• 제목/요약/키워드: Sectional measurement

검색결과 406건 처리시간 0.031초

A study on the method of measurement of the standing-tree volume -Particularly concerning the method of measurement of the timber volume (입목재적(立木材積) 측정법(測定法)에 관(關)한 연구(硏究) -용재수목(用材樹木)의 재적측정법(材積測定法)을 중심으로)

  • Lee, Kwang Nam
    • Journal of Korean Society of Forest Science
    • /
    • 제3권1호
    • /
    • pp.28-31
    • /
    • 1963
  • Recognizing shortcomings and unreasonable points of the usual methods of measurement of the standing-tree volume, author contrived measurement formula of standing-tree volume which is based on stem-curve equation, $y^2=2px$, resulted from the analysises and experiments on stem-curve by differentiation & integration. The results of this study are as follows ; (1) The following is the formula. $V=1/2g_{1.2}$(h+1.2) V=volume of tree $g_{1.2}$ = sectional area at breast heigh h = height of tree (2) So plain is the form of this formula that this formula is more convenient than usual formulas in measuring. (3) The percentage error of this formula is negative and it is remarkably superior to usual formulas except Pressler's formula, in other words, the higher the tree that is measured is, the more inaccurate become pressler's formula, and the percentage error of the breast-height form factor method is direct proportion to the grossness of the tree that is measured, but the higher the tree that is measured, the lower become percentage error of this formula in geometrical progression.

  • PDF

A Comparative Study of Oswestry Back Pain Disability Questionnaire Versus Computer Adaptive Testing for Measuring Back Pain

  • Choi, Bong-Sam
    • Physical Therapy Korea
    • /
    • 제20권4호
    • /
    • pp.22-31
    • /
    • 2013
  • The aim of the present study was to compare measurement precisions of the Oswestry Back Pain Disability Questionnaire (ODQ) and a computer adaptive testing (CAT) method. The ODQ has been regarded as one of the most reliable condition-specific measure for back pain for decades. Cross-sectional study was carried out with two independent convenient samples from two out-patient rehabilitation clinics for back pain ($n_1=42$) and non-back pain group ($n_2=42$). Participants were asked to fill out the ODQ and CAT of International Classification of Functioning, Disability and Health-Activity Measure (ICF-AM). A series of Rasch analyses were performed to calculate person ability measures. The CAT measures had greater relative precision in discriminating the groups than did the ODQ measure in comparisons of the relative precision. The CAT measure appears to be more effective than did the ODQ measure in terms of measurement precision. By administering test items calibrated in a way, CAT measures using item response theory may promise a means with measurement precision as well as efficiency.

Development of Modeling Method of Hysteretic Characteristics for Accurate Load Measurement of Trucks (상용차량의 정확한 하중 측정을 위한 겹판스프링의 이력특성 모델링 기법 개발)

  • Seo, M.K.;Batbayar, E.;Shin, H.Y.;Lee, H.Y.;Ko, J.I.
    • Journal of Drive and Control
    • /
    • 제18권2호
    • /
    • pp.38-45
    • /
    • 2021
  • In recent years, the demand for an onboard scale system which can directly monitor load distribution and overload of vehicles has increased. Depending on the suspension type of the vehicle, the onboard scale system could use different types of sensors, such as, angle sensors, pressure sensors, load cells, etc. In the case of a vehicle equipped with leaf spring suspension system, the load of the vehicle is measured by using the deflection or displacement of the leaf spring. Leaf springs have hysteresis characteristics that vary in displacement depending on the load state. These characteristics cause load measurement errors when moving or removing cargoes. Therefore, this study aimed at developing an onboard scale device for cargo vehicles equipped with leaf springs. A sectional modeling method which can reduce measurement errors caused by hysteresis characteristics was also proposed.

Measurement of relative geomatric errors between mating parts by using an omnidirectional image sensing system (OISSA) (전방향센서(OISSA)를 이용한 조립물체사이의 상대오차의 측정)

  • 김완수;조형석;김성권
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.820-823
    • /
    • 1996
  • In contrast to parts of relatively simple shapes, it is important to match their cross-sectional shapes during mating parts of complicated shapes. It requires the 2.pi. information along their matching boundary to figure out their relative geometrical shapes. In this paper, we propose a method measuring a misalignment at the interface during mating parts with the complicated shapes by using the omnidirectional image sensing system(OLSSA). Also we carried out experiments in order to prove the method, and the results show the feasibility.

