• Title/Summary/Keyword: Sealing Material

Search Result 306, Processing Time 0.027 seconds

2 Component Adhesive Leakage Repair Sealant Evaluation (2액형 점착 실링재의 누수보수재 평가에 관한 연구)

  • Cho, Il-Kyu;Kim, Keun-Hur;Oh, Sang-Keun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.4
    • /
    • pp.396-403
    • /
    • 2016
  • This study is based on the evaluation of a single component injection type adhesive repair material and a new 2 component type used in leakage of underground concrete structures. The studies showed that based on different mix ratio of the 2 component type adhesive sealant comprised of an asphalt main and latex mixture agent the viscosity of the material compound differed significantly. Based on a permeability testing, injection and economic efficiency, and performance, the appropriate ratio was determined to be 6:1 and was proceeded to the KS F 4935 evaluation method. The 2 component type adhesive sealant uses a static mixer and a cartridge type container for the injection procedure and was able to satisfy the evaluation criteria outlined in the KS F 4935 standard.

Safety Evaluation of a Shipping Capsule for Special Form Radioisotope (특수형 방사성 동위원소 운반캡슐의 안전성 평가)

  • Lee, Ju-Chan;Seo, Ki-Seog;Ku, Jeong-Hoe;Bang, Kyoung-Sik;Han, Hyon-Soo;Park, Seong-Won
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.1
    • /
    • pp.35-43
    • /
    • 2001
  • All of sealing capsules to transport a special form radioactive material should be designed and fabricated in accordance with the design criteria prescribed in IAEA standards and domestic regulations. The objective of this study is to demonstrate the safety of a shipping capsule for $^{192}Ir$ special form radioisotope which produced in the HANARO. The safety tests were carried out for the impact, percussion, bending and heat test conditions. And leakage tests were carried out before and after the each test. Also, the safety analyses wert performed using computer codes in order to verify the test results. The capsule showed slight scratches and deformation, and maintained its structural and thermal integrities in all tests without any severe damage or melting. It also met the allowable limits of leakage rate after each test. Therefore, it has been verified that the capsule was designed and fabricated to meet all requirements for the special form.

  • PDF

The Development of the Contamination Prevention Module of an Optical Window Using Ultrasonic Waves (초음파를 이용한 광학창 오염방지 모듈 개발)

  • Lee, ChangHee;Jeon, KiMun;Shin, JaeSoo;Yun, JuYoung;Cho, Seonghyun;Kang, Sang-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.4
    • /
    • pp.175-180
    • /
    • 2013
  • We developed the contamination prevention module of an optical window for an In-Situ Particle Monitor (ISPM) system. the core part of the module is the generator of an ultrasonic wave and the module is to remove particles stuck to the window by the transfer of the wave force to the window surface. In order to enhance transfer efficiency of the waves the frequency of the ultrasonic wave was optimized and a low impedance material (plexiglass) and a soft sealing material (Si rubber) were used. The ISPM with the developed module was installed at the exhaust line of a BPSG CVD equipment and the effect of the module was verified.

An analysis on the drop impact simulation of dual pump cap container made of eco-friendly materials (친환경 소재로 형성된 듀얼 펌프캡 용기의 낙하충격 시뮬레이션 분석)

  • Wi, Eun-Chan;Ko, Min-Sung;Kim, Hyun-Jeong;Lee, Joong-Bae;Kim, Min-Su;Lee, Joo-Hyung;Kong, Jung-Shik;Baek, Seung-Yub
    • Design & Manufacturing
    • /
    • v.15 no.1
    • /
    • pp.57-65
    • /
    • 2021
  • Pump cap is a product that is widely used due to its ease of use and simple operation. These pump caps are applied to heterogeneous functional cosmetics and are being developed as dual pump caps. However, the conventional dual pump cap has a problem in that it is inconvenient to use and leakage occurs. In addition, it is formed of a plurality of materials, and there is a problem that is difficult to recycle. Lately, since the problem of environmental pollution is getting serious, the dual pump cap, which is difficult to recycle, cannot be used. Currently, eco-friendliness has been considered in Korea, and there are no dual pump cap containers with excellent sealing performance. Therefore, in this study, a dual pump cap container made of eco-friendly material was designed. In addition, finite element analysis was performed to verify the design feasibility of the product.

