• 제목/요약/키워드: Scan period

검색결과 285건 처리시간 0.026초

산업용 임의형상제작(Solid Freeform Fabrication)시스템의 공정변수 최적화 (Process Optimization of Industrial Solid Freeform Fabrication System)

  • 곽성조;이두용
    • 대한기계학회논문집A
    • /
    • 제32권7호
    • /
    • pp.602-609
    • /
    • 2008
  • This paper presents experimental optimization of process parameters for a newly developed SFF(Solid Freeform Fabrication) system. Two critical process parameters, layering thickness and curing period, which have a large effect on the quality of the product, are optimized through experiments. Specimens are produced using layering thicknesses of 60, 80, 100, 120, 140, and $160\;{\mu}m$ and curing periods of 0, 10, 20, and 30 minutes under the same processing conditions, i.e., build-room temperature, feed-room temperature, roller speed, laser power, scan speed, and scan spacing. The specimens are tested to compare and analyze performance indices such as thickness accuracy, flatness, stress-strain characteristics, and porosity. The experimental result indicates that layering thickness of $80{\sim}100\;{\mu}m$ and curing period of $20{\sim}30$ minutes are recommended for the developed industrial SFF system.

Modified Ramp Reset Waveform for High Contrast Ratio in AC PDPs

  • Kim, Jae-Sung;Yang, Jin-Ho;Ha, Chang-Hoon;Whang, Ki-Woong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2002년도 International Meeting on Information Display
    • /
    • pp.199-202
    • /
    • 2002
  • In general, the background light produced during the reset period deteriorates the dark room contrast ratio in AC PDP. In this paper, we propose a modified ramp reset pulse that can reduce the background light to imperceptible level. In the new reset waveform, the discharges between the scan and sustain electrodes are minimized by applying a positive bias voltage to the sustain electrode and only the weak discharges between the scan and address electrodes occur during the reset period. We adopted a MgO coated phosphor layer to get the same level of voltage margin in the new reset pulse scheme compared to that of the conventional ramp reset pulse one. As a result, the voltage margin is maintained at the same level and the dark room contrast ratio is improved dramatically.

  • PDF

Azimuth Stitching 없는 ScanSAR 영상화: 시간영역 교차상관 (A ScanSAR Processing without Azimuth Stitching by Time-domain Cross-correlation)

  • 원중선
    • 대한원격탐사학회지
    • /
    • 제38권3호
    • /
    • pp.251-263
    • /
    • 2022
  • 이 논문은 ScanSAR 영상화에 대한 새로운 아이디어를 소개한다. 버스트(Burst) 모드로 신호를 획득하는 ScanSAR의 전통적인 영상화는 버스트 간 영상을 연결하는 Azimuth stitching이 필요하여, 이 과정은 방사왜곡 및 위상왜곡을 유발한다. 전통적인 SPECAN 방법 대신 이 논문에서는 시간영역 교차상관을 이용하여 Azimuth stitching 과정 없이 영상화가 가능한 새로운 방법을 소개한다. 이 방법의 핵심 아이디어는 기준함수 밴드폭을 적절히 확장하여 시간영역 교차상관을 수행하면 Azimuth stitching 없이도 영상화가 가능하다는 점이다. 이 방법을 실제 위성 원시신호에 적용하여 영상 전 구간에서 영상품질과 방사왜곡 관점에서 우수한 성능을 검증하였다. 버스트 모드를 기반으로 하는 ScanSAR는 영상품질(3 dB 해상도, peak-to-sidelobe ratio (PSLR), 압축률, Speckle 잡음 등)은 모든 품질지표에서 도플러 주파수 전 영역 신호를 이용하는 Stripmap에 비해 낮을 수밖에 없다. 그러나, 각 활용분야 및 기술에 따라 선정된 특정 영상 품질지표 만을 개선할 수 있는 방법은 다양하다. 따라서 ScanSAR 영상화는 모든 활용분야에 획일적인 방법에 의한 영상화보다는, 각 활용에 따라 요구되는 품질지표 우선순위에 따라 최적화할 수 있는 영상화 방법을 적용하는 차별화 전략이 요구된다.

