• Title/Summary/Keyword: Swirl

Search Result 1,156, Processing Time 0.029 seconds

The Effect of Swirl on the Structure of Concentric Laminar Jet Diffusion Flame (동축분류 층류제트 확산화염의 구조에 미치는 선회의 영향)

  • 김호영;민성기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.3
    • /
    • pp.578-588
    • /
    • 1992
  • In order to predict the effect of swirl on the structure of concentric laminar jet diffusion flame, present study examined the effect of swirl on the flame characteristics by numerical numerical analysis through theoretical model. The theoretical model has been developed for the co-axial laminar jet flame such that the fuel and air are supplying with swirl through inner and outer co-axial tube respectively. For the parametric study, swirl number, Reynolds number of fuel and air and directions of swirl are chosen as important parametes. The results of study show that the flame with width and shorter length is formed by larger swirl number. The important factor of the flame shape is the recirculating zone formed around jet axis near the exit of nozzle. In case of weak swirl, the effect of directions of swirl is not appeared. However, for the strong swirl, the flame with shorter length are appeared in case of counter-swirl compared with the case of co-swirl.

Rotordynamic Analysis of Labyrinth Seal with Swirl Brake (스월 브레이크가 장착된 래버린스 씰의 동특성 해석)

  • Lee, Jeongin;Suh, Junho
    • Tribology and Lubricants
    • /
    • v.38 no.2
    • /
    • pp.63-69
    • /
    • 2022
  • In this research, the rotordynamic characteristics of the labyrinth seal with and without swirl brake were predicted using the computational fluid dynamic (CFD) model. Based on previous studies, a simple swirl brake consisting of square vanes without stagger angle is designed and placed in front of the seal inlet. The rotating frame of reference is utilized to consider the whirling motion of the rotor in the steady-state analysis since the whirling motion is transient behavior in nature. CFD analysis was performed in the range of -1 to 1 pre-swirl ratio for a given seal and swirl brake design and operating conditions. The CFD analysis result shows that the swirl brake effectively reduces the pre-swirl since the circumferential fluid velocity of labyrinth seal with swirl brake was lower than that without swirl brake. The cross-coupled stiffness coefficient, which is greatly affected by the circumferential fluid velocity, increased with an increasing pre-swirl ratio in a seal without a swirl brake but showed a low value in a seal with a swirl brake. The change in the damping coefficient was relatively small. The effective damping coefficient of the labyrinth seal with swirl brake was generally constant and showed a higher value than the labyrinth seal without swirl brake.

Performance Estimation of Small Regenerative Radiant Tube Burner System using High Velocity Discharge (고속분사를 이용한 소형 축열식 복사관 버너시스템의 성능평가)

  • Cho, Han-Chang;Cho, Kil-Won;Lee, Yong-Kuk
    • 한국연소학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.242-247
    • /
    • 2004
  • An Experimental study was conducted on spray combustion using dual swirlers at different outlet angle; co-swirl and counter-swirl. To understand the characteristics of turbulent spray combustion of dual swirl flow (DSF), the axial helical annular vaned swirlers with various swirl ratios and combination of angle and direction were designed. and temperature measurements of a rapidly thermocouple insertion and measurements of soot volume fraction and microrstructure using thermophoretic sampling particle diagnostic (TSPD) as TEM were carried out. The NOx, $CO_2$, $O_2$, etc. was analyzed using emission gas analyzer. The results show that flame stability were maintained under very lean condition. for both co-swirl and counter-swirl case. And though Counter-swirl case kept the higher temperature region compared to co-swirl case, Counter-swirl combustion represented less NOx emission and soot formation than co-swirl case.

