• Title/Summary/Keyword: Scan period

Search Result 285, Processing Time 0.029 seconds

Flexible Active-Matrix Electrophoretic Display With Integrated Scan-And Data-Drivers

  • Miyazaki, Atsushi;Kawai, Hideyuki;Miyasaka, Mitsutoshi;Inoue, Satoshi;Shimoda, Tatsuya
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.153-156
    • /
    • 2004
  • A newly developed flexible active-matrix (AM-) electrophoretic display (EPD) is reported. The AM-EPD features: (1) low-temperature polycrystalline silicon (LTPS) thin film transistor (TFT) technology, (2) fully integrated scan- and data-drivers, (3) flexibility and light-weight realized by transferring the whole circuits onto a plastic substrate using $SUFTLA^{TM}$ (Surface Free Technology by Laser Annealing/Ablation) process. A large storage capacitor is formed in each pixel so that driving electric field can be kept sufficiently strong during a writing period Two-phase driving scheme, a reset-phase which erases a previous image and a writing-phase for writing a new image, was chosen to cope with EPD's high driving voltage. The flexible AM-EPD has been successfully operated with a driving voltage of 8.5 V.

  • PDF

Scan Manifestations and Blood Clearance Rates in Typhoid Liver (티프스 간(肝)의 주사(走査)소견과 간혈류 동태)

  • Bahk, Yong-Whee;Ahn, Jae-Sung;Kim, Soon-Hi
    • The Korean Journal of Nuclear Medicine
    • /
    • v.4 no.2
    • /
    • pp.67-71
    • /
    • 1970
  • Fourteen patients with typhoid fever were studied by scanning and clearance-rate measurements of subcritical dose colloidal radiogold($^{198}Au$). Mild to moderate enlargement of the liver and spleen was noted in 78.6 and 64.3 per cent of patients, respectively; and splenic and spinal bone-marrow uptake was seen in 78.6 and 57.1 per cent of cases, respectively. Typically, these scan changes occurred concomitantly (57.1%) and are considered to represent increased phagocytic activity of the RE cells which is characteristic of typhoid fever. The half clearance-time was significantly shortened during the first 10-day period of the illness indicating an increas in the hepatic blood in the early phase of typhoid infection. Hepatomegaly, splenomegaly and extrahepatic uptakes along with an accelerated (or later a normal) clearance time are characteristic of typhoid fever.

  • PDF

Experimental Study on the Keyboard Scanned Algorithm by a Microprocessor-Based Interrupt Control Method (마이크로프로세서 기반 인터럽트 제어방법에 의한 키보드 스캔 알고리즘에 관한 실험적 연구)

  • Lee, young-wook
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2010.05a
    • /
    • pp.272-273
    • /
    • 2010
  • The method of interrupt control is attempted to recognize the button-pushed result from a keyboard scan through control of 30ms appropriate period instead of key scan control method for a microprocessor system. This experimental study shows the reduced processing load of a microprocessor and prevention of the error by an algorithm when the keyboard buttons are both pushed at the same time as we recognize the result of a keyboard scanning by an interrupt method. In addition, an algorithm is provided to recognize the result of scanning by C programming as the keyboard button of a microprocessor system is pushed.

  • PDF

Effect of the Bean Sprouts Growth by Scanning Frequency of Diagnostic Ultrasound Probe Type and Mode Change (진단용 초음파 Probe 및 Mode 변화에 따른 초음파 주사빈도가 콩나물 발아 과정에 미치는 영향)

  • Choi, Kwanyong;Lim, Hyun Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.150-154
    • /
    • 2015
  • Long time ultrasound scan can cause a temperature rise in human tissue and affect the physical body. This is closely connected with patients' safety. So many researchers have been studied on this matter with animals such as mammals and experimental rat, because diagnostic ultrasound has been used many types of human organ to find disease. Therefore, this study is tested on bean sprouts to search how far the tissue temperature changes because of the excessive scanning consequence from ultrasound diagnosis and frequent number of ultrasonic scanning and how much affect their growth. The United States and several European countries have restrictions for number of scanning, while South Korea does not have any limitation for using ultrasound diagnosis. Comparison was that how different condition affect its' growing. The testing group is like many pregnancy moms to have 50 minutes in B-mode and color doppler mode by linear, convex and sector probe every day for a week and the other is to scan only once during the testing period. As a result, it was confirmed that there was a significant growing difference on frequent ultrasonic scanning group compared to normal one. So the final conclusion is that there needs to have a significant limitation of ultrasound scan time and a number of inspection when having for diagnostic ultrasound and recommendation like USA and a few European countries.

