• Title/Summary/Keyword: Seat value

Search Result 108, Processing Time 0.024 seconds

CISG as a Governing Law to an Arbitration Agreement

  • Park, Eun-Ok
    • Journal of Korea Trade
    • /
    • v.25 no.7
    • /
    • pp.108-121
    • /
    • 2021
  • Purpose - This paper studies whether the CISG is applicable to the arbitration agreement when the validity of the arbitration agreement becomes an issue. To make the study clear, it limits the cases assuming that the governing law of the main contract is the CISG and the arbitration agreement is inserted in the main contract as a clause. Also, this paper discusses only substantive and formal validity of the arbitration agreement because the CISG does not cover the questions of the parties' capacity and arbitrability of the dispute. Design/methodology - This paper is based on scholarly writings and cases focusing on the principle of party autonomy, formation of contract and the doctrine of separability to discuss characteristic of arbitration agreement. In analyzing the cases, it concentrates on the facts and reasonings that show how the relative regulations and rules are interpreted and applied. Findings - The findings of this paper are; regarding substantive validity of arbitration agreement, the courts and arbitral tribunals consider general principles of law for the contract and the governing law for the main contract. In relation to formal validity of arbitration agreement, the law at the seat of arbitration or the law of the enforcing country are considered as the governing law in preference to the CISG because of the recognition and enforcement issues. Originality/value - This paper attempts to find the correlation between the CISG and the arbitration agreement. It studies scholars' writing and cases which have meaningful implication on this issue. By doing so, it can provide contracting parties and practitioners with some practical guidelines about the governing law for the arbitration agreement. Furthermore, it can help them to reduce unpredictability that they may confront regarding this issue in the future.

Playing God: Self-Reflection, Religion, and Morality in Muriel Spark's Fiction (신을 연기하기: 뮤리엘 스파크 소설의 자아반영성, 종교, 윤리)

  • Kim, Heesun
    • English & American cultural studies
    • /
    • v.18 no.4
    • /
    • pp.33-64
    • /
    • 2018
  • Through the experimental narrative construction by authorial divinity, Muriel Spark's novels and films based on her fiction show the difficulty of living like a human being under various inhumane and manipulative circumstances of the modern capitalistic society. By adopting flash-forward, self-reflection, and deceptive omnipotent viewpoints, her work has surprisingly predicted the post-modern trend in which humans are increasingly attracted and interpellated to the digitalized media. Muriel Spark called the recent anesthetic situation by stimulation "a driver's seat" because it is a symbol of how humans should act to maintain the critical subject. Emphasizing the value of self-reflection, religion and morality in the mechanized society, Muriel Spark stressed literature should play the role of helmsman who sails safely in the rough sea. In Muriel Spark's works, God is often synonymous with writers. As a Jewish immigrant she experienced alienation in Scotland, marital violence, prejudices of the London-based publishing world, Nazism, and Watergate. For her, the harsh reality of the modern society needs to be guided and complemented by something beyond human control. But rather than relying entirely on traditional Catholic doctrines such as Graham Greene and Evelyn Waugh, Muriel Spark has taken a personal, religious view of literature and insists that the genuine writer must play God's play. Seeking for the speculative vision for the future of human life in God's plan, she tries to understand the complex twisted motives of human beings which are often far from the ideal form. Simply put, her search of self-reflection, religion and ethics is modeled on the God's plan for the ideal human being who is supposed as the writer with the transfigurative imagination of the trinity.

