• Title/Summary/Keyword: Second cam design

Search Result 37, Processing Time 0.02 seconds

Development of CAD Software for Automatic Design of Disk-Typed Cams-Part I : Iterative Contact Method (디스크형 캠의 자동설계용 CAD S/W 개발-Part I :설계 및 해석 알고리즘 개발)

  • Son, Ju-Ri;Sin, Jung-Ho
    • 한국기계연구소 소보
    • /
    • s.19
    • /
    • pp.149-154
    • /
    • 1989
  • Generally Cam-Follower systems consist of two elements: Cam is for rotating motion and follower for reciprocating motion. Depending on the shape of cam and type of follower, the motion of cam-follower system is determined. Thus design process and analysis process must be well defined. The design process means to find the coordinates of cam shape which can be defined the given motion of follower and the analysis process means to determine the motion curve of follower corresponding to the given cam based on the dimensions of a cam-follower system. This paper consists of two parts: One is development of a numerical method for design and analysis of cam-follower systems, the other is for development of a CAD program and its application. As the first part of the paper, an iterative contact method is proposed. This method can calculate the contact points between cam and roller and determine their contact angles iteratively. The second part of the paper presents the structure of a CAD program and its availability to the industrial applications.

  • PDF

Kinematic Analysis of a Continuously Variable Valve Actuation Mechanism with Movable Second Cam Center (2차 캠 중심 이동형 연속가변밸브 구동기구의 기구학 해석)

  • Kim, Do-Joong;Kim, Yong-Hyun
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.5
    • /
    • pp.7-15
    • /
    • 2009
  • This paper introduces a new variable valve actuation mechanism with movable second cam center. Valve lift and open duration can be continuously varied according to engine speed and load conditions. A new method to analyze the kinematic relations between the first and second cam profiles and valve motion are also introduced. Because of rocker motion of the second cam, conventional motion conversion program could not be used in this problem. An example shows continuous variations of valve motion and adequate ramp incorporation throughout all valve lift modes. Valve acceleration profile at the high lift mode is similar to that of conventional valvetrains. Contact geometry analysis of the mechanism gives basic information on the load conditions between the components.

Development of CAD Software for Automatic Design of Disk-Typed Cams-Part II : Computer-aided Analysis and Design Software (디스크형 캠의 자동설계용 CAD S/W 개발-Part II :CAD S/W 개발)

  • Son, Ju-Ri;Sin, Jung-Ho
    • 한국기계연구소 소보
    • /
    • s.19
    • /
    • pp.155-161
    • /
    • 1989
  • Generally cam-follower systems consist of two elements: Cam is for rotating motion and follower for reciprocating motion. Depending on the shape of cam and type of follower, the motion of cam-follower system is determined. Thus design process and analysis process must be well defined. The design process means to find the coordinates of cam shape which can be defined the given motion of follower and the analysis process means to determine the motion curve of follower corresponding to the given cam based on the dimensions of a cam-follower system. This paper consists of two parts : One is for development of a numerical method for design and analysis of cam-follower systems, the other is for development of a CAD program and its application. As the second part of the paper, the structure of a CAD program is introduced. Four data files are used in the program where the design process and the analysis process are carried out interactively to en hence its availability to the industrial applications. The first part of the paper 'presents the iterative contact method which can determine the contact points and their angles between cam and roller.

  • PDF

A Survey of Medical Students' Opinions about Complementary and Alternative Medicine

  • Song, Hywan
    • Korean Journal of Health Education and Promotion
    • /
    • v.20 no.4
    • /
    • pp.27-40
    • /
    • 2003
  • Objective: To determine second, third and fourth-year medical students' opinions and knowledge related to complementary and alternative medicine (CAM) in a school with no requirement or elective course on the subject. Study Design: A questionnaire was offered to second, third and fourth-year medical students of the Medical College of Kosin University from August 7th, through August 30th, 2003. Results: Most students had been exposed to CAM therapies, knew that the majority of the South Korean public was using CAM, believed that some CAM interventions were useful, and did not believe CAM therapies were a threat to public health. Only one fifth of the students(22.5%) disagreed that they had to have requirement or elective course on CAM in their curriculum. Most students had insufficient knowledge or understanding of the safety or lack of it for ten of the more common CAM modalities. Most respondents thought these interventions were useful, but would not refer a patient nor dissuade a patient from seeking out such interventions. Conclusion: Medical students in this school self-identified an interest about the clinical usefulness of ten CAM modalities, but did not have sufficient knowledge about the safety for ten of the more common CAM modalities. Including CAM topics in the medical school curriculum would better prepare physicians to respond to patient inquiries about CAM and thereby to fulfill their role as patient advocates.

A study on jewelry-making using a multi-casting (다중주물을 활용한 주얼리 제작에 관한 연구)

  • Lee, Jung Soo;Kim, Hyeong Seong
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.22 no.5
    • /
    • pp.223-226
    • /
    • 2012
  • There are many restrictions in conventional ways of Jewelry mass production which are Mokume Gane, Inlaid Technology based on a joining work of dissimilar metals. To overcome this, Multi-Casting using both Jewelry-Casting and CAD/CAM has presented. In experiment on Muti-Casting, second original sample which was produced by CAD/CAM is 5 % smaller than first one. The first and second castings are brass and silver, respectively. When making second sample, the temperature of flask was about $150{\sim}200^{\circ}C$ higher than the standard temperature of flask when making castings. Through the Multi-Casting, it was found that there was no trouble making dissimilar metals Jewelry which can be mass produced.

