• Title/Summary/Keyword: Sensor Sensitivity

Search Result 1,898, Processing Time 0.033 seconds

Investigation of Feasibility of Tunneling Field Effect Transistor (TFET) as Highly Sensitive and Multi-sensing Biosensors

  • Lee, Ryoongbin;Kwon, Dae Woong;Kim, Sihyun;Kim, Dae Hwan;Park, Byung-Gook
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.17 no.1
    • /
    • pp.141-146
    • /
    • 2017
  • In this letter, we propose the use of tunneling field effect transistors (TFET) as a biosensor that detects bio-molecules on the gate oxide. In TFET sensors, the charges of target molecules accumulated at the surface of the gate oxide bend the energy band of p-i-n structure and thus tunneling current varies with the band bending. Sensing parameters of TFET sensors such as threshold voltage ($V_t$) shift and on-current ($I_D$) change are extracted as a function of the charge variation. As a result, it is found that the performances of TFET sensors can surpass those of conventional FET (cFET) based sensors in terms of sensitivity. Furthermore, it is verified that the simultaneous sensing of two different target molecules in a TFET sensor can be performed by using the ambipolar behavior of TFET sensors. Consequently, it is revealed that two different molecules can be sensed simultaneously in a read-out circuit since the multi-sensing is carried out at equivalent current level by the ambipolar behavior.

Preminary Study on Stress Analysis of Rock-mass Support Structure using Laboratory Test and Numerical Simulation (실내실험과 수치해석을 이용한 암반지보구조물의 응력거동 분석을 위한 기초 연구)

  • Lee, Jae-Ho;Moon, Hong-Deuk;Yoo, Ji-Hyeung;Kim, Hyuk;Son, Yeong-Ju
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.825-831
    • /
    • 2010
  • In this study is stress behavior of steel support structure is to identify basic research. Steel stress due to load step to determine the behavior of steel using strain gauge steel loading test was performed. Numerical analysis and steel loading test using strain gauge on the actual steel stress behavior was analyzed. First, when tensile loading 3.5tonf load side of the plastic behavior appeared. Elastic model, using numerical analysis and comparison of results, the actual value is saved and you can see some difference. This repeated loading tests on steel can be seen from the results of the stress behavior of the steel rather than the elastic behavior of elastic-plastic behavior is because you can see. In addition, the upper and lower steel stress in compression and tension behavior represents the behavior was similar, but different. Steel loading test results, Y-axis get a compression if X-axis is tension. The future based on this study, the stress sensitivity curve of magnetic anisotropy sensor for non-destructive stress measurement technique for the study will be performed. And the behavior of plastic zone and residual stress to determine the numerical analysis using non-elastic model is needed.

  • PDF

The development of pH reading system based on vision system (영상 기반 pH 산도 측정 시스템 개발)

  • Moon, Ha-Jung;Lee, Dong-Hoon
    • Journal of IKEEE
    • /
    • v.17 no.4
    • /
    • pp.398-406
    • /
    • 2013
  • Nuclear medicine imaging devices such as PET diagnose disease after injecting radiopharmaceuticals in human body for diagnosis. Radiopharmaceuticals should maintain the proper pH for human body safety. In general, pH paper is used to measure the pH of the radiopharmaceutical. pH of the sample compared with the standard color chart is used for measurement. However, the pH reading difference according to the experience of a rater can be generated. Also, a pH meter for measuring pH has a high sensitivity and contamination of the sensor must be avoided. In this paper, we developed the new hardware device for pH reading method and software was developed with vision algorithm to measure pH easily and simply.

Fast Simulation of Output Voltage for High-Shock Piezoresistive Microaccelerometer Using Mode Superposition Method and Least Square Method (모드중첩법 및 최소자승법을 통한 고충격 압저항 미소가속도계의 출력전압 해석)

  • Han, Jeong-Sam;Kwon, Ki-Beom
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.7
    • /
    • pp.777-787
    • /
    • 2012
  • The transient analysis for the output voltage of a piezoresistive microaccelerometer takes a relatively high computation time because at least two iterations are required to calculate the piezoresistive-structural coupled response at each time step. In this study, the high computational cost for calculating the transient output voltage is considerably reduced by an approach integrating the mode superposition method and the least square method. In the approach, data on static displacement and output voltage calculated by piezoresistive-structural coupled simulation for three acceleration inputs are used to develop a quadratic regression model, relating the output voltage to the displacement at a certain observation point. The transient output voltage is then approximated by a regression model using the displacement response cheaply calculated by the mode superposition method. A high-impact microaccelerometer subject to several types of acceleration inputs such as 100,000 G shock, sine, step, and square pulses are adopted as a numerical example to represent the efficiency and accuracy of the suggested approach.

