Performance Measurements of Positron Emission Tomography: An Investigation Using General Electric $Advance^{TM}$ (양전자방출단층촬영기의 표준 성능평가 방법: GE $Advance^{TM}$에 적용한 예)

  • Lee, J.R.;Choi, Y.;Choe, Y.S.;Lee, K.H.;Kim, S.E.;Shin, S.A.;Kim, B.T.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.548-559
    • /
    • 1996
  • A series of performance measurements of positron emission tomography (PET) were performed following the recommendations of the Computer and Instrumentation Council of the Society of Nuclear Medicine and the National Electrical Manufacturers Association. We investigated the performance of the General Electric $Advance^{TM}$ PET. The measurements include the basic intrinsic tests of spatial resolution, scatter fraction, sensitivity, and count rate losses and randoms. They also include the tests of the accuracy of corrections: count rate linearity correction, uniformity correction, scatter correction and attenuation correction. GE $Advance^{TM}$ PET has bismuth germanate oxide crystals (4.0mm transaxial ${\times}$ 8.1mm axial ${\times}$ 30.0mm radial) in 18 rings, which form 35 imaging planes spaced by 4.25mm. The system has retractable tungsten septa 1mm thick and 12cm long. Transaxial resolution was 4.92mm FWHM in 2D and 5.14mm FWHM in 3D at the center. Average axial resolution in 2D decreased from 3.91mm FWHM at the center to 6.49mm FWHM at R=20cm. Average scatter fraction of direct and cross slices was 9.57%. Dead-time losses of 50% corresponded to a radioactivity concentration of $4.86{\mu}Ci/cc$ and a true count rate of 519 kcps in 2D. The accuracy of count rate linearity correction was 1.84% at the activity of $4.50{\mu}Ci/cc$. Non-uniformity was 2.06% in 2D and 2.93% in 3D. Remnant errors after scatter correction were 0.55% in 2D and 4.12% in 3D. The errors of attenuation correction were 6.21% (air), 0.20% (water), -6.32% (teflon) in 2D and 5.00% (air), 6.94% (water), 3.01% (teflon) in 3D. The results indicate the performance of GE $Advance^{TM}$ PET scanner to be well suited for clinical and research applications.

  • PDF

Sub-Pixel Analysis of Hyperspectral Image Using Linear Spectral Mixing Model and Convex Geometry Concept

  • Kim, Dae-Sung;Kim, Yong-Il;Lim, Young-Jae
    • Korean Journal of Geomatics
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • In the middle-resolution remote sensing, the Ground Sampled Distance (GSD) that the detector senses and samples is generally larger than the actual size of the objects (or materials) of interest, and so several objects are embedded in a single pixel. In this case, as it is impossible to detect these objects by the conventional spatial-based image processing techniques, it has to be carried out at sub-pixel level through spectral properties. In this paper, we explain the sub-pixel analysis algorithm, also known as the Linear Spectral Mixing (LSM) model, which has been experimented using the Hyperion data. To find Endmembers used as the prior knowledge for LSM model, we applied the concept of the convex geometry on the two-dimensional scatter plot. The Atmospheric Correction and Minimum Noise Fraction techniques are presented for the pre-processing of Hyperion data. As LSM model is the simplest approach in sub-pixel analysis, the results of our experiment is not good. But we intend to say that the sub-pixel analysis shows much more information in comparison with the image classification.

