• Title/Summary/Keyword: Sec-EM

Search Result 24, Processing Time 0.02 seconds

A Study on the Ship's Heading Stabilization of GPS Compass Using Electromagnetic Compass (전자자기 컴퍼스를 이용한 GPS 컴퍼스의 선수방위 안정화에 관한 연구)

  • Jo, Hyeon-Jeong;Shin, Hyeong-Il;Lee, Dae-Jae;Hyun, Yun-Ki;Bae, Mun-Ki;Kim, Kwang-Sik
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.41 no.1
    • /
    • pp.70-77
    • /
    • 2005
  • The study was results obtained from the trial make of the hybrid GPS-electromagnetic(EM) compass which overcome shortcoming of GPS compass and EM compass. The results were summarized as follows: GPS compass detected the stable ship's heading at 0.1^{\circ}$ intervals with the turning angular velocity of less than 25^{\circ}$/sec in the experiment for the characteristics of turning angular velocity with stepmotor, but in case of over 25^{\circ}$/sec the compass did not detect it. On the contrary, the EM compass always indicated the ship's heading with no connection of the turning angular velocity, however the compass is low accuracy compared with GPS one owing to a compass error. The ship's headings by the hybrid GPS-EM compass were displayed at fixed point and moving by car; if the GPS compass work the headings were displayed by GPS compass, if not, the heading is provided stably by adding or subtracting of a compass error to the heading of EM compass. Also, each ship's heading was derived from not only the GPS compass but also the EM one by add or subtract of the compass errors, and then was worked covariance for the analogy. The results show that the ship's heading of two compasses has been verified the similarity to 95% confidence level.

A Study on Floating Collar of Dragged Gears (인망그물의 부양깃판에 관하여)

  • 장지원
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.22 no.1
    • /
    • pp.1-5
    • /
    • 1986
  • In order to improve the net-mouth height of dragged gears, the authors devised models of floatingcollars of nylon cloth instead of floats and experimented with 4 types-A type (length 65em, breadth 3em), B type (length 65em, breadth 4em), C type (length 65em, breadth 5em) and D type (length 65 em, breadth 6em) attached respectively to the front edge of square of a model net after preliminary experimentation. These various types of floating collars were experimented in a circulating water channel to evaluate the characteristics of net-mouth height and hydrodynamic resistance and the effect of the length of bridles were also examined. The results obtained were as follows: 1. In case of attaching floats, the model net-mouth height reduced from 80 em to 20 em when current velocity was increased from 0.25m/see to 1m/sec. 2. In case of attaching floating collars, the model net-mouth heights were maintained 70 em, 71 em, 80 em, 78 em in maximum and 55 em, 63 em, 69 em, 73 em in minimum respectively even the current volocity was increased from 0.25 m/see to 1 m/see. 3. The model net-mouth height was reduced to 10 em maximum according to the current velocity and types of floating collars when the bridles were shortened 3~4 mm in length. 4. Hydrodynamic resistance of D type only was increased to 700 g in maximum and those of A, B, C type were reduced to 460 g in maximum at current velocity beyond 0.5 m/ see when bridles were shortened 3-4 mm in length. 5. But the model net-mouth heights became higher in accordance with breadth of floating coliars, B type was the best for this model net in case that hydrodynamic resistance was taken into account.

  • PDF

Joule Heating Effects and Initial Resistance in Electromigration Test (EM시험에서의 Joule Heating 영향 및 초기저항값)

  • Ju, Cheol-Won;Gang, Hyeong-Gon;Han, Byeong-Seong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.6
    • /
    • pp.436-441
    • /
    • 1999
  • Joule heating effect in EM(Electromigration) test were performed on a bend test structure. EM test is done under high current densities(1.0-2.5MA/cm2), which leads to joule heating. Since joule heating is added to the controlled oven(stress) temperature, themetal line temperature is higher than the stress temperature. The increase in the stress temperature due to joule heating is important because EM phenomena and metal line failure are related to the stress temperature. In this paper, metal line was stressed with a current density of 1.0 MA/$cm^2$, 1.5MA/$cm^2$, 2.0MA/$cm^2$, 2.5MA/$cm^2$, for 1200 sec and temperature increase due to joule heating was less than $10^{\circ}C$. Also it took 30 minutes for the metal line to equalized with oven temperature. Recommendations are given for the EM test to determine the initial resistance of EM test structure under stress temperature and current density.

