• Title/Summary/Keyword: Sealing Test

Search Result 289, Processing Time 0.027 seconds

Preliminary Design of Helicopter Fuel Tank (헬리콥터 연료탱크 기본설계)

  • Lee, Jung-hoon;Kim, Sung-chan;Kim, Hyun-gi
    • Journal of Aerospace System Engineering
    • /
    • v.2 no.2
    • /
    • pp.14-19
    • /
    • 2008
  • This paper presents the procedure and the results of the preliminary design of the fuel tank as a part of developing the helicopter. For the requirements of operational capability, MIL-DTL-27422D and Defence Standard 15-2/Issue 1 are considered to be applied in developing a helicopter fuel tank. The procedure of the fuel tank development is set up including interface plate design, tank design, former design, tank material lay-up, and tank installation assessment. The outer moulded line and fittings of fuel tank have being designed, and several test will be performed to get the qualification.

  • PDF

An Experimental Study on the Mass and Energy Release for a Hot Leg Break LBLOCA During Post Blowdown

  • S.J. Hong;Kim, J.H.;Park, G.C.
    • Nuclear Engineering and Technology
    • /
    • v.32 no.2
    • /
    • pp.108-127
    • /
    • 2000
  • Hot leg break LBLOCA(Large Break LOCA) had a potential to be a containment maximum pressure accident in YGN3&4, which was induced from excessive conservatism in the CE analysis methodology of mass and energy release. This study conducted mass and energy release experiment for the hot leg break LBLOCA during post blowdown with an integral test facility, SNUF(Seoul National University Facility). This facility simulated YGN 3&4 with volume ratio of 1/1140 based on Ishii's three level scaling. Experiment showed that SI(Safety Injection) water refilled cold leg first and core later. SI water was vaporized in the core, which resulted in the repressurization of reactor. This increase of pressure drove the water in cold leg to flow up half height of U tubes. However, since the water was drained back soon, the release through the SG side broken section by evaporation was negligibly small. This study also provided experimental assessment of RELAP5 results by KAERI for the release through the SG side broken section.

  • PDF

Befitting Test of Magnetic Fluid to Speaker Damper (자성유체의 스피커 댐핑효과에 관하여)

  • 이효숙;유제광
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.2
    • /
    • pp.93-98
    • /
    • 1998
  • Magnetic fluids have been used in the commercial area, e. g damping, sealing and hydrodynamic bearing. In this study, magnetic fluid was made for damping in loudspeaker. The magnetic fluids were snthesized by dispersing the magnetite powder which was obtained by precipitation method in Yubase oil. When the magnetic fluid was applied to a 6 cm tweeter, improvements of damping, centering and heat transger in a loudspeaker were noted. Also we compared the performance of the magnetic fluid with 20 % magnetite in the oil and the one of APG-815 (Niphon Ferrofluidic Co.)

  • PDF

Experimental Study of the Joint Movement Responsiveness Performance to the One-Component Silicon Sealants at Curing Phase (경화단계에서의 1성분형 실리콘 실란트의 거동대응성능에 관한 실험적 연구)

  • Son, Jong-Won;Ono, Tadashi
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.63-64
    • /
    • 2014
  • In this study, we has a purpose to estimate the joint movement responsiveness performance for the domestic products of one-component structural silicon sealants. For this purpose, we make a comparative study for the four domestic products focused on tensile properties after allowed the cyclic-movements for three days at initial step of curing phase. A joint movement range ±10% and the rate of compression and extension 3.2mm/h were assumed in those tests. As a result, the large space were induced inside the sealant by rupture, and then adhesion and cohesion failures were caused by stress concentration. The tensile properties were reduced by 15~60% in comparison with physical properties. In this case, the generating defect was caused and the service-life was decreased. Thus, further researches as relationship of test condition and products properties on this behavior would be studied.

  • PDF

Simulation and Experiment of Elastomer Seal for Pneumatic Servo Cylinder

  • Hur, Shin;Song, Kyung Jun;Woo, Chang Su
    • Elastomers and Composites
    • /
    • v.50 no.4
    • /
    • pp.251-257
    • /
    • 2015
  • The rubber seal is a part inserted into servo cylinder to keep the air pressure constant. In order for efficient movements of the servo cylinder, the frictional coefficient of the rubber seal needs to be minimized while the sealing is maintained. In this work the friction characteristics of rubber seal specimen are tested on metal plate at various conditions. The experimental conditions include roughness level, applied pressure, lubrication, and rubbing speed. The design of experiment approach is taken to assess the effect of each parameter. The nonlinear frictional response of the rubber is applied to the FEM model simulating the servo cylinder movement. The result demonstrates that precise optimization of the servo cylinder movement must be preceded by preliminary experiments coupled with the theory and FEM model.

Studies on the Development of Sustained Release Preparation (I) Preparation and Evaluation of CAP Microcapsules of Sodium Ascorbate (지속성 제제의 개발에 관한 연구 (I) 아스코르빈산 나트륨의 CAP 마이크로캅셀의 제조 및 평가)

  • Shin, Sang-Chul;Koh, Ik-Bae
    • Journal of Pharmaceutical Investigation
    • /
    • v.21 no.4
    • /
    • pp.253-262
    • /
    • 1991
  • Microencapsulation of sodium ascorbate with cellulose acetate phthalate(CAP) by coacervation/ phase separation method were carried out. Various factors affecting microencapsulation, i.e., surfactant concentration. CAP concentration, stirring speed and treatment of spermaceti as a sealing agent were studied. Dissolution rate. particle size distribution, surface feature and stability test were investigated. CAP microcapsules prepared using 0.5% span 80 as a surfactant showed smooth and round surfaces. The release of sodium ascorbate was retarded by microencapsulation with CAP and by sealant treatment with spermaceti. When triturated with sodium bicarbonate, CAP microcapsules were more stable than unencapsulated sodium ascorbate under various RH conditions at $37^{\circ}C$.

