• Title/Summary/Keyword: Sewage water source

Search Result 176, Processing Time 0.023 seconds

Evaluation on Pollution Load Characteristics and Influence of Tributaries in the Hwangguji Stream (황구지천 유역의 오염부하 특성 및 지류 영향 평가)

  • Lim, Su-Jin;Lim, Byung-Ran;Lee, Han-Saem;Kang, Joo-Hyoung;Ahn, Tae-Ung;Shin, Hyun-Sang
    • Journal of Korean Society on Water Environment
    • /
    • v.37 no.4
    • /
    • pp.249-262
    • /
    • 2021
  • This study investigated the pollution characteristics of the main pollution zone in the Hwangguji watershed and the influence of the tributary on the main stream. The characteristics of the main pollution zone, including, the water quality index (WQI), stream rating, load duration curve (LDC), delivery load density (DLD), and contribution of the tributary to the mainstream, were evaluated by time-series visual heatmap. The WQI of the mainstream of Hwangguji was lowered to the poor (IV) level from the inflow point of Suwon stream (SW) and the LDC excess rate in the T-P was higher than that of BOD5, especially for the wet season, suggesting that management of non-point source with T-P is preferred. The contribution (%) of the tributaries in the upstream section of Hwangguji watershed were BOD5 14.54%, TOC 15.67%, T-N 5.43%, and T-P 6.97%. In particular, the Suwon sewage treatment plant located in the mainstream showed a high contribution of BOD5 (64.40%) and T-P (53.54%), respectively, due to the high discharge rate (6.019 m3/sec). Meanwhile, Sammi and Gal stream have a large impact on the mainstream with high DLD and poor WQI. Thus, both streams were considered as pollution hot spots. These results provide useful basic data for preparing more effective water quality improvement and management plans in the watershed.

Developing Evaluation Index and Item for Water Environment Improvement of Gyeongin ARA Waterway (경인 아라뱃길의 물환경 개선을 위한 오염원인 평가항목 및 지표 개발)

  • Lee, Kyung-Su;Kim, Tae-Hyeong
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.8
    • /
    • pp.469-482
    • /
    • 2018
  • This research has developed the criteria and index for systematically and objectively assessing the quality of river water by fixing the various factors that affect Gyeongin ARA waterway's water quality through analysis with the Delphi Technique and analytic hierarchy program (AHP) Method. Based on the results, the highest criteria are, in order of importance, physical and environmental factors 28%, administrative factors 26%, natural fixed factors 26% and finally, cultural and social factors 20%. The three dimensions of the criteria show that for the internal physical and environmental factors, the most important are the loss of self-purification capacity, and the external factors are Gulpocheon and the sludge deposit due to Gyulhweon-weir the bridge. The facility factor in management was affected by the coagulation and waste water disposal facilities. The problem for the policy and institutional factors was seen in the regulatory area. The aquatic ecology/ point pollution source for the natural fixed factors show that it is due to the polluted water of Gulpo-cheon and the living environment/ non-point pollution source is shown through the inflow water from other rivers. Cultural and social factors show that the economical causes were due to the cargo and passenger flight operations and the external factors of having a lack of sewage treatment equipment have an importance effect. In order to estimate the order of priority through logical evidence and objectivity, future research must be continued on the evaluation indexes to measure the specific methodology and technique needed to improve the Gyeongin ARA Waterway.

Study on Analysis of the Proper Ratio and the Effects of Low Impact Development Application to Sewage Treatment District (하수처리구역 내 LID 적용에 대한 적정비율 및 효과분석 연구)

  • Shin, Hyun Suk;Kim, Mi Eun;Kim, Jae Moon;Jang, Jong Kyung
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.12
    • /
    • pp.1193-1207
    • /
    • 2013
  • Increase of impervious area caused by overdevelopment has led to increase of runoff and then the problem of flooding and NPS were brought up. In addition, as decrease of base flow made groundwater level to decline, a stream that dries up is issued. low impact development (LID) method which is possible to mimic hydrological water cycle, minimize the effect of development, and improve water cycle structure is proposed as an alternative. As introduction of LID in domestic increases, the study on small watershed is in process mainly. Also, analysis of property of hydrological runoff and load on midsize watershed, like sewage treatment district, is required, the study on it is still insufficient. So, area applying LID practices from watershed of Dongrae stream is pinpointed and made the ratio and then expand it to watershed of Oncheon stream. Among low impact development practices, Green Roof, Porous Pavement, and Bio- retention are selected for the application considering domestic situations and simulated with SWMM-LID model of each watershed and improvement of water cycle and reduction of non-point pollution loads was analysed. Improvement of water cycle and reduction of non-point pollution loads were analyzed including the property of rainfall and soil over long term simulation. The model was executed according to scenario based on combination of LID as changing conductivity in accordance with soil type of the watershed. Also, this study evaluated area of LID application that meets the efficiency of conventional management as a criteria for area of LID practices applying to sewer treatment district by comparing the efficiency of LID application with that of conventional method.

