• Title/Summary/Keyword: Sensitivity test

Search Result 2,827, Processing Time 0.031 seconds

An Experimental Investigation on The Contamination Sensitivity of An Automotive Fuel Pump (자동차 연료펌프의 오염민감도 실험 연구)

  • 이재천;장지현;신현명
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.6
    • /
    • pp.102-108
    • /
    • 2004
  • This study addresses the contamination sensitivity test of a typical fuel pump for automotive vehicle. The objective of the study is to find the contamination sensitivity coefficient of fuel pump on specific contaminant particle sizes so that optimal fuel filter could be selected. To achieve the objective, the degradation of discharge flow rate of fuel pump was measured under the experiments of various contaminants size ranges of ISO test dust up to 80${\mu}{\textrm}{m}$. The fundamental theory of contamination sensitivity was introduced and the contamination sensitivity coefficients were estimated using the experimental data. Maximum contamination sensitivity coefficient of $5{\times}10^{-6}$ L/minㆍEa was found on the contaminant size range of 40${\mu}{\textrm}{m}$∼50${\mu}{\textrm}{m}$. The magnified picture of the surface of vane disc revealed that the abrasive wear was the principal cause of discharge flow rate degradation. Hence, this study revealed that high efficiency filter on the contaminant particle size range of 30${\mu}{\textrm}{m}$∼70${\mu}{\textrm}{m}$ especially should be used to maintain the service lift of the fuel filter.

Mesh distortion sensitivity of 8-node plane elasticity elements based on parametric, metric, parametric-metric, and metric-parametric formulations

  • Rajendran, S.;Subramanian, S.
    • Structural Engineering and Mechanics
    • /
    • v.17 no.6
    • /
    • pp.767-788
    • /
    • 2004
  • The classical 8-node isoparametric serendipity element uses parametric shape functions for both test and trial functions. Although this element performs well in general, it yields poor results under severe mesh distortions. The distortion sensitivity is caused by the lack of continuity and/or completeness of shape functions used for test and trial functions. A recent element using parametric and metric shape functions for constructing the test and trial functions exhibits distortion immunity. This paper discusses the choice of parametric or metric shape functions as the basis for test and/or trial functions, satisfaction of continuity and completeness requirements, and their connection to distortion sensitivity. Also, the performances of four types of elements, viz., parametric, metric, parametric-metric, and metric-parametric, are compared for distorted meshes, and their merits and demerits are discussed.

Sensitivity of Dimensional Changes to Interfacial Friction over the Definite Range of Friction Factor in Ring Compression Test (링 압축시험에서 마찰인자 구간별 치수 변화의 민감도)

  • Lim, J.Y.;Noh, J.H.;Hwang, B.B.
    • Transactions of Materials Processing
    • /
    • v.19 no.8
    • /
    • pp.494-501
    • /
    • 2010
  • The main objective of this study is to examine the sensitivity of calibration curves of FEA of ring compression test to frictional shear factor. Ring compression test has been investigated by measuring dimensional changes at different positions of ring specimen and they include the changes in internal diameter at the middle and top section of the specimen, outer diameter at the middle and top section, surface expansion at the top surface, respectively. Initial ring geometries employed in analysis maintain a fixed ratio of 6 : 3 : 2, i.e. outer diameter : inner diameter : thickness of the ring specimen, which is generally known as 'standard' specimen. A rigid plastic material for different work-hardening characteristics has been modeled for simulations using rigid-plastic finite element code. Analyses have been performed within a definite range of friction as well as over whole range of friction to show different sensitivities to the interfacial friction for different ranges of friction. The results of investigation in this study have been summarized in terms of a dimensionless gradient. It has been known from the results that the dimensional changes at different positions of ring specimen show different linearity and sensitivity to the frictional condition on the contact surface.

Sensitivity Test on the Food Poisoning Bacteria of the Garlic Extract (마늘추출물의 식중독균에 대한 항균검사)

  • Yoon, In-Sook
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.2
    • /
    • pp.339-349
    • /
    • 2009
  • Garlic (Allium sativum, L.) has a long history of reputed value and actual use for its medicinal, antimicrobial, and pesticidal properties. This study was conducted to find possible developments to natural food preservatives from garlic extracts. Garlic extracts were prepared from fresh crushed garlic and diluted with sterilize distilled water. The sensitivity test was conducted to investigate the antimicrobial effect of garlic extract against six strains of food poisoning bacteria such as Staphylococcus aureus, Escherichea coli, Salmonella typhimurium, Vibrio parahemolyticus, Bacillus subtilis, and Listeria monocytogenes. The results of sensitivity test were then compared with those of Vancomycin and Imipenem which were used as treatment for G. (+) bacteria and G. (-) bacteria, respectively. All of the 6 tested strains exhibited strong or moderate activity. V. parahemolyticus exhibited susceptible only in undiluted solution, but not in diluted garlic extracts.

