• Title/Summary/Keyword: Screen Test

Search Result 632, Processing Time 0.03 seconds

Cost Effectiveness of Interventions to Promote Screening for Colorectal Cancer: A Randomized Trial

  • Misra, Swati;Lairson, David R.;Chan, Wenyaw;Chang, Yu-Chia;Bartholomew, L. Kay;Greisinger, Anthony;Mcqueen, Amy;Vernon, Sally W.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.44 no.3
    • /
    • pp.101-110
    • /
    • 2011
  • Objectives: Screening for colorectal cancer is considered cost effective, but is underutilized in the U.S. Information on the efficiency of "tailored interventions" to promote colorectal cancer screening in primary care settings is limited. The paper reports the results of a cost effectiveness analysis that compared a survey-only control group to a Centers for Disease Control (CDC) web-based intervention (screen for life) and to a tailored interactive computer-based intervention. Methods: A randomized controlled trial of people 50 and over, was conducted to test the interventions. The sample was 1224 partcipants 50-70 years of age, recruited from Kelsey-Seybold Clinic, a large multi-specialty clinic in Houston, Texas. Screening status was obtained by medical chart review after a 12-month follow-up period. An "intention to treat" analysis and micro costing from the patient and provider perspectives were used to estimate the costs and effects. Analysis of statistical uncertainty was conducted using nonparametric bootstrapping. Results: The estimated cost of implementing the web-based intervention was $40 per person and the cost of the tailored intervention was $45 per person. The additional cost per person screened for the web-based intervention compared to no intervention was $2602 and the tailored intervention was no more effective than the web-based strategy. Conclusions: The tailored intervention was less cost-effective than the web-based intervention for colorectal cancer screening promotion. The web-based intervention was less cost-effective than previous studies of in-reach colorectal cancer screening promotion. Researchers need to continue developing and evaluating the effectiveness and costeffectiveness of interventions to increase colorectal cancer screening.

Variation in Susceptibility of Pine Species Seedlings with the Pine Wood Nematode, Bursaphelenchus xylophilus, in Greenhouse

  • Woo, Kwan-Soo;Kim, Yeong-Sik;Koo, Yeong-Bon;Yeo, Jin-Kie;Moon, Yil-Soong
    • The Plant Pathology Journal
    • /
    • v.23 no.2
    • /
    • pp.70-75
    • /
    • 2007
  • We conducted an inoculation test using nine open-pollinated families of pine trees to evaluate their susceptibility and mortality in different densities of pine wood nematode. Three-year-old nine open-pollinated pine families were inoculated with Bursaphelenchus xylophilus at levels of 3,000, 5,000, and 7,000 nematodes/seedling in greenhouse. There were no distinct patterns in latent period among three densities of B. xylophilus in all families. Most families showed the first disease symptoms of needle discoloration within 12-15 days after inoculation. However, open-pollinated progenies of Pinus densiflora showed the longest latent period because none of one-year-old needles were wilted until 14 days after inoculation with 5,000 and 7,000 nematodes. One-year-old needles were wilted earlier than current needles in all tested families with all densities of B. xylophilus. Current needles were not wilted until 14 days after inoculation in all seedlings. The mortality of all seedlings rapidly increased from 35 days to 49 days after inoculation, and all died within 80 days except two seedlings. A 3,000 nematodes/100 ${\mu}L$ with sterilized distilled water are enough to screen 3-year-old pine seedlings for resistance to B. xylophilus.

