• Title/Summary/Keyword: Secondary Zone

Search Result 297, Processing Time 0.018 seconds

Individual-based Competition Analysis for Secondary Forest in Northeast China

  • Li, Fengri;Chen, Dongsheng;Lu, Jun
    • Journal of Korean Society of Forest Science
    • /
    • v.97 no.5
    • /
    • pp.501-507
    • /
    • 2008
  • The data of crown width with 4 directions, DBH, tree height, and coordinate for sample trees were collected from 30 permanent sample plots in secondary fore st of the Maoershan Experimental Forestry Farm, Northeast China. In this paper, the competition of individual trees in stand were discussed for secondary forest by using iterative Hegyi competition index and crown overlap index that represented the competitive and cooperative interactions among neighboring trees. Active competitors of subject tree in the competition zone were selected to calculate the iterative competition index. Using the results of crown classification based on the equal crown projection area, a new distance dependent competition index called crown overlap index (COI) was developed for secondary forest. The COI performed well in describing the crown competition rather than crown competition factor (CCF). The individual-based competition index discussed in this paper will provide more precise for developing individual tree growth models for secondary forest and it can also use to adjust the stand structure for spatial optimal management.

Physio-chemical and Mineralogical Characterization of the Tailings in the Guryoung Mining Area (구룡광산 광미층의 심도변화에 따른 물리.화학적 및 광물학적 특성)

  • Moon, Yong-Hee;Kim, Jeong-Yeon;Song, Yun-Goo;Moon, Hi-Soo
    • Economic and Environmental Geology
    • /
    • v.41 no.2
    • /
    • pp.183-199
    • /
    • 2008
  • This study is focused on characterization of the physio-chemical and mineralogical properties, investigation of their vertical changes in the tailing profile of the Guryoung mining area, classification of the profile into distinct zones, and condition conceptual model of physio-chemical conditions and phases-water relationships controlling the element behaviors in the tailings. The upper part of the groundwater is characterized by the high contents of $Fe_2O_3$ and $SO_3$ for whole rock analysis, low pH, and the occurrence of jarosite, schwertmannite and Fe-oxyhydroxide as the secondary mineral phases. The tailing profile can be divided into the covering soil, jarosite zone, Fe-sulfate zone, Fe-oxyhydroxide and gypsum-bearing pyrite zone, calcite-bearing pyrite zone, soil zone, and weathered zone on the based of the geochemical and mineralogical characteristics. The profile can be sampled into the oxidized zone and the carbonate-rich primary zone with the dramatic changes in pH and the secondary mineral phases. The conceptual model proposed for the tailing profile can be summarized that the oxidation of pyrite is the most important reaction controlling the changes in pH, the dissolution of the primary silicates and carbonates, the precipitation of secondary mineral phases, acid-neutralizing, and heavy metal behaviors through the profile.

Stability of premixed double concentric jets flame with a recirculation zone (재순환역을 수반하는 동축분류예혼합화염에 관한 연구)

  • 이등헌일;송규근
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.1
    • /
    • pp.145-153
    • /
    • 1987
  • Stability limits of a double concentric jets flame and the structure of recirculation zone formed behind a thick burner rim were investigated. To control the flame stability, swirled secondary air flow ranging 0.13-0.71 of swirl number, and air, fuel, and mixture gas injection from an injection coaxial slit set on burner rim were examined. Flame stability limits, flame shapes, lengths of recirculation zone, temperature distributions, residence times, air ratios in the recirculation zone were measured. The following results were obtained. (1) Lean limits were considerably widened by a strong swirl because the recirculation zone was enlarged. (2) At fuel injection as well as mixture injection, lean limits were also extended. But, air injection had no effect on stability limits. (3) Injected gas seems to diffuse into the recirculation zone through its outer boundary surrounded the secondary air. Therefore, chemical structure in the recirculation zone with air injection coincides with that without injection. (4) Injection position had no effect on flame stability limits.

A Study on the Space Zoning and Area Composition of the Operation Department in Regional Public Hospitals - Focused on Net Floor Area (지방의료원 수술부 영역 및 면적 구성에 관한 조사·분석연구 - 순면적을 중심으로)

  • Yun, Woo Yong;Chai, Choul Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.25 no.3
    • /
    • pp.25-36
    • /
    • 2019
  • Purpose: To establish guidelines for local public hospitals, the survey was conducted primarily on the current status of local public hospitals, focusing on the zone configuration and the spatial area of the operating department. Methods: 3 Methods have been used in this paper. 1) Analyzing drawings to derive the net floor area of each room. 2) A literature survey about composition of the zone by infection control. 3) Observation survey for user circulation analysis. Results: The operation department consists of the major, secondary, support and connected zones according to the user's actions. The spatial area composition ratio for each zone is major zone: 41.79%, secondary zone: 10.87%, support zone: 23.10%, and connected zone: 24.24%. Implications: This study is a basic research for guideline for the operation department in local public hospitals. In this study, zones configuration of the operation departments are classified in terms of user actions and room functions. In the future, it is required to establish criteria considering infection control and copper connection aspects.

