• Title/Summary/Keyword: Secondary Source

Search Result 700, Processing Time 0.024 seconds

The Effects of Secondary Fuel Injection on Combustion Oscillation

  • Shigeru Tachibana;Laurent Zimmer;Park, Gyung-Min;Takeshi Yamamoto;Ufosawa, Yoji-K;Seiji Yoshida;Kazuo Suzuki
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.376-379
    • /
    • 2004
  • The purpose of this work is to develop an effective active control system for combustion instabilities of premixed combustors. For the first step, the natural modes of combustion oscillation were investigated for a methane-air premixed combustor and the controls by secondary fuel injection were examined. The main premixed flame is stabilized by a swirler with orifices for secondary injection installed on the central hub. For sensing purposes, a pressure transducer and a chemiluminescence sensor were placed on the appropriate positions. The acoustic characteristics and the source of the oscillation were analyzed by those signals. To test the controllability, two methods of actuations by secondary fuel injection were examined. One is the open loop control and the other is the closed loop control. The comparison of the reduction levels of p $_{rms}$ shows that the closed loop control with a phase-shift injection performs best in this condition.ition.n.

  • PDF

ARC Discharge Sound Source in Underwater (수중 아-크 방전음원에 관한 연구)

  • Chang, Jea-Hwan;Chang, Jee-Won
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.21 no.1
    • /
    • pp.12-18
    • /
    • 1985
  • In general the impulse sound sources of underwater generated by electric arc discharge had used static energy of the charged capacitors. The author proposed an underwater arc discharge sound source using secondary voltage of high voltage transformer without capacitors. The arc discharge device was composed of a high voltage transformer and a switching system. The impulse current in the primary turn of the high voltage transformer is controlled by the switching system and inductive current of the secondary turn in the high voltage transformer is used in making impulsive arc discharge. A series of experiment have been carried out to observe the acoustic characteristics of the impulse sound source generated by the arc discharge. The results obtained were as follows: 1. Secondary current at the time of arc discharge keeps after ohm's law in the beginning and the maximum current flows out as soon as arc discharge breaks out. 2. A time difference between a start of applied current and a generation of arc discharge sound is the 3msec and it is generated arc sound when breaking down electric insulation at maximum voltage. 3. The sharper the end of electrodes and the higher the secondary voltage, the higher the sound pressure level. 4. Arc discharge sound was generated even at the distance of 100cm between electrodes and was stably reproductive at the gap of 1cm to 100cm. 5. Electric arc discharge sound wave is a shock wave of pulse-width of 0.15msec and spectral distribution of it is plenty of low frequency components less than 10 KHz.

  • PDF

Source Apportionment of Fine Particulate Matter (PM2.5) in the Chungju City (충주시 초미세먼지 (PM2.5)의 배출원 기여도 추정에 관한 연구)

  • Kang, Byung-Wook;Lee, Hak Sung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.5
    • /
    • pp.437-448
    • /
    • 2015
  • The purpose of this study is to present the source contribution of the fine particles ($PM_{2.5}$) in Chungju area using the CMB (chemical mass balance) method throughout the four seasons in Korea. The Chungju's annual average level of $PM_{2.5}$ was $48.2{\mu}g/m^3$, which exceeded two times higher than standard air quality. Among these particles, the soluble ionic compounds represent 54.2% of fine particle mass. Additionally, the OC concentration in Chungju stayed similar to other domestic cities, while the EC concentration decreased significantly compared to other domestic/international cities. The concentration of sulfur represented the highest composition (8%) among the fine particle compounds. According to the CMB results, the general trend of the $PM_{2.5}$ mass contributors was the following: secondary aerosols (50.5%: ammonium sulfate 26.5% and ammonium nitrate 24.0%) > gasoline vehicle (18.3%) > biomass burning (11.0%) > industrial boiler (6.0%) > diesel vehicles (4.4%). The contribution of the secondary aerosols was the main cause than others. This impact is assumed to be emitted from air pollutants of urban cities or neighbor countries such as China.

