• Title/Summary/Keyword: Sewage water source

Search Result 176, Processing Time 0.023 seconds

Determination of Optimum Capacity Rainwater Utilizing Facilities by Analysis of the Water Supply by Land Use Scenario (토지이용 시나리오별 용수공급 분석에 따른 빗물이용시설 최적 용량 결정)

  • Lim, Seok Hwa;Kim, Byung Sung;Ryoo, Kyong Sik;Lee, Sang Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.4
    • /
    • pp.387-397
    • /
    • 2021
  • Most of Korea's agricultural water is supplied by reservoirs, so dependence on them is very high. Accordingly, it is important to reduce this dependence and provide a stable agricultural water supply by utilizing an applicable alternative water source. Therefore, in this work, scenarios for different land uses were constructed, and an optimal water supply plan using rainwater and reused sewage water - which are alternative water sources - was created. A study was also conducted to determine the optimal capacity of a rainwater facility. From the analysis, a stable water supply was achieved in the scenario of maximum utilization of rainwater by changing an existing paddy area to a greenhouse area, and about 0.82 ton of flow capacity was required for 1 mm of rainfall on farms utilizing rainwater. As a result of analyzing the optimal scenario to derive the ratio of the storage capacity per unit water collection area, the rainwater storage capacity determined through MODSIM and the storage capacity determined through actual monitoring showed similar results, about 31 and 32 %, respectively, and the optimal capacity of rainwater facilities was calculated to be about 5,796,000-6,182,400 ton.

Analyses of Synchronous Fluorescence Spectra of Dissolved Organic Matter for Tracing Upstream Pollution Sources in Rivers (상류 오염원 추적을 위한 용존 유기물질 Synchronous 형광스펙트럼 분석 연구)

  • Hur, Jin;Kim, Mi-Kyoung;Park, Sung-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.3
    • /
    • pp.317-324
    • /
    • 2007
  • Fluorescence measurements of dissolved organic matter(DOM) have the superior advantages over other analysis tools for applying to water quality management. A preliminary study was conducted to test the feasibility of applying synchronous fluorescence measurements for tracing and monitoring pollution sources in a small stream located in an upstream area of the Sooyoung watershed in Busan. The water quality of the small stream is affected by leachate from sawdust pile and discharge of untreated sewage. The sampling sites included an upstream site, two pipes discharging untreated sewage, leachate from sawdust, and a downstream site. Of the five field samples, the leachate was distinguished from the other samples by a high peak at a lower wavelength range and a blunt peak at 350nm, suggesting that synchronous fluorescence can be used as a discrimination tool for monitoring the pollution. The efficacy of various indices derived from the spectral features to discriminate the pollution source was tested for well-defined mixture of the sawdust leachate and the upstream stream by comparing (1)the difference between measured values and those predicted based on mass balance and the characteristics of the two samples and (2)the linear correlations between index values and mass ratios of the sample mixtures. Of various discrimination indices selected, fluorescence intensities at 276 nm$({\Delta}\lambda=30nm)$and 347 nm$({\Delta}\lambda=60nm)$ were suggested as promising potential discrimination indices for the sawdust pollution source. Despite the limited number of samples and the study area, this study illustrates the evaluation process that should be followed to develop rapid, low-cost discrimination indices to monitor pollution sources based on end member mixing analyses.

The impact of anthropogenic factors on changes in discharge and quality of water in the Hadano basin, Japan (인위적인 요인이 하천의 유량과 수질변화에 미친 영향 - 일본 하다노 분지를 사례 로 -)

