• Title/Summary/Keyword: School Dust

Search Result 540, Processing Time 0.03 seconds

도시 대기오염의 위해 평가에 있어서 황사효과 분석 -서울시 총사망 및 원인별 사망률에 미치는 영향- (An Analysis of Air Pollution Effect in Urban Area Related to Asian Dust on All-cause and Cause-specific Mortality in Seoul, Korea, 2000-2006)

  • 손지영;조용성;김윤신;이종태;김연정
    • 한국환경보건학회지
    • /
    • 제35권4호
    • /
    • pp.249-258
    • /
    • 2009
  • The objectives of this study were to compare the relative risk of all-cause mortality and cause-specific mortality associated with Asian dust events, and especially to investigate the effects on the susceptible population such as the elderly and children, which were based on the data in Seoul from 2000 to 2006. Both of the study periods with/without Asian dust days, respiratory-cause mortality was the highest, followed by cardiovascular-cause mortality and all-cause mortality in sequence among mortality related to air pollution for all-aged group. As to susceptible group, the relative risk of mortality is the highest for +65 yrs group among all-cause mortality. According to comparison of mortality with/without Asian dust days, the relative risk of all-cause mortality is larger in the model with Asian dust days than the one in the model without Asian dust days among all age group (except for under 15 yrs group) and all air pollutants. The relative risk of cause-specific mortality (except for ozone in under 15 yrs group in case of respiratory-cause mortality, and ozone in all age group and over 65 yrs group in case of cardiovascular-cause mortality) per IQR increase of each pollutant is larger in the model without Asian dust days.

Interaction of Der p 2 with Toll-like Receptor 4 and its Effect on Cytokine Secretion

  • Park, Beom Seok;Lee, Na Rae;Kim, Mun Jeong;Kim, Seong Yeol;Kim, In Sik
    • 대한의생명과학회지
    • /
    • 제21권3호
    • /
    • pp.152-159
    • /
    • 2015
  • Der p 2, which is a major allergen of house dust mite, plays an important role in the pathogenesis of allergic disease. There is controversy regarding whether Der p 2 binds to Toll-like receptor 4 (TLR4), and its inflammatory effect has not yet been elucidated. In the current study, we examined the interaction of Der p 2 with TLR4 and the effect of Der p 2 on cytokine release in THP-1 cells and lymphocytes. Among house dust mite extracts, recombinant TLR4 protein interacted with Der p 2. The overall structure of Der p 2 is characteristic of the immunoglobulin superfamily and contains ten ${\beta}-strands$, forming a ${\beta}-cup$ fold with two anti-parallel ${\beta}-sheets$, and a short 310 helix. The two sheets can be separated, further allowing the formation of a large internal pocket, which is narrow and suitable for binding large flat molecules such as lipid-like molecules. Der p 2 caused increased secretion of IL-6, IL-8, and MCP-1, which are neutrophil survival factors, in human monocytic THP-1 cells in a time-dependent manner. Der p 2 also induces the release of cytokines in normal and allergic lymphocytes. Supernatant after treatment with Der p 2 inhibited neutrophil apoptosis. In coculture of lymphocytes with neutrophils, Der p 2 inhibited spontaneous apoptosis of allergic neutrophils. In summary, Der p 2 binds to TLR4 and induces an inflammatory response such as cytokine secretion in immune cells. These findings may enable elucidation of allergy pathogenesis by specific allergen of house dust mite.

RESIN 취급 주물공장 근로자들의 호흡기 건강에 관한 연구 (Respiratory Health of Foundry Workers Exposed to Binding Resin)

  • 최정근;이창옥;백도명;최병순;신용철;정호근
    • Journal of Preventive Medicine and Public Health
    • /
    • 제27권2호
    • /
    • pp.274-285
    • /
    • 1994
  • The effects of resin on the respiratory health have been investigated in 309 workers from four iron and steel foundries and the results compared with those from 122 workers who were not significantly exposed to resin gas and silica dust at the same industries. Phenol-formaldehyde resin was used in the core making and molding processes and workers were exposed to their decomposition products as well as to silica dust containing particulates. The subjects were grouped according to formaldehyde, dust and other gas exposures, and smoking habits were considered also in thi analysis. Standardized respiratory symptom questionnaire was administered by trained interviewers. Chest radiograph, pulmonary funtion tests, and methacholine challenge tests were done. Environmental measurements at the breathing zone were carried out to determine levels of formaldehyde, respiable dust and total dust. Foundry workers had a higher prevalence of symptoms of chronic bronchitis with chronic phlegm and chronic cough when exposed to dust. Exposure to gas was significantly associated with lowered $FEV_1$ and obstructive pulmonary function changes. Exposure to formaldehyde and phenol gas was associated with wheezing symptom among workers, but $FEV_1$ changes after methacholine challenge were not significantly different among different exposure groups. When asthma was defined as the presence of bronchial hyperreactivity with more than 20% decrease in $FEV_1$ after methacholine challenge, 17 workers out of 222 tested had asthma. Fewer asthmatic welters were found among groups exposed to formaldehyde, gas and dust, which indicates a healthy worker effects ill a cross-sectional study. The concentration of formaldehyde gas ranged from 0.24 to 0.43 ppm among studied foundries. The authors conclude that formaldehyde and phenol gas from combusted resin is probably the cause of asthmatic symptoms and also a selection force of those with higher bronchial reactivity away from exposures.

