• Title/Summary/Keyword: Sensible Heat

Search Result 332, Processing Time 0.027 seconds

Drying Characteristics of 25 kW Class Industrial Dryer Adopting Mat Type Premixed Catalytic Burner (매트 형태의 예혼합 촉매 버너를 활용한 25 kW급 건조기의 성능 특성)

  • Ahn, Joon;Kim, Hyouck-Ju;Song, Kwang-Sup;Choi, Kyu-Sung;Song, Dae-Seok
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2856-2861
    • /
    • 2008
  • A catalytic burner has been developed to utilize thermal energy from the fossil fuel without nitrogen oxides (NOx) emission. The burner is shaped into a mat to maximize the heating surface. Premixed combustion has been developed to be used in a closed chamber, such as a radiation type industrial dryer. The burner yields the thermal energy in the form of thermal radiation in the infrared regime, which is proved to be effective to dry organic substances for low moisture condition. Thermal efficiency including the sensible heat is better correlated to the moisture compared to the dry rate.

  • PDF

Comparison of Land Surface Temperatures from Near-surface Measurement and Satellite-based Product

  • Ryu, Jae-Hyun;Jeong, Hoejeong;Choi, Seonwoong;Lee, Yang-Won;Cho, Jaeil
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.4
    • /
    • pp.609-616
    • /
    • 2019
  • Land surface temperature ($T_s$) is a critical variable for understanding the surface energy exchange between land and atmosphere. Using the data measured from micrometeorological flux towers, three types of $T_s$, obtained using a thermal-infrared radiometer (IRT), a net radiometer, and an equation for sensible heat flux, were compared. The $T_s$ estimated using the net radiometer was highly correlated with the $T_s$ obtained from the IRT. Both values acceptably fit the $T_s$ from the Terra/MODIS (Moderate Resolution Imaging Spectroradiometer)satellite. These results will enhance the measurement of land surface temperatures at various scales. Further, they are useful for understanding land surface energy partitioning to evaluate and develop land surface models and algorithms for satellite remote sensing products associated with surface thermal conditions.

Compensative Relationship Between Sensible and Latent Heat Fluxes in Surface Energy Partitioning (지표면 에너지 분배에서 현열과 잠열의 상보적인 움직임에 대한 고찰)

  • Kwanghun Choi;Kyungrock Paik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.44-44
    • /
    • 2023
  • 지표면 위 에너지 수지, 즉 순 복사에너지가 어떤 비율로 지열, 현열, 잠열로 분할되는지를 이해하는 것은 매우 중요한 문제이지만, 에너지 분할과 주변 환경 변수 사이의 인과관계를 역학적으로 설명하는 것은 난제로 남아있다. 이 연구에서는 지표면 에너지 분할에서 어떠한 조건에서라도 보편적으로 발견되는 특성을 찾아서 다양한 식생 조건에서 관측된 복사에너지 및 열 플럭스 관측소의 자료를 토대로 각 에너지 항의 시간 변동성을 분석했다. 시계열 분석을 위해 공분산 기법을 통해 관측한 현열 및 잠열 자료를 제공하는 Fluxnet 자료를 사용했으며, International Geosphere-Biosphere Programme (IGBP) 구분법에 따라 낙엽수림, 상록수림, 농지 및 사바나에 위치한 관측소의 자료를 비교 분석했다. 모든 관측소에서 에너지 수지에서 현열과 잠열의 합이 전체 순 복사에너지에서 차지하는 비중은 시간에 따라 큰 변화를 보이지 않는다는 특성을 발견했다. 하지만, 현열 또는 잠열이 차지하는 비중은 큰 계절성을 보여주고 있었다. 이를 종합하면 현열과 잠열이 상호보완적으로 발생한다는 것을 의미한다. 한편 시간에 따른 두 열 플럭스의 움직임은 해당 관측소 근처에서 서식하는 식생 특성과 깊게 관련됐음을 확인했다.

  • PDF

Case Study on Characteristics of Heat Flux Exchange between Atmosphere and Ocean in the case of cP Expansion accompanying Snowfall over the Adjacent Sea of Jeju Island (제주연안에 강설을 수반하는 대륙성 한기단 확장 시 대기와 해양간의 열교환 특성 사례 연구)