Millennial parents' perception of babywearing products: A text analysis approach (밀레니얼 세대의 Babywearing 제품에 대한 인식: 텍스트 분석 접근)

  • Lee, Wan-Gee;Park, Myung-Ja;Lee, Kyu-Hye
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.23 no.2
    • /
    • pp.17-28
    • /
    • 2021
  • The baby-tech industry, which combines IT with existing parenting product, is attracting increasing amounts of attention. Consequently various types of baby products incorporating functionality and design are being launched. In recent years, particularly as the market segments increases for babywearing products, parenting products that account for the child's comfort and parents' convenience are required. Therefore, this study examines the characteristics and consumer perception of babywear products, which are important for the emotional stability, development, and rearing of children. The study utilizes text mining and a network analysis by collecting unstructured text data. An examination of the network, based on the frequency of keywords for each babywear product and the degree of the connection to the centering index, revealed that consumers value convenience and price when purchasing products. The consumer perception and consideration factors that appear individually according to the product were also identified. In addition, studying body parts with high TF-IDF values revealed a difference in the body parts considered by consumers for each product. Lastly, through the visualization data based on the keywords that appeared in public, commonly appearing keywords, and those that appeared individually were examined. Through SNS, product characteristics as well as a new parenting culture that shared child-rearing routines were confirmed. This study suggests planning and marketing directions for the development of babywear products that meet consumer needs.

A Design and Implementation of Product Information Guide System Based on Beacon

  • Lee, Won Joo;Yoo, Jung Hyun;Lee, Kang-Ho;Jang, Eun-Gyeom
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.12
    • /
    • pp.119-126
    • /
    • 2020
  • In this paper, we design and implement a product information guidance system Based on BLE beacons. This system is designed to provide various functions such as contactless entrance service through mobile ticket, seat guidance service, event push service, content push service, and public service. This system consists of three modules: a beacon recognition module, a server linkage module, and a content transmission module. The beacon recognition module implements a function of transmitting a specific ID of a nearby beacon when a customer with a smartphone approaches the available service area. The server linkage module recognizes the beacon ID value, transfers it to the server, and implements the function to check the location of the server having the ID. The content transmission module implements a function of transmitting event or service information set at a corresponding location to a smartphone. The beacon-based product information guidance system implemented in this paper has the advantage of being able to quickly and easily implement various product information guidance systems.

Electronic Attendance System Using Smart Device and High Frequency Signal

  • Myoungbeom Chung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.11
    • /
    • pp.103-111
    • /
    • 2023
  • Recently, many universities have used various electronic attendance systems such as NFC, QR code, Sound-QR, Bluetooth BLE authentication, and face recognition to process attendance. However, existing methods have various problems such as attendance errors due to deformation of authentication signals, mis-recognition attendance from outside the classroom, and difficulty to process seat absence during class. Therefore, this study proposes a high-frequency signal-based electronic attendance system to solve these problems and manage more accurate electronic attendance. As the high-frequency signal replaces the BLE signal, and the transmission range of the signal is limited to the classroom, and the signal value can be immediately changed if a change of the signal is needed. To verify the performance of the proposed system, we conducted a comparative experiment with the Bluetooth based electronic attendance system, and as a result, the proposed method showed high accuracy. Thus, the proposed method will be a useful service that can be immediately used in smart device-based electronic attendance system.

Accuracy and time efficiency of conventional and digital outlining of extensions of denture foundation on preliminary casts

  • Anne Kaline Claudino Ribeiro;Aretha Heitor Verissimo;Rodrigo Falcao Carvalho Porto de Freitas;Rayanna Thayse Florencio Costa;Burak Yilmaz;Sandra Lucia Dantas de Moraes;Adriana da Fonte Porto Carreiro
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.3
    • /
    • pp.139-150
    • /
    • 2024
  • PURPOSE. The purpose of this diagnostic study was to assess the accuracy and time efficiency of a digital method to draw the denture foundation extension outline on preliminary casts compared with the conventional technique. MATERIALS AND METHODS. A total of 28 preliminary edentulous casts with no anatomical landmarks were digitized using a laboratory scanner. The outlining of the entire basal seat of the denture was performed on preliminary casts and digitized. Casts with no extension outline were digitized and outlines were drawn using software (DWOS, Straumann). The accuracy of the extension outlined between both techniques was evaluated in the software (GOM Inspect; GOM GmbH) by file superimposition. Specificity and sensitivity tests were applied to measure accuracy. The paired t-test (95% CI) was used to compare the mean total area and the working time. RESULTS. The accuracy ranged from 0.57 to 0.92. The buccal and labial frenulum showed a lower value in the maxilla (0.57); while the area between the retromolar pad and buccal frenulum (0.64) showed a lower score in the mandible. The maxillary denture foundation and the working time for both arches were significantly longer for the digital method (P < .001). CONCLUSION. The denture foundation extension outline exhibited a sufficiently excellent accuracy for the digital method, except for the maxillary anterior region. However, the digital method required a longer working time.

