• 제목/요약/키워드: Semi-Closed Space

Search Result 53, Processing Time 0.029 seconds

Interpretation of the Nok-U-dang, Traditional Upper-Class Mansion in Haenam -with Dweller's Life and Agricultural Production- (상류(上流) 전통주거(傳統住居) 해남(海南) 녹우당(綠雨堂)의 해석(解釋) -거주자(居住者) 생활(生活)과 농업경영(農業經營)으로-)

  • Lee, Hee-Bong;Lee, Hyang-Mee
    • Journal of architectural history
    • /
    • v.11 no.1 s.29
    • /
    • pp.65-84
    • /
    • 2002
  • This study has main purpose to understand and interpret the house Nok-U-dang, an upper class built in Chosun dynasty, not by outsider researcher's view but insider dweller's view. To interpret correctly, dweller's everyday life in the space and form is examined on a microscale beyond the physical space and form of the house, main object of architectural history To understand the present form exactly, the study restore traditional life in past era, 1940s. Main method of restoration is the ethnographic interview, based on cultural anthropology. Like any other upper-class house, the house has been influenced under ruling Confucian ideology in Chosun dynasty: separation of man's and woman's quarters and hierachical arrangement by generation, and worshipping ceremony for ancestor. However, it is by practical management for agricultural production that every court and building of the Noku-Dang can be explained correctly; preparing seed for sowing, tool storing, preparing and serving meal for laborers, making manure, harvesting, threshing grain, storing grain and so on. Precedent studies interpreted the house by the Confucian principle too much and made conclusion of dignity and austerity of ritual: woman's quarter, is closed and serene space. However this study shows that the space is semi-opened and composite space by agricultural works. And the Sarangchae, master's quarter, is located properly at visual center to control every agricultural activity.

  • PDF

Some properties of equivalent fuzzy norms

  • Rhie, Gil-Seob;Hwang, In-Ah
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.5 no.2
    • /
    • pp.175-178
    • /
    • 2005
  • In the present paper, we observe a relation between fuzzy norms and induced crisp norms on a linear space. We first prove that if $\rho_1,\;\rho_2$ are equivalent fuzzy norms on a linear space, then for every $\varepsilon\in(0.1)$, the induced crisp norms $P_\varepsilon^1,\;and\;P_\varepsilon^2$, respectively are equivalent. Since the converse does not hold, we prove it under some strict conditions. And consider the following theorem proved in [8]: Let $\rho$ be a lower semicontinuous fuzzy norm on a normed linear space X, and have the bounded support. Then $\rho$ is equivalent to the fuzzy norm $\chi_B$ where B is the closed unit ball of X. The lower semi-continuity of $\rho$ is an essential condition which guarantees the continuity of $P_\varepsilon$, where 0 < e < 1. As the last result, we prove that : if $\rho$ is a fuzzy norm on a finite dimensional vector space, then $\rho$ is equivalent to $\chi_B$ if and only if the support of $\rho$ is bounded.

Ways of Remodeling from the Traditional Hanok to the Modern Local Governmental Facility in 1910s - Focused on Architectural Drawings of the National Archives of Korea - (1910년대 근대적 지방관립시설로 사용된 한옥의 개조 방식 -국가기록원 소장 건축 도면의 분석을 통하여-)

  • Joo, Sang-Hun
    • Journal of architectural history
    • /
    • v.24 no.1
    • /
    • pp.7-16
    • /
    • 2015
  • The purpose of this study is to identify ways of remodeling from the traditional hanok to the modern local governmental facility in 1910s. Analysing architectural drawings in the National Archives of Korea, 58 hanok remodeling cases of 52 facilities were verified like the provincial office, county office, county court from 1907 to 1910s. Using hanok as the local governmental building, exterior walls were all changed to the scaled-wooden wall like one of western-wooden building in 1910s and the western-style entrance was set. Change of the plan caused by remodeling interior walls had an intention of the centralized closed plan. Remodeled semi-outer corridor using the space of the eave became changed to the inner corridor with expansion of space. Expansion of hanok for spatial demand was in three ways. First was the expansion towards the eave space, second was direct extension from hanok, and last was the use of external corridor to the new building. Using the eave space was simple but had limitation of space, it was planed with other expansion ways. The way of direct extension was usually used than the one with the corridor, because it was more economical way.

