• 제목/요약/키워드: Shading analysis

검색결과 184건 처리시간 0.031초

A Study on Pattern Recognition to Compute Guidelines Based on Evidence for Ecological Healing Environment at Agha Khan Hospital in Karachi - Focused on Human Thermal Comfort Model (HTCM), for Karachi, using Climate Consultant Program

  • Shaikh, Javaria Manzoor;Park, Jae Seung
    • KIEAE Journal
    • /
    • 제15권2호
    • /
    • pp.27-35
    • /
    • 2015
  • Purpose: Healthcare is on the whole a personal and critical service that consumer's use, whereas hospitalization is as a rule painful, because nature nurtures and Sun Light Luminosity for healthcare settings is considered healing. The performance and design of climate responsive buildings such as AKU requires a detailed study of attributes of climate both at micro as well as macro level. The therapeutic value of contact with nature through window view, greenery and landscape is calculated there. Method: A two prong strategy is been devised for this article, at micro level three typical morphologies are analysed by creating same environment of neighboring building on sun shading chart, radiation and temperature range. Since the analysis of local climate helps to determine the design strategies for hospital Healing Environment which is suitable for Karachi climate; in order to track the macro climatic behaviour, a considerable analysis of psychometrics chart for AKU Karachi are designed on Climate Consultant (CC) and analysed by Machine Learning. Climate Consultant proposes different design strategies suitable for Karachi. And on the other hand time wise illumination sources for clinical area which are then measured on psychrometric chart- according to singular space: multi patient admission, secondly: acute ambulatory ward, and tertiary: multi windowed space according to the mushrabiyah and sky light pattern. Result: Our findings support the hypothesis that windowed wall is 75-80% more healing wall; an accelerated evidence was found for healing at macro level if the form of the hospital is designed according to the climatologically preferences, whereas at micro level: the light resource becomes the staff attentiveness determinant. In Conclusion evidence was provided that the actual form of luminosity results consequently in satisfaction while light entering from several set of windows and other sources might be valued if design according to the healing environment. The data added on the sun shading chart to calculate rays entraining into space in patient room equal to 124416.21 Watts/ meter $m^2$ is calculated as precise healing rate-and is confirmed by questionnaire from patients belonging from each clinical stage having different illnesses.

수상태양광 발전시스템 개발을 위한 적지조사에 관한 연구 (Study on Analysis of Suitable Site for Development of Floating Photovoltaic System)

  • 이성훈;이남형;최형철;김진오
    • 조명전기설비학회논문지
    • /
    • 제26권7호
    • /
    • pp.30-38
    • /
    • 2012
  • Recently, interests in renewable energy have gradually increased. Photovoltaic system of various renewable energy is the most interest in power sources. Nowadays, the market of photovoltaic system is expected to be expanded due to the introduction of RPS(Renewable Portfolio Standard). Floating photovoltaic system is a new power system using the water surface above the dam and reservoir water. Floating photovoltaic system is different from the traditional approach to the development of solar power system causing problems such as environmental degradation. This paper investigates the analysis methods of suitable site for the development of floating photovoltaic system. The A,B,C as the optimal candidates were selected in hap cheon dam. The C is the best suitable site in A,B,C considering the expected power generation. Applied methods have effectively done to develop floated photovoltaic system.

제주도 풍력자원 데이터베이스 KIER-WindJeju (The Wind Resource Database KIER-WindJeju)

  • 김현구;이종남;장문석;경남호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.420-422
    • /
    • 2007
  • In order to support wind power development in Jejudo, the island of winds, the wind resource database KIER-WindJeju has been established by meteor-statistical analysis on met-mast measurements of KIER. The analysis includes tower shading, exposure category, wind profile exponent for wind speed extrapolation to hub height of wind turbine, and correlation matrix between neighboring sites to assist choice of appropriate reference site for long-term correlation. KIER-WindJeju will be provided as an add-on of Google $Earth^{TM}$ and will be used as a guideline of future wind resource assessment in Jejudo.

