• Title/Summary/Keyword: School Facility Construction

Search Result 205, Processing Time 0.031 seconds

On Studying Utilization From of Children Amusement Facility in the Apartment Housing (아파트 단지내 아동 유희시설의 이용행태에 관한 연구 -전주시 아파트단지를 대상으로 -)

  • 임용민;김홍배
    • Journal of the Korean housing association
    • /
    • v.14 no.6
    • /
    • pp.59-67
    • /
    • 2003
  • The development of science technology and high growth of economy have influenced on the change of living environment and have changed people's way of thinking and behavior. Also, apartments has appeared to solve the shortage of housing in cities. This study has a thorough grasp about problems of juvenile playground in the apartments and comes the following conclusion as a result that all sorts of details for amusement behavior have been analyzed. First, juvenile playground should be harmonized with nature, and needs a construction of amusement place that include fixed amusement facilities. Second, for a constitution of dynamic amusement place, a school playground should be opened in the public and parking lots should be utilized for dynamic amusement place in a different time. Third, juvenile playground should be classified by age, especially infant amusement facilities should be installed where a landscape architecture has placed between buildings. Also a daylight should be shined into the place, under considering the installation of bench for parents and rest space. Fourth, a location of amusement place is needed a careful consideration of the environment and building placement, in addition that suitable distance should be set up for children to come into contact easily. Fifth, insufficient things should be complemented as compared with the standards of foreign amusement facilities and guideline should be suggested for maintenance and management of amusement place.

Optimal Site Selection of Carbon Storage Facility using Satellite Images and GIS (위성영상과 GIS를 활용한 CO2 지중저장 후보지 선정)

  • Hong, Mi-Seon;Sohn, Hong-Gyoo;Jung, Jae-Hoon;Cho, Hyung-Sig;Han, Soo-Hee
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.1
    • /
    • pp.43-49
    • /
    • 2011
  • In the face of growing concern about global warming, increasing attention has been focused on the reduction of carbon dioxide emissions. One method to mitigating the release of carbon dioxide is Carbon Capture and Storage (CCS). CCS includes separation of carbon dioxide from industrial emission in plants, transport to a storage site, and long-term isolation in underground. It is necessary to conduct analyses on optimal site selection, surface monitoring, and additional effects by the construction of CCS facility in Gyeongsang basin, Korea. For the optimal site selection, necessary data; geological map, landcover map, digital elevation model, and slope map, were prepared, and a weighted overlay analysis was performed. Then, surface monitoring was performed using high resolution satellite image. As a result, the candidate region was selected inside Gyeongnam for carbon storage. Finally, the related regulations about CCS facility were collected and analyzed for legal question of selected site.

A Study on Survey Research Design Quality Indicators for the Educational Building - Focused on Teachers, School Personnel and Education Office Supervisor - (학교시설 디자인 품질지표에 대한 설문 연구 - 교사, 학교직원, 교육청담당자를 중심으로 -)

  • Cho, Kyung-Sik;Belyalova, Aigerim
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.25 no.5
    • /
    • pp.3-12
    • /
    • 2018
  • The purpose of this study is to examine the degree of appropriateness of using design quality indicators for the educational building, and complements for design quality indicators. For doing this, each items of the Korean educational building design indicator was validated by teachers, school staff and an education officer. First, School Personnel and Teachers considered indicators for the classroom designed for general subjects as being valid. However, in terms of indicators for the outside space, they thought of them as not being valid. In particular, it seemed that school staff would have a passive attitude toward the open of the school facility for the local society. It is judged that there happens an adverse effect caused by the open of the school facility for the local society in the educational environment of the school. Second, Education Office Supervisors thought that eco-friendly indicators, LED lighting, an outer wall, and widows and doors had a high validity. On the contrary, he viewed the validity of a rainwater retention basin as being low, which was likely because he rarely had expertise on the construction. When it comes to the indicator of technology capability, ultrahigh-speed information network was seen as being valid, and the indicator of economic feasibility had high validity on maintenance and durability. Third, compared to groups of Teachers and School Personnel, the group of education officers presented high validity of indicators. Validity of indicators might be differently showed because different items on indicators were measured. However, it is speculated that Education Office Supervisors mostly acknowledged the validity of indicators. Fourth, a majority of Teachers, School staff, and Education Office Supervisors were favor of the system of the evaluation accreditation for school facilities since it played a guide role in improving the quality of school. In order to settle the system of the evaluation accreditation for school facilities, it is most important that institutions in the local society which are publicly reliable should participate in the phase of designing the system of the evaluation accreditation for school facilities. In sum, overall respondents agreed with the system of the evaluation accreditation for school facilities but were aware that reliable organizations in public would need to take part in planning the system of the evaluation accreditation for school facilities from the beginning.