  • PDF

Performance Evaluation of Siemens CTI ECAT EXACT 47 Scanner Using NEMA NU2-2001 (NEMA NU2-2001을 이용한 Siemens CTI ECAT EXACT 47 스캐너의 표준 성능 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.259-267
    • /
    • 2004
  • Purpose: NEMA NU2-2001 was proposed as a new standard for performance evaluation of whole body PET scanners. in this study, system performance of Siemens CTI ECAT EXACT 47 PET scanner including spatial resolution, sensitivity, scatter fraction, and count rate performance in 2D and 3D mode was evaluated using this new standard method. Methods: ECAT EXACT 47 is a BGO crystal based PET scanner and covers an axial field of view (FOV) of 16.2 cm. Retractable septa allow 2D and 3D data acquisition. All the PET data were acquired according to the NEMA NU2-2001 protocols (coincidence window: 12 ns, energy window: $250{\sim}650$ keV). For the spatial resolution measurement, F-18 point source was placed at the center of the axial FOV((a) x=0, and y=1, (b)x=0, and y=10, (c)x=70, and y=0cm) and a position one fourth of the axial FOV from the center ((a) x=0, and y=1, (b)x=0, and y=10, (c)x=10, and y=0cm). In this case, x and y are transaxial horizontal and vertical, and z is the scanner's axial direction. Images were reconstructed using FBP with ramp filter without any post processing. To measure the system sensitivity, NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves were scanned at the center of transaxial FOV and 10 cm offset from the center. Attenuation free values of sensitivity wire estimated by extrapolating data to the zero wall thickness. NEMA scatter phantom with length of 70 cm was filled with F-18 or C-11solution (2D: 2,900 MBq, 3D: 407 MBq), and coincidence count rates wire measured for 7 half-lives to obtain noise equivalent count rate (MECR) and scatter fraction. We confirmed that dead time loss of the last flame were below 1%. Scatter fraction was estimated by averaging the true to background (staffer+random) ratios of last 3 frames in which the fractions of random rate art negligibly small. Results: Axial and transverse resolutions at 1cm offset from the center were 0.62 and 0.66 cm (FBP in 2D and 3D), and 0.67 and 0.69 cm (FBP in 2D and 3D). Axial, transverse radial, and transverse tangential resolutions at 10cm offset from the center were 0.72 and 0.68 cm (FBP in 2D and 3D), 0.63 and 0.66 cm (FBP in 2D and 3D), and 0.72 and 0.66 cm (FBP in 2D and 3D). Sensitivity values were 708.6 (2D), 2931.3 (3D) counts/sec/MBq at the center and 728.7 (2D, 3398.2 (3D) counts/sec/MBq at 10 cm offset from the center. Scatter fractions were 0.19 (2D) and 0.49 (3D). Peak true count rate and NECR were 64.0 kcps at 40.1 kBq/mL and 49.6 kcps at 40.1 kBq/mL in 2D and 53.7 kcps at 4.76 kBq/mL and 26.4 kcps at 4.47 kBq/mL in 3D. Conclusion: Information about the performance of CTI ECAT EXACT 47 PET scanner reported in this study will be useful for the quantitative analysis of data and determination of optimal image acquisition protocols using this widely used scanner for clinical and research purposes.

EFFECT OF COATING COMPOSITION IN DOUBLE COATING ON THE PENETRATION OF FINE PARTICLES INTO SUBSTRATE

  • Kim, Byeong-Soo;Douglas W. Bousfield
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.18 no.1
    • /
    • pp.1-11
    • /
    • 2000
  • The influence of the first coating layer on the properties of the second coating layer is reported. For various model coating composition, ratios of first and second coating weights are used to generate coating layers. The void volume, pore size distribution and light scatter coefficient of the coatings are measured. In some cases, the fine material from the second layer seems to penetrate the first layer to reduce the void fraction of the total system. Rapid setting coating, for example thin layers on porous first layer tends to generate porous coating layers.

  • PDF

A Study on Load distribution Effect for Bridge Structures (교량 구조의 하중분배 효과에 관한 연구)

  • 정철헌;오병환
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1992.10a
    • /
    • pp.234-239
    • /
    • 1992
  • Design live load and girder distribution factors play an important role in the current design procedures. The fraction of vehicle load effect transferred to a single member may be selected in accordance with current KBDC. However, the specified values, both design load and distribution factors involve considerable inaccuracies, These inaccuracies relate to the uncertainties of the structural analysis, especially any bias and scatter which drives from the use of simplified load distribution factors. In this study , based on several field measurement and finite element analysis, live load distribution effects of current KBDC are evaluated. The final values of the bias and coefficient of variation of "g"according to bridge type are determined. The bridge types are reinforced concrete slab, prestressed concrete girder and steel l-beam.el l-beam.

  • PDF

High Spatial Resolution Spectral Mixture analysis for Forest forest Denudation Detection (고해상도 위성영상의 분광혼합분석을 이용한 산림 황폐화 탐지)

  • Yoon Bo-Yeol;Lee Kwang-Jae;Kim Youn-Soo;Kim Yong-Seung
    • Proceedings of the KSRS Conference
    • /
    • 2006.03a
    • /
    • pp.279-282
    • /
    • 2006
  • 분광혼합은 위성영상에서 공간해상도의 한계로 인해 다른 분광 속성을 가진 물질들이 하나의 픽셀 내에 존재하게 될 때 발생하게 된다. 이러한 문제를 해결하고자 분광분리 알고리즘을 통해 픽셀의 순수한 영역만을 선정하여 정확도 높은 탐지가 가능하도록 하는 분광혼합분석(Spectral Mixture Analysis, 이하 SMA)을 고해상도 영상에 적용하였다. 본 연구는 산림의 훼손이 심각한 강원도 정선군 임계지역의 QuickBird 다중분광 위성영상을 이용하였다. 주성분분석(Principal Component Analysis, 이하 PCA)으로 생성된 결과 영상의 1, 2, 3번 밴드를 추출한 후에 밴드간의 Scatter plots 내에서 끝지점에 위치하는 Endmember를 3개(나지, 산림, 초지) 선정하였다. 선정된 Endmember를 토대로 작성된 fraction 영상을 이용하여 강원도 임계지역의 산림훼손으로 초지와 나지로 변화된 지역을 탐지하여 보았다.