In Vitro Evaluation of Microleakage and Penetration of Hydrophilic Sealants Applied on Dry and Moist Enamel (법랑질 수분 처리에 따른 친수성 치면열구전색제의 미세누출과 열구 침투도 평가)

  • Ku, Jaewon;Lee, Jewoo;Ra, Jiyoung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.3
    • /
    • pp.272-279
    • /
    • 2017
  • This study aimed to evaluate the microleakage and penetration of two hydrophilic sealants, Embrace $Wetbond^{TM}$ and Ultraseal $XT^{(R)}$ $hydro^{TM}$, when applied on dry and moist enamel, as compared to a conventionally used hydrophobic sealant, $Clinpro^{TM}$. A total of 60 sound human third molars were randomly divided into 5 groups according to the enamel moisture control and the sealant material used. After sealant application, the teeth were thermocycled and immersed in 1% methylene blue dye. Subsequently, the teeth were sectioned twice and the sections were examined using an optical microscope and image analysis software. Application of Embrace $Wetbond^{TM}$ on either dry or moist enamel resulted in more microleakage than $Clinpro^{TM}$. Application of Ultraseal $XT^{(R)}$ $hydro^{TM}$ on dry enamel showed a similar level of microleakage to $Clinpro^{TM}$, but application on moist enamel resulted in more microleakage. There were no significant differences between the groups in penetration. In conclusion, application of hydrophilic sealants on moist enamel did not improve the sealing ability and showed lower sealing ability than that of $Clinpro^{TM}$ applied on dry enamel.

Studies on the Improvement of Packaging of Retorted Samgyetang (레토르트 삼계탕의 포장 개선을 위한 연구)

  • Lee, Jin-Hwan;Lee, Keun-Taik
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.15 no.2
    • /
    • pp.49-54
    • /
    • 2009
  • The effects of filling temperatures of broth and degassing method on the residual oxygen content and gas composition in the pouch and physical strength of packaging material for Samgyetang depending on the contamination of broth on the sealing layer and sterilization process were investigated. The residual oxygen content in the broth and the oxygen proportion in the headspace of package were decreased with the increase of broth temperature at filling into the pouch from 50 to 100. When the products were packaged as air-contained (Air), manually squeezed the upper side of package out to minimize the headspace (Degas) and flushed with nitrogen gas ($N_2$-Flushing) while maintaining the broth temperatures of Samgyetang at 50 or 85. The residual oxygen content and oxygen proportion were increased in the order of $N_2$-Flushing

  • PDF

The effects of total-etch, wet-bonding, and light-curing of adhesive on the apical seal of a resin-based root canal filling system (접착제의 접착변수가 레진계 근관충전제의 근단밀폐효과에 미치는 영향)

  • Ryu, Won-Il;Shon, Won-Jun;Baek, Seung-Ho;Lee, In-Han;Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.5
    • /
    • pp.385-396
    • /
    • 2011
  • Objectives: This study evaluated the effects of adhesion variables such as the priming concepts of canal wall and the curing modes of adhesives on the sealing ability of a resin-based root canal filling system. Materials and Methods: Apical microleakage of the Resilon-RealSeal systems filled with 3 different combinations of adhesion variables was compared with the conventional gutta-percha filling using a dye penetration method. Experimental groups were SEDC, Resilon (Resilon Research LLC) filling with self-etch RealSeal (SybronEndo) primer and dual-cure RealSeal sealer; NELC, Resilon filling with no etching, Scotchbond Multi-Purpose (3M ESPE) primer application and light-curing adhesive; and TELC, Resilon filling with Scotchbond Multi-Purpose primer and adhesive used under total etch / wet bonding and lightcure protocols. GPCS, gutta-percha filling with conventional AH26 plus sealer, was the control group. Results: The median longitudinal dye penetration length of TELC was significantly shorter than those of GPCS and SEDC (Kruskal-Wallis test, p < 0.05). In the cross-sectional microleakage scores, TELC showed significant differences from other groups at 2 to 5 mm from the apical foramen (Kruskal-Wallis test, p < 0.05). Conclusions: When a resin-based root canal filling material was used, compared to the self-etching primer and the dual-cure sealer, the total etch/wet-bonding with primer and light-curing of adhesive showed improved apical sealing and was highly recommended.