Development of a Dual Axial Gyroscope with Piezoelectric Ceramics (압전세라믹을 이용한 2축형 회전센서 개발)

  • Ryoo, Hye-Ok;Lee, Young-Jin;Roh, Yong-Rae
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.6
    • /
    • pp.61-67
    • /
    • 1997
  • Piezoelectric gyroscopes are the devices to measure angular rotational velocity of a system with respect to an inertial frame of reference means of the Coriolis principle. Most of current piezoelectric gyroscopes detect rotational velocity about a single axis of rotation. This paper describes development of a new dual axial gyroscope made out of the piezoelectric ceramic, PZT, which can overcome the limitation of the current single axial type. The validity of the new structure is checked through finite element analysis. Based on the design, an experimental sample of the sensor is fabricated and its performance is discussed in comparison with the theoretical expectation. The resutls show that the present gyroscope is capable of measuring the rotational velocity over two orthogonal axes simultaneously with good enough sensitivity and distinction between the two axial components of the rotation.

  • PDF

A Study on Boesun -On the Comparison of the Basic Patterns of Boesun- (한복 버선에 관한 연구 -버선 원형의 비교를 중심으로-)

  • Moon Meyng Ok;Kim Ya Ji
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.9 no.2
    • /
    • pp.45-55
    • /
    • 1985
  • The main purpose of this study is to investigate the suitability of Boesun (the Korean Socks) to the foot. In order to find the problem of Boesun, I made up the questionnaire. The suitabltity of Boesun to the foot was experimented by 'the replica method', 'the fuse method' and 'the deform painting method'. The pressure of Boesun to the foot was measured by utilizing a human sensitivity as a sensor. The results were as follows. 1. In the questionnaire, the fore part of Boesum was uncomfortable by the pressure. 2. The surface area of Boesun was generally smaller than the surface area of the foot, but the ratio of two surface area related closely to the individual. 3. At the cross-sections from No. 1 to No. 10, the breadth of the worn Boesun was smaller than the breadth of the foot. Because of the smaller breadth of the worn Boesun, the foot was get the pressure at the fore part of Boesun. This result accorded with the result of the questionnaire. 4. The location of the deformation by 'deform painting method' was almost the fore part of Boesun. 5. The pressure of Kwon's Boesun was 2.57$\~$2.99kg, the pressure of Kim's Boesun was 1.31$\~$1.74 kg and the pressure of Lee's Boesun was 3.42$\~$3.88kg. Compared with the distribution chart of the pressure, Kwon's Boesun was involved the back part of 'slightly pressured' and the fore part of 'pressured', Kim's Boesun was involved the fore part of 'slightly pressured' and Lee's Boesun was involved the middle part of 'pressured'.

  • PDF

Study on the Electro-Optic Characteristics of $CdS_{1-x}Se_{x}$ Photoconductive Thin Films ($CdS_{1-x}Se_{x}$ 광도전 박막의 전기-광학적 특성연구)

  • Yang, D.I.;Shin, Y.J.;Lim, S.Y.;Park, S.M.;Choi, Y.D.
    • Journal of Sensor Science and Technology
    • /
    • v.1 no.1
    • /
    • pp.53-57
    • /
    • 1992
  • We report the crystal growth and the electro-optic characteristics of $CdS_{1-x}Se_{x}$ thin films. $CdS_{1-x}Se_{x}$ thin films wire deposited on the alumina plate by electron beam evaporation technique in pressure of $1.5{\times}10^{-7}$ torr, voltage of 4kV, current of 2.5mA and substrate temperature of $300^{\circ}C$. The deposited $CdS_{1-x}Se_{x}$ thin films were proved to be a polycrystal with hexagonal structure through X-ray diffraction patterns. $CdS_{1-x}Se_{x}$ photoconductive films showed high photoconductivity after annealing at $550^{\circ}C$ for 30 minutes. And the films have been investigated the Hall effect, photocurrent spectra, sensitivity, maximum allowable power dissipation and response time.

