• Title/Summary/Keyword: School area

Search Result 14,068, Processing Time 0.044 seconds

A Study on the Floor Area Characteristics of the University School Building Facilities by the Campus Characteristics in 2001-2003 (캠퍼스 특성별 대학교사시설의 면적특성 - 2001년$\sim$2003년의 기간을 중심으로 -)

  • Kim, Jong-Seok
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.13 no.3
    • /
    • pp.48-55
    • /
    • 2006
  • This paper considered the situation of the school building facilities in the university classified by the campus characteristics. Data were collected from 224 universities campus of 180 4 year colleges. The results are as follows: 1) The floor area of school building facilities increases continuously in 2001-2003 in the campuses studied. The floor area of school building facilities per 1 student increase $15.85m^2$ in 2001, $17.62m^2$ in 2002, and $17.79m^2$ in 2003. 2) The floor area of school building facilities is distributed widely, also the floor area of school building facilities is below $130,000m^2$ and the floor area per 1 student is below $23m^2$ in 75% of the campuses studied. 3) The floor area of school building facilities per 1 student increases $16.07m^2$ in 2001, $17.41m^2$ in 2002 and $17.62m^2$ in 2003. 4) The floor area of school building facilities per 1 student is large but tends to decrease every year in the university of education. Medical, arts and physical type campus has the large floor area per 1 student and the distribution of area is wide owing to the campus having a hospital. The floor area per 1 student is large and the distribution of area is wide in the sub campus.

A study on the Analysis of Space for School Foodservice Facilities - Focus on Elementary and Secondary Schools in the Metropolitan area Since 2009 - (학교 급식시설의 공간 분석 연구 - 2009년 이후 개교한 수도권 초·중·고등학교를 중심으로 -)

  • Seo, Boong-Kyo
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.23 no.5
    • /
    • pp.3-10
    • /
    • 2016
  • The purpose of this study is to provide a basis for planning of school foodservice facilities to operate with hygiene and efficiency corresponding a decrease of the number of students. This study analyzes the composition of space for foodservice facilities categorizing by the functions which are preparation area, cooking area, cleaning area, storage, and worker's room on elementary, middle and high school in Seoul Metropolitan city since 2009 that the Seoul School Health Promotion Center published a manual for school foodservice facilities. The calculation can be a basis for school planners and the general schools to use available area in each school and can manage the school usage plan appropriately. The number of students in each school has been regarded as the space planning element, but the number of students would considered with using the specific area and time.

A Comparative Study on Dietary Life and Associated Factors of School Children and Adolescents between Urban and Rural Area (학동기 아동과 청소년의 도시와 농촌 지역 간 식생활 및 관련 요인 비교 분석)

  • Yi, Bo-Sook;Cho, Kyung-Ryun
    • The Korean Journal of Food And Nutrition
    • /
    • v.19 no.4
    • /
    • pp.502-514
    • /
    • 2006
  • This Study was carried out to find out regional differences about dietary life and factors associated with meal of school children and adolescents between urban and rural area. Forty students from each of the nationwide 51 schools of three different levels(elementary, middle and high school) were surveyed by self-developed questionnaires. Total of 1,886 questionnaires (1,243 from urban and 681 from rural) were collected and distribution of subjects was 544 from elementary school, 661 from middle school, and 681 from high school. The results were summarized as follows. BMI and degree of satisfaction on body weight of elementary and middle school subjects were not significantly different between urban and rural area. But there were significant regional differences in $BMI(urban\;21.2{\pm}3.0,\;rural\;20.5{\pm}2.8,\;p<0.05)$ and degree of satisfaction on body weight of high school subjects(p<0.001). Elementary(p<0.01) and middle school(p<0.05) subjects in urban area had exercised more frequently than those in rural area. Regularity of having breakfast was not significantly different between urban and rural area at each of three different levels of school. Most subjects(urban 92.2%, rural 92.1%) had lunch regularly by virtue of school lunch service. Regularity of having dinner of elementary(p<0.01) and high school subjects (p<0.01) was significantly different between urban and rural area. Reason for skipping dinner of high school subjects was significantly different between urban and rural area (p<0.05). The most delicious meal was dinner for 51.8% of the urban high school subjects and lunch for 51.7% of the rural subjects. Only one third had intention of participating in school breakfast program regardless of region and levels of school. The findings suggested that nutrition education programs for school children and adolescents include different strategy according to region and levels of schools.