Global Trends of Sciences Information on the Sour Gas (사워가스 학술정보 동향)

  • Cho, Jin Dong
    • Economic and Environmental Geology
    • /
    • v.48 no.1
    • /
    • pp.89-101
    • /
    • 2015
  • The sour gas is natural gas containing components such as hydrogen sulphide and carbon dioxide that form acids when mixed with water. Element sulfur precipitates from sour gas when reservoir pressure and temperature decrease. According to the International Energy Agency, about 43% of the world's natural gas reserves(2,580 tcf or 73.057 tcm), excluding North America, are sour. The sour gas is often derived from the Germanic word 'sauer or acidic' and the etymology referred to as 'sour'. Sour gas requires special handling and infrastructure because it contains significant amounts of hydrogen sulphide, making it highly corrosive, flammable and explosive, and there fore more costly and dangerous to process. So the business of sour gas is affected by two important factors: the economic value of the gas, and the methods used in its production. According to be analyzed in the academic literature to sour gas(2000~2014) by the program of 'web of science', the research activities 145 papers in sour gas.

Analysis of Principal Stress Distribution Difference of Tensile Plate with Partial Through-hole (부분 관통 구멍이 있는 인장판의 주응력 분포 차이 해석)

  • Park, Sang Hyun;Kim, Young Chul;Kim, Myung Soo;Baek, Tae Hyun
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.2
    • /
    • pp.437-444
    • /
    • 2017
  • Stress concentrations around discontinuities, such as a hole in cross section of a structural member, have great importance because the most materials failure around the region may be occurred. Stress on the point applied by concentrated load reaches much larger value than the average stress in structural member. In this paper, stress analysis was performed for the plate with a partial through-hole to find the difference of the principal stress distribution. The difference between maximum principal stress and minimum principal stress in photoelasticity is equal to the value obtained by multiplying the isochromatic fringe order by the fringe constant of the material divided by the distance through which the light passes, that is, the thickness of the specimen. Since the difference of principal stress is proportional to the photoelastic fringe order, the distribution of the principal stress difference by the finite element analysis can be compared with the photoelasticity experimental result. ANSYS Workbench, that is the finite element software, is used to compute the differences of principal stresses at the specific points on the measured lines. The computation values obtained by ANSYS are compared with the experimental measurements by photoelasticity, and two results are comparable to each other. In addition, the stress concentration factor is obtained using the stress distribution analyzed from the variation of hole depth. Stress concentration factor is increasing, as the depth of hole increase.

A STUDY ON THE FIT OF THE IMPLANT-ABUTMENT-SCREW INTERFACE (임플란트-지대주-나사의 적합에 관한 연구)

