• Title/Summary/Keyword: Separated construction

Search Result 246, Processing Time 0.026 seconds

The Slope Stabilization of Solid Waste Landfill Liner System (폐기물매립장의 사면차수체계 안정화 연구)

  • Shin, Eunchul;Kim, Jongin;Park, Jeongjun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.3
    • /
    • pp.21-28
    • /
    • 2009
  • As the natural aggregates such as sand and clay are getting exhausted, the quantity of utilizing geosynthetics is being increased in the solid waste landfill. Especially, the waste landfills have been constructed at the gorge in the mountainous area and reclaimed land from the sea in the Korean Peninsula. Those areas are not favorable for construction of waste landfill in geotechnical engineering aspect. In this study, the frictional characteristics of geosynthetics that used in the waste landfill were estimated. Then, the studies of the behavior of geosynthetics and stability of LDCRS (Leachate Detection, Collection, and Removal System) of side slope were conducted in the waste landfill by means of the pilot test, and numerical analysis. Geocomposite which is combined type or separated type is influenced on the strain itself, and also implicated in the stress and strain of geomembrane at the lower layer. The strain on the combined type of geocomposite is about 50% smaller than that of the separated type at the side slope. The lateral displacement and settlement of top at the slope with the separated type are three times greater than that of the combined type. In the numerical analysis, discontinuous plans in between ground and geosynthetic, geosynthetic and geosynthetic, goesynthetic and waste have been modeled with the interface element. The results gave a good agreement with the field large-scale model test. The relative displacements of geosynthetics were also investigated and hence the interface modeling of liner system is appropriate for analysis of geosynthetics liner system in the waste landfill.

  • PDF

Case Study of Improvement against Leakage of a Sea Dike under Construction (해안제방 시공 중 해수유입에 대한 차수보강 사례분석)

  • Han, Sang-Hyun;Yea, Geu-Guwen;Kim, Hong-Yeon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.14 no.2
    • /
    • pp.95-103
    • /
    • 2015
  • In this study, the causes and countermeasures for the leakage of a sea dyke under construction are analyzed. In general, the seabed ground is clearly divided from the embankment but a lot of parts show abnormal zones with low resistivity from the results of electric resistivity survey. Hence the causes of the leakage are considered as following: three-dimensional shear strain behavior, irregular compulsory replacement of the soft seabed ground with low strength and quality deterioration of the waterproof sheets during the closing process. The improvement method is determined by considering the constructability in the seawater and its velocity condition, durability, economic feasibility, similar application cases and so on. Consequently, a combination of low slump mortar and slurry grouting and injection method is selected as an optimum combination. Mixing ratio and improvement pattern are determined after drilling investigation and pilot test. The improvement boundary is separated into general and intense leakage area. The construction is performed with each pattern and the improvement effects are confirmed. The confirmed effects with various tests after completion show tolerable ranges for all of the established standards. Finally, various issues such as prediction of length of the waterproof sheet, installation of it against seawater velocity, etc. should be considered when sea dykes are designed or executed around the western sea which has high tide difference.

Compressive Strength Evaluation of Concrete with Mixed Plastic Waste Aggregates Filled with Blast Furnace Slag Fine Powder (무기충진재를 혼입한 복합 폐플라스틱 골재를 활용한 콘크리트 압축강도 특성)

  • Lee, Jun;Kim, Kyung-Min;Cho, Young-Keun;Kim, Ho-Kyu;Kim, Young-Wook
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.3
    • /
    • pp.253-259
    • /
    • 2021
  • Plastic wastes generated from household waste are separated by mixed discharge with foreign substances, and recycling is relatively low. In this study, the effect of the ratio and content of mixed plastic waste coarse aggregate(MPWCA)s and mixed plastic waste fine aggregate(MPWFA)s filled with blast furnace slag fine powder on the slump and compressive strength of concrete was evaluated experimentally. The MPWCAs were found to have a similar fineness modulus, but have a single particle size distribution with a smaller particle size compared to coarse aggregates. However, the MPWFAs were found to have a single particle size distribution with a larger fineness modulus and particle size compared to fine aggregates. Meanwhile, the effect of improving the density and filling pores by the blast furnace slag fine power was found to be greater in the MPWFA compared to the MPWCA. As the amount of the mixed plastic waste aggregate(MPWA)s increased, the slump and compressive strength of concrete decreased. In particular, the lower the slump and compressive strength of concrete was found to decrease the greater the amount of MPWFA than MPWCA when the amount of MPWA was the same. This is because of the entrapped air and voids formed under the angular- and ROD-shaped aggregates among the MPWFAs. On the other hand, the addition of the admixture and the increase in the unit amount of cement were found to be effective in improving the compressive strength of the concrete with MPWAs.