Development of an Arachnoid Cyst after Ventriculoperitoneal Shunt Placement - A Case Report - (뇌실복강간 단락술 후 발생한 뇌지주막 낭종 - 증 례 보 고 -)

  • Choi, Kwang Yeong;Rhee, Bong Arm;Lim, Young Jin;Kim, Tae Sung;Kim, Gook Ki;Leem, Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup2
    • /
    • pp.364-367
    • /
    • 2001
  • A 4-month-old female patient admitted because of hydrocephalus. She was premature infant with germinal matrix hemorrhage at gestational period 27 wks. A ventriculoperitoneal shunt with a low-pressure type valve was placed. Follow-up CT scan obtained 3 months after VP shunt placement, revealed a new Lt. middle cranial fossa cyst. The girl was readmitted to hospital at 7 months after VP shunt placement, complaining of lethargy and vomiting. A CT scan was demonstrated a increase in size of a cyst, She subsequently underwent a left-sided pterional craniotomy with partial excision of membrane and cyst fenestration into the basal cisterns. Follow-up CT scan after 18 months revealed reaccumulation of cyst, the girl was reoperated on. After 2 months, the size of cyst was not decreased. Finally, She underwent a cystoperitoneal shunt. Follow-up CT scan after 5 months was demonstrated disappeared cyst and reexpansion of brain parenchyma. We report the development of a symptomatic sylvian fissure arachnoid cyst developed after ventriculoperitoneal shunt.

  • PDF

Improvement of Address Discharge Characteristics Using Wall Charge on Common Electrodes in AC PDP (플라즈마 디스플레이 패널에서 공통전극에서의 벽전하를 이용한 기입방전특성의 향상)

  • Cho, Byung-Gwon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.3
    • /
    • pp.174-178
    • /
    • 2013
  • A modified driving waveform is proposed to improve the address discharge characteristics using wall charge on the common electrodes in plasma display panel. In the driving scheme of plasma display, after a reset period, the negative charge are accumulated on two front electrodes and positive wall charge are accumulated on the address electrode. As the address discharge during an address period is produced when the scan and address pulses are applied at the same time, negative charge on the scan electrodes and positive charge on the address electrodes are mainly used. On the other hand, as the voltage are only maintained without applying the waveform during an address period on the common electrodes, the wall charge is not used on the common electrodes. In this paper, the address discharge characteristics are investigated with changing pulse applying time and applied voltage amplitude on the common electrodes and consequently the producing time of an address discharge are shortened about 200 ns compared with the conventional driving waveform.

A New Address-While-Display Driving Method using the $\underline{S}hort\;\underline{R}amp\;\underline{R}eset$ Pulse (SRR) for High Contrast ratio and Wide Address Margin

  • Jung, Jae-Chul;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.631-634
    • /
    • 2005
  • We propose a new address-while-display (AWD) driving method to obtain a high contrast ratio and a wide driving margin which is composed of a short ramp reset period, a sustain period and an address period as the basic unit. The short ramp reset (SRR) pulse made it possible to assure the wide operating voltage margin and minimize the background luminance by redistributing the wall charges between address and scan electrode. As a result, a high dark room contrast ratio of 10000 to 1 could be obtained with a wide operating voltage margin of 40V for stable address.

  • PDF

Measurement of Effective Half-life Using Dual Time I-131 Whole Body Scan in Patients with Differentiated Thyroid Cancer Treated by High Dose Therapy (고용량 방사성옥소 치료를 받은 갑상선분화암 환자에서 Dual Time I-131 Whole Body Scan을 이용한 유효반감기의 측정)

