• Title/Summary/Keyword: Seong Dae-Jung

Search Result 574, Processing Time 0.025 seconds

Characteristics for Nanofluid Droplet Evaporation on Heated Surface at Boiling Temperature of Base Liquid (비등점의 가열 표면에서 나노유체 액적의 증발 특성)

  • Kim, Dae Yun;Jung, Jung-Yeul;Lee, Seong Hyuk
    • Journal of ILASS-Korea
    • /
    • v.20 no.4
    • /
    • pp.236-240
    • /
    • 2015
  • This study aims to experimentally investigate the evaporation characteristics of nanofluid droplet on heated surface at boiling temperature of DI-water. In particular, textured surface was used to examine the effect of wettability on evaporation. At the initial stage of evaporation process, dynamic contact angle (DCA) of nanofluid droplet with 0.01 vol.% concentration on textured surface rapidly increased over its equilibrium contact angle by generated large bubble inside the droplet due to lower wettability. However, contact angle of nanofluid droplet with higher concentration on textured surface decreased with surface tension. In addition, total evaporation time of droplet on textured surface was considerably delayed due to reduction of contact area between droplet and solid surface. Thus, evaporation characteristics were highly affected by the nanofluid concentration and surface wettability.

Direct Drive PM Motor Design for Next Generation Locomotive (차세대 전동차용 직구동형 영구자석 전동기 설계기술)

  • Kim, Min-Seok;Park, Ji-Seong;Kim, Dae-Kwang;Kim, Jung-Chul;Jung, Sang-Yong
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1860-1865
    • /
    • 2008
  • The propulsion for locomotive application has changed from the DC motor system to the induction motor system. Although the induction motor system has almost reached the stage of maturity, this system also needs to be changed to the PM motor system for the direct drive without using reduction gear. Thus, the IPMSM(Interior buried Permanent Magnet Synchronous Motor) has been adopted to meet the locomotive driving specification. In this paper, the design of IPMSM satisfying driving specifications for the direct drive has been performed using the advanced F.E.M.

  • PDF

Cordyceps Militaris Complex extract Treatment for Rheumatoid Arthritis : A Retrospective Observational Study (동충하초 복합추출물로 치료받은 류마티스 관절염 환자군에 대한 후향적 관찰 연구)

  • Ko, Seong Hwan;Kim, Sang Woo;Kim, Nam Hoon;Kim, Si Yeon;Lee, Eun-jung
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.35 no.5
    • /
    • pp.193-198
    • /
    • 2021
  • The purpose of this study is to observe the effect of Cordyceps Militaris(CM) complex extract treatment on patients diagnosed with rheumatoid arthritis(RA). We reviewed medical records of 9 rheumatoid arthritis patients who visited the pain & rehabilitation center, Daejeon Korean Medicine Hospital of Daejeon University and were treated with CM complex extract from October 14, 2019 to October 14, 2020. We analyzed the records of DAS 28(Disease Activity Score 28), CDAI(Clinical Disease Activity Index), SDAI(Simplified Disease Activity Index), VAS(Visual analogue Scale), and KHAQ-D(Korean Health Assesment Questionnaire-Disability Index) before and after treatment to evaluate the effects of CM complex extract on RA. As a result, the scores of DAS 28(p<0.05), CDAI(p<0.01), SDAI(p<0.01) and VAS(p<0.01) were statistically significantly decreased, after 8 weeks of taking CM complex extract in RA patients. In conclusion, CM complex extract treatment may have potential effects of reducing disease activity and pain and improving quality of life in patients diagnosed with RA.