Elastic Modulus Measurement of a Large Size Digital TV Display Unit (대형 Digital TV용 Display Unit의 강성 측정)

  • Kim Chang-Hoi;Moon Seong-In;Choi Jae-Boons;Kim Young-Jin;Lee Jeoung-Gwen;Koo Ja-Choon
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.3 s.168
    • /
    • pp.115-122
    • /
    • 2005
  • As the digital TV markets rapidly growing, many manufacturers introduce large size flat screen TV units. There are two different display types available to large size models which are plasma and TFT-LCD. Since both are constructed with thin large panels that are mostly fragile to even moderate mechanical shock inputs. Some large size panels are severely resonated by the acoustic sound generated TV which deteriorates video quality. Recognizing the potential problems of large displays, accurate measurement of the panels is to be an essential task for the reliable design. Measurement of mechanical properties of a thin large crystallized panel such as TFT-LCD display with traditional material testing equipments is challenging. Since TFT-LCDs are constructed with combination of brittle glass panels, polymer sheets, and liquid crystal, their properties are not only anisotropic but also usually non-linear. Accurate measurement of the properties often requires very expensive facilities. Especially when the size of the test sample is as large as 40-inch or wider, direct measurement cost is prohibitive. Even worse, machining of the large TFT-LCD to make a smaller size specimen that could be fit into a material tester is not possible because of liquid crystal leakage. A new method fer the measurement of elastic modulus of large TFT-LCD panel is presented in this article. The suggested method provides a simple, economic, and user-friendly way fer measuring the elastic modulus of large panels with considerable level of accuracy.

Development of Railway Platform Safety Equipment using Laser Radar Sensor (레이저 레이더 센서를 이용한 철도 승강장 안전설비의 개발)

  • Kim, Yoo-Ho;Hwang, Jong-Gyu;Jo, Hyun-Jeong;Baek, Jong-Hyun;Kim, Baek-Hyun;Ko, Tae-Kuk
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.2
    • /
    • pp.57-64
    • /
    • 2013
  • Many accidents are being occurred due to many missteps, etc. at the railway platform. Recently in Korea, efforts to prevent casualties fundamentally are being made by installing and operating the PSD(Platform Screen Door) with underground station building as its center to prevent these casualties of passengers. Although this PSD can solve the problem of public casualties at platform fundamentally, it is impossible to install it at whole station buildings since its installation cost is high, and in case of the ground station building of general railway whose operation speed is higher, installation of PSD is impossible due to the characteristics of railway system. This paper proposes the novel safety equipment using Laser radar sensors for the prevention against casualties of passengers at station buildings where the PSDs are not installed like this. The safety equipment using Laser radar sensors is the safety equipment making an approaching train stopped if the falling object is a person by detecting the obstacle at platform through, and it has the merit possible to apply it to station buildings not only in the underground section but also in the ground section since it may detect accurately under ambient environmental elements such as the snow, rain and yellow dust, etc. also. We developed the prototype of the safety equipment to reduce public casualties at platform by using Laser radar sensors and carried out its performance test, and the result is presented in this paper.

Gas Sensing Characteristics and Preparation of SnO2 Nano Powders (SnO2 나노 분말의 합성 및 가스 감응 특성)

  • Lee, Ji-Young;Yu, Yoon-Sic;Yu, Il
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.24 no.7
    • /
    • pp.589-593
    • /
    • 2011
  • [ $SnO_2$ ]nano powders were prepared by solution reduction method using tin chloride($SnCl_2{\cdot}2H_2O$), hydrazine($N_2H_4$) and NaOH. The $SnO_2$ thick films for gas sensors were fabricated by screen printing method on alumina substrates and annealed at $300^{\circ}C$ in air, respectively. XRD patterns of the $SnO_2$ nano powders showed the tetragonal structure with (110) dominant orientation. The particle size of $SnO_2$ nano powders at the ratio of $SnCl_2:N_2H_4$+NaOH= 1:6 was about 60 nm. The sensing characteristics were investigated by measuring the electrical resistance of each sensor in a test box. Sensitivity of $SnO_2$ gas sensor to 5 ppm $CH_4$gas and 5 ppm $CH_3CH_2CH_3$ gas was investigated for various $SnCl_2:N_2H_4$+NaOH proportion. The highest sensitivity to $CH_4$ gas and $CH_3CH_2CH_3$ gas of $SnO_2$ sensors was observed at the $SnCl_2:N_2H_4$+NaOH= 1:8 and $SnCl_2:N_2H_4$+NaOH= 1:6, respectively. Response and recovery times of $SnO_2$ gas sensors prepared by $SnCl_2:N_2H_4$+NaOH= 1:6 was about 40 s and 30 s, respectively.