A Study on the Kind of Space and the Composition of Area in Elementary School - In Priority on Analyzing the Plan of Each School - (초등학교의 공간종류 및 면적구성에 관한 연구 - 각 학교의 평면분석을 중심으로 -)

  • Rieu, Ho-Seoup
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.4 no.4
    • /
    • pp.5-15
    • /
    • 1997
  • The purpose of this study is to analyze the plan type of school building, the present situation of the kind of room, and of the area composition, -the whole area of school building, the area per class, the area for each person, and the rate of the area composition by room- and the latest tendency with the utilization of the plans of 43 elementary schools and to offer the fundamental data on planning elementary school hereafter. The content of this study can be summarized and arranged as follows: 1. In contrast to the past the schools which is recently constructing intend to improve the spacial type and the level of area. 2. Specially, the location and the area of special classrooms, and teacher's spases is to be improved urgently in almost elementary schools. 3. Because even in the school with same number of classrooms, it is proved that there is the difference of the area by space in accordance with the type of plane, hereafter it is requested to investigate the efficient plane design. 4. Hereafter, it is urgently required to comprehend the practical application of these schools and to research for the space of the school which is compatible with the field of school on the fonduation of the requirement of users.

  • PDF

A Study on the Change of Educational Facility Following Decrease in Population of School Age in Gangwon-do - Focused on the Merger and Abolition of Small School - (강원도내 학령인구 감소에 따른 교육시설 변화에 관한 연구 - 소규모학교 통폐합을 중심으로 -)

  • Kim, Hak Cheol
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.21 no.1
    • /
    • pp.9-16
    • /
    • 2019
  • The decrease in population of school age is one of major influencing factor of transformative educational environment. After the nineteen eighties, the population of South Korea has increased step by step, but the population of school age has been decreasing rapidly by low birth rate. As a result, closed school by merger and abolition of small school occurred all over the country. The closed school needed effective function as center of local community. Consequently the purpose of this study is to provide basic data for effective policy making of closed school by comparative analysis of educational environment such as number of students, schools, students per class, status of usage of closed school of the east area and the west area divided by The Tae Baek Mountains in the Gangwon-do, which has the least students in the nationwide. The results of this study are summarized as follows: 1) Gangwon-do has high decreasing rate of population, schools and students compared with other provinces. However it has significantly low number of students per class. 2) The number of students, schools of the west area in Gangwon-do outnumbers that of the east area. However the number of students per class of the east area in Gangwon-do lesser than that of the west area.

The Floor Area Characttics of the Elementary School Building Facilities by the District Office of Education in Seoul (서울시 지역교육청별 초등학교 교사시설의 면적특성)

  • Kim, Jong-Seok;Ryu, Ho-Seoup
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.17 no.3
    • /
    • pp.33-40
    • /
    • 2010
  • This paper considered 1) the relation between the number of student and the floor area of the school building facility, 2) the situation and the distribution of the school building facilities area, 3) the position between the district office of education by the school building facilities composition. Data were collected from 529 elementary school in seoul. 1) The number of student is have not an influence on the floor area of the school building facility in the middle school. 2) The floor area of the school building facilities per 1 student of the jungbu district office of education is larger than other the district office of education and distribution of area is wide. 3) As the position between the district office of education by the school building facilities composition is considered by principal component analysis, the maintenance of the need space is late in the gangdong gangseo district office of education, maintenance of support space is late in the gangdong dongbu district office of education, the maintenance of management space is late in the seobu bukbu district office of education.