  • PDF

학교 실험 폐수 처리 방안 (A Study on the Method of Science Laboratory Waste Water by Absorbent at the Secondary School)

  • 장원일
    • 한국환경교육학회지:환경교육
    • /
    • 제2권1호
    • /
    • pp.92-99
    • /
    • 1991
  • According to our secondary school curriculum for natural science and technical circles, there be used 353 of chemical reagents including 24 kinds of harmful and toxicant components. At present, most school are discharging their school laboratory waste water without any chemical and physical treatments. So as to solve the environmental problem for water pollution, this study tried to research a kind of adsorbant utilizing saw dust, wasted wood sources and designed the simple processing system using the adsorbent. This adsorbent was made by extracting lignin substances from raw saw dust under the solution of 0.5N-NaOH at the temperature of $100^{\circ}C$. Their metal removed rates was measured not only by processing of column and vessel. but also by comparing the standard solution and real waste water. The results were proved as more than 90(%) of the adsorptive efficiency on the average from Pb, Cd, Cu except Cr(VI)in case of the school experimental waste water soaked in vessels a long with 4g of the adsorbent for 24 hours. The new processing system enables to remove most harmful and toxicant metals by filtering, sedimenting and adsorbing at the low cost.

  • PDF

Development of Pilot-Scale Scrubber for Simultaneous Removal of $SO_2/NO$

  • Jung, Seung-Ho;Jeong, Gwi-Taek;Lee, Gwang-Yeon;Park, Don-Hee;Cha, Jin-Myeong
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2005년도 생물공학의 동향(XVII)
    • /
    • pp.468-474
    • /
    • 2005
  • SOx and NOx are known major precursors of acid rain and thus the abatement of their emissions is a major target in air pollution control. To obtain basic data on the removal process of simultaneous $SO_2/NO$, the optimal reaction condition and the composition of reaction solution for simultaneous removal of $SO_2/NO$, ware investigated using a bubble column reactor. Pilot scrubber was consisted of scrubber, filter and control box. Dust removal rate was 83, 92, and 97% with catalyst flux of 0.5, 0.8, 1.5 L/min, respectively Average dust removal efficiency with a kind of nozzle was about 94 and 90% in STS FF6.5 (5/8in.) and 14 of P.P W(1.0in.), respectively Dust and $SO_2$ were removed more than 98-96% regardless of reactor number. In the case of NO gas, removal yield of 83.3% was achieved after 48 hours in 1 stage, also removal yield of 95.7% was reached in 2 stages. In tile case of application of STS (5/8 in.) and P.P (1.0 in.) as used fill packing, removal efficiency was reached higher than 98% without related to of kind of fill packing.

  • PDF

발파해체현장에서 발생하는 순간분진의 입경분포 특성 (Characteristics of Particle Size Distributions Generated in the Vicinity of Building Blasting Demolition Sites)

  • 이경희;김효진;박찬규;고광백
    • 한국환경과학회지
    • /
    • 제18권1호
    • /
    • pp.41-47
    • /
    • 2009
  • In building demolition work, major dust-generating activities are blasting concrete and rock. The aim of this study was to find the characteristic of particle size of dusts which were generated during building demolition work using explosion. The DustMate of the Turnkey-Instruments Ltd. was used for particulate size-selective sampling of the four sites. TSP(Total Suspended Particle), PM10(Particle Matter $10{\mu}m$), PM2.5(Particle Matter $2.5{\mu}m$), and PM1.0(Particle Matter $1.0{\mu}m$) were measured during building demolition work using explosion. The large particulate (higher than the diameter $10{\mu}m$) showed to be higher than 50%. The particulate ranged from $10{\mu}m\;to\;2.5{\mu}m$ showed about 30-40%. PM2.5 was not scarcely detected in the samples collected for building demolition work using explosion. We conclude that the dust generated during building demolition work using explosion has not most respirable particulate.