A Scheme for Computing Primary Fields in Modeling of Marine Controlled-Source Electromagnetic Surveys (해양전자탐사 모델링을 위한 1차장 계산법)

  • Kim, Hee-Joon
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.3
    • /
    • pp.185-190
    • /
    • 2011
  • In marine controlled-source electromagnetic (CSEM) modeling, it may be difficult to evaluate primary fields accurately using conventional linear filters because they decay very rapidly with distance. However, since there exists a closed-form solution to the Hankel transform in TM mode for a homogeneous half space, we can assess the accuracy of linear filters for evaluating the Hankel transform. As a result, only nine out of 36 source-receiver pairs show that EM fields decrease linearly in semi-log scale with an increase of source-receiver distance, while EM fields are either 0 or not reduced significantly due to an effect of the air layer. There also exist closed-form solutions for the nine pairs, and the others can be evaluated accurately with a relatively short filter. This paper proposes a method which uses closed-form solutions for TM-mode Hankel transforms and a filter with 61 coefficients for TE-mode ones.

A study on the smoke control performance of the damper exhaust system at FCEV fire in tunnel for small vehicles (소형차 전용터널 내 수소연료전지차 화재시 집중배기방식의 제연성능에 관한 연구)

  • Hong, Seo-Hee;Baek, Doo-San
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.6
    • /
    • pp.745-756
    • /
    • 2022
  • The road tunnel is a semi-closed space that is blocked on all sides except the entrance and exit, and in the event of a fire, the smoke of the fire spreads longitudinally due to heat buoyancy caused by the fire and air currents that always exist in the tunnel. To solve this problem, smoke removal facilities are installed in road tunnels to secure a safe evacuation environment by controlling the direction of movement of smoke or directly smoking at fire points. In urban areas, the service level of urban roads decreases due to the increase in traffic due to the increase in population, and as a solution, the construction of underground roads in urban areas is increasing. When a fire occurs during hydrogen leakage through TPRD of a hydrogen fuel cell vehicle (FCEV), the fire intensity depends on the amount of leakage, and the maximum fire intensity depends on the orifice diameter of the TPRD. Considering the TPRD orifice diameter of 1.8 mm, this study analyzed the diffusion distance of fire smoke according to the wind speed of the roadway and the opening interval of the large exhaust port when the maximum fire intensity was 15 MW. As a result, it was analyzed that air flow in the tunnel could be controlled if the wind speed of the road in the tunnel was less than 1.25 m/s, and smoke could be controlled within 200 m from the fire if the damper interval was 50 m and 100 m.

WEAK AND STRONG CONVERGENCE OF MANN'S-TYPE ITERATIONS FOR A COUNTABLE FAMILY OF NONEXPANSIVE MAPPINGS

  • Song, Yisheng;Chen, Rudong
    • Journal of the Korean Mathematical Society
    • /
    • v.45 no.5
    • /
    • pp.1393-1404
    • /
    • 2008
  • Let K be a nonempty closed convex subset of a Banach space E. Suppose $\{T_{n}\}$ (n = 1,2,...) is a uniformly asymptotically regular sequence of nonexpansive mappings from K to K such that ${\cap}_{n=1}^{\infty}$ F$\(T_n){\neq}{\phi}$. For $x_0{\in}K$, define $x_{n+1}={\lambda}_{n+1}x_{n}+(1-{\lambda}_{n+1})T_{n+1}x_{n},n{\geq}0$. If ${\lambda}_n{\subset}[0,1]$ satisfies $lim_{n{\rightarrow}{\infty}}{\lambda}_n=0$, we proved that $\{x_n\}$ weakly converges to some $z{\in}F\;as\;n{\rightarrow}{\infty}$ in the framework of reflexive Banach space E which satisfies the Opial's condition or has $Fr{\acute{e}}chet$ differentiable norm or its dual $E^*$ has the Kadec-Klee property. We also obtain that $\{x_n\}$ strongly converges to some $z{\in}F$ in Banach space E if K is a compact subset of E or there exists one map $T{\in}\{T_{n};n=1,2,...\}$ satisfy some compact conditions such as T is semi compact or satisfy Condition A or $lim_{n{\rightarrow}{\infty}}d(x_{n},F(T))=0$ and so on.

Analog active valve control design for non-linear semi-active resetable devices

  • Rodgers, Geoffrey W.;Chase, J. Geoffrey;Corman, Sylvain
    • Smart Structures and Systems
    • /
    • v.19 no.5
    • /
    • pp.487-497
    • /
    • 2017
  • Semi-active devices use the building's own motion to produce resistive forces and are thus strictly dissipative and require little power. Devices that independently control the binary open/closed valve state can enable novel device hysteresis loops that were not previously possible. However, some device hysteresis loops cannot be obtained without active analog valve control allowing slower, controlled release of stored energy, and is presents an ongoing limitation in obtaining the full range of possibilities offered by these devices. This in silico study develops a proportional-derivative feedback control law using a validated nonlinear device model to track an ideal diamond-shaped force-displacement response profile using active analog valve control. It is validated by comparison to the ideal shape for both sinusoidal and random seismic input motions. Structural application specific spectral analysis compares the performance for the non-linear, actively controlled case to those obtained with an ideal, linear model to validate that the potential performance will be retained when considering realistic nonlinear behaviour and the designed valve control approach. Results show tracking of the device force-displacement loop to within 3-5% of the desired ideal curve. Valve delay, rather than control law design, is the primary limiting factor, and analysis indicates a ratio of valve delay to structural period must be 1/10 or smaller to ensure adequate tracking, relating valve performance to structural period and overall device performance under control. Overall, the results show that active analog feedback control of energy release in these devices can significantly increase the range of resetable, valve-controlled semi-active device performance and hysteresis loops, in turn increasing their performance envelop and application space.