Microleakage of Endodontic Temporary Restorative Materials under Dynamic Loading (동적하중 하에서 근관치료용 임시충전재의 미세누출의 평가)

  • Jung, Dong-Ho;Noh, Young-Sin;Lee, Hae-Doo;Chang, Hoon-Sang;Ryu, Hyun-Wook;Min, Kyung-San
    • Proceedings of the KACD Conference
    • /
    • 2008.05a
    • /
    • pp.198-203
    • /
    • 2008
  • The purpose of this study was to compare the sealing abilities of four endodontic temporary restorative materials using a methylene blue dye penetration test under dynamic loading. Standardized access cavities were prepared in forty-four intact human permanent molar teeth, and the cavities were restored with Caviton, MD-Temp, IRM, or ZOE. After thermocycling, an intermittent load of 98 N at 1 Hz was applied for 1,000 cycles to the long axis of the functional cusp of each of the teeth, which were immersed in a 1% methylene blue solution. The teeth were split in half, and the linear depth of dye penetration was evaluated according to the criteria. The results were analyzed using one-way ANOVA (p = 0.05) and Duncan's multiple range test. The results demonstrated that Caviton and MD-Temp showed significantly lower microleakage than IRM and ZOE. It was concluded that Caviton and MD-Temp exhibited better sealing ability than IRM and ZOE under dynamic loading.

  • PDF

Microleakage of Endodontic Temporary Restorative Materials under Dynamic Loading (동적하중 하에서 근관치료용 임시충전재의 미세누출의 평가)

  • Jung, Dong-Ho;Noh, Young-Sin;Lee, Hae-Doo;Chang, Hoon-Sang;Ryu, Hyun-Wook;Min, Kyung-San
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.3
    • /
    • pp.198-203
    • /
    • 2008
  • The purpose of this study was to compare the sealing abilities of four endodontic temporary restorative materials using a methylene blue dye penetration test under dynamic loading. Standardized access cavities were prepared in forty-four intact human permanent molar teeth, and the cavities were restored with Caviton, MD-Temp, IRM, or ZOE. After thermocycling, an intermittent load of 98 N at 1 Hz was applied for 1,000 cycles to the long axis of the functional cusp of each of the teeth, which were immersed in a 1% methylene blue solution. The teeth were split in half, and the linear depth of dye penetration was evaluated according to the criteria. The results were analyzed using one-way ANOVA (p = 0.05) and Duncan's multiple range test. The results demonstrated that Caviton and MD-Temp showed significantly lower microleakage than IRM and ZOE. It was concluded that Caviton and MD-Temp exhibited better sealing ability than IRM and ZOE under dynamic loading.

Determination of 226Ra in TENORM Sample Considering Radon Leakage Correction

  • Lim, Sooyeon;Syam, Nur Syamsi;Maeng, Seongjin;Lee, Sang Hoon
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.3
    • /
    • pp.127-133
    • /
    • 2021
  • Background: Phosphogypsum is material produced as a byproduct in fertilizer industry and is generally used for building materials. This material may contain enhanced radium-226 (226Ra) activity concentration compared to its natural concentration that may lead to indoor radon accumulation. Therefore, an accurate measurement method is proposed in this study to determine 226Ra activity concentration in phosphogypsum sample, considering the potential radon leakage from the sample container. Materials and Methods: The International Atomic Energy Agency (IAEA) phosphogypsum reference material was used as a sample in this study. High-purity germanium (HPGe) gamma spectrometry was used to measure the activity concentration of the 226Ra decay products, i.e., 214Bi and 214Pb. Marinelli beakers sealed with three different sealing methods were used as sample containers. Due to the potential leakage of radon from the Marinelli beaker (MB), correction to the activity concentration resulted in gamma spectrometry is needed. Therefore, the leaked fraction of radon escaped from the sample container was calculated and added to the gamma spectrometry measured values. Results and Discussion: Total activity concentration of 226Ra was determined by summing up the activity concentration from gamma spectrometry measurement and calculated concentration from radon leakage correction method. The results obtained from 214Bi peak were 723.4 ± 4.0 Bq·kg-1 in MB1 and 719.2 ± 3.5 Bq·kg-1 in MB2 that showed about 5% discrepancy compared to the certified activity. Besides, results obtained from 214Pb peak were 741.9 ± 3.6 Bq·kg-1 in MB1 and 740.1 ± 3.4 Bq·kg-1 in MB2 that showed about 2% difference compared to the certified activity measurement of 226Ra concentration activity. Conclusion: The results show that radon leakage correction was calculated with insignificant discrepancy to the certified values and provided improvement to the gamma spectrometry. Therefore, measuring 226Ra activity concentration in TENORM (technologically enhanced naturally occurring radioactive material) sample using radon leakage correction can be concluded as a convenient and accurate method that can be easily conducted with simple calculation.