• Title/Summary/Keyword: Separation flow

Search Result 1,792, Processing Time 0.024 seconds

Simultaneous Analysis of Bangpungtongseong-san and Its Antioxidant Effect (방풍통성산의 동시분석 및 항산화 효능 연구)

  • Seo, Chang-Seob;Kim, Ohn Soon;Shin, Hyeun-Kyoo
    • Herbal Formula Science
    • /
    • v.21 no.2
    • /
    • pp.133-143
    • /
    • 2013
  • Objectives : We carry out the simultaneous quantification for quality control of four components in Bangpungtongseong-san (BPTSS) sample. In addition, we assessed the antioxidant effects of BPTSS sample. Methods : The used column for separation and analysis of four compounds was Luna C18 column and column oven temperature was maintained at $40^{\circ}C$. The mobile phase for simultaneous determination consisted of two solvent systems, 1.0% acetic acid in water and 1.0% acetic acid in acetonitrile. High performance liquid chromatography-photodiode array (HPLC-PDA) method for analysis was performed at a flow rate of 1.0 mL/min with PDA detection at 254 and 280 nm. The injection volume was 10 ${\mu}L$. The antioxidant activities of BPTSS were evaluated by measuring free radical scavenging activities on 2,2'-Azinobis-3-ethyl-benzothiazoline-6-sulfonic acid (ABTS) and 1-1-diphenyl-2-picrylhydrazyl (DPPH). The inhibitory effects on low-density lipoprotein (LDL) oxidation were evaluated by the formation of thiobarbituric acid relative substances (TBARS) and relative electrophoretic mobility (REM). Results : Calibration curves were acquired with $r^2{\geq}0.9999$. The values of limit of detection (LOD) and quantification (LOQ) were 0.06-0.29 ${\mu}g/mL$ and 0.20-0.98 ${\mu}g/mL$, respectively. The amounts of geniposide, liquiritin, baicalin, and glycyrrhizin in BPTSS were 5.06, 7.33, 27.56, and 7.81 mg/g, respectively. The BPTSS showed the radical scavenging activity in a dose-dependent manner. The concentration required for 50% reduction (RC50) against ABTS and DPPH radicals were 72.51 ${\mu}g/mL$ and 128.49 ${\mu}g/mL$. Furthermore, GMGHT reduced the oxidation properties of LDL induced by CuSO4. Conclusions : The established HPLC-PDA method will be helpful to improve quality control of BPTSS. In addition, BPTSS has potentials as therapeutic agent on anti-atherosclerosis.

Resonant Characteristics in Rectangular Harbor with Narrow Entrance (2.Effects of Entrance Energy Loss) (개구부가 좁은 직사각형 항만의 공진 특성 (2.항입구 에너지 손실의 영향))

  • 정원무;박우선;서경덕;채장원
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.11 no.4
    • /
    • pp.216-230
    • /
    • 1999
  • A Galerkin finite element model for the analysis of harbor oscillation has been developed based on the extended mild-slope equation. Infinite elements are used to accomodate the radiation condition at infinity and joint elements to treat the matching conditions at the harbor entrance which include the energy loss due to flow separation. The numerical tests for rectangular harbors with fully or partially open entrances show that the energy loss at the harbor entrance considerably reduces the the amplification ratios at the innermost parts of the harbors and that the amplification ratios decrease considerably with increasing incident wave heights and jet lengths at the harbor entrance. Application of the model to the Gamcheon harbor show that when the incident wave amplitude is small the amplification ratios rather increase when the entrance energy loss is included than when ignored because of the shift of the resonance periods. Even though the entrance energy loss was insignificant for the measured long-period incident waves, it would be of great importance if the incident waves were large as in the attack of tsunamis. The resonance period of the Helmholtz mode at the Gamcheon Harbor was calculated to be 31 minutes, which agrees well with the measured one between 27 and 33.3 minutes. The measured resonance periods between 9.4 and 12.1 minutes and 5.2 and 6.2 minutes were also calculated by the numerical model as 10.4 minutes and 6.6 or 5.6 minutes, indicating good performance of the model. On the other hand, it was shown that a variety of oscillation modes exists in the Gamcheon Harbor and lateral resonances of considerable amplification ratios also exist at the periods of 3.6 and 1.6 minutes as in the Young-II Bay.