A study on the second edition of Koryo Dae-Jang-Mock-Lock (고려재조대장목록고)

  • Jeong Pil-mo
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.17
    • /
    • pp.11-47
    • /
    • 1989
  • This study intends to examine the background and the procedure of the carving of the tablets of the second edition of Dae-Jang-Mock­Lock(재조대장목록). the time and the route of the moving of the tablets. into Haein-sa, and the contents and the system of it. This study is mainly based on the second edition of Dae-Jang-Mock-Lock. But the other closely related materials such as restored first. edition of the Dae- Jang-Mock-Lock, Koryo Sin-Jo-Dae-Jang-Byeol-Lock (고려신조대장교정별록). Kae-Won-Seok-Kyo-Lock (개원석교록). Sok-Kae­Won-Seok-Kyo-Lock (속개원석교록). Jeong-Won-Sin-Jeong-Seok-Kyo­Lock(정원신정석교록), Sok-Jeong-Won-Seok-Kyo-Lock(속정원석교록), Dea-Jung-Sang-Bu-Beob-Bo-Lock(대중상부법보록), and Kyeong-Woo-Sin-Su-Beob-Bo-Lock(경우신수법보록), are also analysed and closely examined. The results of this study can be summarized as follows: 1. The second edition of Tripitaka Koreana(고려대장경) was carved for the purpose of defending the country from Mongolia with the power of Buddhism, after the tablets of the first edition in Buin-sa(부이사) was destroyed by fire. 2. In 1236. Dae-Jang-Do-Gam(대장도감) was established, and the preparation for the recarving of the tablets such as comparison between the content, of the first edition of Tripitalk Koreana, Gal-Bo-Chik-Pan-Dae­Jang-Kyeong and Kitan Dae- Jang-Kyeong, transcription of the original copy and the preparation of the wood, etc. was started. 3. In 1237 after the announcement of Dae-Jang-Gyeong-Gak-Pan-Gun­Sin-Gi-Go-Mun(대장경핵판군신석고문), the carving was started on a full scale. And seven years later (1243), Bun-Sa-Dae-Jang-Do-Gam(분사대장도감) was established in the area of the South to expand and hasten the work. And a large number of the tablets were carved in there. 4. It took 16 years to carve the main text and the supplements of the second edition of Tripitaka Koreana, the main text being carved from 1237 to 1248 and the supplement from 1244 to 1251. 5. It can be supposed that the tablets of the second edition of Tripitaka Koreana, stored in Seon-Won-Sa(선원사), Kang-Wha(강화), for about 140 years, was moved to Ji-Cheon-Sa(지천사), Yong-San(용산), and to Hae-In-Sa(해인사) again, through the west and the south sea and Jang-Gyeong-Po(장경포), Go-Ryeong(고령), in the autumn of the same year. 6. The second edition of Tripitaka Koreana was carved mainly based on the first edition, comparing with Gae-Bo-Chik-Pan-Dae-Jang-Kyeong(개보판대장경) and Kitan Dae-Jang-Kyeong(계단대장경). And the second edition of Dae-Jang-Mock-Lock also compiled mainly based on the first edition with the reference to Kae-Won-Seok-Kyo-Lock and Sok-Jeong-Won-Seok-Kyo-Lock. 7. Comparing with the first edition of Dae-Jang-Mock-Lock, in the second edition 7 items of 9 volumes of Kitan text such as Weol-Deung­Sam-Mae-Gyeong-Ron(월증삼매경론) are added and 3 items of 60 volumes such as Dae-Jong-Ji-Hyeon-Mun-Ron(대종지현문논) are substituted into others from Cheon chest(천함) to Kaeng chest(경함), and 92 items of 601 volumes such as Beob-Won-Ju-Rim-Jeon(법원주임전) are added after Kaeng chest. And 4 items of 50 volumes such as Yuk-Ja-Sin-Ju-Wang-Kyeong(육자신주왕경) are ommitted in the second edition. 8. Comparing with Kae-Won-Seok-Kyo-Lock, Cheon chest to Young chest (영함) of the second edition is compiled according to Ib-Jang-Lock(입장록) of Kae-Won-Seok-Kyo-Lock. But 15 items of 43 vol­umes such as Bul-Seol-Ban-Ju-Sam-Mae-Kyeong(불설반주삼매경) are ;added and 7 items of 35 volumes such as Dae-Bang-Deung-Dae-Jib-Il­Jang-Kyeong(대방등대집일장경) are ommitted. 9. Comparing with Sok-Jeong-Won-Seok-Kyo-Lock, 3 items of the 47 volumes (or 49 volumes) are ommitted and 4 items of 96 volumes are ;added in Caek chest(책함) to Mil chest(밀함) of the second edition. But the items are arranged in the same order. 10. Comparing with Dae- Jung-Sang-Bo-Beob-Bo-Lock, the arrangement of the second edition is entirely different from it. But 170 items of 329 volumes are also included in Doo chest(두함) to Kyeong chest(경함) of the second edition, and 53 items of 125 volumes in Jun chest(존함) to Jeong chest(정함). And 10 items of 108 volumes in the last part of Dae-Jung-Sang-Bo-Beob-Bo-Lock are ommitted and 3 items of 131 volumes such as Beob-Won-Ju-Rim-Jeon(법원주임전) are added in the second edition. 11. Comparing with Kyeong-Woo-Sin-Su-Beob-Bo-Lock, all of the items (21 items of 161 volumes) are included in the second edition without ;any classificatory system. And 22 items of 172 volumes in the Seong­Hyeon-Jib-Jeon(성현집전) part such as Myo-Gak-Bi-Cheon(묘각비전) are ommitted. 12. The last part of the second edition, Joo chest(주함) to Dong chest (동함), includes 14 items of 237 volumes. But these items cannot be found in any other former Buddhist catalog. So it might be supposed as the Kitan texts. 13. Besides including almost all items in Kae-Won-Seok-Kyo-Lock and all items in Sok-Jeong-Won-Seok-Kyo-Lock, Dae-Jung-Sang-Bo­Beob-Bo-Lock, and Kyeong-Woo-Sin-Su-Beob-Bo-Lock, the second edition of Dae-Jang-Mock-Lock includes more items, at least 20 items of about 300 volumes of Kitan Tripitaka and 15 items of 43 volumes of traditional Korean Tripitake that cannot be found any others. Therefore, Tripitaka Koreana can be said as a comprehensive Tripitaka covering all items of Tripitakas translated in Chinese character.