The Distribution Characteristics and Long-term Trend of Carbonaceous Species in Airborne Particulate in Seoul between 1986 and 1996

  • Hwang, Kyung-Chul;Ma, Chang-Jin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • 제19권E1호
    • /
    • pp.11-20
    • /
    • 2003
  • To characterize airborne particulate carbon and its temporal variation in the heavily industrialized metropolitan city, Seoul in South Korea, aerosol sampling was performed from 1986 to 1996. Correlation coefficients of elemental carbon (EC) and organic carbon (OC) with mass concentration of fine particles ($\underline{\leq}$2.1 ${\mu}m$) are 0.73 and 0.51, respectively. EC concentrations of the fine particle mode are 10.1, 5.9, 4.5, and 7.4 ${\mu}g\;m^{-3}$ in winter, spring, summer, and autumn, respectively. On the other hand, OC concentration shows maximum value in winter and followed by autumn, summer, and spring. A seasonal peak in the ratio of OC to EC in fine particles was observed during the summer photochemical season from June to August. Concentrations of EC and OC in Asian dust storm events are generally higher than in non- Asian dust storm events except in 1990. The difference of EC concentrations between Asian dust storm periods and non-Asian dust storm periods are much larger than those of OC concentrations. There are slight increases of EC concentration between 1987 and 1990 and a gradual decrease between 1990 and 1996.

조향장치용 볼 조인트 더스트 커버의 형상최적설계 (Shape optimal design of a dust cover for ball joint of automotive steering system)

  • 이부윤;김지호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제37권6호
    • /
    • pp.603-610
    • /
    • 2013
  • 유한요소해석을 수행하여 조향장치용 타이로드 볼 조인트의 주름 형상 더스트 커버의 응력과 변형을 평가하였다. 조립상태 및 작동상태 하에서 기존 설계안의 더스트 커버를 해석한 결과, 밀봉성이 우수하고 최대응력은 인장강도보다 낮게 나타났다. 더스트 커버의 최대응력을 저감시키기 위하여 형상설계변수를 선정하고, 다구찌 기법을 사용하여 최적형상을 구하였다. 도출된 최적설계안의 작동상태에서의 최대응력은 초기설계안 대비 22 % 감소되는 것으로 나타났다. 본 연구에서 제시된 방법을 사용하면 더스트 커버의 평가 및 설계를 효율적으로 할 수 있다.

장갑공장의 분진발생 억제를 위한 에어젯 노즐의 개발 (Development of a Air-jet Water Sprayer for Dust Generation Control in the Production Sites of Gloves Making Plants)

  • 김진현;최현국;김기동
    • 한국산업융합학회 논문집
    • /
    • 제12권2호
    • /
    • pp.69-78
    • /
    • 2009
  • Dust in the fabric production sites is increased by the static electricity in air which is generated in the manufacturing process. The static electricity is shown in inverse proportion to humidity of the production sites. The optimum humidity rate for the filament in the production process has been established as 65~75%. Where as, average humidity rate of production site is estimated as 40%. Therefore, it is necessary to raise the humidity rate by 30% to maintain appropriate humidity to control generation of static electricity and dust in the production sites. In this study, a new air-jet water sprayer was developed and it can produce $10{\mu}m$ sprayed particles. When the air-jet water sprayer was operated on the production site dust generation rate was shown far below the environmental standard. It is assumed that when the air jet sprayers was applied to 1,000 fabric machines of 5 gloves making plants, its productivity and rates of operation will be improved by value of about 2.5 billion Won a year.

  • PDF

코발트 취급사업장의 공기 중 코발트 노출평가 (Exposure Assessment of Airborne Cobalt in Manufacturing Industries)

  • 김재홍;정종현;피영규
    • 한국산업보건학회지
    • /
    • 제25권2호
    • /
    • pp.166-173
    • /
    • 2015
  • Objectives: The purpose of this study was to evaluate cobalt concentrations in airborne inhalable, total and respirable dust from manufacturing industries using cobalt. Methods: To compare cobalt concentrations, three types of dust samplers(a 37mm closed cassette sampler, Institute of Occupational Medicine(IOM) sampler, and Aluminum cyclone sampler) were used. The analysis of cobalt concentrations was conducted using AAs based on the NIOSH 7300 method. Results: The geometric mean of cobalt concentration in total dust was $1.47{\mu}g/m^3$, and the rate of excess of the Korean Occupational Exposure Limit(KOEL) was 10.0%. The geometric mean concentrations of cobalt in super alloy manufacturing industries were higher than those in plating industries, and molding operations showed higher exposure levels to cobalt than did other operations. Conclusions: The rate of cobalt concentration in inhalable dust from super alloy manufacturing industries exceeding the Workplace Exposure Limit(WEL) as recommended by the Health & Safety Executive(HSE) was 7.1%, which means proper work environmental management is required through wet work environments. Given that molding operations had higher cobalt concentrations, it is necessary to apply measures such as local exhaust for reducing airborne dust in cobalt manufacture industries.