Evaluation of ROC Curve in High Kilovoltage Technique Using Simulated Nodules on Chest (고관전압 흉부촬영의 가상결절을 이용한 ROC평가)

  • Ahn, Jin-Shin;Chang, Myung-Mi;Chung, Kyung-Mo;Cheung, Hwan;Lim, Jung-Ki;Kim, Jong-Hyo
    • Journal of radiological science and technology
    • /
    • v.15 no.2
    • /
    • pp.25-30
    • /
    • 1992
  • With transmitted dose through chest which has the problem of wide variations in absorption, simple film/screen combination method makes it diffucult to image lung field, mediastinum and retrocardiac areas. In order to overcome this, it is very common to use the high kilovoltage technique in diminishing the differences between high and low contrast. We have been adopting this method at department of diagnostic radiology, Seoul National University Hospital. To compare the image of it with that of low kilovoltage technique, we did radiographic tests using beans on the skin. We marked off into three anatomical categories such as lungs, mediastinum and near diaphragm, then attached a bean on a marked area at random. In order to compare with high and low, we took a radiography of high($120{\sim}140\;kVp$) and low($70{\sim}90\;kVp$) kilovoltage tehchniques, respectively at the same time. We have done experiments 320 cases. We evaluated the results of test in response to sensitivity(true positive) and specificity(true negative). In evaluating, we gave them points from 1 to 5 according to true or false. With given points by a radiologist having much experiences, we could acquire the percentage of sensitivity and specificity. The percentage made us to get the schematic table of ROC curve of those two methods. Consequently, high kilovoltage technique appeared 18% better than low kilovoltage technique for detecting beans with our apparatus.

  • PDF

A study on the brazed bonding of alumina ceramic to aluminum in the air atmosphere (알루미나($Al_2O_3$)세라믹과 알루미늄(A1050)과의 대기중 브레이징 접합에 관한 연구)

  • 최영국;박성현;김윤해;김영식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.19 no.3
    • /
    • pp.50-61
    • /
    • 1995
  • In recent years, many ceramic researchers have discoved various methods of joining ceramic to metal. However, most of these joining methods are perfomed under vacuum and pressured circumstances. So, when we join ceramic to metal,the proceedings are very complicated and require a very high cost. The purpose of this study is to develop a new joining method of an alumina ceramic to an aluminum metal in air atmosphere. The joining condition, such as copper metallizing, nickel plating, brazing, etc. was investigated through the shear strength test of the trial joint. The results obtained from the above experimenta are summarized as follows : 1) In the case of the $Al_2O_3$/$Al_2O_3$joint, the shear strength of the joint was affected by the various foctor such as kaolin content, copper metallizing thickness, firing temperature, firing time. 2) The better shear strength of the $Al_2O_3$/Al joint was obtained when Ni plating was conducted under higher current density than existing plating condition. 3) The shear strength of the $Al_2O_3$/Al joint increases with the Ni plating thickness is confined to the range of this paper. 4) The shear strength of the thermal-shocked specimen($Al_2O_3$/Al joint) was far more deteriorated than that of the as-bonded specimen.

  • PDF

Studies on the Population of Toxigenic Fungi in Dried-Persimmon -Screen test of Aflatoxin- (저장건시 중의 유독성 곰팡이에 관한 연구 -Aflatoxin 유무의 검색에 관하여-)

