacarpus-not treat, Kirschner wire fixation (each 30.8%).

  • PDF