• Title/Summary/Keyword: Sensor embedded type

Search Result 86, Processing Time 0.027 seconds

Current Developments of Biomedical Mobile Devices for Ubiquitous Healthcare (u-Healthcare를 위한 바이오 단말기의 개발 현황)

  • Lee, Tae-Soo;Hong, Joo-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.3
    • /
    • pp.185-190
    • /
    • 2009
  • Biomedical mobile devices for ubiquitous healthcare consist of biomedical sensors and communication terminal. They have two types of configuration. One is the sensor-network type device using wired or wireless communication with intelligent sensors to acquire biomedical data. The other is the sensor embedded type device, where the data can be acquired directly by itself. There are many examples of sensor network type, such as, fall detection sensor, blood glucose sensor, and ECG sensors networked with commercial PDA phone and commercial phone terminal for ubiquitous healthcare. On the other hand, sensor embedded type mounts blood glucose sensor, accelerometer, and etc. on commercial phone. However, to enable true ubiquitous healthcare, motion sensing is essential, because users go around anywhere and their signals should be measured and monitored, when they are affected by the motion. Therefore, in this paper, two biomedical mobile devices with motion monitoring function were addressed. One is sensor-network type with motion monitoring function, which uses Zigbee communication to measure the ECG, PPG and acceleration. The other is sensor-embedded type with motion monitoring function, which also can measure the data and uses the built-in cellular phone network modem for remote connection. These devices are expected to be useful for ubiquitous healthcare in coming aged society in Korea.

Data-centric Sensor Middleware for Heterogeneous Sensor Networks (이기종 센서 네트워크를 위한 데이터 중심적 센서 미들웨어)

  • Nam, Choon-Sung;Shin, Dong-Ryeol
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.7 no.6
    • /
    • pp.323-330
    • /
    • 2012
  • Wireless sensor networks need middleware system for efficiently managing the constrained resource and sensing data because they need different sensing data type and protocol to communicate with heterogeneous sensor networks. Thus this paper proposes data-centric sensor middleware for heterogeneous sensor networks. The proposed middleware have to support various query processing of user applications, high-level request of users, manage heterogeneous sensor systems and universal sensing data type for node and user application.

Implementation of ARM11 Platform for Gas Sensor Based on Embedded Linux (Embedded Linux를 기반으로 한 Gas센서용 ARM11 플랫폼 구현에 관한 연구)

  • Ahn, Jong-Chan;Kim, Young-Kil;Na, Sang-Sin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.7
    • /
    • pp.1335-1343
    • /
    • 2009
  • This paper focuses on the implementation of hand held typeARM11 Platform for gas sensor based on Embedded Linux OS. The S3C6400, which is ARM11 architecture based, is the key component of the ARM11 Platform, Bluetooth is adapted to consist the network for the wireless transmission of environmental data between a sensor node and hand held type ARM11 Platform. Linux is ported to the Platform, QT/embedded is used for the application development.

Design and Fabrication of a Micro Gas Sensor Using Nano Sensing Materials on Multi-layer Type Micro Platform with Low Power Consumption (마이크로 플랫폼 상에 나노 감지 재료를 이용한 저전력 NOX 센서의 설계 및 제조)

  • Park, Sang-Il;Park, Joon-Shik;Lee, Min-Ho;Park, Kwang-Bum;Kim, Seong-Dong;Park, Hyo-Derk;Lee, In-Kyu
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.2 no.2
    • /
    • pp.76-81
    • /
    • 2007
  • A novel multi-layer type micro gas sensor for $NO_X$ detection was designed and fabricated. Micro platform defined as type II-1 in this article for micro gas sensor was fabricated using the MEMS technology to meet the demanding needs of lower power consumption. Nano composite materials were fabricated with nanosized tin oxide powder and $\underline{m}$ulti-$\underline{w}$all $\underline{c}$arbon $\underline{n}$ano $\underline{t}$ube (MWCNT) to improve sensitivity. We investigated characteristics of fabricated multi-layer type micro gas sensor with $NO_2$ concentration variations at constant 2.2 V. Sensitivity (S) of micro gas sensor were observed to increase from 2.9, to 7.4 and 11.2 as concentrations of $NO_2$ gases increased from 2.4 ppm, to 3.6 ppm and 4.9 ppm. When 2.4 ppm of $NO_2$ gas was applied, response time and recovery time of micro gas sensor were recorded as 101 seconds and 142 seconds, respectively.

  • PDF

Strain Analysis in GFRP Cross-Ply Laminates Using TR-EFPI Optical Fiber Sensor (광섬유 TR-EFPI 센서를 이용한 GFRP 직교 적층판의 변형률 해석)

  • 우성충;최낙삼;권일범
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.10a
    • /
    • pp.150-153
    • /
    • 2003
  • Longitudinal strains({$varepsilon}_x$) of the core and skin layers in glass fiber reinforced plastic(GFRP) cross-ply composite laminates have been studied using the embedded optical fiber sensor of totally-reflected extrinsic Fabry-Perot interferometer(TR-EFPI). Foil-type strain gauges bonded on both the upper and lower surfaces were used for the measurement of the surface strains. Both TR-EFPI sensor and strain gauge bonded on the specimen surface showed excellent agreement within -0.0086 ~ +0.0302% strain. It was shown that values of {$varepsilon}_x$ in the interior of the surface layer and the core layer measured by embedded TR-EFPI sensor was significantly higher than that of the specimen surface measured by strain gauges. The experimental results were ascertained with finite element analysis. Embedded TR-EFPI optical fiber sensor could measure accurately the internal strains which were different from the surface.