  • PDF

Limitation of Light Energy Utilization in the Fallen Stems of Opunttia bigelovii without CO2 and Water Absorption (지상에 떨어진 Opunttia bigelovii 선인장의 줄기에 있어서 광에너지의 이용한계)

  • Chang, Nam-Kee
    • The Korean Journal of Ecology
    • /
    • v.3 no.1_2
    • /
    • pp.31-39
    • /
    • 1980
  • Light energy utilization was investigated in the fallen stems of Opuntia bigelovii. Threshold time for the decreasing steady state of acid accumulation in the palisade tissue of Opuntia stems was 4 hours under 1,000 $\mu Em^{-2}sec^{-1}$ of PAR at $75^{\circ}C$, while stomatal closing throughout the stem stage was illustrated by 256.0-310.4 sec $\textrm{cm}^{-1}$ of stem diffusive resistance and 0.20g $day^{-1}$ of the water loss rate as cuticular resistance. The acid loss rate in the stems per 4 hours was related to tissue water contents and a few acid loss rate could be recognized at the water content rage of 56.4%~46.8%. Endogenous oscillation of tissue acidity due to the diurnal rhythmic phenomena depended on the tissue water content was found in the Opuntia stems with stomatal closing during the normal day/night cycle. The survival rate of 1 segment to survive 2 years old cactus was 22.7% in desert environments. Such a compensation photosynthesis which utilizes light energy and maintains the reassimilation of endogenous gases was interpreted as conceptual model.

  • PDF

A Study on Sensor Motion-Induced Noise Reduction for Developing a Moving Transient Electromagnetic System (이동하면서 측정할 수 있는 시간영역전자탐사 시스템 개발을 위한 센서흔들림유도잡음 제거 연구)

  • Hwang, Hak Soo;Lee, Sang Kyu
    • Economic and Environmental Geology
    • /
    • v.31 no.1
    • /
    • pp.53-57
    • /
    • 1998
  • Transient electromagnetic (TEM) method is also affected by cultural and natural electromagnetic (EM) noises, since it uses part of the broadband ($10^{-2}$ to $10^5Hz$) spectrum. Especially, predominant EM noise which affects a moving transmitter-receiver TEM system is sensor motion-induced noise. This noise is caused by the sensor motion in the earth magnetic field. The technique for reducing the sensor motion-induced EM noise presented in this paper is based on Halverson stacking. This Halverson stacking is generally used in a time-domain induced polarisation (IP) system to reject DC offset and linear drift. According to spectrum analysis of the vertical component of sensor motion-induced noise, the frequency range affected by the motion of an EM sensor is less than about 700 Hz in this study. With the decrease of the frequency, the spectral power caused by the motion of a sensor increases. For example, at the frequency of 200 Hz, the spectral power of the sensor motion-induced noise is $-90dBVrms^2$ while the spectral power of the EM noise measured with a fixed sensor on the ground is $-105dBVrms^2$, and at the frequency of 100 Hz, the spectral power of the sensor motion-induced noise is $-70dBVrms^2$ while the spectral power of the EM noise measured with a fixed sensor on the ground is $-105dBVrms^2$. With applying Halverson stacking to an artificial noise transient generated by adding a noise-free transient to sensor motion-induced noise measured without pulsing, it is shown that the filtered transient is nearly consistent with the noise-free transient within a delay time of $0.5{{\mu}sec}$. The inversion obtained from this filtered transient is in accord with the true model with an error of 5%.