Estimation of Nitrate-nitrogen Contamination Sources in Cheju Island Groundwater using $\delta$$^{15}$ N Values ($\delta$$^{15}$ N값을 이용한 제주도 지하수중의 질산성질소 오염원추정에 관한 연구)

  • 오윤근;현익현
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.4 no.1
    • /
    • pp.1-4
    • /
    • 1997
  • This study was carried out to find out the source of nitrate-nitrogen (NO$_3$-N) contamination in the groundwater in Cheju Island. Among the sites which have exceeded or may exceed the criterion level (10 mg/L) of NO$_3$-N in drinking water, seven sampling sites including two reference sites were chosen. The former regions are mainly agricultural ones (A-1 to A-6) and residential (R). The latter regions are forest (F-1 and F-2). The predicted major source and its contribution to NO$_3$-N concentration at each site, using $\delta$$\^$15/N and NO$_3$-N concentration, were as follow; Those at A-1, R and F-1 was 61.1%, 50.0% and 20.0% to manure or domestic sewage, 27.8%, 45.7% and 40.0% to chemical fertilizers and 11.1%, 4.3% and 40.0% to natural soil, respectively. Those at A-2 to A-6 were 37.8%, 25.0%, 40.9%, 26.2% and 35.7% to manure or domestic sewage, 59.6%, 71.7%, 53.0%, 71.5% and 60.2% to chemical fertilizers and 2.6%, 3.3%, 6.1%, 2.3% and 4.1% to natural soil, respectively.

  • PDF

Best Buffer Width of Riparian Buffer Zone using a Pilot with Different Plant Species for Reduction of Non-point Pollutant Loading (비점오염저감을 위한 수변완충지대의 적정 설계)

  • Kim, Sung-Won;Choi, I-Song;Oh, Jong-Min
    • Journal of Environmental Impact Assessment
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2008
  • Non-point pollution is caused by many diffusive sources, unlike a point pollution derived from industrial wastewater treatment plants or sewage treatment plants. Runoff of non-point pollutants is originated from rainfall or thawing in short period of time moving over and through the a ground surface. They cause ill effect on the quality of neighboring aquatic environment. To prevent effectively the wash off from non-point pollutant, it should be immediately reduced at the source or be treated after gathering of runoff water. This study has been carried out for the best width of riparian buffer zone. So we implemented the experiment in terms of its depth, width and kind of vegetations and calculated the reduction of pollutants loading. The experimental zone encompasses the watershed of Namhan River (Kyunggido Yangpyunggun Byungsanri). The region was divided into 5 land cover sectors : grass, reed, pussy willow, mixed(grass+pussy willow) and natural zone to compare effectiveness of vegetation. Water samples from four points have been collected in different depths. And the pollutant removal efficiency by sectors with different plant species was yielded through influent with one of each sample. And we obtained the correlation between the width of riparian buffer zone and the removal efficiency of pollutants. Using correlation result, the width of riparian buffer zones which needs to improve the water quality of river could be derived.

The Effect of Sulfur/Limestone Ratio on the Efficiency of Sulfur-Utilizing Denitrification (황/석회석 충전비가 황-이용 탈질효율에 미치는 영향)

  • Shin, Hyung-Soon;Lee, Il-Su;Hwang, Yong-Yoo;Bae, Jae-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.3
    • /
    • pp.271-280
    • /
    • 2000
  • This study was conducted to determine the applicable loading rate and to evaluate the possibility of using limestones as an alkalinity source for the removal of ${NO_3}^{-}-N$ remaining after denitrification/nitrification process with the down-flow sulfur packed bed reactor(SPBR). The pretreated sewage was fed to SPBR. Three SPBRs were filled with elemental sulfur particles and limestones and the volumetric ratios of sulfur to limestone were 0%, 12.5% and 25% for R-0%, R-12.5% and R-25%, respectively. The applicable loading rate was evaluated increasing flow rate with influent ${NO_3}^{-}-N$ concentration of 20 mg/L. For R-0% with external alkalinity supply, denitrification efficiency was greater than 96% up to loading rate of $354.8g\;{NO_3}^{-}-N/m^3{\cdot}day$, and corresponding EBCT was 1.4hr. For R-12.5% and R-25%, where alkalinity was supplied by the limestone filled in the reactor, denitrification efficiency was greater than 94% up to loading rate of $283.8g\;{NO_3}^{-}-N/m^3{\cdot}day$, and corresponding EBCT was 1.7hr. The slightly better performance of R-12.5 compared to R-25 suggests that the volumetric sulfur to limestone ratio of 12.5% was enough for the supply of alkalinity required for sulfur-utilizing denitrification. DO was appeared not showing inhibitory effect on sulfur-utilizing denitrification. The clogging of SPBR caused by the produced gas can effectively be eliminated by regular introduction of treated water in up-flow mode.