(WDF-Based Derivation of Two-Type-Interlaced Structure for Low-Sensitivity Digital Filter Realizations (WDF에 의거한 저면감도 영향교대 필터구조의 유도)

  • 임일택;이병기
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.8
    • /
    • pp.20-30
    • /
    • 1994
  • The lossless bounded real(LBR) two-pair cascade structure is one of the exiting low-sensitivity digital filter structures such as wave digital filters(WDFs) orthogonal filters. They are known to have the same structures which are composed of canonic building blocks interconnected to each other. The LBR two-pair cascade filters amount to describing in a unified manner the existing canonic low-sensitivity filters in terms of transfer matrices and chain matrices. However the existing structures have somewhat degraded low-sensitivity performance because they include dependent parameters within their structures. In this paper we propose a filter structure called “two-type-interlaced(TTI) structure.” eliminating such problem completely. This structures can be viewed as the WDFs of analog ladder circuits. As ladder circuits are obtained by cascading Brune sections and merging neighboring inductors or capacitors. so TTI structures at e obtained by cascading Type 3 LBR two-pairs and merging neighboring Type 1 LBR two-pairs. Next, a test procedure called “LBR test” is also presented in this paper. which determines whether of not the quantized TTI structure is stable . If it is unstable we can fine-tune the quantized parameters to make the overall structure stable. Therefore we can solve the dependent parameter problem completely with TTI structure along with LBR test. test.

  • PDF

Reliability of Stool Antigen Tests: Investigation of the Diagnostic Value of a New Immunochromatographic Helicobacter pylori Approach in Dyspeptic Patients

  • Korkmaz, Huseyin;Findik, Duygu;Ugurluoglu, Ceyha;Terzi, Yuksel
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.2
    • /
    • pp.657-660
    • /
    • 2015
  • Background: A diagnosis of H. pylori infection can be made by invasive or non-invasive methods. Several noninvasive diagnostic tests based on the detection of H. pylori stool antigen (HpSA) have been developed. The Genx H. pylori stool antigen card test is a new rapid, non-invasive test that is based on monoclonal immunochromatographic assay. The aim of this study was to determine its sensitivity, specificity, and diagnostic accuracy for diagnosing H. pylori infection in adult patients. Materials and Methods: A total of 162 patients were included in the study. A gastric biopsy was collected for histopathology and rapid urease testing. Stool specimens for HpSA testing were also collected. Patients were considered H. pylori positive if two invasive tests (histological and rapid urease tests) were positive. Results: Using the reference test, 50.6% of the samples were positive for H. pylori infection. The Genx H. pylori antigen test was positive in 19.7% of patients. The sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of the Genx H. pylori antigen test were 51.6%, 96.0%, 88.8%, 76.1%, and 79.0%, respectively. Conclusions: The Genx H. pylori stool antigen card test is a new non-invasive method that is fast and simple to perform but provides less reliable results.

Evaluation of Two ELISA and Two Indirect Hemagglutination Tests for Serodiagnosis of Pulmonary Hydatid Disease

  • Eris, Fatma Nur;Akisu, Ciler;Aksoy, Umit
    • Parasites, Hosts and Diseases
    • /
    • v.47 no.4
    • /
    • pp.427-429
    • /
    • 2009
  • To establish a definite diagnosis for pulmonary hydatid disease, combination of radiology and serology is useful. In this study, 19 preoperative sera from patients with surgically confirmed pulmonary hydatidosis, 40 sera from patients with other parasitosis and pulmonary diseases, and 20 sera from healthy donors were evaluated using 4 different serological tests, i.e., the commercial ELISA (ELISA-kit) test, the ELISA (ELISA-lab) test prepared in our laboratory, the commercial indirect hemagglutination assay kit (IHA-kit) test, and the IHA test using sensitized sheep red blood cells with tannic acid (IHA-TA). The ELISA-kit was the most sensitive (84.2%) and the most specific test (100.0%). The ELISA-kit also demonstrated the highest positive (100.0%) and negative (95.2%) predictive values. The sensitivity of the ELISA-lab test, that we prepared, was found to be 73.6%, whereas the IHA-kit test and the IHA-TA test were found to be 73.6% and 68.4%, respectively. The specificity of these tests was 96.6%, 98.3%, and 83.3%, respectively. When all 4 tests were assessed together, it was found that the sensitivity had risen to 94.7%. When the ELISA-kit was assessed with the IHA-kit and IHA-TA together, it was found that the sensitivity was 89.5% and 84.2%, respectively. Likewise, the combination of the ELISA-lab and IHA-kit or IHA-TA allowed us to achieve a sensitivity of 84.2% in cases of pulmonary echinococcosis. In conclusion, the diagnosis would be imminent if least 2 tests were applied together.

