• Title/Summary/Keyword: Screens

Search Result 553, Processing Time 0.024 seconds

A Study on the Nature of the Expression of Construction Fence Screens to enhance the Images of Cities - Focus on the fence screens of Seoul - (도시이미지 향상을 위한 공사 가림막 표현특성에 관한 연구 - 서울시 공사 가림막을 중심으로 -)

  • Oh, Sang-Min;Han, Young-Ho
    • Korean Institute of Interior Design Journal
    • /
    • v.20 no.3
    • /
    • pp.259-266
    • /
    • 2011
  • Today, construction fence screens which were understood simply as structures of separating people from the dangers of construction sites have evolved into landmarks to enhance the images of Cities. Now, construction fence screens should have the function as landmarks stimulating people's sensibility through providing aesthetic values as well as the function of protecting people from the dangers of fields of construction. For this reason, this study tried 1) to show the relationships among these 4 classifications. is 4 realms of Human Beings - Cultural - Ecological - Digital in the expression methods of the construction fence screens of Seoul and 2) to simplify the characteristic elements of construction fence screens by way of extracting with Ecology, Installation Art, Symbolic, Commercial Expression. This study examined whether or not the construction fence screens of Seoul were playing the role as landmarks stimulating people's sensibility with sustainable improvement to the environment of Seoul as public design structures, by investigating some of the construction fence screens of Seoul. Also through analyzing the diversity of expression methods of the construction fence screens of other local governments as well as those of Seoul, we hope that they will be the public structures for enhancing the images of Cities.

An Experimental Study on Characteristics of Pressure Drop of Screens Used in Horticultural Facilities (원예시설용 망의 압력강하 특성에 대한 실험적 연구)

  • Yum, Sung Hyun;Kang, Seung-Hee
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.55 no.6
    • /
    • pp.31-35
    • /
    • 2013
  • This study was carried out to present the pressure drop for various wind speeds through nine types of screens used in horticultural facilities. The screens have been widely used to prevent harmful insects from being entered into agricultural facilities, to reduce strong wind and to shade a light as well. Whatever the usage of the screens was, it was necessary to have good knowledge of how much the screen caused a pressure drop for wind speeds when analyzing both the inner thermal-flow distribution in the facility and the effect of reducing wind speed by using CFD. Furthermore, as for wind screens, the pressure drop for wind speeds was needed as a design load in evaluating the structural stability of the structures supporting the screens. Therefore, the pressure drop through the screens for wind speeds of 5~30 $m{\cdot}s^{-1}$ at about 5 $m{\cdot}s^{-1}$ interval and inflow angles of $0{\sim}45^{\circ}$ at an interval of $15^{\circ}$ was respectively measured in a subsonic wind tunnel. The relation of the pressure drop for various screens was well fitted as a secondorder polynomial expression.

Study on the improvement of the performance criteria for the Window Insect Screens (창호용 방충망의 성능기준 개선 방안)

  • Yeo, In-Hwan;Ok, Chi-Yeol;An, Jae-Hong;In, Ki-Ho;Min, Byung-Yeol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05c
    • /
    • pp.61-64
    • /
    • 2009
  • The number of apartment houses has accounted for more than 50% of all domestic residential types in Korea since 1980s. However, the apartment house has environmentally disadvantageous conditions such as highly residential-density and potential falls by children aged seven years and under through windows. In this study, we aim to suggest some ideas to improve domestic performance assessment methods and criteria of window Insect screens for protection on security and fall prevention by analyzing domestic standard with several overseas codes related to the screens for windows.

  • PDF

Evaluation of Overall Heat Transfer Coefficient of Different Greenhouse Thermal Screens Using Building Energy Simulation (BES를 이용한 온실용 보온커튼의 관류열전달계수 산정)

  • Rasheed, Adnan;Lee, Jong Won;Lee, Hyun Woo
    • Journal of Bio-Environment Control
    • /
    • v.27 no.4
    • /
    • pp.294-301
    • /
    • 2018
  • In winter, thermal screens are widely used to reduce heat loss from greenhouse to save energy. Unfortunately, not much data are available to the farmer to compare thermal screens while selecting the one that meets their specific requirements. Thus, there is a need to investigate the thermal performance of thermal screens. To address this issue, the Building Energy Simulation (BES) model of a hot box was used to calculate the overall heat transfer coefficient (U-value) of the thermal screens. To validate the model, computed and experimental U-values of single-and double-layered polyethylene (PE) material were compared. This validated model was used to predict the U-values of the selected thermal screens under defined weather conditions. We quantified the U-values of each selected material and significant changes in their U-values were noted in response to different weather conditions. Notably, the thermal properties of the tested screens were taken from the previous literature to calculate U-values using the BES model. The U-values of the thermal screens can help researchers and farmers evaluate their screens and make pre-design decisions that suit their investment capabilities.