  • Kim Kyoung-Bo;Pang Ig-Chan;Kim Kil-Yap;Kim Dong-Ho;Lee Jimi
    • Journal of the Korean earth science society
    • /
    • v.26 no.5
    • /
    • pp.395-403
    • /
    • 2005
  • This study is focused on the relationship between snowfall and the Bowen’s Ratio (sensible heat flux/latent heat flux) through calculation of heat exchange between air and sea for snowfall events in Jeju Island from 1993 to 2003. The four weather stations for this study are located at Jeju, Seoguipo, Seongsanpo and Gosan in Jeju Island. In order to improve the reliability of snowfall forecast, the Bowen’s Ratio for snowfall, which includes influences from the atmosphere such as wind, is compared with the temperature difference between air and sea for snowfall. As a results, in the case for fresh snowfall, the minimum temperature differences between air and sea were 10, 12.3, 11.5, and $14.3^{\circ}C$ at Jeju, Seoguipo, Seongsanpo and Gosan, respectively. The probabilities of fresh snowfall were 26, 29, 13, and $23\%$, respectively, when the temperature differences were higher than the previous values. On the other hand, the minimum Bowen ratios were 0.59, 0.60, 0.65 and 0.65 at Jeju, Seoguipo, Seongsanpo and Gosan, respectively. The probabilities of fresh snowfall were 33, 70, 31 and $58\%$ respectively, when the Bowen ratio is higher than those. The reason for this is because the probability of fresh snowfall with the Bowen ratio was higher than the probability with temperature difference between air and sea. This result occurred because heat exchange by wind increased the probability of snowfall, along with the temperature difference between air and sea, and the Bowen ratio. Therefore, snowfall forecast of Jeju Island is significantly influenced by the sea, whereas forecast with Bowen ratio seems to have higher reliability than that with the temperature difference between air and sea. The data analysis for the ten-year period $(1993\~2002)$ showed that when each fresh snowfall was within 0.0 to 0.9cm, the average Bowen’s ratio was 0.63 to 0.67, and when each fresh snowfall was 1.0 to 4.9 cm, the average Bowen’s ratio was over 0.72. Therefore, fresh snowfall shows a proportional relationship with the Bowen’s ratio during snowfall.

Heat Transfer Characteristics for Inward Solidification in a Horizontal Cylinder Packed with P.C.M. (상변화물질을 충전한 수평원통관 내에서 응고시 열전달특성)

  • Yum, Sung-Bae;Hong, Chang-Shik;Lee, Chai-Sung
    • Solar Energy
    • /
    • v.11 no.2
    • /
    • pp.51-62
    • /
    • 1991
  • Heat transfer characteristics for heat retrieving processes in a paraffin-filled horizontal circular cylinder was studied. Theoretical and experimental analyses were carried out. In the theoretical analysis, solid and liquid phases were treated separately. Namely, convection for liquid and conduction for solid phase were investigated respectively. The retrieved heat was calculated from the experimentally determined solidified mass. Furthermore, the effects of initial temperature of the liquid and cooling temperature on the heat discharge rate were also studied. In the heat retrieving process, the governing factor for the solidifying rate is the cooling temperature, because most of the liquid sensible heat is rapidly discharged in the initial stage of solidification. Hence heat transfer mechanism during heat retrieving process can be safely considered as conduction. In the cut of frozen paraffin, there showed an empty space in the upper region. It is caused by the temperature drop in the liquid paraffin. While volume shrinkage caused by phase transition was indiscernible. Irrespective of cooling temperature and initial liquid temperature, solidified mass was well-correlated with the product of Fourier number and Stefan number in the solid phase.

  • PDF

Numerical Modeling for the Effect of High-rise Buildings on Meteorological Fields over the Coastal Area Using Urbanized MM5 (중/도시규모 기상모델을 이용한 고층건물군이 연안도시기상장에 미치는 영향 수치모델링)

  • Hwang, Mi-Kyoung;Oh, In-Bo;Kim, Yoo-Keun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.5
    • /
    • pp.495-505
    • /
    • 2012
  • Modeling the effects of high-rise buildings on thermo-dynamic conditions and meteorological fields over a coastal urban area was conducted using the modified meso-urban meteorological model (Urbanized MM5; uMM5) with the urban canopy parameterization (UCP) and the high-resolution inputs (urban morphology, land-use/land-cover sub-grid distribution, and high-quality digital elevation model data sets). Sensitivity simulations was performed during a typical sea-breeze episode (4~8 August 2006). Comparison between simulations with real urban morphology and changed urban morphology (i.e. high-rise buildings to low residential houses) showed that high-rise buildings could play an important role in urban heat island and land-sea breeze circulation. The major changes in urban meteorologic conditions are followings: significant increase in daytime temperature nearly by $1.0^{\circ}C$ due to sensible heat flux emitted from high density residential houses, decrease in nighttime temperature nearly by $1.0^{\circ}C$ because of the reduction in the storage heat flux emitted from high-rise buildings, and large increase in wind speed (maximum 2 m $s^{-1}$) during the daytime due to lessen drag-force or increased gradient temperature over coastal area.

Numerical Simulation on the Effect of the Land Coverage Change on the Urban Heat Budget (토지피복 변화가 도시열수지에 미치는 영향에 관한 수치시뮬레이션)

  • Kim, Sang-Ok;Yeo, In-Ae;Ha, Kyung-Min;Yee, Jurng-Jae;Yoon, Seong-Hwan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.176-179
    • /
    • 2009
  • In this study, Urban Climate Simulation was performed using 3-Dimensional Urban Canopy Model. The characteristics of urban thermal environment was analyzed by classifying land coverage and increasing natural land coverage ratio. The results are as follows. The characteristics of the land coverage on urban thermal environment formation can be summarized by the effects like higher temperature on the artificial coverage, and the contrary effects on the natural coverage. When the water coverage 100% was made up, maximum temperature was declined by $5.5^{\circ}C$, humidity by the 6.5g/kg, wind velocity by 0.6m/s, convective sensible heat by $400W/m^2$ and the evaporative latent heat was increased by $370W/m^2$ compared to when artificial coverage 100% was formed. These simulation results need to be constructed as DB which shows urban quantitative thermal characters by the urban physical structure. These can be quantitative base for suggesting combinations of the building and urban planning features at the point of the desirable urban thermal environment as well as analysing urban climate phenomenon.

