• Title/Summary/Keyword: Separation of particles

Search Result 449, Processing Time 0.027 seconds

Physical Treatment for Reclaiming Spent Carbon-Zinc and Alkaline $MnO_2$batteries (廢망간電池 /알칼리망간電池 資源化를 위한 物理的 處理)

  • 손정수;안종관;박경호;전호석
    • Resources Recycling
    • /
    • v.10 no.3
    • /
    • pp.43-50
    • /
    • 2001
  • Characteristics of crushing and magnetic separation on the spent batteries, were investigated for reclaiming spent carbon-zinc and alkaline manganese dioxide batteries. Crushing of carbon zinc battery was easier than that of alkaline $MnO_2$battery using impact type crusher with rotary blades. Most of magnetic products were distributed in the range of 8 mesh size. With crushing 1 ton of spent carbon-zinc and alkaline $MnO_2$batteries respectively, magnetic separation of 8 mesh oversize particles, we can get 214 kg and 235 kg of magnetic products which is composed of 94% and 88% of Fe.

  • PDF

The treatment of coolant wastewater of rolling plate process by High Gradient Magnetic Separation

  • Kim, Tae-Hyung;Ha, Dong-Woo;Kwon, Jun-Mo;Sohn, Myung-Hwan;Baik, Seung-Kyu;Oh, Sang-Soo;Ko, Rock-Kil;Kim, Ho-Sup;Kim, Young-Hun;Park, Seong-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.4
    • /
    • pp.8-11
    • /
    • 2009
  • This study introduced wastewater treatment method by High Gradient Magnetic Separation (HGMS). HGMS treatment was high efficient method for various industrial wastewaters. The system is currently research state, but we have surveyed commercialize the technology for industry. In rolling plate process, coolant wastewater was recycled by sedimentation and sand filter system. It needs several large reservoirs and long time to remove suspended solid (SS) like metal fines and iron oxide in hot rolling plate making process. If removing rate of suspended solid in rolling coolant wastewater is improved by using HGMS system, the productivity of working process can be increased and the area of reservoir can be reduced. We manufactured high temperature superconducting HGMS system that had a purpose to treatment of coolant wastewater in rolling plate process. We fabricated the prototypes of magnetic matrix filter consisting of stainless steel 430 mesh, which is a core component in the magnetic separation system, In our basic preliminary experiment using HGMS system, it has been clear that the fine paramagnetic particles in the coolant wastewater obtained from rolling plate process of POSCO can be separated with high efficiency.

Magnetic Particle Separation by an Optimized Coil: A Graphical User Interface

  • Rouhi, Kasra;Hajiaghajani, Amirhossein;Abdolali, Ali
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.214-219
    • /
    • 2017
  • Magnetic separators that clean the fluid stream from impurities, protect the installations in numerous industries. This paper introduces a graphical user interface (GUI) which proposes an optimized coil separating magnetic particles with a radius from 1 up to 500 µm. High gradient magnetic fields are employed in an arbitrary user defined fluidic channel which is made of a nonmetallic material. The effects of coil parameters are studied and adjusted to design an optimum coil with a minimum Ohmic loss. In addition, to design the coil scheme based on the particle movements, a mathematical particle-tracing model within the fluid channels has been utilized. In comparison to conventional magnetic separators, this model is reconfigurable by the user, produces a weaker magnetic field, allows for continuous purifying and is easy to install, with high separation efficiency. The presented GUI is simple to use, where the coil's manufacturing limitations can be specified.

Development of Droplet Sizing Technique in Spay Flow (분무유동에서 입경 계측기법의 개발)

  • Yang, Chang-Jo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.1
    • /
    • pp.67-73
    • /
    • 2007
  • Recently, fire extinguishing systems based on water mists have been attracting public attentions in marine engineering. Performance of fire extinguishing systems is very strongly influenced by the size and distribution of spayed water mists. Therefore, the present study has developed droplet analyzing method based on image processing. The morphological technique based on partial curvature information of pre-processed images with relaxation method was adopted for recognition and separation of overlapped particles. Tested results showed that the present method may be reliable for the analysis of the size and distribution of droplets in spray flow of fire extinguishing systems based water mists.

Development and Evaluation of Dry Lubricant Recycle Technologies for Wire Drawing Process (와어어 인발용 건식 윤활제의 재생기술 개발 및 평가)

  • Kim, Sun-Ho;Jang, Gyu-Chul;Lee, Chi-Wook
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.2
    • /
    • pp.35-40
    • /
    • 2014
  • Wire drawing is aplastic deformation process that produces a wire with a desired diameter by pulling the end of the wire through a die. During the cold wire drawing process, the temperature between the wire and the die bearing is increased. This temperature increase causesenergy consumption increase, bad wire quality, and decreased die life. To reduce friction and avoid high temperature between the wire and the die in the cold wire drawing process, a dry lubricant with soap particles is used. It is not possible to reused the lubricant onceiron oxide is attached to the soap particlesat high pressure die. In this study, recycling technologies for wasted soap particles with processes of crushing, separation, and screening are developed. From the evaluation, the recycling efficiency was found to be 86.97%.