Performance Analysis of Intake Screens in Power Plants on Mass Impingement of Marine Organisms (발전소 취수구에 대량으로 유입하는 해양생물에 대한 스크린 설비의 성능분석)

  • Lee, Jae-Hac;Choi, Hyun-Woo;Chae, Jin-Ho;Kim, Dong-Sung;Lee, Seung-Baek
    • Ocean and Polar Research
    • /
    • v.28 no.4
    • /
    • pp.385-393
    • /
    • 2006
  • Screening performance of the existing intake screens (drum and travelling screen) on mass impingement of marine animals, a euphausiid, Euphausia pacifica and a scyphozoan medusae, Aurelia aurita that have often clogged intake screens of the Uljin Nuclear Power Plant, was tested. The maximum tolerable densities of marine animals in the inflowing seawater upon the screen were estimated with two different approaches. First the maximum density of jellyfish was calculated from (1) passing amount of seawater per unit time through the screens and (2) the covered area of animals on the screens clogged. The maximum density of krill tolerable in the drum screen was cited from a simulated record of Uljin NPP, then those in the travelling screens were also calculated using the data of drum screen and ratio of seawater amount passing through the screens under the condition of 0.5m water column (W.C.) of the differential pressure (AP) produced by screens, an established permissible limit of ${\Delta}P$. Secondly, the screening performances were also tested by hydrodynamic measurements with various screen models in a circulating water channel equipped with a speed-controlling pump and a differential pressure gauge. From the first approach, the maximum tolerable densities of drum and travelling screen were calculated as 2.0 and $1.5ind/m^3$ for the Jellyfish and 900 and $680ind./m^3$ for the euphausiid, respectively. These densities estimated from the second approach were 2.1 and $0.8ind/m^3$ for the jellyfish and 1059 and $504ind/m^3$ for the euphausiid, respectively. These estimates were compared with the data from historic clogging events to evaluate the practical performance of these intake screens. The comparisons suggest a newly improved intake-screen of which performance should be at least seven times (approximately) better than the existing ones ior the krill and 3.2 times for the jellyfish, respectively, for preventing mass impingement, and for maintaining the condition of the differential pressure between the screens below 0.3 m W.C.

A Study on the Heat Transfer Augmentation by Using Wire-mesh Impinging Water Jet (충돌수분류계(衝突水噴流系)에서 와이어 메쉬를 사용(使用)한 열전달(熱傳達) 증진(增進)에 관(關)한 연구(硏究))

  • Na, G.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.6 no.3
    • /
    • pp.291-301
    • /
    • 1994
  • This paper presents the promotion of heat transfer through the use of wire-mesh screens. To improve heat transfer in an impingement water system, the wire-mesh screens are installed between the nozzle-to-heater surfaces. When the wire-mesh screens are not employed, this report exhibits the maximum heat transfer and the secondary maximum value at the stagnation point. But in case of using the wire-mesh screens, the transfer coefficient value of maximum heat exists at the stagnation point, and the second maximum value doesn't occur. Therefore, the heat transfer is more improved than 4~6 times that of the mean Nusselt numbers of simple water jet system, Also, within the region presented in this study, the heat transfer was promoted by using the wire-mesh screens at the stagnation point ; thus, the heat transfer was more increased than 6-7. 5 times that of simple water jet system.

  • PDF

Research on the Actual Condition of Intensifying Screens (증감지감도(增減紙感度)의 실태(實態)에 대한 조사(調査))

  • Huh, Joon;Kim, Chang-Kyun;Kang, Hong-Seok;Kim, Sung-Hoon;Yoon, Han-Sik;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.5 no.1
    • /
    • pp.45-47
    • /
    • 1982
  • Authors carried out the research on the actual condition of intensifying screens in a certain hospital and obtained the results as follows: 1. High speed intensifying screens were 63.9% and medium typed screen had 36.1%. 2. Half the number of using screens(51.5%) were not clear in a period of used time. 3. 47.4% of same typed screens showed a remarkable difference(two times) in sensitivity.