Stability Analysis of Tunnels Excavated in Squeezing Rock Masses (압출 암반내 굴착된 터널의 안정성해석)

  • 정소걸
    • Tunnel and Underground Space
    • /
    • v.13 no.4
    • /
    • pp.245-259
    • /
    • 2003
  • Refering to the articles "Squeezing rocks in tunnels(Barla, 1995)" and "Tunnelling under squeezing rock conditions(Barla 2002)" this article deals with technologies for design, stability analysis and construction of the tunnel being driven in the squeezing rock mass. The definition of this type of behavior was proposed by ISRM(1994). The identification and quantification of squeezing is given according to both the empirical and semi-empirical methods available to anticipate the potential of squeezing problems in tunnelling. Based on the experiences and lessons learned in recent years, the state of the art in modem construction methods was reported, when dealing with squeezing rock masses by either conventional or mechanical excavation methods. The closed-form solutions available for the analysis of the rock mass response during tunnel excavation are described in terms of the ground characteristic line and with reference to some elasto-plastic models for the given rock mass. Finally numerical methods were used for the simulation of different models and for design analysis of complex excavation and support systems, including three-dimensional conditions in order to quantify the influence of the advancing tunnel face to the deformation behavior of the tunnel.

A GENERIC RESEARCH ON NONLINEAR NON-CONVOLUTION TYPE SINGULAR INTEGRAL OPERATORS

  • Uysal, Gumrah;Mishra, Vishnu Narayan;Guller, Ozge Ozalp;Ibikli, Ertan
    • Korean Journal of Mathematics
    • /
    • v.24 no.3
    • /
    • pp.545-565
    • /
    • 2016
  • In this paper, we present some general results on the pointwise convergence of the non-convolution type nonlinear singular integral operators in the following form: $$T_{\lambda}(f;x)={\large\int_{\Omega}}K_{\lambda}(t,x,f(t))dt,\;x{\in}{\Psi},\;{\lambda}{\in}{\Lambda}$$, where ${\Psi}$ = and ${\Omega}$ = stand for arbitrary closed, semi-closed or open bounded intervals in ${\mathbb{R}}$ or these set notations denote $\mathbb{R}$, and ${\Lambda}$ is a set of non-negative numbers, to the function $f{\in}L_{p,{\omega}}({\Omega})$, where $L_{p,{\omega}}({\Omega})$ denotes the space of all measurable functions f for which $\|{\frac{f}{\omega}}\|^p$ (1 ${\leq}$ p < ${\infty}$) is integrable on ${\Omega}$, and ${\omega}:{\mathbb{R}}{\rightarrow}\mathbb{R}^+$ is a weight function satisfying some conditions.

A basic study for explosion pressure prediction of hydrogen fuel vehicle hydrogen tanks in underground parking lot (지하주차장 수소연료차 수소탱크 폭발 압력 예측을 위한 기초 연구)

  • Lee, Ho-Hyung;Kim, Hyo-Gyu;Yoo, Ji-Oh;Lee, Hu-Yeong;Kwon, Oh-Seung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.6
    • /
    • pp.605-612
    • /
    • 2021
  • Amid growing global damage due to abnormal weather caused by global warming, the introduction of eco-friendly cars is accelerating to reduce greenhouse gas emissions from internal combustion engines. Accordingly, many studies are being conducted in each country to prepare for the explosion of hydrogen fuel in semi-closed spaces such as tunnels and underground parking lots to ensure the safety of hydrogen-electric vehicles. As a result of predicting the explosion pressure of the hydrogen tank using the equivalent TNT model, it was found to be about 1.12 times and 2.30 times higher at a height of 1.5 meters, respectively, based on the case of 52 liters of hydrogen capacity. A review of the impact on the human body and buildings by converting the predicted maximum explosive pressure into the amount of impact predicted that all predicted values would result in lung damage or severe partial destruction. The predicted degree of damage was applied only by converting the amount of impact caused by the explosion, and considering the additional damage caused by the explosion, it is believed that the actual damage will increase further and safety and disaster prevention measures should be taken.