The Measurement of Bubble Driven Flow Using PIV and Digital Mask Technique (PIV 기법과 Digital Mask 기법을 적용한 버블유동 측정)

  • Kim, Sang-Moon;Kim, Hyun-Dong;Kim, Kyung-Chun
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2700-2703
    • /
    • 2008
  • An experiment on bubble-driven flow was performed in order to understand fundamental knowledge of flow structure around a rising bubble in a stagnant fluid. The measurement technique consists of a combination of the three most often used PIV techniques in multiphase flows: PIV with fluorescent tracer particles, the digital phase separation with a masking technique and a shadowgraphy. The key point of the measurement is that the background intensity of a PIV recording can be shifted to a higher level than a bubble region using a shadowgraphy in order to distinguish from fluorescent particles and a bubble as well. Flow fields were measured without an inaccurate analysis around a fluid-bubble interface by using only one camera simply.

  • PDF

Operation Conditions for Continuous DAF Process with Domestic DAF Pump (국산 DAF 펌프가 적용된 연속 DAF 공정의 운전 조건)

  • An, Dae Myung;Lee, Chang Han;Ahn, Kab Hwan;Cho, Seok Ho;Kim, Seong-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.2
    • /
    • pp.242-246
    • /
    • 2004
  • Dissolved air flotation (DAF) is an effective solid/liquid separation process for low density particles, such as algal flocs, humus materials and clay particles produced from low turbidity water. The fraction of humic substances for natural organic matters (NOMs) are considered problematic in water because it can readily react with chlorine to form harmful by-products (trihalomethanes) and can be exposed to undesirable color, tastes and odors in drinking water. A broad class of NOMs includes fulvic acid, humic acid and humin. This paper will discuss the results from a study that performed with a DAF pump process using synthetic wastewater contained humic substance. Batch jar tests were performed to evaluate coagulant dose and recycle ratio on flotation efficiency.

A mesoscale model for concrete to simulate mechanical failure

  • Unger, Jorg F.;Eckardt, Stefan;Konke, Carsten
    • Computers and Concrete
    • /
    • v.8 no.4
    • /
    • pp.401-423
    • /
    • 2011
  • In this paper, a mesoscale model of concrete is presented, which considers particles, matrix material and the interfacial transition zone (ITZ) as separate constituents. Particles are represented as ellipsoides, generated according to a prescribed grading curve and placed randomly into the specimen. In this context, an efficient separation procedure is used. The nonlinear behavior is simulated with a cohesive interface model for the ITZ and a combined damage/plasticity model for the matrix material. The mesoscale model is used to simulate a compression and a tensile test. Furthermore, the influence of the particle distribution on the loaddisplacement curve is investigated.

Characteristics of Particle Laden Flows in Circular Microchannels (원형 마이크로채널 내의 입자가 부유된 유동의 특성)

  • Kim Y.W.;Jin S.W.;Yoo J.Y.
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.85-88
    • /
    • 2005
  • Experimental study has been conducted to evaluate characteristics of particle laden flows at the ratio of channel diameter to particle diameter (B = 14.9, 21.6 and 55). Particle velocities and radial concentrations are obtained using a microscope Nd:YAG laser and cooled CCD camera. Results show that there are relative velocities between the fluid and the particles at B = 14.9. It is also observed that the particles are accumulated at r=$0.5\∼0.82R$, with R being tile tube radius, and particle migration occurs at small Reynolds number, by comparing with the results obtained in macro scale. This gives optimal factors for designing microfluidic channels for cell or Particle separation, particle focusing, and so on.

  • PDF

Separation of Colloidal Particles by Holow Fiber Flow Field Flow Fractionation Using Osmotic Sink (삼투압을 이용한 중공사막 흐름장 흐름 분획법에 의한 콜로이드 입자의 분리)

  • 신세종;이원주;전용한;이경현;민병렬
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.110-112
    • /
    • 1998
  • 1. 서론 : 분석화학의 중요한 과제중 하나 고효율(high efficiency)과 고해상도(high resolution)를 가지고서 혼합물에서 분자나 입자의 분리능을 개선하는 것과 낮은 수준의 농도에서 이런 분획들(fractions)을 정량화 하는 것이다. 현재의 추세는 분리하고자 하는 분자의 상한선을 증가시키는 것이 순수과학과 산업에서 중요하게 되었다. 이런 분리 기술의 응용은 거대분자(macromolecules)와 입자들(particles)인 cell fragments, plasmides, chromosomes, liposomes, synthetic polymers 등에 적용되고 있는데, 고전적인 분석방법으로는 한외여과, 원심분리, 크기배제 크로마토그래피 등이 있지만 시간이 걸리고 해상도와 효율에 제한이 있다.

  • PDF