  • ;Yang, Hea-Kun
    • Journal of the Korean Geographical Society
    • /
    • v.30 no.3
    • /
    • pp.242-254
    • /
    • 1995
  • The Hadano Basin is located at a distance of about 70kms and 60kms from Tokyo and Yokohama and lies in the south-west part of the Kanto region in Japan. The basin area, which correspoends to the catchment of the Kaname River, is about areal size of 60.7$\textrm{km}^2$ and extends about length of 8kms in E-W direction and about width of 5kms in N-S direction (Fig.1). The Hadano basin is filled with thick pile of the alluvum from deposits composed of volcanic materials, mostly came from the Hakone Volcano and overlain by Fuji Volcanic ashes. Fluvial deposits form the good aquifer, therefore water resources of Handano City has been largely depending upon the eroundwater. Urbanization and industrialization of the basin has been rapid in the last thirty years, after activation of "Factory Attraction Policy of Hadano City" in 1956. Growth in population and number of factory due to urbanization changed the land-use pattern of the basin rapidly and increased the water demands. Therefore, Hadano City exploited a new source of water supply, and have introduced the prefectureal waterworks since 1976. On the other hand, the rapid urbanization has brought about the pollution of streams in the basin by domestic sewage and industrial waste water. Diffusion rate of sewerage systems in Hadano City is 38% in 1993. In ordcr to examine the impact of anthropogenic factors on river environments, the author took up the change of land-use and diffusion area of sewerage as parameters, and performed field surveys on water discharge and quality. The survey has been made at upstream and downstream of the main stream regularly per month, to get informati ons about the variation of discharge and water quality aiong the stream and its diurnal fluctuation. Annual variation has been analyzed based the data from Hadano City Office. The results are summarized as follows. 1. Stream discharge has been increasing by urbanization (Fig.3). Water quality (C $l^{-10}$ , N $H^{+}$$_{ 4}$-N, BOD) has been improving gradually after the application of sewerage service, yet water pollution load at the lower station has increased than that at the upper one because of the larger anthropogenic discharge volumes (Fig.4). 2. Corrclation coefficient of discharges between upper and lower was 0.81-0.92. Pollutant loads of the R. Kamame after the confluence with R. Kuzuha grew up by 2.4-3.7 times as compared with its upper reaches, and it increased to 3.7-6.9 times after the confluence with the R. Muro (Fig.5). 3. The changes of water quality along the stream can be divided into two groups (Fig.6a). First: water quality of the R. Kaname and R. Shijuhachisse is becoming worse towards the lower reaches because the water from branches are polluted. Second: water quality are improved in the lower where spring and small branch streams supply clear water, for example R. Mizunashi, R. Muro and R. Kuzuha. 4. Measured discharge at the upper station in the R. Shijuhachisse is 0.153㎥/sec, and about 55% of this is recharged until it reaches to the lower point. The R. Mizunashi has a discharge of 1.155㎥/sec at the upper point, is recharged 0.24㎥/sec until the midstream and groundwater spring 0.2㎥/sec at the lower reaches. R. Kuzuha recharged all the mountain runoff (0.2㎥/sec) at the upper reaches. The R. Muro is supplied by many springs and the estimated discharge of spring was 0.47㎥/sec (Fig.6b). 5. Diurmal variations in discharge and water quality are influenced clearly by domestic and industrial waste waters (Fig.7, 8).ed clearly by domestic and industrial waste waters (Fig.7, 8).

  • PDF

Isolation of a Nonylphenol-degrading Microbial Consortium (Nonylphenol 분해 미생물 컨소시엄 균주 개발)

  • Song, Won;Lim, Keun-Sick;Yu, Dae-Ung;Park, Mi-Eun;Jeong, Eun-Tak;Kim, Dong-Myung;Chung, Yong-Hyun;Kim, Young-Mog
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.44 no.4
    • /
    • pp.325-331
    • /
    • 2011
  • Nonylphenol (NP), which is well known as an endocrine disrupter, has been detected widely in untreated sewage or waste water streams. Given the necessity of discovering an eco-friendly method of degrading this toxic organic compound, this study was conducted to isolate NP-degrading microorganisms from the aqueous environment. NP-degrading microbes were isolated through NP-containing enrichment culture. Finally, a microbial consortium, SW-3, capable of degrading NP with high efficiency, was selected from the mixture sample. The microbial consortium SW-3 was able to degrade over 99% of 100 ppm NP in the culture medium for 40 days at $25^{\circ}C$. The microbial consortium SW-3 seemed to utilize NP as a carbon source, since NP was the sole carbon source in the culture medium. In order to isolate the NP-degrading bacterium, we further conducted single colony isolation using the microbial consortium SW-3. Four strains isolated from SW-3 exhibited lower NP-degradation efficiency than that of SW-3, suggesting that NP was degraded by the co-metabolism of the microbial consortium. We suggest that the microbial consortium obtained in this study would be useful in developing an eco-friendly bioremediation technology for NP degradation.