  • PDF

Thermal Performance of an Enthalpy Exchanger Made of Paper at Different Outdoor Temperatures and Humidities (외기 온·습도 변화에 따른 종이재질 전열교환 엘리먼트 성능에 관한 연구)

  • Kim, Nae-Hyun;Lee, Eul-Jong;Song, Kil-Sup;Oh, Wang-Kyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.7
    • /
    • pp.697-702
    • /
    • 2010
  • An enthalpy exchanger in which heat and moisture transfer occur between the indoor and outdoor air operates at various outdoor conditions. In this study, the effect of the outdoor-air temperature and humidity on the performance of an enthalpy exchanger was experimentally investigated. An apparatus was specially-made to accurately measure the incoming and outgoing dry- and wet-bulb air temperatures as well as the flow rates. Tests were conducted in constant-temperature and constant-humidity chambers at different outdoor temperatures and humidities. It is shown that the effectiveness of latent-heat exchange increases as the relative humidity increases; further, this effect exhibited minimal dependence on the absolute humidity. However, the effectiveness of sensible-heat exchange is independent of both temperature and humidity

Simulations of Thermal Stratification of Daecheong Reservoir using Three-dimensional ELCOM Model (3차원 ELCOM 모형을 이용한 대청호 수온성층 모의)

  • Chung, Se Woong;Lee, Heung Soo;Choi, Jung Kyu;Ryu, In Gu
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.6
    • /
    • pp.922-934
    • /
    • 2009
  • The transport of contaminants and spatial variation in a deep reservoir are certainly governed by the thermal structure of the reservoir. There has been continuous efforts to utilize three-dimensional (3D) hydrodynamic and water quality models for supporting reservoir management, but the efforts to validate the models performance using extensive field data were rare. The study was aimed to evaluate a 3D hydrodynamic model, ELCOM, in Daecheong Reservoir for simulating heat fluxes and stratification processes under hydrological years of 2001, 2006, 2008, and to assess the impact of internal wave on the reservoir mixing. The model showed satisfactory performance in simulating the water temperature profiles: the absolute mean errors at R3 (Hoenam) and R4 (Dam) sites were in the range of $1.38{\sim}1.682^{\circ}C$. The evaporative and sensible heat losses through the reservoir surface were maximum during August and January, respectively. The net heat flux ($H_n$) was positive from February to September, while the stratification formed from May and continued until September. Instant vertical mixing was observed in the reservoir during strong wind events at R4, and the model reasonably reproduced the mixing events. A digital low-pass filter and zero crossing method was used to evaluate the potential impact of wind-driven internal wave on the reservoir mixing. The results indicated that most of the wind events occurred in 2001, 2006, 2008 were not enough to develop persistent internal wave and effective mixing in the reservoir. ELCOM is a suitable 3D model for supporting water quality management of the deep and stratified reservoirs.

An Experimental Study on the Performance of a Cross-Flow-Type, Indirect Evaporative Cooler Made of Paper/Plastic Film (종이와 플라스틱 필름의 이종 재질로 구성된 직교류형 간접증발소자의 성능에 대한 실험적 연구)

  • Kwon, Mi-Hye;Go, Min-Geon;Kim, Nae-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.9
    • /
    • pp.475-483
    • /
    • 2015
  • In Korea, a typically hot and humid summer means that air-conditioners consume a large quantity of electricity; accordingly, the simultaneous usage of an indirect evaporative cooler may reduce the sensible-heat level and save the amount of electricity that is consumed. In this study, the heat-transfer and pressure-drop characteristics of an indirect evaporative cooler made of paper/plastic film were investigated under both dry and wet conditions; for the purpose of comparison, an indirect evaporative cooler made of plastic film was also tested. Our results show that the indirect evaporative efficiencies under a wet condition are greater than those under a dry condition, and the efficiencies of the paper/plastic sample (109% to 138%) are greater than those (67% to 89%) of the plastic sample; in addition, the wet-surface, indirect evaporative efficiencies of the paper/plastic sample are 32% to 36% greater than those of the plastic sample. Further, the wet-surface pressure drops of the paper/plastic sample are 13% to 23% larger than those of the plastic sample, and this might have been caused by the surface roughness of the samples. A rigorous heat-transfer analysis revealed that, for the plastic sample, 30% to 37% of the wet channels remained dry, whereas all of the channels were wet for the paper/plastic sample.