골격계진단에 있어서 핀홀스캔의 우월성 (Whether Pinhole Scan or Single Photon Emission Computed Tomography (SPECT) in the Diagnosis of Bone and Joint Diseases)

  • 박용휘
    • 대한핵의학회지
    • /
    • 제30권1호
    • /
    • pp.1-14
    • /
    • 1996
  • Since the publication of the first bone scintiscans in 1962 three decades have elapsed. The bone scan has made great strides during this period, becoming one of the most commonly used nuclear imaging tests. In spite of the progress, however, the specificity of bone scan has remained relatively low. As the result it is a common practice to seek additional information from radiograph, CT scan and MR image, which is euphemistically termed as "image fusion or co-location." The basic reason is the inapplicability of the classical piecemeal analysis to interpreting planar and SPECT bone scans. Such analysis has its base on the observation of elemental features of morphology, which include the size, shape, contour, location, topography and internal architecture. The physiochemical profile may well also be included. Understandably, however, the miniatured images of the planar bone scan cannot provide these features in acceptable detail and the same holds true even with SPECT Images which are but sliced views of the reconstructed planar scans. Fortunately pinhole scanning has the capacity to portray both the morphological and chemical profiles of bone and joint diseases in greater detail through true magnification. The magnitude of pinhole scan resolution is practically comparable to that of radiography as far as gross anatomy is concerned. Thus, we feel strongly that pinhole scanning is a potential breakthrough of the long-lamented low specificity of bone scan. This presentation will discuss the fun-damentals, advantages and disadvantages and the most recent advances of pinhole scanning. It high-lights the actual clinical applications of pinhole scanning in relation to the diagnosis of infective and inflammatory diseases of bone and joint.

  • PDF

원발성 유방암에서 질병병기 분류 및 추적검사 $^{99m}Tc-MDP$ 골 신티그램의 의의 ($^{99m}Tc$ MDP-Bone Scintigraphy for Preoperative and Follow up Assessment in Primary Breast Cancer)

  • 이강욱;방영주;정준기;이명철;조보연;김노경;고창순
    • 대한핵의학회지
    • /
    • 제22권1호
    • /
    • pp.59-64
    • /
    • 1988
  • Because carcinoma of breast is known to readily metastasize to the bone, early detection of metastasis spread is very important. Two hundred thirty four consecutive patients who had $^{99m}Tc-MDP$ bone scans prior to treatment and during the follow up period were studied retrospectively to determine the contribution of the scans to staging, treatment and follow up examination between Jan. 1980 and Apr. 1987 in Seoul National University Hospital. 1) Positive bone scan rates in initial clinical stage I, II, III and IV were 0%, 4%, 14% and 53%, respectively. 2) The higher clinical stage is, the more cumulative risk of conversion to positive bone scan is during the same follow up period. 3) Conversion rate to positive bone scan in patients with lymph node metastasis is higher (50%) than those without metastasis (18%) (P < 0.001). We concluded that the bone scan in primary breast cancer was very useful to evaluate initial clinical stage and to perform the follow up examination.

  • PDF

AC-PDP의 유지방전 전극사이의 간격과 어드레스 방전 특성과의 상관성 분석 (The Analysis of the Correlation between the Sustain-Electrode Gap of an AC-PDP and Address Discharge Characteristics)

  • 이영준;최수삼;박세광;김용득
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권5호
    • /
    • pp.239-244
    • /
    • 2006
  • To drive the high-image quality plasma displays of XGA and/or full-HD, we must effectively improve the driving waveform, which get the reset period for the stabilized control of wall charges, the address period to select discharge or non-discharge, and sustain period for luminance in 1 TV-frame, and also the display quality. To accomplish them, the development of the technology for the fast address discharge is required. In this paper, the correlation between the sustain-electrode gap and address discharge characteristics for the high-speed addressing was analyzed using the measurements of dynamic voltage margins. Results showed that the narrower the gap between the sustain electrodes, the narrower the with of the scan pulse became and a dynamic margin of data voltage of 29.2 V was obtained at scan pulse width of $1.0{\mu}s\;and\;V_{ramp}$ of 240 V for driving 4-inch test penal, which the gap between sustain electrodes was $65{\mu}m$.

골관절염을 가진 측두하악장애 환자의 치료 전, 후 골스캔과 SPECT의 평가 (The Evaluation of Bone Scan and SPECT Before and After Treatment of TMD Patients)

