• Title/Summary/Keyword: Sensor waveform

Search Result 139, Processing Time 0.026 seconds

Characteristics of Temperature Variation to the Piezoelectric Bimorph for Vortex Flowmeter (와류 유량센서용 압전 바이몰프의 온도변화에 따른 특성)

  • Lee, Guen-Taek;Kim, Hyung-Sun;Im, Jong-In
    • Korean Journal of Materials Research
    • /
    • v.17 no.5
    • /
    • pp.289-292
    • /
    • 2007
  • Although piezoelectric bimorph that is using as the sensor in medical and industrial measurement has large displacement, it has problems including efficiency in generating force, energy convergence, and response. Its application is being limited based on the change in resonance frequency with temperature. In this study, to overcome the disadvantages, PZT piezoelectric ceramics was prepared and produced a parallel type piezoelectric bimorphs. In addition, by using the finite element method. the configuration of piezoelectric bimorph was designed and the displacement of the bimorph based on applied electric pressure and the wave pattern were measured. By analyzing the resonance characteristics of the bimorph in the temperature range of $-60{\sim}80^{\circ}C$, an attempt was made to study the operational characteristics and temperature reliability of vortex flowmeter sensor. As a result, the resonance frequency of the bimorph was gradually increased with the temperature from $-60{\sim}80^{\circ}C$. The deflection of the bimorph was found to strongly depend on both the applied electric field waveform and the environmental temperature.

Development for body temperature sensor and monitoring telemetry system (체온측정용 온도 센서 및 모니터링 텔레메트리 시스템 구현)

  • Lee, Jyung-Hyun;Seong, Ki-Woong;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.435-442
    • /
    • 2010
  • Typically, the vital signs that are representing the state of human body, are the body temperature, sphygmus, respiration and blood pressure. The body temperature is the result of metabolic regulation and human steady-state body temperature is maintained from 35.9 to $37.4^{\circ}C$ by heat regulatory center. The body temperature is indicative of infection and especially it should be monitored to requiring intensive care patients or after surgical patients. But, measuring of body temperature to a heavy workload on nursing staff has been recognized. And, the health service of nurse is limited by simple tasks such as the measurement and record of vital sign. In this paper, the body temperature monitoring telemetry system was proposed to prove the recoding and transmission of body temperature patch system according the standard(ISO TS11073-92001). We proposed the transmission protocol to suit the MFER(medical waveform format encoding rules). The telemetry patch system was implemented and it was verified by experiments.

Development of the Vehicle Diagnosis Program Using OBD-II (OBD-II 시스템을 활용한 자동차 고장진단 프로그램 개발)

  • Yoo, Changhyun;Ko, Yongseo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.3
    • /
    • pp.271-278
    • /
    • 2015
  • This paper develops an OBD Diagnostic Program (Program) using Visual Studio (C#), which was used to diagnosis malfunction information from OBD-II system vehicles. We accomplished this using the Program, Diagnostic tests, Board (STN1110), FTDI Basic Cable, Mini USB Cable, OBD Data Cable, and both hybrid and regular vehicles. The Program tests real-time data output, DTC output, sensor value output, engine RPM, waveform data, OBD type check, PID inspection, and whole monitoring. We found vehicles used in this research had 19 PIDs, which was within OBD-II regulations. We also gathered data on control and diagnostic code regulated by OBD-II system, such as, sensor output value, engine RPM, DTC output, each PID analytic value, OBD type, fuel mode, and whole monitoring result value. Using the data collected through the Program appropriately can lead to more effective diagnostic practices and contribute to education.

A study on the Development of Sensorless Driver for Electric Compressor Brushless DC Motor (전동식 컴프레서 브러시리스 직류 전동기용 센서리스 드라이브 개발에 관한 연구)

  • Cho, Jung-Hun;Park, Sung-Jun
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.374-375
    • /
    • 2019
  • In this paper, In the whole industry, there is a tendency to replace brushless motors with brushless motors because of the high rate of failure in DC motors with brushes. Accordingly, many methods for driving a brushless motor have been developed and studied. In order to drive the brushless motor, it is essential to know the information about the rotor position of the motor. However, it is not possible to use a position sensor for rotor disconnection due to the structure of an electric compressor brushless DC motor. In this paper, we investigate the rotor position of the motor by using the counter electromotive force included in the voltage of the terminal made by Y connection by using the resistance of each phase without using Hall sensor or encoder generally used to detect the rotor position. A sensorless drive system for a square wave brushless direct current (DC) motor is proposed. To do this, we propose a method to detect the rotor position from the analyzed terminal voltage waveform by performing terminal voltage analysis of each phase for 3-phase, 2-exciton unipolar PWM.