  • PDF

An Experimental Study on the Flow Characteristics of a Swirl-Jet Diffuser (공장환기용 선회 제트 디퓨저의 유동 특성에 관한 실험 연구)

  • Lee, C.S.;Jurng, J.;Jeong, S.Y.;Hong, K.H.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.2
    • /
    • pp.103-109
    • /
    • 1994
  • An experimental study is performed on the flow characteristics of a swirl-jet diffuser for factory ventilation. Swirl number ranges from 0(nonswirl jet) to 0.6 when the angle of swirl vane is 60 degree. As swirl becomes strong, the maximum velocity in the plane perpendicular to jet axis decreases fast and the uniformity of velocity becomes good, particularly in the ventilated area. The similarity in velocity profiles has been found for axial velocity from even when swirl number equals 0.6. The flow characteristics of the swirl-jet which has the swirl number of 0.6 is thought to be the best among these three swirl numbers for factory ventilation. However, the pressure drop in the diffuser increases as the swirl becomes strong. This should be considered in the design of the total ventilation system including a duct system.

  • PDF

A Study on Combustion Characteristics of Turbulent Spray Flame by the Dual Swirler (2중스월류에 의한 난류분무화염의 연소특성 연구)

  • Lee, Kang-Yeop;Hwang, Sang-Soon
    • 한국연소학회:학술대회논문집
    • /
    • 2000.05a
    • /
    • pp.105-116
    • /
    • 2000
  • An Experimental study was conducted on spray combustion using dual swirlers at different outlet angle; co-swirl and counter-swirl. To understand the characteristics of turbulent spray combustion of dual swril flow(DSF), the axial helical annular vaned swirlers with various swirl ratios and combination of angle and direction were designed. and temperature measurements of a rapidly thermocouple insertion and measurements of soot volume fraction and microrstructure using thermophoretic sampling particle diagnostic(TSPD) as TEM were carried out. The NOx, $CO_2$,$O_2$, etc. was analyzed using emission gas analyzer. The results show that flame stability were maintained under very lean condition. for both co-swirl and counter-swirl case. And though Counter-swirl case kept the higher temperature region compared to co-swirl case, Counter-swirl combustion represented less NOx emission and soot formation than co-swirl case.

  • PDF

A Study on Combustion Characteristics of Turbulent Spray Flame by the Dual Swirler (2중스월류에 의한 난류분무화염의 연소특성 연구)

  • Lee, Kang-Yeop;Hwang, Sang-Soon
    • Journal of the Korean Society of Combustion
    • /
    • v.5 no.1
    • /
    • pp.67-79
    • /
    • 2000
  • An Experimental study was conducted on spray combustion using dual swirlers at different outlet angle; co-swirl and counter-swirl. To understand the characteristics of turbulent spray combustion of dual swril flow(DSF), the axial helical annular vaned swirlers with various swirl ratios and combination of angle and direction were designed. and temperature measurements of a rapidly thermocouple insertion and measurements of soot volume fraction and microstructure using thermophoretic sampling particle diagnostic(TSPD) as TEM were carried out. The NOx, $CO_2,\;O_2$, etc. was analyzed using emission gas analyzer. The results show that flame stability were maintained under very lean condition. for both co-swirl and counter-swirl case. And though Counter-swirl case kept the higher temperature region compared to co-swirl case, Counter-swirl combustion represented less NOx emission and soot formation than co-swirl case.

  • PDF

Interaction Between Partially Premixed and Premixed Swirl Flames in a Hybrid/Dual Swirl Jet Combustor (하이브리드/이중 선회제트 연소기에서 부분예혼합-예혼합 선회화염의 상호작용)

  • Jo, Joonik;Hwang, Cheol-Hong;Lee, Kee-Man
    • 한국연소학회:학술대회논문집
    • /
    • 2012.04a
    • /
    • pp.7-8
    • /
    • 2012
  • The effects of interaction between partially premixed and premixed swirl flames on CO and NOx emissions were experimentally investigated using a hybrid/dual swirl jet combustor for a micro-gas turbine. Under the condition of constant angle ($45^{\circ}$) for outer swirl vane, the angle and direction of inner swirl vane installed for a partially premixed flame were varied as main parameters with a constant fuel flow rate for each nozzle. It was found that for all conditions, CO and NOx emissions were measured below 4 ppm and 15 ppm at 15% $O_2$, respectively, in a wide range of equivalence ratio (0.6~0.9). For co-swirl flows, CO emission increased dramatically as the angle of inner swirl vane increased from $15^{\circ}$ to $45^{\circ}$ near lean-flammability limit (i.e. equivalence ratio of 0.5). On the other hand, the case of swirl $angle=45^{\circ}$ provided the lowest NOx emission at higher equivalence ratios than 0.6. For counter-swirl flows, the case of swirl $angle=45^{\circ}$ extended the lean-flammability limit but higher NOx emissions were found compared to those of co-swirl flows. These results could be inferred by interaction between (inner) partially premixed and (outer) premixed swirl flames. However, these estimations were not clear yet because there was insufficient data on turbulent flow structure and fuel-air mixing in the present experimental approach.