A Study on the Area Characteristics and Layout Types of the Floor Plan of High School Facilities in Eup and Myeon Districts of Jeju Island (제주도 읍·면지역 고등학교의 평면구성에 따른 영역별 특성 및 배치유형에 관한 연구)

  • Byun, Jung-Hyun;Park, Chul-Min
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.21 no.4
    • /
    • pp.37-44
    • /
    • 2019
  • A reduction in the number of high school students in Eup and Myeon districts is very severe. This issue leads to the problem with educational programs of school and an academic achievement gap. Therefore, the purpose of this study is to analyze the characteristics of areas and layout types of the floor plan of high school facilities in Eup and Myeon districts of Jeju Island where the number of students reduces and to provide a fundamental material for establishing school environments. The floor plan of school facilities was categorized into learning, support, common, and other areas and the characteristics of each area were analyzed. As a result, it was necessary to make spatial and facility improvements in common area and support area. The layout type of each area was classified into centralized type, distributed type, and mixed type, and then each type was analyzed. As a result, the main building had low points of the floor plan for learning area and common area. In order to respond to the number of students, it is required to establish reasonable spatial plan criteria and guidelines under the supervision of Office of Education and furthermore to make an effort to create futuristic educational facilities.

A Survey Study on the Status and Standards of School Area (초.중등학교 교지(校地) 면적 및 관련 기준(基準)에 관한 조사 연구)

  • Lee, Hwa-Ryong;Dong, Jae-Wook
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.17 no.3
    • /
    • pp.3-11
    • /
    • 2010
  • This survey study aims to explore the school area standards for elementary, middle and high schools. Traditionally the school site has been recognized as a space of teaching and learning for students. Though its functions and needs have recently been changing from the areas for physical education and training to for various activities such as recreation, play, communication, informal and social areas etc. Moreover the school site is also a critical component of community life. Many communities have a significant shortfall in the amount of park and open space land available and accessible for use. In this viewpoint the standards of school facilities should develop a comprehensive approach to insure that students and residents are provided the opportunity to engage in appropriate types and amounts of everyday's activities during the school day and after school. In doing so, it surveys the school areas of the existing schools and the new schools built in Dongtan City. Finally, it points out the problems of government's regulation for school facilities and proposes the adequate directions for school area standards. This study would help to plan the optimum size of school area and ground and the reasonable expenditure for school facilities.

A Study on the Estimation of Fish School Abundance Using Sonar Image (소너 화상을 이용한 어군량 추정에 관한 연구)

  • 이유원
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.39 no.2
    • /
    • pp.92-98
    • /
    • 2003
  • The quantification of fish school abundance was carried out by using luminance of pixel on scanning sonar image, and compared with the indices of fish school abundance e.g. school number, school area and weighted school area. The survey was carried out in Funka Bay off southern Hokkaido, Japan using research vessel Ushio-Maru during December 1999. A 180-degree scanning sonar with a frequency of 164kHz was used. The school number was counted both left and right 40-degree radial lines from the center of own vessel mark on a scanning image. The school area was measured approximately as an ellipse from the school length and width. The weighted school area was calculated by multiplying school area and average value of inner pixel luminance. A quantification of pixel luminance was also measured to integrate squared pixel luminance value on these lines. Fish school and school bottom were discriminated by the produced sonar echogram using pixel luminance value on these lines. The relationships between the quantified luminance value and other abundance indices such as school area and weighted school area revealed a good correlation. Therefore, the quantified luminance is a useful method in estimating fish school abundance in the acoustic survey using sonar.

A Study on the Comparison of Space Between the Basic Plan and the Working Plan in School Building (학교건축의 계획설계와 실시설계의 공간 비교 연구)

  • Yoon, Chun-Keun;Kang, Hyeok-Jin
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.6 no.1
    • /
    • pp.49-59
    • /
    • 2007
  • The purpose of this study is to propose the type and size of space which is changed working plan as comparison with basic plan. It has been compared basic plan with working plan of 12 educational facilities which was designed basic plan by a professional research organization of educational facilities. The results of this study are summarized as follows; 1) The gross area of elementary school is decreased a course of working plan. But, the meddle and high school's gross area is increased. 2) It was downed 69.28 percent by the area of classroom at the primary school. At the meddle school, 3rd classroom's area increased by 22.65 percent, while 4th classroom's area down 33.98 percent. In case of high school, the area of 4th classroom and public lecture room increased by each 28.23 and 23.17 percent.

  • PDF