Analysis of Debonding between Mixed Finite Elements for Saturated Porous Media (혼합유한요소를 통한 다공질매체의 요소분리해석)

  • Tak, Moonho;Lee, Janggeun;Ban, Hoki;Kang, Jaemo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.18 no.2
    • /
    • pp.53-58
    • /
    • 2017
  • In this paper, we propose a new method to debond between mixed finite elements for porous media in ABAQUS (2014). ABAQUS just provides debonding algorithm for the u-p model using cohesive elements in standard version. However, this approach has a drawback that it is hard to simulate complex debonding problems like element separation, rigid body motion, and contact between separated elements in standard version. ABAQUS-explicit can resolve these complex problems, but cohesive elements for the u-p model cannot be applied. We introduce a new algorithm for debonding for porous media instead of using cohesive elements. In this method, subroutines VUMAT to apply constitutive models and VDISP to separate elements in ABAQUS are used to simulate debonding problems. In addition, a simple 2-D example is demonstrated in the ABAQUS-explicit solver.

A Study on the LCC Analysis of an Office Building HVAC System (오피스빌딩 냉난방시스템의 수명주기비용 분석에 관한 연구 : 흡수식 냉온수 유닛의 설치 유형을 중심으로 한 사례연구)

  • Park, Moon-Sun;Shin, Hyeong-Sik;Kim, Yong-Su
    • Korean Journal of Construction Engineering and Management
    • /
    • v.7 no.3 s.31
    • /
    • pp.112-121
    • /
    • 2006
  • The purpose of this study is to execute economical analysis for two types of office building HVAC system using LCC technique : single vs, separated HVAC(equal partition installation, unequal partition installation) system. The research method of this study includes the case analysis and questionnaire surveys. The results of this study are as follows: (1) LCCs of 3 types of HVAC system are estimated and the most economical one is investigated as single HVAC system, (2) In this case study, the single HVAC system was investigated as 34% lower in LCC during 15 years per $100m^2$ compared to equal partition installation, as 41% compared to unequal partition installation.

Aeroelastic Behaviors of Self-anchored Suspension Bridge with Lateral Sag of Main Cable(II) - Focused on the Behavior of Tower - (횡방향 새그를 가진 자정식 현수교의 공탄성 거동(II) - 주탑의 거동을 중심으로 -)

  • Kwon, Soon Duck;Chang, Sung Pil
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.2 s.31
    • /
    • pp.269-275
    • /
    • 1997
  • Wind tunnel test results and their interpretations, which were performed to study the aerodynamic stability of tower of self-anchored suspension bridge, are presented in this paper. Tower and full models were tested under smooth and turbulent flow conditions. In the case of the tower with inclined two columns, the vibration due to wakes were occurred at wide velocity zone because the wakes with various frequencies were generated by inclined upstream column. It has to be emphasized that the vibration characteristics of the tower in the self-anchored suspension bridge may be very sensitive to the longitudinal boundary conditions of the girder at the supports. Because of the two natural frequency of the tower, out-of-plane bending and torsional, were not well separated, coupled motions were observed in a wide range of wind velocity. The effectiveness of corner cut, countermeasure to reduce the tower vibrations, was also studied. It has been found that 1:10, comer cut size to column width, may be the most effective ratio for reducing the vibrations.

  • PDF

A Study on the Decision-making Factors of Living-in Idea into Unsold Apartment of Metropolitan Area (수도권 미분양아파트 구매의사결정 영향요인 분석)

  • Tak, Jung-Ho;Rho, Jeong-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.4
    • /
    • pp.247-255
    • /
    • 2017
  • The study figured out the preference factors which should be considered for investor on decision making of unsold apartment and analyzed by comparing the difference according to the type. Then, it investigated the preference factors through the previous studies to analyze the influence factor of decision making and demonstrated the effects through the PLS (Partial Least Squares) regression. In addition, it separated the target type to tenants and construction firms and carried out the survey for comparing the preference factors of investor type. The result of analysis found out that tenants emphasis on preference factors such as the internal factor (1.141), conditional relaxation (1.114), environment factor (1.107), social factor (1.048), external factor (1.030), educational environment factor (1.010) and etc. Then, construction firms emphasis on preference factors such as the social factor (1.401), environment factor (1.251), conditional relaxation (1.133) and etc. In addition, common preferences factors are the conditional relaxation, social factor, environment factor.