  • PDF

Influence of Fuel Swirl Flow on NOx Emission in Swirl Combustor (스월연소기에서 연료스월유동이 NOx 배출에 미치는 영향)

  • Cho, Jin-Woo;Whang, Sang-Ho;Choi, Gyung-Min;Kim, Duck-Jool
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.7
    • /
    • pp.70-75
    • /
    • 2005
  • In this study, experimental investigations were conducted on NOx emission characteristics with fuel swirl flow in swirl combustor. Many types of vanes, which altered air and fuel swirl angles, were employed to verify the mixing processes. For strong air swirl, fuel counter-swirl resulted in relatively large turbulent intensity, high energy to the high frequency region and narrow width of high temperature region compared with co-swirl condition. These effects of fuel counter-swirl resulted in low NOx emission characteristics at strong air swirl condition. And NOx reduction mechanism was also discussed.

Effect of Swirl Angles in Low-Swirl Combustor (저선회 연소기의 선회각도에 따른 영향)

  • Jeong, Hwanghui;Choi, Inchan;Lee, Keeman
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.123-125
    • /
    • 2015
  • A study has been conducted to investigate the effect of swirl angle in low swirl combustor. In this study, the employed swirl angles were $28^{\circ}$, $32^{\circ}$ and $37^{\circ}$. Direct flame photos show that the width of the flame is expanded and the length of the flame is shortened when swirl angle is increased. Also, as the swirl angle was increased, the flame stability region could be widened due to the expansion of lower flammable limit. Between 3 and 7kW, CO emissions was below 10 ppm and NOx emissions was also below 27 ppm at $O_2$ 15% basis over the lean burning range of 0.6 < ${\Phi}$ < 0.9. From this investigation of stability expansion effect and emission performance, it was identified that the swirl angle $37^{\circ}$ is most suitable swirling condition in the low swirl model combustor.

  • PDF

NOx Formation and Emission Characteristics of Premixed Swirl Flame of Natural Gas (천연가스 선회 예혼합 화염의 NOx 생성 및 배출 특성)

  • You, Hyun-Seok;Lee, Joong-Seong;Han, Jeong-Ok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.6
    • /
    • pp.788-794
    • /
    • 1999
  • The swirl flame is mostly used to stabilize the flame on the burner nozzle in the industrial combustor. In the case of the weak swirl flame(S<0.4), the recirculation zone could not be formed, but in the strong swirl(S>0.6) flame, it could be formed in the center of the swirl flame. In this study, the measurement and analysis of emission species, temperature, radicals of premixed swirl flame in the combustor were performed to understand the NO formation and emission characteristics of the swirl flame of natural gas. The result of NO emission in the swirl flame is that the amount of NO emission in the strong swirl flame decreased about 60% compared with that of the weak swirl flame. The main region of NO formation of the weak swirl flame is positioned in the down stream(z=100~200mm) of the flame, but that of the strong swirl flame is positioned in the up stream(z=40mm) where the recirculation zone seems to be formed. It is supposed that the increase of flame surface and the formation of inversed flame cause the reduction of the high temperature region on the production of NO in the strong swirl flame. The result of NO-temperature relation revealed that the factor of NO formation is not only temperature but also another parameters in the weak swirl flame, but in the strong swirl flame, NO is proportional to the temperature of higher than 1200K.