  • PDF

Vitrification of Bovine Embryos with Various Containers

  • Kim, Young-Mi;Ko, Dae-Hwan;Saen, Chung-Kil;Lee, Hoon-Teak
    • Proceedings of the KSAR Conference
    • /
    • 2003.06a
    • /
    • pp.29-29
    • /
    • 2003
  • The objective of this study is to examine an effective cryopreservation method and various vitrification containers on the survival vates of embroys. For the vitrification, in vitro produced embryos at blastocyst stage were exposed to ethylene glycol 5.5 M freezing solution (EG5.5) for 20 sec, loaded on containers such as grid, straw and paper and then immediately plunged into - 196$^{\circ}C$ L$N_2$. The blastocysts were thawed serially in 0.5, 0.25 and 0.125%; P < 0.05). Therefore, this study suggests that bovine embryos can be easily, effectively and successfully cryopreserved by grid, straw, and paper in the presence of freezing solution. Furthermore, vitrification using paper may be used as a no M sucrose in CR1aa, each for 1 min, and cultured in CR1 an medium supplemented with 10% FBS. After thawing, there were not significant differences in recovery rates of EM grid, straw and paper as 84.6, 88.3, and 93.7%, respectively (Table 1). However, survival rates of EM grid (78.1%) and paper (77.1%) showed significantly higher than straw (52. 1w method for bovine embryos.

  • PDF

Adaptive and Recursive Tracking of Unpaved Roads (무인주행차량을 위한 비포장 도로추적)

  • Chung, Hong;Koo, Bon-Seok
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 1999.10b
    • /
    • pp.548-550
    • /
    • 1999
  • 무인 주행 차량에 있어서, 포장 또는 비포장 도로의 시각적 추적은 매우 중요한 문제중의 하나이다. 따라서, 비디오 이미지로부터 비포장 도로를 추적할 수 있는 신속한 비젼 알고리즘의 개발이 필요하다. 이 논문에서는 칼만 필터와 EM(Expectation Maximization) 이론을 이용해 도로를 예측하고 시스템 파라미터를 갱신하는 방법을 제시한다. 시스템 파라미터, 도로 state, 도로 경계선, 그리고 모든 과거 데이터들을 각각 EM 파라미터, hidden data, incomplete data와 complete data로 정의함으로서 도로 state를 예측하고 시스템 파라미터를 추정할 수 있는 시간 회귀적 수식을 유도해 낼 수 있다. 이러한 방법을 이용하여 도로 state는 칼만 필터에 의해 매 프레임마다 예측되며, 시스템 파라미터들은 주기적으로 갱신되는 것이다. 결과적으로 이 방법은 주변환경과 날씨에 많은 영향을 받는 도로의 모양과 특징을 잘 찾아낼 수 있다. 또한 도로의 다음 state를 예측할 수 있는 점을 이용하면 계산량을 줄일 수 있으므로 실시간 구현에 용이하다. 이와 같은 방법으로 우리는 0.1 sec/frame 처리속도를 보장하는 도로추적 시스템을 구현하였다.

  • PDF

Development of Bovine Embryos after Vitrified-Thawed with Electron Microscope Grid and Open Pulled Straws

