• Title/Summary/Keyword: Sensor technology

Search Result 8,664, Processing Time 0.038 seconds

Widerange Microphone System Using 3D Range Sensor (3D 거리 센서를 이용한 강의용 광역 마이크 시스템)

  • Oh, Woojin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.25 no.10
    • /
    • pp.1448-1451
    • /
    • 2021
  • In this paper, 3D range sensor is applied to the sensor-based widerange microphone system for lectures. Since the 2D range sensor measures the shortest distance of the speaker, an error occurs and the performance is degraded. The 3D sensor provides a 160×60 distance image so that the position of the speaker can be obtained with accuracy. We propose a method for obtaining the distance per pixel required to determine the absolute position of the speaker from the distance image. The proposed array microphone system using the 3D sensor shows the improvement of 0.8~1.5dB compared to the previous works using 2D sensor.

A Particulate Matter Sensor with Groove Electrode for Real-Time Diesel Engine On-Board Diagnostics

  • Kim, S.;Kim, Y.;Lee, J.;Lim, S.;Min, K.;Chun, K.
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.191-196
    • /
    • 2013
  • A particulate matter sensor fabricated by MEMS process is proposed. It is developed to accommodate Euro6 on-board diagnostics regulation for diesel automobile. In the regulation, emission of diesel particulate matter is restricted to 9 mg/km. Particulate matter sensor is designed to use induced charges by charged particulate matter. To increase sensitivity of the sensor, groove is formed on sensor surface because wider surface area generates more induced charges. Sensitivity of the sensor is measured 10.6 mV/(mg/km) and the sensor shows good linearity up to 15.7 mg/km. Also its minimum detectable range is about 0.25 mg/km. It is suitable to detect failure of a diesel particulate filter which should filter particulate matter more than 9 mg/km. For removing accumulated particulate matter on the sensor which can disturb normal operation, platinum heater is designed on the backside of the sensor. The developed sensor can sense very low amount of particulate matter from exhaust gas in real-time with good linearity.

Development of Calf Link Force Sensors of Walking Assist Robot for Leg Patients (다리 환자를 위한 보행보조로봇의 종아리 링크 3축 힘센서 개발)

  • Kim, Han-Sol;Kim, Gab-Soon
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.114-121
    • /
    • 2017
  • This paper describes the design and fabrication of a three-axis force sensor with parallel plate beams (PPSs) for measuring the calf force while a patient with a walking assist robot is walking. Current walking assist robots can't measure the weight of the patient's leg and the robot's leg which required for robot control. So, the three-axis force sensor in the calf link is designed and manufactured, it is composed of a Fx force sensor, a Fy force sensor and a Fz force sensor. The three-axis force sensor was designed using by FEM(Finite Element Method), and fabricated using strain-gages. The characteristics experiment of the three-axis force sensor was carried out respectively. The test results indicated that the repeatability error and the non-linearity error of three-axis force sensor was less than 0.04% respectively. Therefore, the fabricated three-axis force sensor in the calf link can be used to measure the patient's calf force in the walking assist robot.

Evaluation of Metal Oxide Semiconductor and Electrochemical Gas Sensor Array Characterization for Measuring Wastewater Odor (폐수의 악취측정을 위한 금속산화물 반도체 및 전기화학식 가스센서 어레이 특성 평가)

  • Yim, Bongbeen;Lee, Seok-Jun;Kim, Sun-Tae
    • Journal of Sensor Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.29-34
    • /
    • 2015
  • This study aimed to evaluate the characterization of a metal oxide semiconductor and electrochemical gas sensor array for measuring wastewater odor. The sensitivity of all gas sensors observed in sampling method by stripping was 6.7 to 20.6 times higher than that by no stripping, except sensor D (electrochemical gas sensor). The average reduction ratio of sensor signal as a function of initial dilution rate of wastewater was in the order of food plant > food waste reutilization facility > plating plant. The sensitivity of gas sensors was dependent on both the type of wastewater and the dilution rate. The sensor signals observed by the gas sensor array were correlated with the dilution factor (OU) calculated by the air dilution sensory test with several wastewater ($r^2=0.920{\sim}0.997$), except the sensor signals of sensor D measured in the plating plant wastewater. It seems likely that the gas sensor array plays a role in the evaluation of odor in wastewater and is useful tool for on-site odor monitoring in the wastewater facilities.

Innovative Differential Hall Effect Gap Sensor through Comparative Study for Precise Magnetic Levitation Transport System

  • Lee, Sang-Han;Park, Sang-Hui;Park, Se-Hong;Sohn, Yeong-Hoon;Cho, Gyu-Hyeong;Rim, Chun-Taek
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.310-319
    • /
    • 2016
  • Three types of gap sensors, a capacitive gap sensor, an eddy current gap sensor, and a Hall effect gap sensor are described and evaluated through experiments for the purpose of precise gap sensing for micrometer scale movement, and a novel type of differential hall effect gap sensor is proposed. Each gap sensor is analyzed in terms of resolution and environment dependency including temperature dependency. Furthermore, a transport system for AMOLED deposition is introduced as a typical application of gap sensors, which are recently receiving considerable attention. Based on the analyses, the proposed differential Hall effect gap sensor is found to be the most suitable gap sensor for precise gap sensing, especially for application to a transport system for AMOLED deposition. The sensor shows resolution of $0.63mV/{\mu}m$ for the overall range of the gap from 0 mm to 2.5 mm, temperature dependency of $3{\mu}m/^{\circ}C$ from $20^{\circ}C$ to $30^{\circ}C$, and a monotonic characteristic for the gap between the sensor and the target.