  • PDF

계통연계형 태양광발전 시스템의 고장유형별 손실 비교분석 (Losses Comparison and Analysis for Fault Modes of Grid-connected Photovoltaic System)

  • 소정훈;고석환;주영철
    • 한국태양에너지학회 논문집
    • /
    • 제37권3호
    • /
    • pp.23-32
    • /
    • 2017
  • This paper presents losses comparison and analysis results for different types of fault modes of grid-connected photovoltaic system generated for long-term operation. The approach of losses comparison and analysis by faults is to identify relationship between measured and estimated values of five loss factors which are quantified from irradiance to system output power. This paper presents the symptom results for faults such as snow, shading, sensor defect, blackout, soiling and so on from three years or more monitored data. These results will indicate that it is useful to develop fault detection and diagnosis tool to enhance capacity factor and save operation and maintenance cost of grid-connected photovoltaic system in the field.

생육 초기의 저온·저일조가 고추의 수량과 품질에 미치는 영향 (Effects of Low Air Temperature and Low Radiation Conditions on Yield and Quality of Hot Pepper at the Early Growth Stage)

  • 위승환;이희주;유인호;장윤아;여경환;안세웅;이진형;김성겸
    • 한국환경과학회지
    • /
    • 제29권10호
    • /
    • pp.989-996
    • /
    • 2020
  • This study was conducted to determine the effect of low temperature and low radiation conditions on the yield and quality of hot pepper at an early growth stage in Korea. In plastic greenhouses, low temperature, low temperature with covered shading treatments were set 17 to 42 days after transplanting. The pepper growing degree days decreased by 5.5% due to the low temperature during the treatment period. Radiation decreased by 74.7% due to the covered shading. After commencing treatments, pepper plant growth decreased with low temperature and low radiation. Analysis of the yield showed that the first harvest was delayed by low radiation. The cumulative yields of 119 days after transplanting were 1,956, 2,171, and 2,018 g/㎡ for control, low temperature, and low temperature with low radiation respectively. Capsaicin and dihydrocapsaicin concentrations in pepper fruit decreased with low temperature and low radiation. To investigate the photosynthetic characteristics according to the treatment, the carbon dioxide reaction curve was analyzed using the biochemical model of photosynthesis. Results showed that the maximum photosynthetic rate, Vcmax (maximum carboxylation rate), J (electric transportation rate), and TPU (triose phosphate utilization) decreased at low temperatures; the maximum photosynthetic rate, J, and gm (dark respiration rate) were reduced by shading. These results indicate that low temperature and low radiation can retard early growth, yield, and quality, but these can also be recovered 119 days after planting. Based on the results, the yield and quality of pepper can recover from abiotic stresses with proper cultivation.

CFD 기법을 이용한 팬 앤 패드 냉방 온실의 온도경사 분석 (Analysis of Temperature Gradients in Greenhouse Equipped with Fan and Pad System by CFD Method)

  • 남상운;;김기성
    • 생물환경조절학회지
    • /
    • 제14권2호
    • /
    • pp.76-82
    • /
    • 2005
  • 팬 앤 패드 시스템은 국내외적으로 온실냉방에서 많이 이용되고 있으며, 그 효율도 매우 높지만 온실 내부의 온도분포가 불균일하고 설치비와 유지비가 많이드는 단점이 있다. 본 연구에서는 팬 앤 패드 시스템의 설계를 위한 자료를 제공할 목적으로 팬 앤 패드시스템 설치온실의 온도분포를 예측하기 위한 CFD 모델을 개발하였다. 개발된 모델은 실험 데이터를 이용하여 검증한 결과 실험치와 예측치가 잘 일치하여 모델의 응용이 가능할 것으로 판단되었다. 개발된 모델을 이용하여 온실 외부의 풍속과 풍향, 팬과 패드의 높이, 환기율에 따른 실내유속, 차광율 및 온실의 길이가 팬 앤 패드 냉방온실의 실내 온도경사에 미치는 영향을 검토하였다. 실내 온도경사를 감소시키기 위하여는 온실 설치 지역의 주풍향을 고려하고 팬과 패드의 높이가 적절해야 할 것으로 판단되었다. 시뮬레이션 결과 높은 환기율과 차광율은 팬 앤 패드 냉방 온실의 온도경사를 감소시키는데 기여할 수 있는 것으로 나타났다. 팬 앤 패드 냉방 온실의 온도를 적정 수준으로 유지시키기 위해서는 외부기상조건, 차광 및 환기율에 따라 온실의 길이를 제한해야 할 것으로 판단되었다. 개발된 CFD모델은 다양한 조건에서 팬 앤 패드 냉방온실의 설계와 평가에 유용한 도구가 될 수 있을 것으로 판단된다.

