• Title/Summary/Keyword: Sensor Connection

Search Result 297, Processing Time 0.026 seconds

Intelligent Diagnostic System of Photovoltaic Connection Module for Fire Prevention (화재 예방을 위한 태양광 접속반의 지능형 진단 시스템)

  • Ahn, Jae Hyun;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.3
    • /
    • pp.161-166
    • /
    • 2021
  • To prevent accidents caused by changes in the surrounding environment or other factors, various protection facilities are installed at the photovoltaic connection module. The main causes of fire are sparks due to foreign substances inside the photovoltaic connection module through high temperature rise and dew condensation in the photovoltaic connection module, and fire due to heat from the power diode. The proposed method can predict the fire by measuring flame, carbon dioxide, carbon monoxide, temperature, humidity, input voltage, and current on the photovoltaic connection module, and when the fire conditions are reached, fire alarm and power off can be sent to managers and users in real time to prevent fire in advance.

A Connection Setup Scheme to Mobile Sink in Sensor Networks (센서 네트워크에서 이동싱크로의 연결설정 방안)

  • Park, Sang-Joon;Lee, Jong-Chan;Kim, Hyung-Jong
    • Journal of the Korea Society for Simulation
    • /
    • v.17 no.1
    • /
    • pp.9-16
    • /
    • 2008
  • The sink mobility can request frequent routing change in sensor networks. By active mobility a sink can gather needed information easily so that the network availability will be higher. However, instead static sink system, the connection between sensor nodes and a mobile sink can be changed continuously. That is, the rerouting should be implemented caused by the routing alteration. It is two connection setups for the mobile sink system: the connection from sink to sensor nodes and the connection from sensor nodes to sink. However, sensor nodes actually have many functional limitations. Hence, the low cost scheme will be needed for the connection setup from sensor nodes to the mobile sink. In this paper, we propose an agent scheme to the connection setup from sensor nodes to the mobile sink. The agent scheme provides the reliable setup scheme to the connection by using an agent sector.

  • PDF

Performance evaluation of EMI interface and multi-channel wireless impedance sensor node for bolted connection monitoring (볼트 연결부 모니터링을 위한 다채널 무선 임피런스 센서노트와 EMI 인터페이스의 성능 분석)

  • Nguyen, Khac-Duy;Lee, Po-Young;Kim, Jeong-Tae
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2011.04a
    • /
    • pp.36-39
    • /
    • 2011
  • In this paper, performance of EMI interface and multi-channel wireless impedance sensor node is evaluated for SHM on bolted connection. To achieve the objective, following approaches are implemented. Firstly, an interface washer is designed to monitor loosened bolt through the variation in EMI of interface washer due to change in preload in bolt. Secondly, a multi-channel wireless impedance sensor node based on Imote2 platform is designed for automated and cost-efficient impedance-based SHM on bolted connections. Finally, performance of the multi-channel wireless impedance sensor node and the interface washer are experimentally validated for a lab-scale bolted connection model. A damage monitoring method using RMSD index of EMI signatures is utilized to examine the strength of each individual bolted connection.

  • PDF

A Development of CCTV Control System Based on Wireless Sensor Network (무선 센서 네트워크 기반 CCTV 제어 시스템 연구)

  • Cho, Soo-Hyung;Kim, Dae-Hwan
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.219-220
    • /
    • 2009
  • Many surveillance cameras used in security system are controlled with RS-485 communication protocol. In this situation, if RS-485 connection can be replaced with wireless connection using sensor network technology, an installation will become ease because of no wired connection and also a deployment of cameras will become free. This paper explains about the design of wireless sensor node and the necessary implementation for an operation, which can be replacing RS-485 connection for the development of CCTV control system based on wireless sensor network. The hardware platform of sensor node was designed based on MicaZ and the software was developed based on TinyOS. To control surveillance cameras deployed on wide area, the supporting of multi-hop also was implemented. With the result of experiment deploying on real environment, it was revealed that the controller could control cameras quickly with wireless.

  • PDF

Sensor Device Plug & Play for Ubiquitous Computing (유비쿼터스 컴퓨팅을 위한 센서 디바이스 Plug & Play)

  • Park, Jung-Sun;Eun, SeongBae;Yoon, Hyeon-Ju
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.7 no.3
    • /
    • pp.151-156
    • /
    • 2012
  • When mounting the sensor device in the way of Plug&Play, sensor device drivers need to be loaded and linked dynamically. Since a sensor node platform is based on small 8 bit MCU, dynamic loading and linking technique used in Windows and Linux can not be applied. In this paper, we present how to link and load dynamically sensor device drivers for sensor device Plug&Play. We implement a prototype and evaluate it to make sure that there is no performance degradation like sensor device driver connection speed and memory usage. Connection speed overhead increases to 0.2ms. Memory usage overhead increases to hundreds byte. It shows that there is no heavy influence in running the actual program.