  • 주현규;권우건
    • Microbiology and Biotechnology Letters
    • /
    • v.8 no.4
    • /
    • pp.237-245
    • /
    • 1980
  • Microorganisms growing on Dried-Persimmon have heed isolated ana identified. Fluorescent substance were extracted from a putrefactive Dried-Persimmon after invaded Toxigenic Fungi, and compared with Aflatoxin by Thin layer chromatography and u. v. absorption spectra. The results obtained were summarized as follows: 1) Fungal invasion was frequently appeared at the beginning of storage, and after then Bacteria invasion was followed. 2) Several Genera of microorganisms (Aspergillus sp., Escherichia sp., Mucor sp., Alternaria sp., Penicillium sp. ) were observed in Dried-persimmon during storage. Aspergillus sp., one of all Genus was predominant. 3) Two strains (Aspergillus flavus Group, Penicillium citrimum Series) of 6 Fungi had Fluorescent substance, which was presumed Aflatoxin-like substance. 4) The Rf value of T. L. C. ana λ max of u. v. absorption spectra showed the same value as the standard of Aflatoxin. It is suppose that the Fluorescent substance in Dried-Persimmon is a Aflatoxin-like substance.

  • PDF

PM Reduction Characteristics of Partial Metal DPF with Screen Mesh Filter Structure (스크린 필터 구조 Partial Metal DPF의 PM 저감 특성)

  • Kim, Chunghui;Kim, Hyunchul;Lee, Geesoo;Choi, Jeonghwang;Chon, Munsoo;Shin, Suk Shin;Suh, Hyun Kyu
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.21 no.3
    • /
    • pp.82-87
    • /
    • 2013
  • In this work, the 1L grade integrated metal DOC/DPF filter that can install in engine manifold position was developed to investigate the effect of platinum-coating amount of filter on the improvement of filter activation temperature and reduction of particulate matter (PM). This filter was installed in 2.9L CI engine which meets the EURO-4 emission regulation. Tests for PM reduction efficiency of filter were conducted under ND-13 mode with full-load test condition. It was revealed that the time to reach the activation temperature of metal filter ($280^{\circ}C$) was shorter as the amount of platinum-coating increased. This short activation time can be helpful for the reduction of CO and HC emissions during cold start condition. At the same time, PM reduced as the coating amount increased. The reduction percentage of $DOC_{40}$, $DOC_{20}$, and $DOC_0$ were 96.7% (2.34 mg/kW'h), 95.1% (3.47 mg/kW'h), and 94.5% (3.69 mg/kW'h) compared to previous result (71.4 mg/kW'h), respectively.

Psychometric Properties of the Korean version of the PTSD Checklist-5 in Elderly Korean Veterans of the Vietnam War (월남전 참전 노인에서 한글판 외상후 스트레스 장애 체크리스트-5의 정신측정학적 특성)

  • Kim, Jong Won;Chung, Hae Gyung;Choi, Jin Hee;So, Hyung Seok;Kang, Suk-Hoon;Kim, Dong Soo;Moon, Jung Yoon;Kim, Tae Yong
    • Anxiety and mood
    • /
    • v.13 no.2
    • /
    • pp.123-131
    • /
    • 2017
  • Objective : The PTSD Checklist (PCL) is a self-report screen for posttraumatic stress disorder (PTSD) that can be scored for both diagnostic assessment and symptom severity measurement. The most recent revision of the Diagnostic and Statistical Manual of Mental Disorders (DSM-5) contains a number of changes to the definition of PTSD, and the aim of this study was to assess the psychometric properties of the Korean version of the PCL for the DSM-5 (PCL-5-K). Methods : The participants were 204 Korean veterans of the Vietnam War who completed the PCL-5-K, the Mini Mental Status Examination (MMSE), PTSD module of Structured Clinical Interview for DSM-5, Research Version (SCID5-RV PTSD module), Korean version of Impact of Event Scale-Revised (IES-R-K) and Combat Exposure Scale (CES-K). Results : The PCL-5-K demonstrated good internal consistency (${\alpha}=0.972$) and test-retest reliability (r=0.96); the suggested cut-off score for PTSD diagnosis was ${\geq}37$ with 0.88 sensitivity and 0.96 specificity. The PCL-5-K scale correlated highly with the IES-R-K and CES-K. Factor analysis identified only one factor. Conclusion : Among elderly Korean veterans of the Vietnam War, the PCL-5-K demonstrated similar psychometric qualities to those of both the original PCL and subsequent versions. It is expected that the PCL-5-K will be a useful PTSD screening tool.