References
- Aspelin P, Aubry P, Fransson SG, Strasser R, Willenbrock R, Berg KJ : Nephrotoxic effects in high-risk patients undergoing angiography. N Engl J Med 348 : 491-499, 2003 https://doi.org/10.1056/NEJMoa021833
- Baik SK, Kim YS, Lee HJ, Park J, Kim GC : Immediate CT findings following embolization of cerebral aneurysms : suggestion of blood-brain barrier or vascular permeability change. Neuroradiology 50 : 259-266, 2008 https://doi.org/10.1007/s00234-007-0332-z
- Brisman JL, Jilani M, McKinney JS : Contrast enhancement hyperdensity after endovascular coiling of intracranial aneurysms. AJNR Am J Neuroradiol 29 : 588-593, 2008 https://doi.org/10.3174/ajnr.A0844
- May EF, Ling GS, Geyer CA, Jabbari B : Contrast agent overdose causing brain retention of contrast, seizures and parkinsonism. Neurology 43 : 836-838, 1993 https://doi.org/10.1212/WNL.43.4.836
- Mentzel HJ, Blume J, Malich A, Fitzek C, Reichenbach JR, Kaiser WA : Cortical blindness after contrast-enhanced CT : complication in a patient with diabetes insipidus. AJNR Am J Neuroradiol 24 : 1114-1116, 2003
- Okazaki H, Tanaka K, Shishido T, Nagase H, Hoshino M, Takebayashi S, et al. : Disruption of the blood-brain barrier caused by nonionic contrast medium used for abdominal angiography : CT demonstration. J Comput Assist Tomogr 13 : 893-895, 1989 https://doi.org/10.1097/00004728-198909000-00027
- Uchiyama Y, Abe T, Hirohata M, Tanaka N, Kojima K, Nishimura H, et al. : Blood brain-barrier disruption of nonionic iodinated contrast medium following coil embolization of a ruptured intracerebral aneurysm. AJNR Am J Neuroradiol 25 : 1783-1786, 2004
- Uchiyama Y, Abe T, Tanaka N, Kojima K, Uchida M, Hirohata M, et al. : Factors contributing to blood-brain barrier disruption following intracarotid injection of nonionic iodinated contrast medium for cerebral angiography : experimental study in rabbits. Radiat Med 24 : 321-326, 2006 https://doi.org/10.1007/s11604-006-0030-5
- Velden J, Milz P, Winkler F, Seelos K, Hamann GF : Nonionic contrast neurotoxicity after coronary angiography mimicking subarachnoid hemorrhage. Eur Neurol 49 : 249-251, 2003 https://doi.org/10.1159/000070198
- Wilson AJ, Evill CA, Sage MR : Effects of nonionic contrast media on the blood-brain barrier. Osmolality versus chemotoxicity. Invest Radiol 26 : 1091-1094, 1991 https://doi.org/10.1097/00004424-199112000-00012
Cited by
- Severe Encephalopathy Following Cerebral Arteriogram in a Patient with End‐Stage Renal Disease vol.26, pp.2, 2011, https://doi.org/10.1111/sdi.12061
- Outcome Differences between Intra-Arterial Iso- and Low-Osmolality Iodinated Radiographic Contrast Media in the Interventional Management of Stroke III Trial vol.36, pp.11, 2015, https://doi.org/10.3174/ajnr.a4421
- Contrast-induced Encephalopathy Following Embolization of Intracranial Aneurysms in Hemodialysis Patients vol.57, pp.12, 2017, https://doi.org/10.2176/nmc.oa.2017-0132
- Acute ischemic stroke mimicking subarachnoid hemorrhage after coronary angioplasty vol.55, pp.3, 2011, https://doi.org/10.1515/rjim-2017-0013
- Confirmation of a Diagnosis by CSF Analysis in a Case of Symptomatic Contrast-induced Encephalopathy with an Onset Immediately after Coil Embolization of an Unruptured Cerebral Aneurysm vol.11, pp.6, 2017, https://doi.org/10.5797/jnet.cr.2016-0137