  • PDF

A FULLY EMPIRICAL APPROACH TO GALAXY EVOLUTION

  • Renzini, Alvio
    • Publications of The Korean Astronomical Society
    • /
    • v.25 no.3
    • /
    • pp.65-69
    • /
    • 2010
  • Observations of large samples of galaxies from low to high redshifts are composing a picture of remarkable simplicity: (1) The star formation rate (SFR) of starforming galaxies scales almost linearly with mass, strongly decline with cosmic time, and exhibits very small scatter around the average relation. (2) Due to the high observed SFRs the mass of galaxies at high redshifts must increase very rapidly, and yet the mass function of star forming galaxies evolves only very slightly with redshift. (3) At all redshifts the fraction of quenched (passively evolving) galaxies increases with galactic stellar mass and with local overdensity, with the remarkable property that the relative efficiency of "mass quenching" is independent of environment, and that of "environment quenching" is independent of mass. In a recent paper by the zCOSMOS collaboration, Peng et al. (2010) demonstrate that these three empirical facts suffice to account for the observed evolution of the galaxy mass function and naturally generate the "double-Schechter" mass function for quenched galaxies.

8090A1-Li 합금의 공동화에 미치는 응력상태 및 정수압의 영향

  • 오관영;최준환;이동녕;이혁모;이종수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.04a
    • /
    • pp.329-334
    • /
    • 1992
  • It has been shown that the application of hydrostatic pressure during superplastic forming of 8090A1 can prevent the cavitaiton normally encountered at atmospheric pressure and cavity growth rate factor .eta. in the plane strain state is greater than that in the equibiaxial stress state. .eta. value shows some difference compared to the theoretical value, which seems to be due to the continuous nucletion and coalescence of voids during superplastic deformation. Scatter of measured data of cavity volume fraction seems to be on preferential nucleation of viods on non-uniformly distributed second phase particles in the deforming matrix.

Microstructural Evolution Analysis in Thickness Direction of An Oxygen Free Copper Processed by Accumulative Roll-Bonding Using EBSD Measurement (EBSD측정에 의한 반복겹침접합압연된 무산소동의 두께방향으로의 미세조직 변화 분석)

  • Lee, Seong-Hee;Lim, Cha-Yong
    • Korean Journal of Materials Research
    • /
    • v.24 no.11
    • /
    • pp.585-590
    • /
    • 2014
  • Microstructural evolution in the thickness direction of an oxygen free copper processed by accumulative rollbonding (ARB) is investigated by electron back scatter diffraction (EBSD) measurement. For the ARB, two copper alloy sheets 1 mm thick, 30 mm wide and 300 mm long are first degreased and wire-brushed for sound bonding. The sheets are then stacked and roll-bonded by about 50% reduction rolling without lubrication at an ambient temperature. The bonded sheet is then cut to the two pieces of the same dimensions and the same procedure was repeated on the sheets up to eight cycles. The specimen after 1 cycle showed inhomogeneous microstructure in the thickness direction so that the grains near the surface were finer than those near the center. This inhomogeneity decreased with an increasing number of ARB cycles, and the grain sizes of the specimens after 3 cycles were almost identical. In addition, the aspect ratio of the grains decreased with an increasing number of ARB cycles due to the subdivision of the grains by shear deformation. The fraction of grains with high angle grain boundaries also increased with continuing process of the ARB so that it was higher than that of the low angle grain boundaries in specimens after 3 cycles. A discontinuous dynamic recrystallization occurred partially in specimens after 5 cycles.

Characterization of Imaging and Physical Properties in Digital Radiography System (디지탈 X-선 촬영시스템의 영상 및 물리적 특성 분석)

  • Kim, Jong-Hyo;Lee, Tae-Soo;Park, Kwang-Suk;Han, Man-Cheong;Lee, Choong-Woong;Min, Byoung-Goo
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.26 no.7
    • /
    • pp.112-124
    • /
    • 1989
  • In order to evaluate imaging performance of newly developed digital radiography system which requires scanning time as short as 0.7 sec and patient exposure as low as 3 mR, we have investigated its imaging and physical properties such as sensitivity characteristic, scatter fraction, detective quantum efficiency, modulation transfer function, and contrast detail diagram. The results show that the digital radiography system has linear sensitivity to the incident energy, and superior contrast resolving power with less X-ray exposure than conventional film-screen system. These performances are resulted from excellent scatter rejection capability and high detective quantum efficiency of digital radiography system.

  • PDF