  • PDF

The Recovery of Carbon Source from Municipal Primary Sludge using Pilot Scale Elutriated Acidogenic Fermentation (Pilot scale 세정산발효를 이용한 하수 일차슬러지의 산발효)

  • Kwon, Kooho;Kim, Siwon;Jung, Yongjun;Min, Kyungsok
    • Journal of Wetlands Research
    • /
    • v.15 no.2
    • /
    • pp.165-170
    • /
    • 2013
  • Pilot scale study was carried out to produce Volatile Fatty Acids with primary sludge from municipal wastewater treatment plant. An acid fermenter was operated at pH 9, $35^{\circ}C$, SRT of 3.5-4.25d, using a final effluent as elutriating water(Mode-I) and pH 9, SRT 5d, temperature of $35^{\circ}C$(Mode-II), $55^{\circ}C$(Mode-III), using a primarily treated water as elutriating water. Although solubilization rate was enhanced with the increase of temperature, the VFAs production rate was decreased. The VS reduction was shown approximately 56%, and the sludge volume reduction was 93%. The optimal conditions for solubilization was obtained at pH 9, $35^{\circ}C$ and SRT of 5d.

Material Budgets in the Nakdong River Estuary with Simple Box Model (낙동강 하구해역에서의 단순 박스모델에 의한 물질수지)

  • Hong Suk-Jin;Lee Dae-In;Kim Dong-Myung;Park Chung-Kil
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.3 no.3
    • /
    • pp.50-57
    • /
    • 2000
  • Budgets of fresh water, salt, DIN and DIP in the Nakdong river estuary were estimated in order to clarify the characteristics of material cycling and fluxes of nutrients with a simple box model. Freshwater inflow into this system was approximately 1.1E+10m³/y, water exchange was 3.3E+10m³/y and water residence time was 2.03 day assumed with salinity between estuary and adjacent ocean. Nutrients loadings were 3.2E+09mol DIN/y3.7×10³, 2.7E+07mo1 DIP/y, respectively. net ecosystem metabolism was 2.4E+07mo1 C/y. Although the Nakdong river discharge was the main source of nutrients but Jang-rim sewage treatment plant effluent take parts of 16% of nitrogen and 10.2% of phosphorus loadings.

  • PDF

수질 장기관측자료를 활용한 우리나라의 지하수 수질변동 특성

  • 김규범;이강근
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.94-96
    • /
    • 2003
  • Since 1995, MOCT(Ministry of Construction and Transportation) and KOWACO(Korea Water Resources Corporation) have established the National Groundwater Monitoring Network in South Korea and also MOE(Ministry of Environment) has operated Groundwater Quality Monitoring network. Until 2001, 202 monitoring stations by MOCT and 780 monitoring wells by MOE have been constructed, measured groundwater level and analyzed water samples. Groundwater quality analysis has been conducted two times a year during last 6 years for all monitoring wells. The quality data has about 15 components including pH, COD, Count of Coliform group, and etc.. Trend analysis has been peformed for 6 components(Coliform, pH, COD, NO$_3$-N, Cl and EC) of water quality which are analyzed more than 7 times for total monitoring wells. Two test methods have been used ; Sen's test and Mann-Kendall test. These trend tests have been done at the 0.05 significance level. By the result of Sen's test, Count of Coliform group has either upward or downward trends at 4.3 percent of the monitoring points. pH does at 5.6 percent, COD does at 8.6 percent, Nitrate-Nitrogen does at 13.2 percent, Chloride does at 13.4 percent, and. EC does at 11.6 percent of the monitoring points. The exact causes of the groundwater quality trends are difficult to specify. Notable downward trends in nitrate at many monitoring points may be the result of reduction on some contamination sources. Potential causes include diminished agricultural areas, improvements in sewage treatment and a decrease in atmospheric deposition. Increase in chloride at many monitoring points may be the result of increased non-point source pollution such as road salting and runoff from sprawling paved developments and suburbs.

  • PDF

Application of the Flowerbed Type Infiltration System for Low Impact Development - Focus on the Application to Eco-Village - (저부하형 개발을 위한 화단형 빗물침투시설 적용방안 - 생태전원마을에서의 적용을 중심으로 -)

  • Han, Young-Hae;Lee, Tae-Goo;Schuetze, T.
    • KIEAE Journal
    • /
    • v.12 no.3
    • /
    • pp.33-40
    • /
    • 2012
  • Since 2000 country region developmental policy has been to integrate not only the improvement of physical living environment but also various subjects on ecology, environment, scenery, local culture, and green tourism. This study has recently established a decentralized Rainwater Management plan in order to provide an hydrology cycle system to the eco-village being planned by Seocheon-gun as a part of the garden village development business promoted by the ministry of agriculture and forestry. Hydraulic conductivity of the subject area is measured at $10^{-7}{\sim}10^{-10}m/sec$, and a flowerbed-type rainwater Infiltration system capable of controlling a non-point pollution source that stems from the development-caused impermeable surface has been applied. In the case of rainwater flowing out from the main entrance way and parking lot within the complex being treated in the flowerbed-type rainwater infiltration system, natural purification effects via soil and plants as well as natural water cycling effects through evaportranspiration and infiltration are expected. The significance of this study, compared to conventional decentralized rainwater management being applied limited to the urban areas, is that it offers appropriate rainwater management planning based on the analysis of the current situation of the subject area. Decentralized Rainwater Management is a valuable measure both economically and ecologically that reduces the burdens on local underground water cultivation as well as rain water pipe lines or purification systems, and sewage pipes.