  • PDF

Elution Behavior of Pd(II) - Isonitrosoethylacetoacetate Imine Chelates by Reversed Phase High Performance liquid Chromatography (역상 액체 크로마토그래피에 의한 Pd(II) - Isonitrosoethylacetoacetate Imine 유도체 킬레이트들의 용리 거동)

  • Kim, In-Whan;Shin, Han-Chul;Lee, Man-Ho;Yoon, Tai-Kun;Kang, Chang-Hee;Lee, Won
    • Analytical Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.389-399
    • /
    • 1992
  • Liquid Chromatographic behavior of Pd(II) in Isonitrosoethylacetoacetate lmine, $Pd(IEAA-NR)_2$ (R=H, $CH_3$, $C_2H_5$, $n-C_3H_7$, $C_6H_5-CH_2$, $n-C_4H_9$) chelates were investigated by reversed-phase HPLC on Micropak MCH-5 column using methanol/water as mobile phase. The optimum conditions for the separation of $Pd(IEAA-NR)_2$ chelates were examined with respect to the effect of the flow rate, sample solvent, mobile phase strength and column temperature. It wass found that metal chelates were properly eluted in an acceptable range of capacity factor value($0{\leq}log\;k^{\prime}{\leq}1$). The dependence of the logarithm of capacity factor(k') on the volume fraction of water in the binary mobile phase was examined. Also, the dependence of k' on the liquid-liquid extration distribution ratio($D_c$) in methanol-water/n-alkane extration system was investigated. Both kinds of dependence are linear, which susggests that the retention of the electroneutral metal chelate is largely due to the solvophobic effect. Standard adsorption enthalpy changes (${\Delta}H^{\circ}$) and standard adsorption entropy changes (${\Delta}S^{\circ}$) of Pd(II) Isonitrosoethylacetoacetate imine chelates on Micropak MCH-5 column were calculated by measuring capacity factor with changing temperature of the column.

  • PDF

Validation of LC-MS/MS method for determination of ginsenoside Rg1 in human plasma (인체 혈장 중 Ginsenoside Rg1의 정량을 위한 LC-MS/MS 분석법 검증)

  • Kim, Yunjeong;Han, Song-Hee;Jeon, Ji-Young;Hwang, Min-Ho;Im, Yong-Jin;Lee, Sun Young;Chae, Soo-Wan;Kim, Min-Gul
    • Analytical Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.221-227
    • /
    • 2013
  • A sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed for the investigation of the ginsenoside Rg1 in human plasma. After addition of internal standard (digoxin), plasma was diluted with acetone and methanol (80:20), the supernatant was concentrated and analyzed by LC-MS/MS. The optimal chromatographic separation was achieved on an Agilent Eclipse XDB-C18 column ($4.6{\times}150mm$, $5{\mu}m$) with a mobile phase of 0.1% formic acid in water and 0.1% formic acid in methanol at a flow rate of 0.9 mL/min gradient mode. The standard calibration curve for ginsenoside Rg1 was linear ($r^2=0.9995$) over the concentration range 1~500 ng/mL in human plasma. The intra- and inter-day precision over the concentration range of ginsenoside Rg1 was lower than 7.53% (correlation of variance, CV), and accuracy exceeded 98.28%. This LC-MS/MS assay of ginsenoside Rg1 in human plasma is applicable for quantifying in the pharmacokinetic study.

Process gas purification using cyclone recirculation and cooling process (싸이클론 재순환, 냉각공정을 이용한 공정가스 정제 연구)

  • Kim, Ju-Hoe;Jo, Woo-Jin;Choi, Young-Tae;Jo, Young-Min;Kim, Sang-Bum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.25-33
    • /
    • 2018
  • Renewable energy has been of interests in the area of modern alternative fuels. Biogas is produced in waste landfill sites through anaerobic digestion processes, including hydrolysis, acidogenesis, organic acid fermentation (acetogenesis), and methane fermentation (methanogenesis). High contents of fine dust and moisture limited its utilization for direct combustion, town gas and vehicle fuel. Thus, this study proposed a new design for a cooling device using a centrifugal cyclone for simultaneous removal of fine dust and moisture as a pretreatment in the purification processes. A heat exchanger and an ID fan, which are installed inside and outside of the cyclone, in order to cool the humid gas below the freezing point and form a foggy mist. Such an atmosphere enhanced to capture fine dust as recirculating the cold mist flow. The water removal rate was 80.8% at a relative humidity of 95%, and the particle removal efficiency was 98.3% for $2.5{\mu}m$. Simultaneous removal efficiency was 70.8% and 99.6% for particle and moisture respectively.