Graphics-Oriented CAD Developmen of Kinematic Analysis And Simwlation of An Automatic Feeding System By A Curvilinear Cam. Part II : Graphics-Oriented CAD Development (곡선 캠을 이용한 자동 이송장치의 기구 해석 및 Simulation용 Graphic-Oriented CAD 개발 2)

  • 신중호;류갑상;김상진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.269-272
    • /
    • 1987
  • This paper is concerned on kinematic analysis and simulation of an automatic feeding mechanism subjected by the motion of a curvilinear inverse cam. The main objection is the development of computer-aided design (CAD) program for simulating the motion of the cam-feeding mechanism using computer-graphics. A computer program CACAFS (Computer-Aided Cam and Automatic Feeding System) is independent of computer hardware used. The program is also interactive using a menu-selection technique. As the second part of the paper for the motion simulation of the cam-feeding system, this paper discusses the state-of-art for CAD. The first part of the paper presents the algorithm to simulate the notion of the cam-feeding mechanism.

  • PDF

Fabrication of computer-aided design/computer-aided manufacturing complete denture and conventional complete denture: case report (CAD/CAM system과 전통적인 방법을 이용한 총의치 동시 제작 증례)

  • Kim, Mi-Jin;Kim, Kang-Ho;Yeo, Dong-Heon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.32 no.2
    • /
    • pp.141-148
    • /
    • 2016
  • Recently computer-aided technology has been widely used in dentistry. DENTCA$^{TM}$ CAD/CAM denture system (DENTCA Inc.), one of CAD/CAM systems for fabricating complete denture, tries to collect and store all of a patient's information at the first visit. This system aims to deliver denture at the second visit through utilizing the CAD/CAM software to access the stored data for designing the 3D denture model. The 3 dimensional (3D) denture will then be fabricated with 3D printer. Many case reports have evaluated clinical application of CAD/CAM system for fabricating complete dentures. This case report is about fabricating of complete dentures using DENTCA system and conventional method in same patient. With two cases, usefulness and limitation of DENTCA system could be evaluated.

The treatment of an edentulous patient with conventional complete denture and CAD/CAM complete denture (Conventional한 방식과 CAD/CAM System을 이용한 완전 무치악 환자 동시 수복 증례)

  • Cho, Sungyoon;Lee, Joonseok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.1
    • /
    • pp.42-49
    • /
    • 2020
  • In patients with fully edentulous jaw, treatment of complete dentures should be carried out in many stages when following the conventional methods. Therefore there were disadvantages such as multiple visits to dental clinic is inevitable. In addition, errors caused by polymerization shrinkage, which happens during the fabrication of denture, and difficulties in reproduction of damaged or lost denture were considered as disadvantages. But nowadays, computer-aided design and computer-aided manufacturing (CAD/CAM) system is widely used in dentistry and it has begun to expand its spectrum in manufacturing complete dentures. Using CAD/CAM system to fabricate complete dentures can reduce the number of patient's visit and clinical chair time, since taking impression, recording jaw relation, and selection of artificial teeth are performed at the same time during the first visit, and delivering of dentures during the second visit is possible. In addition, because 3D-Printing technology is used, errors by polymerization shrinkage can be reduced. Among the companies that fabricate complete dentures using CAD/CAM system, DENTCA CAD/CAM denture (DENTCA Inc., Los Angeles, CA, USA) is the most commercialized company. In this case, we treated patients of complete dentures using conventional complete denture method and DENTCA CAD/CAM denture system in the same patient. We would like to report this case because we have achieved good results not only in functional aspects of pronunciation, chewing, and swallowing but also in aesthetic aspects.

A New Approach to CAD/CAM Systems Data Exchange Using Plug-in Technology

  • Chernopyatov Y.A.;Chung W.j.;Lee C.M.
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.6 no.4
    • /
    • pp.8-13
    • /
    • 2005
  • Interoperability has been the problem of CAD/CAM systems. Starting from 1980's, national and international organizations have addressed the issue through development and release of standards for the exchange of geometric and nongeometric design data. To CAD/CAM vendors, the task of interpreting and implementing these standards falls into their products. This task is a balancing action between users' needs, available development resources, and the technical specifications of standards. This paper explores an area of CAD/CAM systems development, particularly the implementation of the effective exchange files translators'. A new approach is introduced, which proposes to enclose all the translation operations concerning each exchange format to a separate DLL, thus making a 'plug-in.' Then, this plug-in could be used together with the CAD/CAM system or with specialized translation software. This approach allows to create new translators rapidly and to gain the reliable, high-efficiency, and reusable program code. The second part of the paper concerns the possible problems of translators' development. These difficulties often come from the exchange standards' misunderstanding or ambiguity in standards. All examples come from the authors' practice experiences of dealing with CAD/CAM systems.

Space maintainer using CAD/CAM system without a band: a case report (CAD/CAM 시스템을 이용하여 band 없이 공간유지 장치를 제작한 증례)

  • Eun-Sook Kang
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.100-106
    • /
    • 2024
  • Early interceptive orthodontic interventions are often started in the developing dentition to guide normal occlusion. The simplest way to prevent eruption failure from deciduous tooth loss is to fix a space maintainer such as a band and loop. Band and loop space maintainer has several problems like cement loss, demineralization, locking of the adjacent tooth, and needs to take a pickup impression of the band. Computer-assisted design/computer-assisted manufacturing (CAD/CAM) space maintainer without band was developed to solve these problems. This case report describes successful eruption of the mandibular second premolar using CAD/CAM without a band.