  • PDF

Systolic blood pressure measurement algorithm with mmWave radar sensor

  • Shi, JingYao;Lee, KangYoon
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.4
    • /
    • pp.1209-1223
    • /
    • 2022
  • Blood pressure is one of the key physiological parameters for determining human health, and can prove whether human cardiovascular function is healthy or not. In general, what we call blood pressure refers to arterial blood pressure. Blood pressure fluctuates greatly and, due to the influence of various factors, even varies with each heartbeat. Therefore, achievement of continuous blood pressure measurement is particularly important for more accurate diagnosis. It is difficult to achieve long-term continuous blood pressure monitoring with traditional measurement methods due to the continuous wear of measuring instruments. On the other hand, radar technology is not easily affected by environmental factors and is capable of strong penetration. In this study, by using machine learning, tried to develop a linear blood pressure prediction model using data from a public database. The radar sensor evaluates the measured object, obtains the pulse waveform data, calculates the pulse transmission time, and obtains the blood pressure data through linear model regression analysis. Confirm its availability to facilitate follow-up research, such as integrating other sensors, collecting temperature, heartbeat, respiratory pulse and other data, and seeking medical treatment in time in case of abnormalities.

Load Disturbance Compensation for Stand-alone Inverters Using an Inductor Current Observer

  • Choe, Jung-Muk;Moon, Seungryul;Byen, Byeng-Joo;Lai, Jih-Sheng;Lim, Young-Bae;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.389-397
    • /
    • 2017
  • A control scheme for stand-alone inverters that utilizes an inductor current observer (ICO) is proposed. The proposed method measures disturbance load currents using a current sensor and it estimates the inductor current using the ICO. The filter parameter mismatch effect is analyzed to confirm the ICO's controllability. The ICO and controllers are designed in a continuous-time domain and transferred to a discrete-time domain with a digital delay. Experimental results demonstrate the effectiveness of the ICO using a 5-kVA single-phase stand-alone inverter prototype. The experimental results demonstrate that the observed current matches the actual current and that the proposed method can archive a less than 2.4% total harmonic distortion (THD) sinusoidal output waveform under nonlinear load conditions.

Detection of Axial Defects in Pipes Using Chirplet Transform (첩릿변환을 이용한 배관 축방향 결함검출)

  • Kim, Young-Wann;Park, Kyung-Jo
    • Journal of Power System Engineering
    • /
    • v.20 no.4
    • /
    • pp.26-31
    • /
    • 2016
  • The implementation of chirplet transform to locate axially aligned defects in pipes has been investigated. The results are obtained from experiments performed on a carbon steel pipe using magnetostrictive sensors. Chirplet transform is applied to the reflected signal to separate the individual modes from dispersive and multimodal waveform. The separated modes are used to calculate reflection coefficients which would be used to characterize defects. It is found that the reflection from a defect consists of the wave pulses with gradually decaying amplitudes. Also the results show that the reflection coefficient initially increases with the crack length but finally reaches an oscillating regime.

Dynamic Simulation of Linear Switched Reluctance Motor (직선형 스위치드 릴럭턴스 전동기의 동특성 시뮬레이션)

  • Jang, Seok-Myeong;Park, Ji-Hoon;You, Dae-Joon;Lee, Sung-Ho;Sung, Ho-Kyoung;Cho, Han-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2007.10c
    • /
    • pp.71-73
    • /
    • 2007
  • This paper deals with dynamic characteristics of LSRM. Position choose mover of LSRM and inductance. When approved current in each phase by decided position, we made sure current and voltage according to turn-on, turn-off. In dynamic simulation of LSRM, through an experiment, we decided turn-on position of inductance profile. Also, we presented dynamic characteristic analysis model which is consisted at motor and sensor signal part, etc., and substitute circuit constant that get using magnetic equivalent circuit method, we confirmed current and voltage waveform.

  • PDF

A Study on Measurement of Heartrate and Respiration during Sleep using Doppler Radar: Preliminary Study (도플러 레이더를 이용한 수면 중의 심박 및 호흡 측정: 예비연구)

  • Lim, Yong Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.38 no.5
    • /
    • pp.264-270
    • /
    • 2017
  • A Doppler radar sensor was applied to detect respirations and heartbeats of persons who were lying on a bed. This study is preliminary study aiming at non-contact and non-intrusive respiration and heart rate monitoring during sleep in daily life. For the experiments, 10GHz Doppler radar with patch-type antenna was used and installed on the upper right and the distance between the body and the antenna was 1 m. The results show that each signal of respiration and heartbeat is observed in each frequency band however the frequency band and the waveform vary according to the subjects and the posture. The results show that the heartbeats can be detected with the peak detection in some frequency band. This study shows the feasibility of applying the Doppler radar to detection of heartbeat and respiration during sleep and further studies about heartbeat detection algorithm are required.

Comparative analysis of PRPD method and UHF sensor method for Partial Discharge in air (공기중 부분방전에 대한 PRPD측정법과 UHF센서측정법의 비교분석)

  • Lee, K.W.;Lee, Y.H.;Park, S.H.;Jang, D.U.;Kang, S.H.;Lim, K.J.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.882-885
    • /
    • 2002
  • Assessing the condition of air insulation by measuring electromagnetic wave generated in it by partial discharges gives warning of developing faults and breakdown which may give some bad effects to other thing concerned with it. Electromagnetic wave are taken from UHF antenna with 20k ~ 2GHz frequency range. The signal waveform and FFT(Fast Fourier Transform) results from UHF antenna for PD(partial discharge) generated from two different electrode(needle-plane, needle-needle) configurations are shown and it is processed by using PRPD($\Phi-q-n$ distribution) method. Cumulative pulse sequence during 100 period is compared with PRPD method. This also will show the possibility of making apparent distinction between two PD sources.

  • PDF