  • PDF

Implementation of Low-Power Ubiquitous Health System based on Real-Time Embedded Linux using ZigBee wireless communication (ZigBee를 이용한 실시간 임베디드 리눅스 기반의 저전력형 U-Health 시스템 구현)

  • Kwon, Jong-Won;Ayurzana, Odgerel;Park, Yong-Man;Koo, Sang-Jun;Kim, Hie-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.436-438
    • /
    • 2007
  • As the sensors and communication technology get advance, the remote health diagnosis for patients and senior persons at home are possible now without visiting doctors in hospitals. A low-power ubiquitous health check device was developed adapting Real-Time Embedded Linux is developed. This ubiquitous device is consisted of three sensors. The wrist type health checking terminal acquires periodically the health data by using a blood pressure sensor, a pulse sensor and a body temperature sensor. It transmits the health data to the access point located at the home center through the ZigBee wireless communication modem. This health data collector or access point device sends the data again to the main server operated in a hospital or health care organization. The health server control continuously the input data and sends an alarm signal to the assigned. doctor and responsible persons using cellular SMS when any dangerous events occur. This wrist type health check device has an embedded linux OS using Intel PAX255 MPU. The developed U-Health system is applicable for checking patients health in remote at home. And their family or related persons in remote site can check the patients health status at any time. They can be assured by receiving SMS record and alarm of emergency case which is transmitted from the health server.

  • PDF

Realtime Detection of Damage in Composite Structures by Using PVDE Sensor (압전고분자 센서를 이용한 복합재 구조의 실시간 손상탐지)

  • ;Y. A. Dzenis
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2002.10a
    • /
    • pp.118-121
    • /
    • 2002
  • Polyvinylidene di-fluoride (PVDF) film sensor appeared to be practically useful for the structural health monitoring of composite materials and structures. PVDF film sensors were either attached to or embedded in the graphite/epoxy composite (CFRP) samples to detect the fatigue damage at the bondline of single-lap joints or the tensile failure of unidirectional laminates. PVDF sensors were sensitive enough to detect and determine the crack front in linear location since composites usually produce very energetic acoustic emission (AE). PVDF sensors are extremely cost-effective, as flexible as other plastic films, in low profile as thin as a few tens of microns, and have relatively wide-band response, all of which characteristics are readily utilized for the structural health monitoring of composite structures. Signals due to fatigue damage showed a characteristics of mode II (shear) type failure whereas those from fiber breakage at DEN notches showed that of mode I (tensile) type fracture.

  • PDF

Embedded EM Sensor for Tensile Force Estimation of PS tendon of PSC Girder (PS 긴장재 긴장력 계측을 위한 PSC 거더 내부 매립용 EM 센서)

  • Park, Jooyoung;Kim, Junkyeong;Zhang, Aoqi;Lee, Hwanwoo;Park, Seunghee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.6
    • /
    • pp.691-697
    • /
    • 2015
  • In this paper, an embedded EM sensor was researched to estimate prestressing force of PS tendon in PSC girder. Recent methodologies for managing prestressing force loss were staying on verifying a applying prestressing force under construction, namely the loss management can not be controlled after construction. To estimate the tensile force of PS tendon during lifetime of PSC girder, this research proposed a bobbin-type embedded EM sensor that can be embedded in PSC girder is designed and fabricated considering the shape properties of anchorage zone and sheath. To verify the proposed sensor, a small PSC girder test was performed. The embedded EM sensor was connected to a sheath and anchor block, and the concrete was poured. After curing, the change of the permeability of PS tendon under tensile forces of 200, 710, 1070, 1300kN was measured using embedded EM sensor. The permeability of PS tendon had decreased according to the increment of applied tensile force. Also it is confirmed that the change of permeability due to applied tensile force could resolve the applied tensile force values. As a result, proposed embedded EM sensor could be embed into the PSC girder and it could be used to estimate the tensile force variation during lifetime of PSC girder.

Investigations of process factors in the sensitivity of embedded digital switching TSP

  • Han, Sang-Youn;Oh, Keun-Chan;Seong, Dong-Gi;Ham, Yeon-Sik;Lyu, Jae-Jin;Cho, Young-Je
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1531-1534
    • /
    • 2009
  • Effect of process factors on the sensitivity of inner-type digital switching TSP was analyzed. From these results, we have successfully fabricated inner-type digital switching TSP embedded in 3.2-inch WQVGA PLS mode LCD panel. During many factors, TFT sensor structure for reducing the PI thickness and a separation distance of $0.3{\mu}m$ between the conductive column spacer (C/S) and TFT sensor were essential. Glass thickness and main C/S density were also important factors. This technology can be applied to wide angle of view hand-held phones, personal digital assistants (PDAs), and tablet PCs.

  • PDF

A Sensor Value Validation Technique taking account of the Error Propagation among the Sensor Values in Causal Relation (인과관계내에서 계측값들의 오차파급을 고려한 계측값 검증 기법에 관한 연구)

  • Lee, S.C.;Uh, R.J.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2275-2277
    • /
    • 1998
  • This paper presents an algorithmic sensor value validation technique that can systematically explore the embedded sensor redundancies in complex physical systems and maximize their utilization in validating sensor values. The confidency criteria are developed for checking the consistency of sensor relationships called Causal Relations. Development results are applied to a tubular type supercritical pressure type thermal power plant with rated operational data to demonstrate the effectiveness of the proposed technique.

  • PDF