복잡지형에서의 일사량과 휘도 간의 관계 구명 (Relationship between Solar Radiation in Complex Terrains and Shaded Relief Images)

  • 윤은정;김대준;김진희;강대균;김수옥;김용석
    • 한국농림기상학회지
    • /
    • 제23권4호
    • /
    • pp.283-294
    • /
    • 2021
  • 경사면일사량은 수평면일사량과 해당위치 지형경사도 간의 기하학적 관계인 일사수광비율을 통해 추정할 수 있다. 그러나 이렇게 추정한 일사량은 주변에 햇빛을 차단하는 장애물이 없다는 것을 가정하기 때문에 만약 실제 농사를 짓고 있는 농장 등에 이를 적용할 경우에 지형으로 인한 차광 등의 영향을 충분히 반영하지 못한다. 음영기복도는 태양의 위치와 지형의 기복으로 인한 직달일사의 변이를 밝기(휘도)로 수치화한 격자 형태의 자료로서, 하나의 격자는 가장 어두운 값 0에서 가장 밝은 값 255까지의 값을 갖는다. 본 연구에서는 지형으로 인한 차광효과를 모의하기 위해 30m 해상도의 DEM을 이용하여 연구지역의 음영기복도를 제작하고 휘도 분석을 수행하였다. 연구지역에 설치된 AWS 22개 지점의 기상자료를 수집하여 일조율 80% 이상인 날을 선별하고, 관측일사량과 각 지점의 휘도를 비교하여 휘도가 지형으로 인한 차광효과를 설명할 수 있는지 확인하였다. 분석결과 휘도와 일사량 간에 상관관계가 있는 것을 확인하였으며, 지형의 영향이 큰 지점에서의 직달일사가 시작되는 시점과 끝나는 시점은 태양고도 보다는 휘도와 잘 부합하는 것으로 나타났다. 추가적인 연구를 통해 주변 지형의 영향을 반영한 휘도를 이용한 상세한 일사량 추정이 가능할 것으로 기대된다.

사무소 건물의 외피요소가 냉난방 및 조명에너지 소비에 미치는 영향에 관한 연구 (A Study on the Effect of Envelope Factors on Cooling, Heating and Lighting Energy Consumption in Office Building)

  • 손장희;양인호
    • 조명전기설비학회논문지
    • /
    • 제26권2호
    • /
    • pp.8-17
    • /
    • 2012
  • The objective of this study is to perform an analysis of the heat(heating and cooling) and lighting energy consumption according to the window area ratio and the application of horizontal louver, which is external shading device installed for the purpose of energy savings in office buildings. For this, a building was chosen as a typical example, and the heat and lighting energy consumption was calculated by using the daylight and building energy analysis simulation. The results showed that the total energy consumption, when the lighting control was applied, was reduced by an average of 11.49[%] compared to when there was no lighting control. The smaller the glazing ratio is, the less the total energy consumption is. Also, the application of the horizontal louver increases the total energy consumption under the same condition of glazing ratio.

모델을 이용한 하절기 옥상정원 해석 (The Analysis of Green Roof during the Summer by Numerical Method)

  • 변기홍
    • 한국태양에너지학회 논문집
    • /
    • 제36권5호
    • /
    • pp.51-62
    • /
    • 2016
  • The purpose of this paper is to study the effectiveness of a green roof by simple mathematical model. The developed model simulates a green roof during the summer. The results explain and support the claims in the literature such that effectiveness of a green roof depends on the climate condition, and on the insulation condition of the roof. If insolation can not be reduced more than 60% by the shading effects of a green roof, more active measures than green roof seem necessary. The analysis tools like presented in the paper is necessary especially to consider climate effect, to design, and also to test green roof.

일조해석 프로그램, SunChart 개발에 관한 연구 (A Study on the Development of Sunlight Analysis Program "SunChart")

  • 신우철;장문석;백남춘
    • 한국태양에너지학회 논문집
    • /
    • 제22권4호
    • /
    • pp.10-17
    • /
    • 2002
  • This study aims to develop the analysis tool that assesses the sunlight at any given point of a window or solar collector array shaded by surrounding obstacles. The development of this software, named SunChart, focused to the user-friendliness and the reliability. This SunChart can calculate the solar radiation as well as shading on the certain face. The calculation results by SunChart show by both numerically and graphically and are in a good agreement with ones obtained from "Sunrise Sunset" developed at Korea Astronomy Observatory and from TRNSYS.