  • Yoon, Jae Sik;Lee, Jae Gon;Lee, Ki Hyun;Lim, Kwang Seok;Choi, Hak Ki;Lee, Sang Mi
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.98-103
    • /
    • 2014
  • Purpose: The effective half life of I-131 is useful to calculate radiation dose, period of hospitalization, and exposure dose of surrounding people from patient. However, it is difficult to measure. This study estimates the effective half life in whole body and thyroid in using of value of residual radioactivity obtained from the early and delay images of Dual time I-131 whole body scan. Also, the correlations between the effective half life and serum creatinine, GFR, and administration dose were investigated in this study. Materials and Methods: The targets were 50 patients administration high dose of I-131 from February to August in 2013, having normal range of serum creatinine and over $30{\mu}IU/mL$ of TSH levels. After administration radioactive I-131, the early scan in the 3rd day and the delay scan in the 5-6th days were performed. To measure the residual radioactivity in the whole body and thyroid, ROI was set and then background radioactivity was corrected to estimate. The effective half life was estimated by calculating the ratio of measured values between the early and delay images. To compare the effective half lives of the whole body and thyroid, it was analyzed by Independent t-test, and each correlation of the effective half life, GFR, serum creatinine, and the dose of administration were analyzed by calculating the pearson's correlation coefficient. All of the analysis were determined to be statistically significant when P<0.05. Results: The effective half life of the whole body was $17.06{\pm}5.50$ hours and of the thyroid was $17.22{\pm}5.41$ hours. The two effective half life did not show significant difference (P=0.887). As the value of GFR was increased, the effective half life of whole body (r=-0.407, P=0.003) and of thyroid (r=-0.473, P=0.001) were significantly decreased; as the value of serum creatinine was increased, the effective half life of whole body (r=0.309, P=0.029) and of thyroid (r=0.371, P=0.008) were significantly increased. In the administration dose, effective half life did not have correlations. Conclusion: The effective half life of I-131 of patients treated for their thyroids were estimated only by using the images of Dual time I-131 whole body scan. Also, the correlations with the effective life, GFR, and serum creatinine were examined. This study might be utilized for a study on optimization for the period of hospitalization of patients treated by high dose of I-131 and on evaluation for internal absorbed dose of MIRD schema in application of the effective half life.

  • PDF

Real Time Spectroelectrochemical Experiments with a Multichannel Detector

  • Sun-Il Mho;Sally N. Holer;Bum-Soo Kim;Su-Moon Park
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.9
    • /
    • pp.739-743
    • /
    • 1994
  • A spectroelectrochemical system assembled with a white light source, bifurcated optical fiber, Oriel Multispec spectrograph, and a charge-coupled device (CCD) detector is described. The system is shown to be capable of acquiring a whole spectrum in the spectral range of 290-800 nm in 25 ms or a longer period during electrochemical experiments at reflective working electrodes such as platinum or mercury. The utility of the system in studying electrochemical reactions during the potential scan, galvanostatic electrolysis, or after the potential step is demonstrated.

Building the Process for Reducing Whole Body Bone Scan Errors and its Effect (전신 뼈 스캔의 오류 감소를 위한 프로세스 구축과 적용 효과)

  • Kim, Dong Seok;Park, Jang Won;Choi, Jae Min;Shim, Dong Oh;Kim, Ho Seong;Lee, Yeong Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.1
    • /
    • pp.76-82
    • /
    • 2017
  • Purpose Whole body bone scan is one of the most frequently performed in nuclear medicine. Basically, both the anterior and posterior views are acquired simultaneously. Occasionally, it is difficult to distinguish the lesion by only the anterior view and the posterior view. In this case, accurate location of the lesion through SPECT / CT or additional static scan images are important. Therefore, in this study, various improvement activities have been carried out in order to enhance the work capacity of technologists. In this study, we investigate the effect of technologist training and standardized work process processes on bone scan error reduction. Materials and Methods Several systems have been introduced in sequence for the application of new processes. The first is the implementation of education and testing with physicians, the second is the classification of patients who are expected to undergo further scanning, introducing a pre-filtration system that allows technologists to check in advance, and finally, The communication system called NMQA is applied. From January, 2014 to December, 2016, we examined the whole body bone scan patients who visited the Department of Nuclear Medicine, Asan Medical Center, Seoul, Korea Results We investigated errors based on the Bone Scan NMQA sent from January 2014 to December 2016. The number of tests in which NMQA was transmitted over the entire bone scan during the survey period was calculated as a percentage. The annual output is 141 cases in 2014, 88 cases in 2015, and 86 cases in 2016. The rate of NMQA has decreased to 0.88% in 2014, 0.53% in 2015 and 0.45% in 2016. Conclusion The incidence of NMQA has decreased since 2014 when the new process was applied. However, we believe that it will be necessary to accumulate data continuously in the future because of insufficient data until statistically confirming its usefulness. This study confirmed the necessity of standardized work and education to improve the quality of Bone Scan image, and it is thought that update is needed for continuous research and interest in the future.

  • PDF