Fabrication and Characteristics of Micro Platform for Micro Gas Sensor with Low Power Consumption (마이크로 가스센서의 저전력 구동을 위한 마이크로 플랫폼의 제작과 특성)

  • Jang, Woong-Jin;Park, Kwang-Bum;Kim, In-Ho;Park, Soon-Sup;Park, Hyo-Derk;Lee, In-Kyu;Park, Joon-Shik
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.317-321
    • /
    • 2011
  • A Micro platform for micro gas sensor consisted of micro heater, insulator, and sensing electrode on 2 ${\mu}m$ thick $SiN_x$ membrane. Three types of micro platforms were designed and fabricated with membrane sizes. Total size of micro platform was 2.6 mm by 2.6 mm. Measured power consumptions were 28 mW, 28 mW, and 32.5 mW for Type 1, Type 2, and Type 3. At this moment, temperatures of membranes on the platforms were $295^{\circ}C$, $297^{\circ}C$, and $296^{\circ}C$, respectively. Fabricated micro platform considered appropriate to apply for low power consumption micro gas sensor. Micro gas sensors were prepared by the sequence that $SnO_2$ nanopowder pastes were dropped on membrane of Type 1 platforms, dried in oven, heat-treated with micro heaters in platforms. One of the micro gas sensors was tested for gas response to 1157 ppm, 578 ppm, and 231 ppm of methane and 1.68 ppm, 0.84 ppm, and 0.42 ppm of $NO_2$.

Enhanced Secure Sensor Association and Key Management in Wireless Body Area Networks

  • Shen, Jian;Tan, Haowen;Moh, Sangman;Chung, Ilyong;Liu, Qi;Sun, Xingming
    • Journal of Communications and Networks
    • /
    • v.17 no.5
    • /
    • pp.453-462
    • /
    • 2015
  • Body area networks (BANs) have emerged as an enabling technique for e-healthcare systems, which can be used to continuously and remotely monitor patients' health. In BANs, the data of a patient's vital body functions and movements can be collected by small wearable or implantable sensors and sent using shortrange wireless communication techniques. Due to the shared wireless medium between the sensors in BANs, it may be possible to have malicious attacks on e-healthcare systems. The security and privacy issues of BANs are becoming more and more important. To provide secure and correct association of a group of sensors with a patient and satisfy the requirements of data confidentiality and integrity in BANs, we propose a novel enhanced secure sensor association and key management protocol based on elliptic curve cryptography and hash chains. The authentication procedure and group key generation are very simple and efficient. Therefore, our protocol can be easily implemented in the power and resource constrained sensor nodes in BANs. From a comparison of results, furthermore, we can conclude that the proposed protocol dramatically reduces the computation and communication cost for the authentication and key derivation compared with previous protocols. We believe that our protocol is attractive in the application of BANs.

Humidity Sensor using Polyvinylpyrrolidone-Coated Mach-Zehnder Interferometer in Planar Lightwave Circuit (폴리비닐피롤리돈이 코팅된 마하젠더 간섭계 기반의 평판형 광도파로 습도센서)

  • Kim, Ju Ha;Kim, Myoung Jin;Jung, Eun Joo;Hwang, Sung Hwan;Lee, Woo Jin;Choi, Eun Seo;Rho, Byung Sup
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.5
    • /
    • pp.251-255
    • /
    • 2013
  • In this paper, the characteristics of a humidity sensor implemented by Mach Zehnder Interferometer (MZI) in a Planar Lightwave Circuit (PLC) have been designed and demonstrated. The humidity outside is detected with polyvinylpyrrolidone (PVP) coated on the etched arm of the MZI. The length of the etched arm is 10 mm and the PVP was coated by dip-coating into the etched region. As the refractive index of the PVP changes with the surrounding humidity, the PVP-coated humidity sensor presented changes in the interferogram depending on RH (Relative Humidity) around the PLC. The measured results show that the proposed humidity sensor works successfully in the range of 30% to 80% of RH.

Optimum Condition of Pencil Drawing Paper Sensor(PDPS) for Temperature Detecting (온도 감지용 연필 선 종이 센서 최적화 연구)

  • Kwon, Dong-Jun;Shin, Pyeong-Su;Kim, Jong-Hyun;Beak, Young-Min;Park, Ha-Sung;Park, Joung-Man
    • Journal of Adhesion and Interface
    • /
    • v.18 no.1
    • /
    • pp.1-7
    • /
    • 2017
  • This study is about basic sensor experiment using PDPS by common pencil. 20 mm length, 3 mm thickness of line using 4B pencil is optimum condition. In order to be stable at point of contact between pencil line and copper wire, silver paste is needed. At using the PDPS, thermal detecting is able and thermal properties is inversely proportional to electrical resistance in the based on empirical formula. The sensor can be also used in the composites mold via the empirical formula by the relationship between thermal impact and electrical resistance. The change of electrical resistance relates the interfacial property of composites. It leads to expectation of properties.