Chemical Characteristics and Pollution of Groundwater in the Ponchon Area, Kwangju (광주, 본촌지역의 지하수의 수화학적 특성과 오염)

  • 양해근;김인수;최희철;김정우
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.4
    • /
    • pp.83-95
    • /
    • 2001
  • In this study, the contaminated status of groundwater under Ponchon Basin, Kwangju-city was analyzed by hydrogeological survey. Though the distribution of groundwater hydraulic head was similar with the ground elevation, the flow system of groundwater was changed due to overpumping in the industrial area. Paddy field and residential area which were located in the north part of the basin had relatively high concentrations of Cl, N $a^{+}$ and N $O_3$$^{[-10]}$ in the groundwater. Southern part of the basin which most industrial area occupied had relatively high concentrations of HC $O_3$, $Ca^{2+}$, $Mg^{2+}$ and Zn. Groundwater was contaminated by C $l^{[-10]}$ and N $O_3$$^{[-10]}$ due to the infiltration of domestic sewage and factory wastewater. In the Cl case, C $l^{[-10]}$ had a tendency of distribution over the water shed along with the contaminated source. The drawdown of groundwater due to overpumping caused more vertical movement of contaminant than lateral movement. If the overpumping continues in the industrial area, the groundwater flow system will be more affected and the groundwater will be lowered in the north part of basin. It is clear that contamination by C $l^{[-10]}$ and N $O_3$$^{[-10]}$ due to domestic sewage and factory wastewater will spread through the whole basin area.rea.

  • PDF

A Study on the Selection of New Town Area Using GIS -in Mongolia - (GIS를 이용한 신도시개발 가능지역 선정 연구 -몽골지역을 대상으로-)

  • Choi, Byoung-Gil;Na, Young-Woo
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.2
    • /
    • pp.273-280
    • /
    • 2010
  • This study aims to research into a plan for the spatial design on the major facilities in new-town region in Mongolia by using the spatial analytical technique in GIS. In case of Mongolian region, the demand for new-town development is rapidly increasing around Ulaanbaatar, where is the capital. On the other hand, the adequately relevant ground or the spatial-design technique is failing to be applied. This study extracted the region available for developing new down by using spatial analytical technique in GIS, and researched into the spatial-design plan for housing complex, filtration plant, sewage disposal plant, power plant, general park, crematory. The housing complex in the targeted region could be known to be adequate to be positioned around watercourse and road. It could be known to be adequate for filtration plant, which is the source of drinking water, to be located in the upper-stream region of a river, which is secured good quality of water, and for sewage disposal plant to be located in the lower-stream region available for minimizing occurrence of contamination. It is judged to be required for a proposed site of power plant to be located in the upper-stream region, for the park unit, which is space of the living culture, to be repaired and expanded the existing facilities, and for traffic network to be expanded through predicting demand along with new-town development. It is judged to be probably needed to be reflected even the flexible aspect for changing design through surveying the feasibility and economic efficiency on the future spatial design.

Catalytic Wet Gasification of Biomass Mixed Fuels (바이오메스 혼합연료의 습윤 촉매 가스화 연구)

  • Kang, Sung-Kyu;Lee, Seung-Jae;Ryu, In-Soo;Hur, Sung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.17 no.2
    • /
    • pp.59-72
    • /
    • 2009
  • In order to utilize sewage sludge as a heat source of energy, it goes without saying that the fuel should be clean and pose no threat to the environment. As a consequent, it should not contain even minute quantities of heavy metals / impurities. The SOCA (Sludge-Oil-Coal- Agglomerates) fuel can meet all these requirements. SOCA being a solid fuel can be gasified for the production of clean energy. Wet catalytic gasification is the most appropriate process for SOCA containing nearly 60% water. It is important to note that the SOCA thus obtained inherits ca. 40~50% of sulfur from the coal used. It can poison the catalyst during catalytic gasification process. Consequently, it becomes important to choose a proper catalyst for the gasification. Calcium was found to be ideal choice as a catalyst for the gasification of SOCA. The optimal gasification was performed at $850^{\circ}C$ with water vapor. The role of fuel-N is of utmost importance in the gasification of SOCA. The gasification should be controlled to reduce the production of HCN to a minimum and enhance its conversion to $N_2$ and/or $NH_3$.