  • PDF

A Survey of Adverse Events and Safety following Treatment of the Facial Cosmetic Acupuncture (Miso-Acupuncture) (안면미용침의 부작용 및 안전성에 대한 조사;시술자 23인을 중심으로)

  • Kwon, Seung-Koo;Lee, Yun-Kyu;Park, Seo-Young;Ko, Kyoung-Mo;Lee, Yoon-Kyoung;Kim, Jae-Su;Lee, Bong-Hyo;Lim, Seong-Chul;Jung, Tae-Young;Lee, Kyung-Min
    • Journal of Acupuncture Research
    • /
    • v.25 no.1
    • /
    • pp.199-209
    • /
    • 2008
  • Objectives : To explore the adverse events and safety following facial cosmetic acupuncture treatment (Miso-Acupuncture). Subjects and methods : This study was a retrospective survey of practitioner's reports. The practitioners worked as facial cosmetic acupuncturists, gave informed consent, and completed a case report form between July and November of 2007. On this form, practitioners were asked to report the degree of adverse events relating to the Miso-Acupuncture, the total safety of the treatment, and reasons patients gave for quitting treatment. The practitioners in this study were all Oriental Medicine Doctors(OMD) who had trained at the Miso-Acupuncture Academy for 40 hours we received 23 final report cases. Results : In this study, adverse events following Miso-Acupuncture treatment were mild bruising(15 ; 65.2%), bleeding(12 ; 52.2%), pain(8 ; 34.8%), fatigue(7 ; 30.4%), headache(5 ; 21.7%), and others(10 ; 43.5%). The average degree of adverse events was between mild and moderate, which needs no extra treatment. The total safety of treatment for 16 weeks was between safe and nearly safe, and there was no need to quit treatment in spite of mild adverse events. Eight patients(34.8%) quit treatment, almost all for personal reasons unrelated to the Miso-Acupuncture. Conclusions : These results suggest that the Miso-Acupuncture has no serious adverse events and is a relatively safe treatment.