Behavior Case Study of Temporary Structures during Underground Extension Work by Field Measurement (현장계측을 통한 지하증축공사 중 가설구조물의 거동 사례연구)

  • Kim, Uiseok;Min, Byungchan;Kang, Minkyu;Kim, Dongkwan;Choi, Hangseok
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.8
    • /
    • pp.5-13
    • /
    • 2020
  • During the construction of underground space expansion of old facilities, it is necessary to secure temporary residence space for existing residents as well as noise and vibration issues during construction, and in the case of commercial, industrial, and social use, damage is expected from suspension of the use of facilities. There is a need for a technology that minimizes noise and vibration during underground expansion, enabling the use of existing facilities even during construction. In this study, a practical underground extension model is proposed by analyzing the behavior of the temporary structure and the surrounding ground as a result of measurement at each construction stage for a actual construction site. In order to solve the problems that occurred during construction, the basement slabs were placed in advance after the initial excavation. The measurement results (building inclinometer, crack measurement system, structure inclinometer and surface settlement meter) at the site were reviewed to analyze the behavior of the temporary structure and surrounding ground. As a result, it was confirmed that the inclinometer of the building and the structural inclinometer showed a tendency that the displacement after the slab line was placed was reduced or converged. The placement of basement slabs during underground extension not only relived the noise and vibration problems during construction, but also secured the stability of structures.

A Study on the Optimization of New Renewable Energy Systems in Public-Purpose Facilities (공공용 업무시설의 신재생에너지시스템 최적화 연구)

  • Lee, Yong-Ho;Seo, Sang-Hyun;Cho, Young-Hum;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.95-104
    • /
    • 2013
  • This study set out to devise an optimized system to take into account life cycle cost(LCC) and ton of carbon dioxide($TCO_2$) by applying the weighted coefficient method(WCM) to "public-purpose" facility buildings according to the mandatory 5% and 11% of new renewable energy in total construction costs and anticipated energy consumption, respectively, based on the changes of the public obligation system. (1) System installation capacity is applied within the same new renewable energy facility investment according to the mandatory 5% of new renewable energy in total construction costs. Both LCC and $TCO_2$ recorded in the descending order of geothermal, solar, and photovoltaic energy. The geothermal energy systems tended to exhibit an excellent performance with the increasing installation capacity percentage. (2) Optimal systems include the geothermal energy(100%) system in the category of single systems, the solar energy(12%)+geothermal energy(88%) system in the category of 2-combined systems, and the photovoltaic energy(12%)+solar energy(12%)+geothermal energy(76%) system and the photovoltaic energy(12%)+solar energy(25%)+geothermal energy(63%) system in the category of 3-combined systems. (3) LCC was the highest in the descending order of photovoltaic, geothermal and solar energy due to the influences of each energy source's correction coefficient according to the mandatory 11% of new renewable energy in anticipated energy consumption. The greater installation capacity percentage photovoltaic energy had, the more excellent tendency was observed. $TCO_2$ recorded in the descending order of geothermal, photovoltaic and solar energy with the decreasing installation capacity of photovoltaic energy. The greater installation capacity percentage a geothermal energy system had, the more excellent tendency it demonstrated. (4) Optimal systems include the geothermal energy(100%) system in the category of single systems, the photovoltaic energy(62%)+geothermal energy(38%) system in the category of 2-combined systems, and the photovoltaic energy(50%)+solar energy(12%)+geothermal energy(38%) system and the photovoltaic energy(12%)+solar energy(12%)+geothermal energy(76%) system in the category of 3-combined systems.

Measurement of Classroom Air Quality in large cities in summer (여름철 대도심 학교교실의 실내공기환경 측정연구)

  • Kim, Yun-Deok
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.1
    • /
    • pp.63-74
    • /
    • 2007
  • Together with the concern about the indoor all quality as sick house syndrome, the Ministry of Environment announced "Indoor Air Quality Control Law for the Multi Purpose Facility," which made the interests to be focused in the urgent understanding of current condition and preparation of measures about the indoor air pollution. In Dec 2005, the law was revised to obligatorily notify the amount of Formaldehyde and Volatile Organic Compounds in the case of newly constructed apartments with more than 100 houses. School also have its own indoor air quality guideline, Indoor air quality in school is very important because, children who very weak to indoor pollutants reside long time in there. The purpose of this paper is to survey indoor air qualify in school by field measurement. Field measurements were performed in 11 schools which were selected from 3 major cities(Incheon, Dae-jeon, chuncheon) in korea, during July, 2004. Totally concentration of Indoor pollutants were determined in 27 classroom. Target air pollutants were TVOC, formaldehyde, dust, CO, CO2 and NO2. For the result of this investigation, Indoor air quality in classroom was very poor and it was found that some pollutants (TVOC, float bacteria) exceed the guideline.

