• Title/Summary/Keyword: Sensor Arrangement

Search Result 105, Processing Time 0.039 seconds

Study of an Optical Goniometer Using a Multi-Photodiode Sensor

  • Kim, Ji-Sun;Kim, A-Hee;Oh, Han-Byeol;Kim, Jun-Sik;Goh, Bong-Jun;Lee, Eun-Suk;Choi, Ju-Hyeon;Baek, Jin-Young;Jun, Jae-Hoon
    • Journal of the Optical Society of Korea
    • /
    • v.20 no.1
    • /
    • pp.22-28
    • /
    • 2016
  • The monitoring and measurement of the motion of a human joint is very important in screening for degenerative brain diseases and tracking the rehabilitation process. Since there are various medical fields to benefit from angular motion measurement, the necessity for monitoring of human joint movement is increasing. In this study, the optical sensor is composed of a light emission unit with a red LED and an optical fiber, and a reception unit with an arrangement of three photodiodes. The angular detection range was widened with the use of multiple photodiodes and the developed algorithm. The result will be useful for designing an effective angular sensor with low cost and small size.

Study on EMI Elimination and PLN Application in ELF Band for Romote Sensing with Electric Potentiometer (전위계차 센서를 이용한 원격센싱을 위한 ELF 대역 EMI 제거 및 PLN 응용 연구)

  • Jang, Jin Soo;Kim, Young Chul
    • Smart Media Journal
    • /
    • v.4 no.1
    • /
    • pp.33-38
    • /
    • 2015
  • In this paper, we propose the methods not only to eliminate ELF(Extremely Low Frequency) EMI(Electro-Magnetic Interference) noice for extending recognition distance, but also to utilize the the PLN for detecting starting instance of a hand gesture using electric potential sensor. First, we measure strength of electric field generated in the smart devices such as TV and phone, and minimize EMI through efficient arrangement of the sensors. Meanwhile, we utilize the 60 Hz PLN to extract the starting point of hand gesture. Thereafter, we eliminate the PLN generated in the smart device and circuit of sensors. And then, we shield the sensors from an electric noise generated from devices. Finally, through analyzing the frequency components according to the gesture of target, we use the low pass filter and the Kalman filter for elimination of remaining electric noise. We analyze and evaluate the proposed ELF-band EMI eliminating method for non-contact remote sensing of the EPS(Electric Potential Sensor). Combined with a detecting technique of gesture starting point, the recognition distance for gestures has been proven to be extended to more than 3m, which is critical for real application.

Analysis and Control of Uniformity by the Feed Gate Adaptation of a Granular Spreader (입제비료 살포기의 출구조절에 의한 균일도의 분석과 제어)

  • Kweon, G.;Grift, Tony E.;Miclet, Denis;Virin, Teddy;Piron, Emmanuel
    • Journal of Biosystems Engineering
    • /
    • v.34 no.2
    • /
    • pp.95-105
    • /
    • 2009
  • A method was proposed which employed control of the drop location of fertilizer particles on a spinner disc to optimize the spread pattern uniformity. The system contained an optical sensor as a feedback mechanism, which measured discharge velocity and location, as well as particle diameters to predict a spread pattern of a single disc. Simulations showed that the feed gate adaptation algorithm produced high quality patterns for any given application rate in the dual disc spreader. The performance of the feed gate control method was assessed using data collected from a Sulky spinner disc spreader. The results showed that it was always possible to find a spread pattern with an acceptable CV lower than 15%, even though the spread pattern was obtained from a rudimentary flat disc with straight radial vanes. A mathematical optimization method was used to find the initial parameter settings for a specially designed experimental spreading arrangement, which included the feed gate control system, for a given flow rate and swath width. Several experiments were carried out to investigate the relationship between the gate opening and flow rate, disc speed and particle velocity, as well as disc speed and predicted landing location of fertilizer particles. All relationships found were highly linear ($r^2$ > 0.96), which showed that the time-of-flight sensor was well suited as a feedback sensor in the rate and uniformity controlled spreading system.

A Study on Foot Pressure by using an Insole Equipped with the Orthogonal Grid Sensor (직교 그리드 센서가 삽입된 인솔을 이용한 족압분포 연구)

  • Son, Jeong-Hyeop;Jun, In-Jun;Chang, Seung-Hwan
    • Composites Research
    • /
    • v.34 no.3
    • /
    • pp.161-166
    • /
    • 2021
  • In this study, we present a research method to develop a shoe that prevents foot injury by inducing the foot pressure. An orthogonal grid sensor was used to check the foot pressure in the upright standing position, and the change in the foot pressure distribution for various conditions was compared. We checked the conditions for distributing foot pressure efficiently by changing the spring constant of the spring inserted into the sole of the shoe and the foot pressure generated with or without the arch of the insole. In order to minimize the experimental error from the randomness of the human body's behavior, it is possible to predict through foot pressure under certain conditions through finite element analysis that simulates the pressure distribution. By checking the change of foot pressure according to the number and arrangement of springs through finite element analysis, conditions were established to provide more efficient foot pressure. The result can be used for designing footwear for patients with diabetic feet.