  • PDF

A New line Matching Technique for Solving Correspondence Problem in Stereo Method (스테레오 방식에서 일치성 문제를 해결하기 위한 새로운 선소 정합법)

  • Kang, Dae-Kap;Kwon, Jung-Jang;Kim, Seong-Dae
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.3
    • /
    • pp.116-123
    • /
    • 1990
  • Most algorithms utilized the horizontal epipolar lines for solving the correspondence problem in 3-D computer vision. However, the requirement is very difficult to be satisfied in real situations. In this paper, we propose a binocular-stereo matching algorithm, based on line matching method, which does not require the horizontal epipolar lines of the extreme pixels of a given line segment and two circles whose radius is equal to the maximum disparity. And we use the features including the direction of line segments, edge strength and cross-correlation for line matching. The experimental results show that the proposed algorithm can be a useful tool for solving the correspondence problem in 3-D computer vision.

  • PDF

ANALYSIS AND INTERPRETATION OF ELECTRIC CHARACTERISTICS OF DRY ETCHING PROCESS FOR THE TFT-LCD FABRICATION

  • Kwon, O-Dae;Kwon, Han-Bum;Yoo, Su-Jin;Kim, Jong-Keun;Jeon, Jae-Hong;Lee, Kang-Woong;Choe, Hee-Hwan;Seo, Jong-Hyun;Seong, Dae-Jin;Kim, Jung-Hyun;Hyeon, Yong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.922-925
    • /
    • 2007
  • In the usual dry etching process for the TFT-LCD fabrication, it is hard to monitor the basic plasma parameters such as density and temperature. However, the basic parameters are easily monitored during the dry etching process. We have simultaneously measured the electric characteristics and basic plasma parameters of the dry etching chamber during the process, analyzed them to interpret plasma parameters. For the Ar plasma discharge case, we could obtain the density and temperature from the electric characteristics using a simple simple sheath model.

  • PDF

Synthesis of Titanium Dioxides from Peroxotitanate Solution Using Hydrothermal Method and Their Photocatalytic Decomposition of Methylene Blue (수열합성법에 의한 과산화티탄 수용액으로부터 이산화티탄의 합성 및 메틸렌블루의 광분해반응)

  • Jung, Won Young;Lee, Seung Ho;Kim, Dae Sung;Lee, Gun Dae;Park, Seong Soo;Hong, Seong-Soo
    • Korean Chemical Engineering Research
    • /
    • v.48 no.4
    • /
    • pp.417-422
    • /
    • 2010
  • Nanosized $TiO_2$ particles were prepared by hydrothermal method from the aqueous peroxotitanate solution using the different carboxylic acids as an additives. The physical properties of prepared nanosized $TiO_2$ particles were investigated and we also examined the activity of $TiO_2$ particles as a photocatalyst on the decomposition of methylene blue. The major phase of all the prepared $TiO_2$ particles was an anatase structure regardless of carboxylic acids and a rutile peak was observed above $700^{\circ}C$. The photocatalytic activity increased with an increase of hydrocarbon number of carboxylic compounds and the highest activity was shown on the catalysts which was prepared using succinic acid as an additive and calcined at $500^{\circ}C$.

Evaluation of SWAT Model for Hydrological Analysis of Hwa-Cheon Watershed (화천 지역의 수문분석을 위한 SWAT 모형의 적용성 평가)

  • Kim, Gi-Cheol;Kim, Jong-Geon;Park, Yun-Sik;Heo, Seong-Gu;Yu, Dong-Seon;Kim, Gi-Seong;Choe, Jung-Dae;Im, Gyeong-Jae
    • KCID journal
    • /
    • v.14 no.2
    • /
    • pp.207-213
    • /
    • 2007
  • For sustainable development at a watershed, environment friendly site-specific management practices need to be developed and implemented. The soil and Water Assessment Tool(SWAT)model has been world-wide used to estimate stream flow, sediment, and nonpoint source pollutant loads, and effects on water quality of different management practices. In this study, the SWAT model was used to estimate the flow resources at Hwacheon areas using Digital Elevation Model(DEM),Land use, precipitation ,wind ,maximum and minimum temperature, solar radiation, humidity of watershed The R2 value and EI value for the comparison of SWAT estimated flow and measured flow were 0.87 and 0.67 respectively for calibration period, and the R2 value and E1 value for validation were 0.75 and 0.67 respectively. The comparison results show what the SWAT model is applicable to simulate hydrology behaviors at this study watershed.

  • PDF