  • PDF

The Effect of the Axial Plane on Measurement of Available Bone Height for Dental Implant in Computed Tomography of the Mandible (하악의 전산화 단층사진에서 횡단면이 임플랜트를 위한 가용골 높이의 결정에 미치는 영향)

  • Jhin, Min-Ju
    • Journal of Periodontal and Implant Science
    • /
    • 제32권2호
    • /
    • pp.379-388
    • /
    • 2002
  • For the success of dental implant, accurate radiographic evaluation is prerequisite for planning the location of the osseointegrated implants and avoiding injury to vital structures. CT/MPR(computed tomography/multiplanar reformation) shows improved visualization of inferior alveolar canal. In order to obtain cross-sectional images parallel to the teeth, the occlusal plane is used to orientate for the axial plane. If the direction of axial plane is not parallel to the occlusal plane, the reformatted cross-sectional scans will be oblique to the planned fixture direction and will not show the actual dimension of the planned fixture's location. If the available bone height which measured in the cross-sectional view is much greater than the actual available bone height, penetration of canal may occur. The aim of this study is to assess the effect of the axial plane to measurement of available bone height for dental implant in computed tomography of the mandible. 40 patients who had made radiographic stents and had taken CT were selected. The sites that were included in the study were 45 molar regions. In the central panoramic scan, the length from alveolar crest to superior border of inferior alveolar canal(available bone height, ABH) was measured in direction of reformatted cross-sectional plane(uncorrected ABH). Then, length from alveolar crest to superior border of canal was measured in direction of stent(corrected ABH). The angle between uncorrected ABH and corrected ABH was measured. From each ABH, available fixture length was decided by $Br{{\aa}}nemark$ system. The results were following ; the difference between two ABHs was statistically significant in both first and second molar(p< 0.01). The percentage of difference more than 1 mm was 8.7% in first molar and 15.5% in second molar. The percentage of difference more than 2 mm was 2.0% in first molar and 6.6% in second molar. The maximum value of difference was 2.5 mm in first molar and 2.2 mm in second molar. The correlations between difference of 2 ABHs and angle was positive correlations in both first and second molar. The correlation coefficient was 0.534 in first molar and 0.728 in second molar. The second molar has a stronger positive correlation. The percentage of disagreement between 2 fixture lengths from two ABHs was 24.4% in first molar and 28.9% in second molar.

Analysis of Age-related Distribution of the Tracheal Diameter and Cross-sectional Area Among Koreans -Compuerized Tomographic Measurement- (한국인의 연령별 기관 내경 및 단면적 분포에 대한 분석 -흉부전산화단층촬영을 이용한 측정-)

  • Lee, Gun;Kim, Dae-Sik;Moon, Seung-Chul;Koo, Won-Mo;Yang, Jin-Young;Lee, Hyeon-Jae;Lim, Chang-Young;Han, Hyeon;Kim, Kwang-Ho;Sun, Kyung
    • Journal of Chest Surgery
    • /
    • 제32권5호
    • /
    • pp.442-447
    • /
    • 1999
  • Introduction: Understanding the normal distribution of the tracheal diameter and crross- sectional area is one of the key elements in the management of various tracheal pathologies or tracheal reconstruction for the patients in growing age. However, data for Korean standard has been lacking. This study was designed to analyze retrospectively the distribution of tracheal diameter and cross-sectional area in young Koreans, which can afford fundamental data for the management of tracheal diseases. Material and Method: Of the patients who underwent computerized tomogram of the chest between May 1996 and August 1998, one hundred six young patients(age range: 0-20 years) were included. Patients with any conditions which might affect the tracheal cross-sectional area or diameter, such as tracheal disease, previous operation, mediastinal tumor, or obstructive lung disease were excluded from the study. Gender distribution was 69 males and 37 females. Tracheal diameters, anterior-posterior and transverse, were measured at the level of the thoracic inlet(level I) and the aortic arch(level II). Types of the trachea were divided into round, oval, or horseshoe shaped on cross-sectional view, and the dimension was calculated by using the equation of A=1/4$\pi$ab(A; area, $\pi$; 3.14, a; anterior-posterior diameter, b; transverse diameter). We analyzed the distribution of the diameter at each level and compared the cross-sectional area with respect to age and gender. A p-value lower than 0.05 wa considered significant. Result: The trachea of patients less than 5 years old were round in shape at both of level I and II, and no differences in cross-sectional area was observed between the levels(p=NS). As the age increased, the trachea become oval in shape at level I while it remained round in shape at level II(p=0.020). The tracheal diameter and cross-sectional area increased as the age increased with a linear correlation(r>0.9). In patients less than 5 years of age, female patients showed larger cross-sectional area than male patients (p=0.020), and it was reversed in patients older than 15 years of age(p=0.002). Conclusion: From the above results, we suggest chest computerized tomogram as a safe and reliable tool in measuring the tracheal diameter and cross-sectional area. We also provide the data as a standard for distribution of the tracheal diameter and cross-sectional area in young Korean population.