Evaluation of Bond Strength Characteristic of Moisture Induced Asphalt Mixtures using ABS Test (ABS Test를 이용한 아스팔트 혼합물의 수분에 의한 점착특성 평가)

  • Son, Jeong Tan;Yang, Sung Lin;Shin, O-Cheol;Rhee, Suk Keun;Im, Jeong Hyuk
    • International Journal of Highway Engineering
    • /
    • v.19 no.2
    • /
    • pp.87-95
    • /
    • 2017
  • PURPOSES : The objectives of this study are to evaluate moisture sensitivity of various asphalt mixtures and to suggest an alternate method for the dynamic immersion test, which is used to determine the application of anti-stripping agent, by analyzing bond strength. METHODS : The bond strength of various asphalt mixtures such as hot mix asphalt, warm mix asphalt, and polymer-modified asphalt was evaluated by the ABS test. In order to characterize moisture sensitivity at different temperatures of the mixtures, the ABS test was conducted at $-10^{\circ}C$, $5^{\circ}C$, $20^{\circ}C$, $40^{\circ}C$, and $54^{\circ}C$ under both dry and wet conditions. The concept of the bond strength ratio was applied for objective moisture sensitivity analysis. Moreover, the bond strength characteristic was compared to the dynamic immersion test to suggest an alternate method to determine the application of anti-stripping agent. RESULTS AND CONCLUSIONS : Overall, the polymer-modified asphalt demonstrates the highest bond strength characteristic regardless of moisture condition and temperature. The bond strength characteristic displays a highly reliable linear relationship from $5^{\circ}C$ to $40^{\circ}C$, and the relationship could be used to predict bond strength at any intermediate temperature. Based on the analysis of bond strength and retained asphalt ratio, the bond strength value of 1254 kPa could be applied as a criterion for anti-stripping agent.

Sensitivity Analysis of Hydrodynamic Derivatives on Characteristics of Manoeuvring Motion of Manta-type Unmanned Undersea Test Vehicle (Manta형 무인잠수정의 조종운동 특성에 미치는 유체력미계수의 민감도 해석에 관한 연구)

  • Bae, Jun-Young;Sohn, Kyoung-Ho
    • Journal of Navigation and Port Research
    • /
    • v.32 no.8
    • /
    • pp.603-609
    • /
    • 2008
  • Manta-type Unmanned Undersea Test Vehicle(MUUTV) is based on the same design concept as Unmanned Undersea Vehicle called Manta Test Vehicle(MTV), which was originally built and operated by the Naval Undersea Warfare Center(Lisiewicz et al., 2000, Sirmalis et al. 2001). The authors carried out the sensitivity analysis of the response of manoeuvring motion of MUUTV to changes in hydrodynamic derivatives, In order to calculate the sensitivity indices of hydrodynamic derivatives on MUUTV, the method by Sen(2000) was adopted Basically the dynamic mathematical model with six degrees of freedom by Feldman(1979) is used but a little revised, refered to Sohn et al.(2006) and some experiment in circulating water channel. Through the present research, some hydrodynamic derivatives of significance are found out, and also the numerical simulation using simplified mathematical model based on result of sensitivity analysis is ascertained to be enough for prediction of manoeuvring characteristics of MUUTV.

Social Face Sensitivity and Appearance Management Behaviors according to Sex Role Identity (성역할정체감에 따른 체면민감성과 외모관리행동)

  • Park, Eunhee
    • Journal of Fashion Business
    • /
    • v.16 no.5
    • /
    • pp.164-177
    • /
    • 2012
  • The purpose of this study was to classify sex role identity into groups and analyze the difference of social face sensitivity and appearance management behaviors by sex role identity. Questionnaires were administered to 306 people in their twenties and thirties living in Daegu Metropolitan City and Kyoungbuk province. The data was analyzed by using frequency, factor analysis, credibility, ${\chi}^2$-test, ANOVA, Duncan-test, and t-test. The findings were as follows. Sex role identity were classified into four groups (androgyny, masculineness, feminineness, and undifferentiation). Men in androgyny group showed the highest rate of 41.3% followed by undifferentiation(24.7%), masculineness(21.3%), and feminineness(12.7%). Women in undifferentiation group showed the highest rate of 35.9% followed by feminineness(24.4%), androgyny(23.7%), and masculineness(16.0%). Social face sensitivity were composed of four factors (consciousness of being embarrassed, social formality, other consciousness, and prestige). Appearance management behaviors were composed of six factors (skin management, fashion image management, plastic surgery management, weight management, hair management, and health management). According to the result of a significant difference between social face sensitivity and appearance management behaviors by sex role identity, male showed significant difference between the sub-variables of social face sensitivity factors (consciousness of being embarrassed, social formality, and other consciousness). Both of the male and female showed a significance of difference in consciousness of being embarrassed, and social formality. Male showed significant difference between the sub-variables of appearance management behaviors factors (fashion image management, weight management, hair management, and health management). Both of the male and female showed a significance of difference in fashion image management. Gender of twenties and thirties showed distinction between the sub-variables of social face sensitivity factors (consciousness of being embarrassed, and prestige) and appearance management behaviors (skin management, fashion image management, plastic surgery management, weight management, and hair management).