  • 김병수;안용우;고명연;박준상
    • Journal of Oral Medicine and Pain
    • /
    • 제30권1호
    • /
    • pp.57-67
    • /
    • 2005
  • 저자는 2000년 1월부터 2003년 12월까지 부산대학교병원 구강내과에 측두하악관절장애를 주소로 내원한 환자 중 임상검사와 방사선검사를 시행하여 측두하악관절의 골관절염으로 진단되어, 초진 시와 종결 시에 골스캔과 SPECT를 각각 촬영한 환자 27명을 대상으로 골스캔의 SUR 와 SPECT의 온점의 개수를 치료 전, 후로 비교하고 병력, 기여요인, 증상, 치료방법, 치료기간 등을 기준으로 골스캔의 SUR 과 SPECT의 온점의 개수를 비교 연구하여 다음과 같은 결과를 얻었다. 1. 골관절염에 이환된 관절군에서 치료 전 골스캔의 SUR 과 SPECT의 온점의 개수가 골관절염에 이환되지 않은 관절군에 비해 유의하게 높은 소견을 보였다(P<0.05). 2. 골관절염에 이환된 관절에서 치료 전 골스캔의 SUR 과 SPECT 온점의 개수가 보존적 치료 후에 유의하게 감소하였다(P<0.01). 3. 교합장치를 이용해서 치료한 군에서 골스캔의 SUR 과 SPECT 온점의 개수가 치료 후에 유의하게 감소하였다(P<0.01,P<0.05). 4. 만성군에서 치료 전 골스캔의 SUR 과 SPECT의 온점이 치료 후에 유의하게 감소하였다(P<0.05). 5. 관절음에 대한 불편감 정도가 낮은 환자군의 치료 전 골스캔의 SUR과 SPECT의 온점의 개수가 치료 후에 유의하게 감소하였다(P<0.01). 6. 외상 병력이 없고, 악습관이 있고, 정신사회적 배경이 없는 환자일수록 골스캔의 SUR과 SPECT의 온점의 개수가 치료전에 비해 치료후에 현저히 낮았다. 7. 초진 시 골스캔의 SUR과 SPECT의 온점의 개수가 높을수록 많은 치료기간이 필요하다.

2차원 레이저 거리계를 이용한 수직/수평 다각평면 기반의 위치인식 및 3차원 지도제작 (3D Simultaneous Localization and Map Building (SLAM) using a 2D Laser Range Finder based on Vertical/Horizontal Planar Polygons)

  • 이승은;김병국
    • 제어로봇시스템학회논문지
    • /
    • 제20권11호
    • /
    • pp.1153-1163
    • /
    • 2014
  • An efficient 3D SLAM (Simultaneous Localization and Map Building) method is developed for urban building environments using a tilted 2D LRF (Laser Range Finder), in which a 3D map is composed of perpendicular/horizontal planar polygons. While the mobile robot is moving, from the LRF scan distance data in each scan period, line segments on the scan plane are successively extracted. We propose an "expected line segment" concept for matching: to add each of these scan line segments to the most suitable line segment group for each perpendicular/horizontal planar polygon in the 3D map. After performing 2D localization to determine the pose of the mobile robot, we construct updated perpendicular/horizontal infinite planes and then determine their boundaries to obtain the perpendicular/horizontal planar polygons which constitute our 3D map. Finally, the proposed SLAM algorithm is validated via extensive simulations and experiments.

Serious Blood-Brain Barrier Disruption after Coil Embolization of Unruptured Intracranial Aneurysm : Report of Two Cases and Role of Immediate Postembolization CT Scan

  • Lee, Kyung-Kyu;Kang, Dong-Hun;Kim, Yong-Sun;Park, Jae-Chan
    • Journal of Korean Neurosurgical Society
    • /
    • 제50권1호
    • /
    • pp.45-47
    • /
    • 2011
  • Abnormal contrast enhancement on brain computed tomography (CT) scan after diagnostic or interventional angiography is not rare, and has known to be induced by temporary blood-brain barrier (BBB) disruption from contrast media. Furthermore, it has been regarded as clinically subtle, but reported to have no symptom or mild transient symptoms. However, we recently experienced two cases of serious BBB disruption during the acute period after coiling of an unruptured intracranial aneurysm. One patient presented with an unruptured paraclinoid internal carotid artery (ICA) aneurysm on the right and the other with an unruptured right supraclinoid ICA aneurysm. Both patients showed similar findings on immediate postembolization CT scan and clinical courses after coiling. Typical radiological, clinical characteristics of BBB disruption were described. In addition, the role of immediate postembolization CT scan are also discussed.

Lumbar Spine CT 촬영한 요각통 환자 32례의 치료경과 분석 (The Clinical Analysis on 32 Cases of Herniated Lumbar Disc Patients according to Lumbar CT scan.)

  • 김정호;이정환;김영일
    • 대한약침학회지
    • /
    • 제13권2호
    • /
    • pp.111-120
    • /
    • 2010
  • Objective: This study is to evaluate the effectiveness of the oriental medicine treatment on lumbar disc herniation. Subjects and Methods : The clinical analysis was done on 32 cases of patients with lumbar disc herniation diagnosed by lumbar CT scan. Patients who admitted In Cheongju Oriental Medicine Hospital from April 2007 to April 2008 were analyzed according to the distribution of sex, age, the period of disease, condition on admission, the symptom on admission, Admission day, the treatment efficacy at discharge day. Results : 1. The forties was the most, the acutest phase the most, the day of 8-14 days the most. 2. Multiple bulging disc in 37.5% of CT scan was the most common, followed by a single HNP was 28.1%. 3. Almost 81 % patients showed effective efficacy under VAS 3 at discharge day. 4. Single bulging and herniated disc were more short admission days than multiple bulging and herniated disc.