  • PDF

Rotational Accuracy Measurement of Scroll Compressor with D-type Sectional Shaft

  • Park, Sang-Shin;Kim, Gyu-Ha;Lee, Jin-Kab
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.125-127
    • /
    • 2002
  • This paper presents the measurement process of the rotational accuracy and the comparison with the theoretical results in the main bearing of scroll compressor. The main bearing is cylindrical oil proceeding bearing, but there are straightly cut used for oil supply. Therefore the roundness error is not a negligible quantity compared with the rotational accuracy. For this reason, three-point method is used in the experiment. The result of three-point method coincides with the theoretical value. So if the theory in this paper is used to the bearing design of scroll compressor, the efforts for testing and designing can be reduced.

  • PDF

The thermal effect on electrical capacitance sensor for two-phase flow monitoring

  • Altabey, Wael A.
    • Structural Monitoring and Maintenance
    • /
    • 제3권4호
    • /
    • pp.335-347
    • /
    • 2016
  • One of major errors in flow rate measurement for two-phase flow using an Electrical Capacitance Sensor (ECS) concerns sensor sensitivity under temperature raise. The thermal effect on electrical capacitance sensor (ECS) system for air-water two-phase flow monitoring include sensor sensitivity, capacitance measurements, capacitance change and node potential distribution is reported in this paper. The rules of 12-electrode sensor parameters such as capacitance, capacitance change, and change rate of capacitance and sensitivity map the basis of Air-water two-phase flow permittivity distribution and temperature raise are discussed by ANSYS and MATLAB, which are combined to simulate sensor characteristic. The cross-sectional void fraction as a function of temperature is determined from the scripting capabilities in ANSYS simulation. The results show that the temperature raise had a detrimental effect on the electrodes sensitivity and sensitive domain of electrodes. The FE results are in excellent agreement with an experimental result available in the literature, thus validating the accuracy and reliability of the proposed flow rate measurement system.

Measurement of Vibration Using a 3-facet Mirror

  • Park, Won-Shik;Cho, Hyung-Suck;Byun, Yong-Kyu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.131.5-131
    • /
    • 2001
  • A new measurement method to measure vibrational motions of objects is presented. The original principle is similar to the previous work that utilized a 3-facet mirror to obtain three dimensional positions and orientations of rigid bodies. While the previous work was presented for only stationary objects, in this paper, we newly investigate the feasibility of this method for dynamic applications. The 3-facet mirror that looks like a triangular pyramid having an equilateral cross-sectional shape. The mirror has three lateral reflective surfaces inclined 45 degrees to its bottom surface, and its mounted on the object whose motion is to be measured, As optical components, a He-Ne laser source and three position-sensitive detectors(PSD) are used. The laser beam is emitted from the He-Ne laser source located at the upright position and vertically incident to the top of the 3-facet ...

  • PDF

Development of longitudinal acceleration wave decomposition method with single point measurement (단일 위치에서의 측정을 이용한 가속도 종파 분리 방법의 개발)

  • Jung, B.;Park, Y.;Park, Youn-Sik
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.629-633
    • /
    • 2006
  • We investigated a new longitudinal acceleration wave decomposition method in time domain. The proposed method separates up- and down-stream waves with an axial strain and axial acceleration measured at a single point on the transmission path. The advantages such as low computation load and easy implementation would be possible by developing time domain under the following assumptions; low frequency range, uniform cross sectional area and elastic wave propagation. We confirmed the feasibility and performance of the method through experiment using Split Hopkinson Pressure Bar (SHPB). The method can be effective in several applications, including active vibration control with wave view point, where real time wave decomposition is necessary.

  • PDF