Development of a Polynomial Correction Program for Accuracy Improvement of the Geopositioning of High Resolution Imagery (고해상도 위성영상의 지상위치 정확도 개선을 위한 다항식 보정 프로그램의 개발)

  • Lee, Jin-Duk;So, Jae-Kyeong
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2007.04a
    • /
    • pp.135-140
    • /
    • 2007
  • Due to the expensiveness of IKONOS Pro and Precision Products, it is attractive to use the low-cost IKONOS Geo Product with vendor-provided RPCs to produce highly accurate mapping products. The imaging geometry of IKONOS high-resolution imagery is described by RFs instead of rigorous sensor models. This paper presents four different models defined respectively in object space and image space to improve the accuracies of the RF-derived ground coordinates. The four models include the offset model, the scale & offset model, the affine model and the 2nd-order polynomial model. Different configurations of ground control points (GCPs) are carefully examined to evaluate the effect of the GCPs arrangement on the accuracy of ground coordinates. The experiment also evaluates the effect of different cartographic parameters such as the number location, and accuracy of GCPs on the accuracy of geopositioning.

  • PDF

Communication device to use slight body movement for ALS patients

  • Fukuda, Yoshio;Yamanaka, Yuuki;Tanaka, Motohiro;Ishimatsu, Takakazu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1963-1967
    • /
    • 2003
  • Communication device to use slight movement for serious disabled is proposed. This device is developed mainly for patients suffering from ALS or a cerebral infarction. They often have communication difficulty because of deterioration of muscular functions. Features of this device are that the device is wearable on the user’s body and that it detects the movement of eyebrow. Because of these features, it is quite easy to install the sensor on the patient’s body, not like the conventional sensors. Furthermore, an adaptive communication software is incorporated. A feature of this software is that the arrangement and size of the button and window on the display can be optimized depending on the user's physical ability. In the field test it is confirmed that the communication device developed in this study is successfully helped the people with disability for increasing their communication ability.

  • PDF

Dispersive Delay Lines Based on the Use Of Narrow Open Metal Reflectors and Fan-Shaped Transducers

  • Lee, K.C.;Plessky, V.P.;Balashov, S.M.;Nam, C.W.;Kim, C.U.
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.408-412
    • /
    • 2012
  • An in-line dispersive delay line (DDL) demands low and controllable reflectivity of the reflectors, especially if the surface acoustic wave (SAW) propagates all the way along the reflecting structure. The metal reflectors are usually too strong and introduce too much attenuation in such a device. The proposed solution of this problem is to spatially separate the acoustic channels for different frequencies with the help of Fan-shaped Transducers (FIDT) and to use narrow open metal reflectors to reduce reflectivity. Special arrangement of FIDT is performed to use 180-deg. reflection of the SAW. Narrow open metal strips with a metallisation ratio of the order of 20% are used as reflectors with small and controllable reflectivity. Reflectivity of such strips is estimated both theoretically and experimentally. Experimental performance of the proposed DDL is presented.

A Study of Output Characteristics of Pressure Sensor based on Arrangement Pattern of Gages (후막저항의 기하학적 위치에 따른 압력센서의 출력특성 고찰)

  • Lee, Seong-Jae;Park, Ha-Young;Kim, Jae-Sung;Yoo, Jae-Tack;Min, Nam-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1497-1499
    • /
    • 2002
  • 본 논문에서는 세라믹 다이어프램식 압력센서를 설계하기 전에 세라믹 다이어프램의 변위에 대한 최적 조건을 확립하기 위해 세라믹의 기계적 특성, 다이어프램의 두께와 직경 등을 변화시키면서 중심부와 변곡점 부근에서 압력에 대한 다이어프램의 변위를 시뮬레이션 하였으며 결과를 이용하여 세라믹 다이어프램을 이용하고 후막저항을 센싱 부분으로 하여 4가지 형태의 기하학적인 출력특성을 고찰하였다.

  • PDF

A Study on Airborne LiDAR Calibration and Operation Techniques for Bathymetric Survey

  • Shin, Moon Seung;Yang, In Tae;Lee, Dong Ha
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.2
    • /
    • pp.113-120
    • /
    • 2016
  • The necessity of maritime sector for continuous management, accurate and update location information such as seabed shape and location, research on airborne LiDAR bathymetry surveying techniques are accelerating. Airborne LiDAR systems consist of a scanner and GPS/INS. The location accuracy of 3D point data obtained by a LiDAR system is determined by external orientation parameters. However, there are problems in the synchronization between sensors should be performed due to a variety of sensor combinations and arrangement. To solve this issue, system calibration should be conducted. Therefore, this study evaluates the system verification methods, processes, and operation techniques.

Novel design of interdigitated electrodes for piezoelectric transducers

  • Jemai, Ahmed;Najar, Fehmi
    • Smart Structures and Systems
    • /
    • v.22 no.4
    • /
    • pp.369-382
    • /
    • 2018
  • Novel design of interdigitated electrodes capable of increasing the performance of piezoelectric transducers are proposed. The new electrodes' geometry improve the electromechanical coupling by offering an enhanced adaptation of the electric field to the interdigitated electrode configuration. The proposed analysis is based on finite element modeling and takes into account local polarization effect. It is shown that the proposed electrodes considerably increase the strain generation compared to flat electrode arrangement used for Macro Fiber Composite (MFC) and Active Fiber Composite (AFC) actuators. Also, electric field singularities are reduced allowing better reliability of the transducer against electric failure.