Analysis of LPG Facility Siting Considering BLEVE (BLEVE를 고려한 LPG 시설 Siting 분석)

  • Kim, Taebeom;Lee, Kyounglim;Lee, Juhee;Jung, Seungho;Lee, Kunmo
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.2
    • /
    • pp.26-32
    • /
    • 2016
  • In previous studies on LPG siting in Korea, the scope have not included the probability of the secondary events of adjacent LPG tanks or structures from an explosion source. Therefore, it is essential to first identify the phenomenon which can be caused by BLEVE and then, properly assess their effects to each target including secondary event. In this study, we calculated the effects from a potential BLEVE of 15 ton LPG tank causing damages of storage tanks (LPG), structures and human using Phast ver. 6.7 and then suggested three risk zones (Zone I, II, III) assuming the consequences such as overpressure, heat radiation and missile effect by fragments. Zone I and II are divided at the line of 50% occurrence of the secondary event. Zone II and III are divided by Individual Risk(IR). The zone approach in this study can be used for more effective and safer Land Use Planning (LUP) for the future.

Floating-Zone Growth of Single Crystal Olivine $[(Mg_{1-x}Fe}_{x})_2SiO_4]$ (Floating Zone법에 의한 올리빈 $[(Mg_{1-x}Fe}_{x})_2SiO_4]$단결정 성장)

  • 정광철;강승민;신재혁;한종원;최종건;오근호;박한수;문종수
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.3 no.1
    • /
    • pp.85-92
    • /
    • 1993
  • Large single crystals of olivine were grown by using image furnace(floating zone furnace)under controlled partial pressure of oxygen. The transparent crystals have maximum sizes 65mm in length by 7mm in diameter. When partial pressure of oxygen was decreased, the portion of secondary phases in crystals were increased so that it made crystals dark brown. The secondary phases were proved to be solid solution of Mg, Si, and Fe by electron microprobe analysis. Mg was major portion and the rest was minor.

  • PDF

Combustion and Emission Characteristics of Model Gas Turbine Combustor (모형 가스터빈 연소기의 연소 및 배출물 특성)

  • 최병륜;김태한
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.1
    • /
    • pp.240-249
    • /
    • 1994
  • The basic experiments for designing the effective gas turbine combustor were performed. There are several factors that define the characteristics of gas turbine combustor. Among them, experiment was focused on swirl effects by three types of swirler with different swirl numbers(0.0, 0.38, and 0.62). Particularly, an interest was concentrated on primary zone where the flame characteristics of total combustor was dominated strongly and secondary zone where the remaining unburned gas was reacted again or cooling effect was done according to degree of swirl intensity. For this study, following measurements have been carried out, that is, time mean and fluctuating temperature, exhaust gas composition including NO concentration, and ion current. From this study, it was found that swirl intensity affects largely not only flame style but also emission formation, furthermore that it is important to select proper swirl intensity.

Numerical Analysis for the Performance Prediction of Combustion Chamber of Commercial Incinerator (상업용 소각로 연소실 성능예측을 위한 수치해석 연구)

  • Lee, Jin-Wook;Park, Byung-Soo;Yun, Yong-Seung;Seo, Jung-Dae;Huh, Il-Sang
    • Journal of the Korean Society of Combustion
    • /
    • v.4 no.1
    • /
    • pp.141-153
    • /
    • 1999
  • Numerical analysis for the combustion flow in the combustion chamber of incineration system has been carried out in order to acquire the basic design capability of incineration system. Established mathematical model was applied to the performance prediction of the pre-designed combustion chamber of commercial plant. Especially, combustion characteristics and the variation of flow pattern have been deeply discussed in accordance with secondary air injection. Secondary air injection was effective for the turbulent mixing between air and carbon monoxide/volatile matter resulting in considerably reduced CO content at the exit. Secondary air injection was found to be one of the key design parameters because the size of recirculation zone could be changed with the variation of injection characteristics.

  • PDF

Flow Analysis in an Entrained Flow Combustor (분류층 연소기내의 유동해석)

  • 양희천;박상규;정동화
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.25 no.6
    • /
    • pp.1308-1316
    • /
    • 2001
  • This paper described a numerical investigation performed to understand better the effects of flow parameters in an entrained flow combustor on the flow characteristics. The computational model was based on the gas phase Eulerian equations of mass, momentum and energy. The code was formulated with RNG $k-\varepsilon$ model for turbulent flow. The calculation parameters were the ratio of primary and secondary jet velocity and the height difference between primary and secondary jet As the secondary jet velocity increased, the upper recirculation 3one of the primary jet was strengthened. It was found that as the primary jet velocity increased, there was a critical jet Velocity at which the size of upper and lower recirculation zone was reversed.

  • PDF

Visualization of the Supersonic Swirl Jet with Annular Stream (환형 유동을 수반하는 초음속 스월 제트 유동의 가시화)

  • Kim Jung-Bae;Lee Kwon-Hee;Setoguchi Toshiaki;Kim Heuy-Dong
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.91-94
    • /
    • 2003
  • The present study addresses experimental results to investigate the details of the near field flow structures produced in the under-expanded, dual, coaxial, swirling, jet. The sonic swilling jets are emitted from a sonic inner nozzle and the outer annular nozzle produces the co/counter swirling streams against the primary swirling jet, respectively. The interactions between both the secondary annular swirling and primary inner supersonic swirling jets are quantified by the pilot impact and static pressure measurements, and visualized by using the Schlieren optical method. The experiment has been performed fur different swirl intensities and pressure ratios. The results obtained show that the secondary co-swirling jet significantly changes the inner under-expanded swirling jet, such as the recirculation zone, pressure distribution, through strong interactions between both the swirling jets, and the effect of the secondary counter-swirling jet on the primary inner jet is similar to the secondary co-swirl jet case.

  • PDF