Abstract
Wind tunnel test results and their interpretations, which were performed to study the aerodynamic stability of tower of self-anchored suspension bridge, are presented in this paper. Tower and full models were tested under smooth and turbulent flow conditions. In the case of the tower with inclined two columns, the vibration due to wakes were occurred at wide velocity zone because the wakes with various frequencies were generated by inclined upstream column. It has to be emphasized that the vibration characteristics of the tower in the self-anchored suspension bridge may be very sensitive to the longitudinal boundary conditions of the girder at the supports. Because of the two natural frequency of the tower, out-of-plane bending and torsional, were not well separated, coupled motions were observed in a wide range of wind velocity. The effectiveness of corner cut, countermeasure to reduce the tower vibrations, was also studied. It has been found that 1:10, comer cut size to column width, may be the most effective ratio for reducing the vibrations.
본 연구에서는 자정식 현수교 주탑의 내풍 안정성을 보기 위하여 주탑 모형 실험과 전교 모형 실험을 수행하고 그 결과를 분석하였다. 경사진 병렬 탑주를 가진 주탑의 경우에는 다양한 주파수대의 웨이크가 존재하므로 넓은 풍속대에서 진동이 발생한다는 사실을 확인하였다. 자정식 현수교의 경우에는 주형의 교축방향 지지조건에 따라 주탑 진동 모드가 매우 민감하게 변화하였다. 본 연구 대상 주탑은 면외 휨 모드와 비틈 모드의 고유진동수가 매우 근접해 있어서 넓은 범위의 풍속에서 연성진동이 발생하였다 주탑 진동을 완화하기 위한 공기역학적 수단으로 모서리 자르기를 시도하였는데, 탑주의 폭과 잘린 모서리의 비가 1/10일 때가 가장 효과적이었다.