The Construction of Planning Objectives for School Facilities: An Empiric Case Study in Chunan Chungnam, Korea (학교시설(學校施設) 계획(計劃)의 목표(目標) 설정(設定): 천안(天安)의 경험적(經驗的) 사례(事例) 연구(硏究))

  • Min, Chang-Kee
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.6 no.3
    • /
    • pp.36-46
    • /
    • 1999
  • This paper seeks to show the factors, such as area and building conditions, exterior spatial conditions, and educational equipment, which affect student learning and rest activities in the school facilities. It also develops the order for the factors related to the activities. It collected available data at Shangyoung and Bongsoa Middle Schools in Chunan Chungnam, Korea. Using a t-test and multiple regression analyses, it found the factors affecting activities in different schools. It found that the facility and equipment conditions of the two schools are different. It also found that the planning objectives such as the adaptability of the facilities and equipment, information technology of the equipment, student supervision, and convenience of use of the facilities, in order, are important for planning for new buildings in urban area. And the planning objectives such as the adaptability of the facilities and equipment, the safety of the building, the convenience of use of the facilities, aesthetics, information technology of the equipment, the degree of health benefits are important in order to plan for the renovation of school buildings in urban areas. Thus, it asserts that, considering the planning objectivies developed above, a planner can construct planning objectives for new constuction or renovation of school buildings.

  • PDF

A Case Study of the Improvement of the Structural Work of a Logistics Facility by Using PC Member (PC부재에 의한 물류시설의 골조공사 개선사례 연구)

  • Kim, Seon-Hyung;Choi, Eun-Gyu;Kim, Sun-Kuk;Lee, Sung-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.6
    • /
    • pp.127-135
    • /
    • 2010
  • As logistics facilities have a high ceiling height, simple structure, and the need for a quick return on investment, it is usually essential to advance the construction schedule of such facilities. Accordingly, PC structures, which require less labor, cost and schedule, can be more competitive than RC structures. However, most construction companies in Korea are familiar with RC structure design, have negative perceptions regarding PC structures, and do not sufficiently adopt new construction techniques. The structure that this research features has 110 columns that are 14 m high and are built to the same specification, and applying an RC design to the structure will lead to issues related to constructibility, economic viability, project duration and safety. Therefore, this study intends to feature PC design as an alternative to the RC warehouse design, and perform a comparative analysis of the reduction in labor, cost and construction schedule to highlight benefits. The research outcomes herein will provide inputs to subsequent studies on new construction strategies to advance the construction schedule, improve quality and constructibility, enhance safety and save costs.

Project Schedule Risk Assessment Based on Bayesian Nets (베이지안넷 기반의 프로젝트 일정리스크 평가)

  • Sung, Hongsuk;Park, Chulsoon
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.1
    • /
    • pp.9-16
    • /
    • 2016
  • The project schedule risk in the engineering and facility construction industry is increasingly considered as important management factor because the risks in terms of schedule or deadline may significantly affect the project cost. Especially, the project-based operating companies attempt to find the best estimate of the project completion time for use at their proposals, and therefore, usually have much interest in accurate estimation of the duration of the projects. In general, the management of projects schedule risk is achieved by modeling project schedule with PERT/CPM techniques, and then performing risk assessment with simulation such as Monte-Carlo simulation method. However, since these approaches require the accumulated executional data, which are not usually available in project-based operating company, and, further, they cannot reflect various schedule constraints, which usually are met during the project execution, the project managers have difficulty in preparing for the project risks in advance of their occurrence in the project execution. As these constraints may affect time and cost which role as the crucial evaluation factors to the quality of the project result, they must be identified and described in advance of their occurrence in the project management. This paper proposes a Bayesian Net based methodology for estimating project schedule risk by identifying and enforcing the project risks and its response plan which may occur in storage tank engineering and construction project environment. First, we translated the schedule network with the project risks and its response plan into Bayesian Net. Second, we analyzed the integrated Bayesian Net and suggested an estimate of project schedule risk with simulation approach. Finally, we applied our approach to a storage tank construction project to validate its feasibility.

A Study on the Efficient Bossiness Strategy for BTL Project using Sensitivity Analysis of Financial Model (재무모델 민감도분석을 이용한 BTL사업에 대한 효율적 사업전략에 관한 연구)

  • Kim, Dong-Hun;Lee, Seung-Wook;Kim, Yong-Su
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2008.11a
    • /
    • pp.409-414
    • /
    • 2008
  • The purpose of this study is to analyze the problem of BTL business through the sensitivity analysis of financial model and presented efficiency business strategy when private business owner propose their business. For this, we analyzed the sensitivity of financial model after analyzed costs of the school facility construction case for each place of business. The results of this study are as follows. 1)As the results of the sensitivity of financial model, requirement-earning rate for the results of analysis was decreased average 2.28 points (0.5%) per increasing 0.10% and Construction costs and the maintenance costs were decreased average 10.73 points (2.38%), 6.22 points(1.38%) for increasing 1billion won. 2) The Problem of BTL business according to the sensitivity analysis of financial model was analyzed that the price consultation low investments, and estimation from personal consideration caused it. So, it was analyzed to increase maintenance costs is more efficient method than to increase construction costs.

  • PDF