PCBs and PBDEs in Pine Needles of Seoul and Ansung (서울, 안성지역 소나무 잎 중 PCBs와 PBDEs)

  • Lee, Sung-Hee;Yeo, Hyun-Gu
    • Journal of Environmental Science International
    • /
    • v.16 no.9
    • /
    • pp.1071-1076
    • /
    • 2007
  • Polychlorinated biphenyls(PCBs) and polybrominated diphenyl ethers (PBDEs) were measured in pine needles of Seoul, and Ansung(GyeongGi-do) to investigate composition, source, and regional concentration of PBDEs. Concentration of total PCBs in Seoul and Ansung showed 608, 945 pg/g DW (mean: 777 pg/g DW), respectively, also concentration of total PBDEs(pg/g DW) in Seoul and Ansung showed 7944, 14,255 pg/g DW(mean 11,100 pg/g DW). Tetrachlorinated biphenyls(Tetra-CBs) and Decabromodiphenyl ethers (Deca-BDE) were detected in relatively high concentration compared to other PBDE congeners in Seoul and Ansung. Correlation coefficients(r) of between PCB congeners in pine needles detected of Seoul and Ansung were significant (r=0.85, p<0.01). It suggested that PCBs concentration in pine needles may originate from secondary sources such as air-plant partition. The similarity of between PBDE congeners profile to those of the technical mixture formulation (Bromkal 70-5DE) suggests a source of this product in these sites.

MRFR - Multipath-based Routing Protocol with Fast-Recovery of Failures on MANETs

  • Ngo, Hoai Phong;Kim, Myung Kyun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.2
    • /
    • pp.271-287
    • /
    • 2013
  • We propose a new multipath-based reliable routing protocol on MANETs, Multipath-based Reliable routing protocol with Fast-Recovery of failures (MRFR). For reliable message transmission, MRFR tries to find the most reliable path between a source and a destination considering the end-to-end packet reception reliability of the routes. The established path consists of a primary path that is used to transmit messages, and the secondary paths that are used to recover the path when detecting failures on the primary path. After establishing the path, the source transmits messages through the primary path. If a node detects a link failure during message transmission, it can recover the path locally by switching from the primary to the secondary path. By allowing the intermediate nodes to locally recover the route failure, the proposed protocol can handle the dynamic topological change of the MANETs efficiently. The simulation result using the QualNet simulator shows that the MRFR protocol performs better than other protocols in terms of the end-to-end message delivery ratio and fault-tolerance capability.

Distribution between Air-Soil Concentration of Organochlorine Pesticides (유기염소계 살충제의 대기-토양간 분배)

  • Choi, Min-Kyu;Chun, Man-Young
    • Environmental Analysis Health and Toxicology
    • /
    • v.22 no.4
    • /
    • pp.299-304
    • /
    • 2007
  • This paper was studied to investigate the equilibrium state between organochlorine pesticides (OCPs) concentration of air and soil, and to know whether soil is a secondary pollution source of OCPs in air or not. The OCPs concentration of air ($C_{air}$) and soil ($C_{soil}$) is not related to molecular weight, vapor pressure ($P_L$) and octanol-air partition coefficient ($K_{oa}$). The slope of the regression line between soil-air partition coefficient ($K_{sa}$) and scavenging coefficient ($C_{soil}/C_{air}$) was 0.2952, which the OCPs concentration between air and soil did not reached to the equilibrium state. The soil/air fugacity quotients ($f_{soil}/f_{air}$) of p, p'-DDT/DDD/DDE and ${\beta}-HCH\;(0.30{\sim}0.67$), which is smaller than 1, means the deposit of OCPs from air to soil. However, $f_{soil}/f_{air}$ of heptachlor, heptachlor epoxide, ${\alpha}/{\gamma}-chlordane$, trans-nonachlor, endosulfan sulfate and ${\alpha}/{\gamma}-HCH\;(1.90{\sim}73.25)$, which is greater than 1, means that soil is secondary pollution source of OCPs in air.