A Study on the Properties of High-Fluidity Concrete with Low Binders Using Viscosity Agent (증점제를 사용한 저분체 고유동 콘크리트의 특성에 관한 연구)

  • Park, Gi-Joon;Park, Jung-Jun;Kim, Sung-Wook;Lee, Dong-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.689-696
    • /
    • 2017
  • The practical applications of ordinary high-fluidity concrete have been limited due to several drawbacks, such as high hydration heat, high amount of shrinkage, and non-economic strength development. On the other hand, due to its advantages, such as improvement of construction quality, reduction of construction cost and period, the development of high-fluidity concrete is a pressing need. This study examined the properties of high-fluidity concrete, which can be manufactured on the low binders using a viscosity agent to prevent the segregation of materials. The optimal viscosity agent was selected by an evaluation of the mechanical properties of high-fluidity concrete among six viscosity agents. The acrylic type and urethane type viscosity agents showed the best performance within the range where no material separation occurred. The mechanical properties were evaluated to examine the optimal amount of AC and UT viscosity agent added by mixing two viscosity agents according to the adding ratio and blending them together with high performance water reducing agent. When the ratio of the AC : UT viscosity agents was 5:5, it was most suited for high-fluidity concrete with low binders by increasing the workability and effect of the reducing viscosity.

Analysis of Cyclic Adenosine Monophosphate (cAMP) Separation via RP-HPLC (reversed-phase high-performance liquid chromatography) by the Moment Method and the van Deemter Equation (역상 크로마토그래피에서 모멘트 방법과 van Deemter 식을 이용한 고리형 아데노신 일인산의 분리특성 연구)

  • Lee, Il Song;Ko, Kwan Young;Kim, In Ho
    • Korean Chemical Engineering Research
    • /
    • v.53 no.6
    • /
    • pp.723-729
    • /
    • 2015
  • The moment analysis of cyclic adenosine monophosphate (cAMP) was performed using chromatograms that were obtained with the pulse input method from an octadecyl silica (ODS) high-performance liquid chromatography (HPLC) column. The general rate (GR) model was employed to calculate the first absolute moment and the second central moment. Three important coefficients for moment analysis, which are molecular diffusivity ($D_m$), external mass transfer coefficient ($k_f$), and intra-particle diffusivity ($D_e$), were estimated by the Wilke-Chang equation, Wilson-Geankoplis equation, and comparing van Deemter equation to theoretical plate number equation, respectively. Experiments were conducted by various conditions of flow rates, methanol volume ratio of the mobile phase, and solute concentration. After the moment analysis, results were organized by van Deemter plots. Also van Deemter coefficients were compared each other to effect $H_{ax}$, $H_f$, and $H_d$ on height equivalent to a theoretical plate (HETP, $H_{total}$). The value of intraparticle diffusion ($H_d$) was the primary factor which makes for HETP whereas external mass transfer ($H_f$) was disregardable factor.

A study on the residues of fluoroquinolones in hen's eggs consumed in Incheon Metropolitan city (인천광역시에서 유통되는 계란의 플루오로퀴놀론계 항균물질 잔류 실태 조사)

  • Park, Eun-Jeong;Lim, Ji-Huen;Lee, Sung-Mo;Im, Jeong-Soo;Oh, Dae-Kyu
    • Korean Journal of Veterinary Service
    • /
    • v.31 no.3
    • /
    • pp.385-395
    • /
    • 2008
  • This study was carried out to investigate the residue level of fluoroquinolones in hen's general eggs and specific eggs by microbiological assay method and high performance liquid chromatography (HPLC) method. HPLC separation was carried out by reversed phase chromatography on a Symmetry $C_{18}$ (250${\times}$4.6 mm, $5{\mu}m$ particle size) with a phase composed of distilled water (containing 0.4% triethylamine and phosphoric acid) : Methanol (780 : 220, v/v), pumped isocratically at a flow rate of 1.0ml/min. A fluorescence detector was utilized with an excitation wavelength of 278nm and an emission wavelength of 456nm. The calibration curves were linear $({\gamma}^2{\geq}0.999)$ over a concentration range of $0.025{\sim}0.4{\mu}g/ml$. Average recoveries of the five fluoroquinolones in whole eggs at fortified levels of $0.05{\sim}0.2{\mu}g/g$ were ranged mean $78.1{\sim}91.7%$ and low coefficient of variation was less than 10% for all analysed samples. The limits of detection and limits of quantification for whole eggs were $1.2{\sim}6.0ng/g$ and $2.3{\sim}9.1ng/g$, respectively. Only one hen's general eggfrom chicken farm in Incheon was detected with the residual fluoroquinolones (Microbiological assay method; 1 of 47 general eggs) ; the range of residual concentration enrofloxacin was 0.12ppm. Those in food stores were detected with the residual fluoroquinolones (Microbiological assay method; 4 of 88 general eggs) ; the ranges of residual concentration enrofloxacin were $0.15{\sim}2.2 ppm$, ciprofloxacin $0.01{\sim}0.06ppm$, and hen's specific eggs (40) in food stores were not detected. For the microbiological assay method of fluoroquinolones in hen's eggs, as the results of comparative analysis, the disc diffusion method with E coli may be a little highly detected for the residual fluoroquinolones.