  • PDF

Research on MFL PIG Design for the Inspection of Underground Gas Pipeline (지하매설 가스관의 검사를 위한 누설자속탐상 PIG 설계에 관한 연구)

  • Park, Sang-Ho;Park, Gwan-Soo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.2
    • /
    • pp.177-186
    • /
    • 2002
  • This paper describes the magnetic flux leakage(MFL) type non-destructive testing(NDT) system to detect the 3D defects in underground gas pipe. Magnetic systems with permanent magnets and yokes are analyzed by 3D non-lineal finite element method(FEM) with optimum design. In case of under-saturation of gas pipe, sensing signals are too weak to detect. In case of over-saturation, the changes of the sensing signals are too low to detect the defects sensitively. So, the operating points of the magnetic system are optimized to increase the changes of the MFL signals. The effects of the depth and size of the defects on the sensing signals are analyzed to define the range and resolution of the MFL sensors. To increase the sensor's sensitivity, the back-yoke sensors are introduced and tested.

Electrochemical Detection of Hydrogen Peroxide based on Hemoglobin-DNA/pyterpy Modified Gold Electrode (Hemoglobin-DNA/pyterpy 박막을 이용한 과산화수소의 전기화학적 검출)

  • Lee, Dong-Yun;Choi, Won-Suk;Park, Sang-Hyun;Kwon, Young-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1295-1296
    • /
    • 2008
  • Hydrogen peroxide ($H_2O_2$) biosensor is one of the most developing sensors because this kind of sensors is highly selective and responds quickly to the specific substrate. Hemoglobin (Hb) has been used as ideal biomolecules to construct hydrogen peroxide biosensors because of their high selectivity to $H_2O_2$. The direct electron transfer of Hb has widely investigated for application in the determination of $H_2O_2$ because of its simplicity, high selectivity and intrinsic sensitivity. An electrochemical detection for hydrogen peroxide was investigated based on immobilization of hemoglobin on DNA/Fe(pyterpy)$^{2+}$ modified gold electrode. The pyterpy monolayers were firstly an electron deposition onto the gold electrode surface of the quartz crystal microbalance (QCM). It is offered a template to attach negatively charged DNA. The fabrication process of the electrode was verified by quartz crystal analyzer (QCA). The experimental parameters such as pH, applied potential and amperometric response were evaluated and optimized. Under the optimized conditions, this sensor shows the linear response within the range between $3.0{\times}10^{-6}$ to $9.0{|times}10^{-4}$ M concentrations of $H_2O_2$. The detection limit was determined to be $9{\times}10^{-7}$ M (based on the S/N=3).

  • PDF

Accuracy Evaluation of DEM Produced by using KOMPSAT-5 InSAR Image (KOMPSAT 5호 InSAR영상을 이용한 DEM제작 정확도 평가)

  • Han, Seung-Hee
    • Journal of Cadastre & Land InformatiX
    • /
    • v.47 no.2
    • /
    • pp.39-47
    • /
    • 2017
  • The SAR payload of the KOMPSAT-5 is equipped with an X-band (9.66GHz) microwave-based sensor. Especially, since it has a fixed antenna that can be electronically steered with respect to the azimuth and elevation planes, various applications are expected. This study evaluates the production performance and the accuracy of the DEM by producing DEM using the HR and UH mode images of KOMPSAT-5. To evaluate the production performance of the DEM, the sensitivity of DEM was assessed through a baseline analysis and $2{\pi}$ ambiguity; it was found to have good production performance. In addition, to evaluate the accuracy of the produced DEM, 30 check points were compared with SRTM data. As a result, STDEV ${\pm}15-20m$ accuracy was obtained. If the accuracy of the DEM is improved by adjusting the parameters of the filtering method or phase unwrapping method in the future, it will be possible to widely use the KOMPSAT-5 image for environmental and disaster monitoring.