  • PDF

Development and Design of Pulse Gun for Combustion Stability Rating Test (연소 안정성 평가 시험을 위한 펄스건 설계 및 개발 시험)

  • Go,Yeong-Seong;Lee,Gwang-Jin;Lee,Su-Yong;Lee,Dae-Seong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.9
    • /
    • pp.103-109
    • /
    • 2003
  • The development of a pulse gun used for the combustion stability rating test(SRT) has been domestically tried out since the SRT should be accompanied in the process of the development of LREs. At the beginning of the development, a rupture problem of the pulse gun body had been solved by changing its material and increasing its thickness. Also, the sealing test was undertaken for a pulse gun equipped with a membrane before conducting a explosion test and by using a specially designed jig after a explosion test. Since it is appropriate to reuse the holder of a pulse gun cavity for an actual SRT, a series of experiments for several variants has been taken to make it reusable. After all, the solution for a reusable holder of a pulse gun has been found and applied for complementing its specification.

A Study on Comparison of Outdoor Wind Pressure Performance According to Outdoor Exposure and Acceleration Deterioration Methods of Structural Sealants Applied to Curtain Wall (커튼월에 적용된 구조용 실링재의 옥외폭로와 실내복합열화 처리방법에 따른 내풍압성능 비교연구)

  • Jang, Pil Sung;Hong, Soon Gu;Kim, Sung Rae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.279-287
    • /
    • 2018
  • Sealants are an important element of modern architecture and serve as a building protection against weathering by providing barriers against ingress of moisture, air, and other materials. Exposure to a variety of environments often reduces lifespan due to changes in physical, chemical and mechanical characteristics, and UV, humidity, and temperature expansion are important issues that are directly related to durability. In this study, a combined deterioration test chamber was developed to simulate the environment of the open air as an instrument for verifying the durability of structural sealing materials indoors. In order to replicate special weather conditions, such as yellow dust, acid rain, and contamination by microorganisms, it was deemed impossible to replicate the outdoor environment by 100 %, and the results of the results of the results of the external exposure test of the structural sealant and the combined deterioration testing device. As a result of the displacement test of the outdoor exposure test, it was determined that the sealant was breaking apart and that it would be smooth, and the displacement would be up to three times greater than the initial material value of 1 year. The displacement test results of the combined deterioration test device show the tendency to deteriorate, decreasing the elasticity and tensile characteristics. In the case of denatured silicon, the current 400 cycles have been completed to confirm 12 months of degradation of the external exposure. The deformation of the test specimen cannot be verified with the naked eye, so it is considered that the conditions of the specimen are more stable than the silicon sealant. As a result of the outdoor exposure test, if the combined deterioration test device is structured and proposed in the relevant guidance or specification, the anticipated lifespan of 12 months in the actual use environment can be verified indoors and below 3 months later, economically.

Influence of Carbon Content on the Mechanical Properties of the Ni-Co Alloy (Ni-Co 합금강의 기계적 특성에 대한 탄소함량의 영향)

  • Choi, Byung-Ky;Jang, Kyeung-Cheun;Choi, Byung-Hui;Lee, Kee-Ahn
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.15 no.5
    • /
    • pp.7-13
    • /
    • 2006
  • This study was to evaluate the effect of carbon content on metallic change and fatigue characteristics with Fe-29%Ni-17%Co, low heat expansion alloy, widely using electronic components, precision machines, and sealing with glass and metal etc. The steels were fabricated with variation of carbon content, 0, 0.03, 0.06, 0.1, and 0.20% with VIM and tensile test and fatigue test were performed to achieve the above purpose. The more carbon content, the higher hardness value and yield strength. But elongation of 0.03%C, 0.06%C, and 0.10%C specimen decreased about 2.2%, 1.5% and 0.8% respectively more than that of the base metal. Especially the strength and elongation of 0.20%C specimen increased simultaneously about 14.4% and 7.5%. Fatigue life of 0.03%C specimen decreased but the more carbon content, the higher fatigue life over 0.06% carbon content more than that of base metal.

Build and Performance Test of a 3-cell Solid Oxide Fuel Cell Stack

  • Cho, Nam-Ung;Hwang, Soon-Cheol;Han, Sang-Moo;Yang, Choong-Jin
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.8
    • /
    • pp.407-411
    • /
    • 2007
  • A 3-cell stacked anode-supported solid oxide fuel cell was designed and fabricated to achieve a complete gas seal and the facile stacking of components. The stack was assembled with a unit cell with $10{\times}10cm^2$ area, and each cell was interconnected by a stainless steel 430 separator using a proprietary sealant sheet. The stack performance was examined at various gas flow rates of $H_2+3.5vol%\;H_2O$, and air at a fixed temperature of $800^{\circ}C$. No gas leakage was found from the sealing between cells and inter-connects within a measurement system in this research during a prolonged time of 500 h in operation. The test resulted in an open circuit voltage of 3.12 V, a peak power of 149 W, and a power density of $0.61W/cm^2$, while the long term durability of the power showed 19.1% degradation during the prolonged time of 500 h when tested at $800^{\circ}C$.