  • Lee, Y. J.;D.H. Ko;Lee, H. T.;K. S. Chung
    • Proceedings of the KSAR Conference
    • /
    • 2001.03a
    • /
    • pp.76-76
    • /
    • 2001
  • The objective of this study was to optimize the vitrification method of in vitro produced bovine embryos. Thus, in vitro produced embryos at 8 cell, morula and blastocyst stages were vitrified on electron microscope grids (EM grids) or in open pulled straws (OPS) with EG5.5 (5.5 M ethylene glycol, 1.0 M sucrose and 10% FBS in m-DPBS medium) freezing solution and their survival rates after thawing were compared. The embryos on EM grids or in OPS were briefly exposed to EG5.5 freezing solution and plunged directly into liquid nitrogen within 30 to 35 sec. Post-thawed embryos were serially diluted in 0.5, 0.25 and 0.125 M sucrose in m-DPBS, each for 1 min, and then cultured in CRI aa medium supplemented with 10% FBS. Embryonic survival rate was assessed as re-expanded and hatched rates of those embryos after warming. The rates of re-expansion embryos did not significantly different between EM grid (8 cell: 42.10%, morula: 66.66% and blastocyst: 77.08%) and OPS (8 cell: 47.36%, morula: 61.90% and blastocyst: 83.33%) methods. In addition, the hatched rates in EM grid (8 cell: 31.57%, morula: 57.14% and blastocyst: 72.91%) were similar to those in OPS (8 cell. 34.21%, morula: 50.00% and Blastocyst: 77.08%). Interestingly, even at the same blastocyst stage, the in vitro survival of day 7 embryos (EM grid: 79.48 and OPS: 87.18%) was higher than those of day 8 embryos (EM grid: 72.10 and OPS: 82.06%). The total cell number of blastocyst developed in vitro after vitrification was examined with Hoechst 33342 staining to compare the embryo quality among different treatment groups. The total cell number of blastocyst was not significantly different between vitrified groups (EM grid: 162.4$\pm$8.0 and OPS: 158.4$\pm$7.1) and unvitrified control (168.0$\pm$5.6). These results indicate that both vitrification containers can provide the high rate of embryo survival. Moreover, the OPS container may not need a cap to protect the container from floating after immersion in L$N_2$. Therefore, this study suggest that bovine embryos can be cryopreserved easily, effectively and successfully by vitrification method using EM grid or OPS with EG5.5 freezing solution. In the future, the Pregnancy rate would be investigated after transfer of our vitrified embryos into the appropriated recipients.

  • PDF

Circulation Experiment of the Chinhae Bay using a Three-Dimensional Diagnostic Numercal Model (3차원 진단모델을 이용한 진해만의 수치유동실험)

  • 배삼완
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.33 no.4
    • /
    • pp.360-369
    • /
    • 1997
  • We calculated the residual current forced by buoyancy, wind stress, and tidal stress in the Chinhae Bay using a three-dimensional diagnostic model. The calculated current was also compared with the observation. The flow directs outward from the central area of the Bay in the upper layer, and also forms eddy-shape stucture in the upper and middle layers. The flow of bottom layer shows an opposite pattern compared to those of top and middle layers. The maximum speed was 6.05 em/see (September) and 3.49 cm/sec (November) in the upper layer, and 4.39 cm/sec on both month in the middle layer. The Kinetic energy of November (8.39xlO' W) was larger than that of September (1.24xlO 'W), mainly resulting from larger buoyancy effect in September. In spite of the roughness of the grid size(1 km) and wind date, the calculated flow shows eorrelation(r=0.71) with the observation. We expect that the correlation be increased by increased by adopting the fine grid and the variable coefficients of diffusion and viscosity.

  • PDF

Thrust - Performance Test of Ethylene-Oxygen Single-Tube Pulse Detonation Rocket

  • Hirano, Masao;Kasahara, Jiro;Matsuo, Akiko;Endo, Takuma;Murakami, Masahide
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.205-210
    • /
    • 2004
  • The pulse detonation engine (PDE) has recently expected as a new aerospace propulsion system. The PDE system has high thermal efficiency because of its constant-volume combustion and its simple tube structure. We measured thrust of single-tube pulse detonation rocket (PDR) by two methods using the PDR-Engineering Model (full scale model) for ground testing. The first involved measuring the displacement of the PDR-EM by laser displacement meter, and the second involved measuring the time-averaged thrust by combining a load cell and a spring-damper system. From these two measurements, we obtained 130.1 N of time-averaged thrust, which corresponds to 321.2 sec of effective specific impulse (ISP). As well, we measured the heat flux in the wall of PDE tubes. The heat flux was approximately 400 ㎾/$m^2$. We constructed the PDR-Flight Mode] (PDR-FM). In the vertical flight test in a laboratory, the PDR-FM was flying and keeping its altitude almost constant during 0.3 sec.

  • PDF