  • Kim Nak-Hyung;Chung Chae-Heon;Son Mee-Kyoung;Back Dae-Hwa
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.4
    • /
    • pp.503-518
    • /
    • 2003
  • Statement of problem : There have been previous studies about considerable variations in machining accuracy and consistency in the implant-abutment-screw interfaces. Purpose : The purpose of this study was to evaluate the machining accuracy and consistency of implant/abutment/screw combinations on two randomly selected implants from each of four manufactures. Material and methods : In this study, screws were respectively used to secure a cemented abutment, to a hexlock implant fixture ; teflon coated titanium alloy screw(Torq-Tite) and titanium alloy screw in Steri--Oss system, gold-plated gold-palladium alloy screw(Gold-Tite) and titanium alloy screw in 3i system gild screw ana titanium screw in AVANA Dental Implant system, and titanium screws in Paragon System. The implants were perpendicularly mounted in polymethyl methacrylate autopolymerizing acrylic resin block(Orthodontic resin, Densply International Inc. USA) by use of dental surveyer. Each abutment screw was secured to the implant with recommended torque value using a digital torque controller. Each screw was again tightened after 10 minutes. All samples were cross sectioned with grinder-polisher unit(Omnilap 2000 SBT Inc) after embeded in liquid unsaturated polyester (Epovia, Cray Valley Inc) Results : There were the largest gaps in the neck areas of screws in hexagonal extension implants which were examined in this study. The leading edge of the abutment screw thread (superior surface) was in contact with the implant body thread, and the majority of the contacting surfaces were localized to the middle portion of the mating threads. Considerable variation in the contacting surfaces was noted in the samples evaluated. Amounts of contact in the abutment screw thread were larger for assemblies with Gold-Tite screw, gold alloy screw. Torq-Tite screw than those with titanium screws. The findings of intimate contact between the screw and screw seat were seen in all samples, regardless of manufacturers. However, microgap between the head and lateral neck surface of the screw and the abutment could be dectected in all samples. The findings of intimate contact between the platform of the implant and the bottom of the abutment were consistent in all samples, regardless of manufacturers. However, microgaps between the lateral surface of external hex of the fixture and the abutment could be dectected in all samples. Conclusion : Considerable variations in machining accuracy and consistency were noted in the samples and the implant-abutment-screw interfaces were incomplete. From the results of this study, further development of the system will be required, including improvements in pattern design.

FIT OF FIXTURE/ABUTMENT INTERFACE OF INTERNAL CONNECTION IMPLANT SYSTEM (내측연결 임플란트 시스템에서 고정체와 지대주 연결부의 적합에 관한 연구)

  • Lee Heung-Tae;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.2
    • /
    • pp.192-209
    • /
    • 2004
  • Purpose : The purpose of this study was to evaluate the machining accuracy and consistency of implant/abutment/screw combination or internal connection type. Material and methods: In this study, each two randomly selected internal implant fixtures from ITI, 3i, Avana, Bicon, Friadent, Astra, and Paragon system were used. Each abutment was connected to the implant with 32Ncm torque value using a digital torque controller or tapping. All samples were cross-sectioned with grinder-polisher unit (Omnilap 2000 SBT Inc) after embeded in liquid unsaturated polyester (Epovia, Cray Valley Inc). Then optical microscopic and scanning electron microscopic(SEM) evaluations of the implant-abutment interfaces were conducted to assess quality of fit between the mating components. Results : 1) Generally, the geometry of the internal connection system provided for a precision fit of the implant/abutment into interface. 2) The most precision fit of the implant/abutment interface was provided in the case of Bicon System which has not screw. 3) The fit of the implant/abutment interface was usually good in the case of ITI, 3I and Avana system and the amount of fit of the implant/abutment interface was similar to each other. 4) The fit of the implant/abutment interface was usually good in the case of Friadent, Astra and Paragon system. The case of Astra system with the inclined contacting surface had the most Intimate contact among them. 5) Amount of intimate contact in the abutment screw thread to the mating fixture was larger in assembly with two-piece type which is separated screw from abutment such as Friadent, Astra and Paragon system than in that with one-piece type which is not seperated screw from abutment such as ITI, 3I and Avana system. 6) Amount of contact in the screw and the screw seat of abutment was larger in assembly of Friadent system than in asembly of Astra system of Paragon system. Conclusion: Although a little variation in machining accuracy and consistency was noted in the samples, important features of all internal connection systems were the deep, internal implant-abutment connections which provides intimate contact with the implant walls to resist micro-movement, resulting in a strong stable interface. From the results of this study, further research of the stress distribution according to the design of internal connection system will be required.