Evaluation of Energy Production for a Small Wind Turbine Installed in an Island Area (도서지역 소형풍력발전기 에너지 발생량 평가)

  • Jang, Choon-Man;Lee, Jong-Sung;Jeon, Wan-Ho;Lim, Tae-Gyun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.24 no.6
    • /
    • pp.558-565
    • /
    • 2013
  • This paper presents how to determine AEP(Annual Energy Production) by a small wind turbine in DuckjeokDo island. Evaluation of AEP is introduced to make a self-contained island including renewable energy sources of wind, solar, and tidal energy. To determine the AEP in DuckjeokDo island, a local wind data is analyzed using the annual wind data from Korea Institute of Energy Research firstly. After the wind data is separated in 12-direction, a mean wind speed at each direction is determined. And then, a small wind turbine power curve is selected by introducing the capacity of a small wind turbine and the energy production of the wind turbine according to each wind direction. Finally, total annual wind energy production for each small wind turbine can be evaluated using the local wind density and local energy production considering a mechanical energy loss. Throughout the analytic study, it is found that the AEP of DuckjeokDo island is about 2.02MWh/y and 3.47MWh/y per a 1kW small wind turbine installed at the altitude of 10 m and 21m, respectively.

INVESTIGATION OF THE OPERATIONAL PRINCIPLE AND PARAMETRIC STUDY ON A DRY PASTE SEPARATOR EQUIPED WITH A ROTOR -II. CFD ANALYSIS (로터 장착 건식 미분 분리기의 작동원리 규명 및 파라미터 연구 - II. CFD 해석)

  • Park, S.U.;Kang, Y.S.;Kang, S.;Suh, Y.K.
    • Journal of computational fluids engineering
    • /
    • v.20 no.4
    • /
    • pp.81-92
    • /
    • 2015
  • Construction waste mainly consists of concrete aggregates of various size. Improper handling of concrete waste would be a major environmental problem whereas its recycling would be both economically useful and environmentally friendly. Bigger concrete aggregates are crushed and converted to medium and fine particles to make them recyclable. An apparatus to separate the concrete aggregates by their size is thus needed for their effective recycling. In this work, segregation of concrete particles in air flows from a newly designed rotary separator having three stages of blades is simulated using a commercial software, ANSYS-CFX. Both 2-D and 3-D models with 360, 240 and 180 blades in each stage are considered. Fundamental mechanism of separation of particles(pase) and the effect of design parameters such as particle size, rotor speed, air flow rate etc. on the performance of the separator are investigated. Critical size of particles that can be separated by the developed separator is also presented in this work. Simulation results are overall in good agreement with data predicted from the theoretical model previously reported in the companion paper.

A Study on Using the Interior Finishing Material using Regulation at Multiple-using Businesses (다중이용업소 실내마감재료 사용기준에 관한 연구)

  • Kim, Yong-Sung;Cho, Sung-O
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.5
    • /
    • pp.216-224
    • /
    • 2013
  • There are the relevant provisions that apply to building regulations about the Building codes, Fire Protection laws, and more Multi-using interior finish materials businesses etc. The differences between these regulations are as follows: The Building codes is defined the main use of the building according to facilities to used to set the scale by the use of the floor space, On the other hand, Fire Protection laws are the basic purpose and the act of using the architectural space(or sales) by separating object by fire. And Multiple-using Businesses Facilities consist of two regulations engaged in the kind of law and the size of the floor area. One building can not be based on operating facilities and together in Multiple use businesses Law. As such, the Buildings are applied to the Building codes, Fire Protection laws, such as Multi-using Businesses Facilities interior construction industry due to the structural differences in the position of the designer feeling a lot of difficulties and confusion. The Multi-use businesses Facilities engage in the kind of law, the size of the floor area and seating capacity. These can not be based on operating facilities, and consists of two regulations together in one building. This study is purposed to help improving the finish of the interior architecture that is related to the Building code regulations, Fire Protection laws, Multi-using Facilities interior finishing material relevant with the provisions from the law through analyze the case of developed countries, and the current Multiple use Businesses Facilities research range from the law of multiple-using facilities, interior finishing, interior architecture for supervision reasonably and compensation for the interior design. So, Result is as follows: First, interior decorations can be separated the fixed material and the moveable things. second, It should be included multi-using Business though small size business space at the basement floor. third, It should be established statute law that design and construction responsibility. forth, re-testing fire resist performance after some period. and finally, it need to mitigate regulation where be installed sprinkler.