  • PDF

Heat Transfer Augmenttaion by use of Wire Mesh-Screens in Impinging Water Jet (와이어 망을 이용한 충돌 수분류의 열전달 증진)

  • Yun, S.H.;Lee, J.S.;Choi, G.G.
    • Solar Energy
    • /
    • v.19 no.3
    • /
    • pp.43-51
    • /
    • 1999
  • Axisymmetric circular water jet impinges against rectangular heated surface with uniform hear flux and wire-mesh screens are set up in the nozzle-to-heater space to augment heat transfer. In the free jet region to be used them, pressure drop and intensive turbulence flow was brought up. When water jet system is not used wire-mesh screens, maximum heat transfer appears in the stagnation point and the secondary maximum appears X/D=4 but it disappears when they are is used. In the low velocity(Vo<6.0m/s), coarse mesh-screen enhanced heat transfer but fine mesh-screens inpeded heat transfer. In the high velocity(Vo>6m/s), all of them enhanced heat transfer. Average Nusselt number of experimental system to be used wire-mesh screens was promoted $4{\sim}6$times than that of simple water jet system. The stagnation heat transfer of experimental system to be used wire-mesh screens was augmented 6times that of simple water jet system.

  • PDF

A Study on Business-Based Screen Design Techniques for Designing Efficient Applications

  • Kim, Tae-Woo;Park, Sun-Yi;Yeo, Jeong-Mo
    • Journal of Information Processing Systems
    • /
    • v.14 no.6
    • /
    • pp.1420-1430
    • /
    • 2018
  • To build a successful information system, design and development should be carried out from the enterprise perspective. A complicated business is represented in various ways as technology advances, and many development methodologies have been studied from the viewpoint of technology and development. Each domain is independently designed and developed from the enterprise perspective, but there would be inclusive parts due to the integrated process wherein the definition, design, and development of business are carried out, and the design is done based on the designer's experience. This study would like to address the technique of designing screens based on the business process of the applications derived from the business. It designs the screens that appear when actual applications are completed, including how the data transfer process in the derived business process is represented and operated on the relevant screens. It designs the screen which is displayed when the actual application is completed and how the data transfer process in the derived business process is represented and operated on the relevant screen. In addition, it designs the DFD representing the overall flow of data for each business to represent the movement procedure between screens in general. Through the design method proposed in this study, the client's requirement could be confirmed to reduce the cost for redevelopment, the problem of communication between designers and developers with various experiences could be reduced, and an efficient design procedure could be provided to persons who lack design experience.

An Examination of an Efficient UI of Smartphone Home Screen Structure (스마트폰의 홈 화면구조에 따른 효율적 UI 방안 모색)

  • Choi, Jinhae
    • Journal of the Ergonomics Society of Korea
    • /
    • v.36 no.5
    • /
    • pp.437-446
    • /
    • 2017
  • Objective: This study aims to draw an efficient UI design by comparing the usability of App drawer and single-layered home screens, which are smartphone home screens. Background: Because smartphone home screen is frequently used including the installation, deletion, and editing of APPs, it should be designed with easily controllable information structure. There is a need to seek a user-friendly UI by comparing the usability of App drawer and single-layered home screens, of which methods to search Apps are different. There is also a need to examine an efficient UI and the factors to improve from the user perspective. Method: This study targeted 30 Android OS and iOS users to evaluate the App drawer and single-layered home screens, of which UI structures are different. Each participant was instructed to carry out an App searching task and App deleting task, and the execution time and the number of errors were measured. After the tasks were completed, they evaluated satisfaction through a questionnaire survey. Results: In the App searching task with low task level, there was no difference in execution level between the App drawer and single-layered home screens. However, the single-layered home screen showed higher efficiency and accuracy in the App deleting task with high task level. As for the group difference according to use experience, there was no difference in satisfaction among Android OS users, but iOS user satisfaction with single-layered home screen with which they were familiar was higher. Conclusion: As for home screen usability, the single-layered home screen UI structure can be advantageous, as task level is higher. Repulsion was higher, when users, who had used easier UI, used complex UI in comparison with user satisfaction, when users familiar with complex UI used easier UI. A UI indicating the current status with clear label marking through a task flow chart-based analysis, and a UI in which a user can immediately recognize by exposing hidden functions to the first depth were revealed as things to improve. Application: The results of this study are expected to be used as reference data in designing smartphone home screens. Especially, when iOS users use Android OS, the results are presumed to contribute to the reduction of predicted barriers.