Evaluation of the Annual Performance of the Direct Expansion Vertical Closed-Loop Ground Source Heat Pump (직접순환식 수직밀폐형 지열원 열펌프의 연간 운전성능 평가)

  • Kim, Min-Sung;Woo, Joung-Son;Baik, Young-Jin;Jang, Jea-Chul;Kim, Ji-Young;Ra, Ho-Sang
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.534-542
    • /
    • 2012
  • Vertical closed-loop ground source heat pump systems(GSHP) have been installed widely in Korea since it can extract moderate temperature level of geothermal heat in a small area. As a ground heat exchanger, a vertical closed-loop type with brine circulation is mostly preferred since it is simple and less harmful to ground environment. However, it requires a secondary heat exchange loop between the refrigerant in a heat pump and the brine. By adding a geothermal heat exchanger in the secondary heat exchange loop, circulation pumps should be attached and the temperature difference between refrigerant and ground is increased, which are important parts of performance degradation. In this paper, annual and seasonal performances of direct expansion(DX) geothermal heat pump were estimated mathematically as an alternative of classical indirect geothermal heat pump based on the annual performance evaluation. As a result, DX geothermal heat pump showed 43% higher annual performance than the classical U-tube geothermal heat pump.

  • PDF

Annual Performance Evaluation of Direct Expansion Vertical Closed-Loop Ground Source Heat Pump for Residential Application (주거용 직접순환식 수직밀폐형 지열원 열펌프의 연간 운전성능 평가)

  • Kim, Min-Sung;Baik, Young-Jin;Ra, Ho-Sang
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.3
    • /
    • pp.114-122
    • /
    • 2012
  • Vertical closed-loop ground source heat pump systems(GSHP) have been installed widely in Korea since it can extract moderate temperature level of geothermal heat in a small area. As a ground heat exchanger, a vertical closed -loop type with brine circulation is mostly preferred since it is simple and less harmful to ground environment. However, it requires a secondary heat exchange loop between the refrigerant in a heat pump and the brine. By adding a geothermal heat exchanger in the secondary heat exchange loop, circulation pumps should be attached and the temperature difference between refrigerant and ground is increased, which are important parts of performance degradation. In this paper, annual and seasonal performances of direct expansion(DX) geothermal heat pump were estimated mathematically as an alternative of classical indirect geothermal heat pump based on the annual performance evaluation. As results, DX geothermal heat pump showed 43% higher annual performance than the classical U-tube geothermal heat pump.

Nanosized Calcite in the Chinese Loess (중국 뢰스의 나노 방해석)

  • Jeong, Gi-Young
    • Journal of the Mineralogical Society of Korea
    • /
    • v.20 no.4
    • /
    • pp.255-260
    • /
    • 2007
  • The loess on the Chinese loess plateau is not only the accumulation of Asian dust but also the source materials of Hwangsa. The eolian carbonates of the loess were dissolved and reprecipitated to form secondary pedogenic carbonates by the post-depositional weathering during the interglacial time. Mineralogical analysis shows that the secondary calcites are composed mostly of a nanosized fibrous calcite with rather constant width ($30{\sim}50nm$) and highly variable length. The nano calcite is the major authigenic mineral, which occurs as the fine-grained matrix of the loess and paleosol. The nano calcite was recently reported in the Hwangsa, where it was originated from the source regions of Chinese loess plateau.

MRFR - Multipath-based Routing Protocol with Fast-Recovery of Failures on MANETs

  • Ngo, Hoai Phong;Kim, Myung Kyun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.12
    • /
    • pp.3081-3099
    • /
    • 2012
  • We propose a new multipath-based reliable routing protocol on MANETs, Multipath-based Reliable routing protocol with Fast-Recovery of failures (MRFR). For reliable message transmission, MRFR tries to find the most reliable path between a source and a destination considering the end-to-end packet reception reliability of the routes. The established path consists of a primary path that is used to transmit messages, and the secondary paths that are used to recover the path when detecting failures on the primary path. After establishing the path, the source transmits messages through the primary path. If a node detects a link failure during message transmission, it can recover the path locally by switching from the primary to the secondary path. By allowing the intermediate nodes to locally recover the route failure, the proposed protocol can handle the dynamic topological change of the MANETs efficiently. The simulation result using the QualNet simulator shows that the MRFR protocol performs better than other protocols in terms of the end-to-end message delivery ratio and fault-tolerance capability.