Strong Connection Clustering Scheme for Shortest Distance Multi-hop Transmission in Mobile Sensor Networks (모바일 센서 네트워크에서 최단거리 멀티홉 전송을 위한 강한연결 클러스터 기법)

  • Wu, Mary
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.6
    • /
    • pp.667-677
    • /
    • 2018
  • Since sensor networks consist of sensor nodes with limited energy resources, so efficient energy use of sensor nodes is very important in the design of sensor networks. Sensor nodes consume a lot of energy for data transmission. Clustering technique is used to efficiently use energy in data transmission. Recently, mobile sink techniques have been proposed to reduce the energy load concentrated on the cluster header near a sink node. The CMS(Cluster-based Mobile sink) technique minimizes the generation of control messages by creating a data transmission path while creating clusters, and supports the inter-cluster one-hop transmission. But, there is a case where there is no connectivity between neighbor clusters, it causes a problem of having a long hop data transmission path regardless of local distance. In this paper, we propose a SCBC(Strong connection balancing cluster) to support the path of the minimum number of hops. The proposed scheme minimizes the number of hops in the data transmission path and supports efficient use of energy in the cluster header. This also minimizes a number of hops in data transmission paths even when the sink moves and establishes a new path, and it supports the effect of extending the life cycle of the entire sensor network.

Development of a Non-contacting Capacitive Sensor for Measurement of ${\mu}{\textrm}{m}$-order Displacements (마이크로미터 변위 측정을 위한 비접촉식 전기용량 센서 개발)

  • 김한준;이래덕;강전홍;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.768-771
    • /
    • 2001
  • Non-contacting capacitive sensor, based on principle of the cross capacitor, for measuring of $\mu\textrm{m}$-order displacements have been fabricated and characterized. To overcome disadvantages of the existed capacitive sensors of parallel type with 2-electrodes and 3-electrodes, the developed new sensor was designed to have 4-electrodes, two of them used high and low electrode the other two used as guard electrodes, on a sapphire plate with diameter 17 mm and thickness 0.7 mm, and are symmetrically situated with a constant gap of 0.2 mm between the electrodes. This sensor can be used for measuring the distance between sensor and target not only the metallic but also non-metallic target without ground connection.

  • PDF

Design and Implementation of Physical Computing Education Content based on Augmented Reality

  • Kim, So-Young;Jung, Eunmi;Kim, Heesun
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.14 no.4
    • /
    • pp.198-205
    • /
    • 2022
  • Along with a variety of coding education, physical computing education for controlling various sensors is being actively conducted for elementary, middle, and high school students in line with the era of the fourth industrial revolution. A problem with physical computing education using Arduino is pin connection errors between Arduino and various sensors. Most of the students who come into contact with the Arduino for the first time often do not know the purpose of the Arduino pin and the connection position of the pin. Also, hardware built with incorrect pin connections to the Arduino board often does not work properly. If this case continues, students will lose interest in coding education. Therefore, in this paper, we implemented an augmented reality application that informs the connection process of the Arduino board and the sensor during physical computing coding education using Arduino, and designed and implemented educational content for the Arduino pin position and connection process. First, we explain the role of the Arduino board and the sensor and the location of the pins. After that, the students run the educational augmented reality educational content using their smartphones and check the correct pin connection process between the Arduino and the sensor. In the physical computing education, augmented reality content is used to increase the understanding and immersion of the class. It is expected that the educational effect will also increase by inducing fun and interest in physical computing coding education.

Wireless Impedance-Based SUM for Bolted Connections via Multiple PZT-Interfaces

  • Nguyen, Khac-Duy;Kim, Jeong-Tae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.3
    • /
    • pp.246-259
    • /
    • 2011
  • This study presents a structural health monitoring (SHM) method for bolted connections by using multi-channel wireless impedance sensor nodes and multiple PZT-interfaces. To achieve the objective, the following approaches are implemented. Firstly, a PZT-interface is designed to monitor bolt loosening in bolted connection based on variation of electro-mechanical(EM) impedance signatures. Secondly, a wireless impedance sensor node is designed for autonomous, cost-efficient and multi-channel monitoring. For the sensor platform, Imote2 is selected on the basis of its high operating speed, low power requirement and large storage memory. Finally, the performance of the wireless sensor node and the PZT-interfaces is experimentally evaluated for a bolt-connection model Damage monitoring method using root mean square deviation(RMSD) index of EM impedance signatures is utilized to estimate the strength of the bolted joint.

Self Sensing Reinforcement Combined with Fiber-Optic Sensor and FRP Strip for Structural Reinforcement (구조물 보강용 FRP 판과 광섬유 센서가 결합된 자기감지 보강재)

  • Song, Se-Gi;Seo, Soo-Yeon;Kim, Kang Su
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.8
    • /
    • pp.123-130
    • /
    • 2019
  • Recently, it is required to develop a monitoring technology that combines an FBG sensor as a means for continuously monitoring whether reinforcing effect of FRP is maintained on FRP reinforced structural members. However, most existing researches focus on the insertion of FBG sensors into bar-shaped FRPs, and there is insufficient study on the details strip-type FRPs combined with FBG sensors. Therefore, in this paper, it is studied to develop a reinforcement in which a FBG sensor is combined with a FRP strip. Especially, combination of FRP and FBG sensor. For this, a series of experiments were performed to find the adhesive strength of fiber-FRP-epoxy joints, the tensile strength of FBG sensor part with reflection-lattice, and the performance depending on the connection method of FRF and FBG sensor. As a result of the study, it was found that a minimum strength of $216.15N/mm^2$ is required for incorporating FBG sensors in FRP using epoxy. It is considered that the adhesion length of epoxy joints should be more than 50mm. When the FBG sensor is attached to the FRP strip as an epoxy, it is considered appropriate to use the complete attachment and the sensor non-attachment method.