A Study on Construction of Express Lane Applied by Bus Only Lane as Seperation Facility: Focused on Pangyo-Hannam Section of Gyeongbu Expressway (버스전용차로를 분리시설로 활용한 Express Lane 구축에 관한 연구: 경부고속도로 판교-한남 구간을 중심으로)

  • Kim, Min Kyoung;Kim, Ju Hyun;Shin, Eon Kyo
    • Journal of Korean Society of Transportation
    • /
    • v.31 no.4
    • /
    • pp.32-46
    • /
    • 2013
  • Because of short length between interchanges, traffic congestion has been caused by a lot of short trip traffic in the urban section of interregional expressway. Also, in case of expressway with Bus Only Lane, bus causes dangerous situation by conflicting between vehicles and buses in order to access from Bus Only Lane to IC. Therefore, this study aims to propose Express Lane applied by Bus Only Lane as a new lane operation in order to efficiently operate and to analyze the effectiveness on constructing Express Lane to the Pangyo-Hannam section in Gyeongbu Expressway. The study analyzes effectiveness by scenario using the micro traffic simulation tool, VISSIM 5.4. For this, the indicators which evaluate construction effect of Express Lane, are used by average delay time, average speed and total travel time. The results of the study showed the best effectiveness when Express Lane installed one, and it represented an ideal traffic condition when long distance trip traffic of the whole traffic is 25% in the study section. Therefore, the construction of Express Lane using Bus Only Lane achieves positive effectiveness on safety and expense aspect as well as uncongested flow.

Numerical analysis of solar heat gain on slim-type double-skin window systems - Heat transfer phenomena with opening of windows and vent slot in summer condition - (전산유체 해석을 통한 슬림형 이중외피 창호의 태양열 취득량 분석 - 높은 태양고도 및 하절기 냉방조건에서의 자연환기구 적용 및 창문 조절 방식별 비교 -)

  • Park, Ji-Ho;Oh, Eun-Joo;Cho, Dong-Woo;Cho, Kyung-Joo;Yu, Jung-Yeon
    • KIEAE Journal
    • /
    • v.17 no.1
    • /
    • pp.69-75
    • /
    • 2017
  • Purpose: Heat transfer analysis of recently developed 'slim type double-skin system window' were presented. This window system is designed for curtain wall type façade that main energy loss factor of recent elegant buildings. And the double skin system is the dual window system integrated with inner shading component, enclosed gap space made by two windows when both windows were closed and shading component effectively reflect and terminate solar radiation from outdoor. Usually double-skin system requires much more space than normal window systems but this development has limited by 270mm, facilitated for curtain wall façade buildings. In this study, we estimated thermophysical phenomena of our double-skin curtain wall system window with solar load conditions at the summer season. Method: A fully 3-Dimentional analysis adopted for flow and convective and radiative heat transfer. The commercial CFD package were used to model the surface to surface radiation for opaque solid region of windows' frame, transparent glass, fluid region at inside of double-skin and indoor/outdoor environments. Result: Steep angle of solar incident occur at solar summer conditions. And this steep solar ray cause direct heat absorption from outside of frame surface rather than transmitted through the glass. Moreover, reflection effect of shading unit inside at the double-skin window system was nearly disappeared because of solar incident angle. With this circumstances, double-skin window system effectively cuts the heat transfer from outdoor to indoor due to separation of air space between outdoor and indoor with inner space of double-skin window system.