Monitoring of Micro Noxious Chemicals Caused by Fiber and Chemistry Industrial Wastewater on the Nakdong River Water System (낙동강 수계의 섬유 및 화학 산업폐수로부터 발생하는 미량유해화학물질의 모니터링)

  • Kim Man-Il;Kang Mee-A
    • The Journal of Engineering Geology
    • /
    • v.16 no.2 s.48
    • /
    • pp.145-152
    • /
    • 2006
  • Industry development caused numerical and quantitative increase of noxious chemical substances that contain risk assessment in water resources. For use of efficient water resources a pre-treatment of contaminant source which is flowed in water resources is recognized in essential process. Therefore, the discharged water quality from discharged company began to control contaminant by total amount of pollutant in domestic. However, to estimate closely chemical substances it is not proved up to now, monitoring is very important. This study achieved a monitoring of micro noxious chemical substance by fiber and chemistry industrial wastewater inflow to examine risk assessment of the water system of Nakdong river. Chloroform was measured highest among volatile organic compounds (VOCs) that the results of water quality of influent and effluent are detected from 7 companies of study area. The other side, because measured value of detected chloroform is indefinite detection level in the same company, it is difficulty in management of water quality. However it may not be much effects of the water system of Nakdong river because these company's effluent is high treatment efficiency of chloroform (more than 88%) in sewage treatment plant. On the other hand, in the investigated results for the European Union specified priority substance that is detected to relationship influent and effluent from fiber/chemistry associated industries, these substances were not detected and domestic data was hardly referred. Therefore, data construction of continuous monitoring about this water quality may have to be achieved certainly to utilize as country policy.

Water Management Plan for the Nakdong River Using TOC and COD (총유기탄소와 화학적산소요구량을 이용한 낙동강 물관리 방안)

  • Bo Eun Kim;Meea Kang;Gyo-Cheol Jeong
    • The Journal of Engineering Geology
    • /
    • v.33 no.1
    • /
    • pp.51-59
    • /
    • 2023
  • The Nakdong river is both a natural resource crucial to underwater ecosystems and a water source for its basin's residents. Industrial wastewater and domestic sewage must meet the relevant standards for discharged water before they can flow into the river. The correlation between old and new measures of organic matter was examined using water quality data from 50 monitoring locations in the main stream of the Nakdong river. The coefficient of determination (R2) for total organic carbon (TOC), the new measure of organic matter, and chemical oxygen demand (COD), the old measure of organic matter, in the main stream of the Nakdong river was 0.6134, indicating high correlation. Water quality at each location assessed using TOC and COD showed disparities that cannot be ignored: quality appeared higher when evaluating the main stream of the Nakdong river using TOC instead of COD. Therefore, there remains a need to review water quality ratings based on TOC; continuous monitoring of COD is also required. In addition, the cause of the difference should be clearly identified to help assess artificial sources of pollution and natural factors affecting organic matter. Water management of the Nakdong river will then be possible using the water quality rating.

Study on the Estimation Equation of Effluent Concentration from Constructed Wetland for Domestic Wastewater Treatment (생활오수 처리를 위한 인공습지의 처리수 수질 추정식에 관한 연구)

  • Yoon, C.G.;Kwun, S.K.;Jeon, J.H.
    • Journal of Korean Society on Water Environment
    • /
    • v.16 no.4
    • /
    • pp.491-499
    • /
    • 2000
  • Effluent concentration estimation equations for treatment wetland were reviewed with 3 -year experimental data. Four equations from USEPA, WPCF, Kadlec and Knight, and this study were applied to the over 100 data points of 1996 to 1999 study at the pilot plant in Konkuk University. The system was a subsurface flow type and consisted of 60cm depth of sand and reeds, and it worked continuously including winter with domestic sewage from school building. Generally, all the equations demonstrated reasonable agreement with experimental data and they could be used for design process if selected carefully. Among them, the equation from this study showed the best fit for the data. The reason might be not only the equation was derived from the experimental data, but also it included plant coverage parameter in the equation while others did not Plant coverage was proved to be an important parameter in the prediction of the treatment wetland system, and its inclusion in the estimation equation could improve the accuracy. Although existing equations could be used in the wetland design, pilot plant experiment for the anticipated condition and subsequent equation development can provide more reliable equation. It takes time to obtain meaningful data from wetland system. Therefore, timely onset of well organized study is recommended before large scale application of treatment wetland system to either point or nonpoint source pollution abatement.

  • PDF