Stability of premixed double concentric jets flame with a recirculation zone

재순환역을 수반하는 동축분류예혼합화염에 관한 연구

  • Published : 1987.01.01

Abstract

Stability limits of a double concentric jets flame and the structure of recirculation zone formed behind a thick burner rim were investigated. To control the flame stability, swirled secondary air flow ranging 0.13-0.71 of swirl number, and air, fuel, and mixture gas injection from an injection coaxial slit set on burner rim were examined. Flame stability limits, flame shapes, lengths of recirculation zone, temperature distributions, residence times, air ratios in the recirculation zone were measured. The following results were obtained. (1) Lean limits were considerably widened by a strong swirl because the recirculation zone was enlarged. (2) At fuel injection as well as mixture injection, lean limits were also extended. But, air injection had no effect on stability limits. (3) Injected gas seems to diffuse into the recirculation zone through its outer boundary surrounded the secondary air. Therefore, chemical structure in the recirculation zone with air injection coincides with that without injection. (4) Injection position had no effect on flame stability limits.

본 논문에서는 예혼합동축분류화염에 있어서 재순환역 안으로의 기체(공기, 연료, 혼합기) 주입과 2차공기의 족회가 화염안정성, 화염형상 및 재순환역에 미치는 영향을 명확히 하였다.

Keywords