• 제목/요약/키워드: Scan Model

검색결과 472건 처리시간 0.027초

고령화 환경에서 정보통신 산업의 유망 R&D 영역 발굴 방법 설계 (R&D Opportunity Scan Framework for Information and Telecommunications Company in Aging Society)

  • 이영호;장규남;김영욱;김영진;박명순
    • 경영과학
    • /
    • 제25권3호
    • /
    • pp.59-72
    • /
    • 2008
  • This paper proposes an R&D opportunity scan framework for information and telecommunications company in aging society. The framework consists of trend analysis, market-oriented search, technology-oriented search, and R&D Portfolio development. We identify technology themes in the market-oriented search by developing market scenarios and analyzing a new business model framework. And then we search prospective technologies in the technology-oriented recess by technology scanning and patent analysis. By matching technology themes with prospective technologies, generate an R&D portfolio. Finally, we evaluate the risk of the proposed R&D portfolio.

3차원 인체 형상을 이용한 실버 여성 패션 산업용 인대 모형 개발 (Development of Dress Forms for the Aged Women Based on Their Body Shapes Applying 3D Body Scan Data)

  • 김수아;최혜선
    • 복식문화연구
    • /
    • 제18권1호
    • /
    • pp.80-92
    • /
    • 2010
  • This research aims at developing the dress form for the aged women based on their body shapes using the three-dimensional body scan data with the body shape categorization(according to the previous research). To accomplish this goal, the sample group of representative body shape of the 50% of median was selected by using the high frequency proportion range of each type of body shape of the aged women, and the sample group of representative body shape of each type was averaged in a three-dimensional way by using the morphing method of a three-dimension reverse-engineered software. RP in the form of torso was produced based on the shape data of the final model and the data was formed into an actual object, by which an aged women's dress form model was drawn out. The differences of the girth of the bust, hip and waist between the developed dress form model and the existing dress form model were examined. The result showed that the developed dress form had a bigger size of waist girth than that of bust and hip girth, compared to the existing dress form, which shows that it reflects the aged women's tendency of abdomen obesity, so it's expected to be more proper for the human bodies of the targeted age group than the existing dress form. These research results may help design the clothing suitable for the body shape of the aged women so that their demand for the clothing of good fit will be satisfied in the future.

Rigorous Modeling of the First Generation of the Reconnaissance Satellite Imagery

  • Shin, Sung-Woong;Schenk, Tony
    • 대한원격탐사학회지
    • /
    • 제24권3호
    • /
    • pp.223-233
    • /
    • 2008
  • In the mid 90's, the U.S. government released images acquired by the first generation of photo reconnaissance satellite missions between 1960 and 1972. The Declassified Intelligent Satellite Photographs (DISP) from the Corona mission are of high quality with an astounding ground resolution of about 2 m. The KH-4A panoramic camera system employed a scan angle of $70^{\circ}$ that produces film strips with a dimension of $55\;mm\;{\times}\;757\;mm$. Since GPS/INS did not exist at the time of data acquisition, the exterior orientation must be established in the traditional way by using control information and the interior orientation of the camera. Detailed information about the camera is not available, however. For reconstructing points in object space from DISP imagery to an accuracy that is comparable to high resolution (a few meters), a precise camera model is essential. This paper is concerned with the derivation of a rigorous mathematical model for the KH-4A/B panoramic camera. The proposed model is compared with generic sensor models, such as affine transformation and rational functions. The paper concludes with experimental results concerning the precision of reconstructed points in object space. The rigorous mathematical panoramic camera model for the KH-4A camera system is based on extended collinearity equations assuming that the satellite trajectory during one scan is smooth and the attitude remains unchanged. As a result, the collinearity equations express the perspective center as a function of the scan time. With the known satellite velocity this will translate into a shift along-track. Therefore, the exterior orientation contains seven parameters to be estimated. The reconstruction of object points can now be performed with the exterior orientation parameters, either by intersecting bundle rays with a known surface or by using the stereoscopic KH-4A arrangement with fore and aft cameras mounted an angle of $30^{\circ}$.

Optimizing the maximum reported cluster size for normal-based spatial scan statistics

  • Yoo, Haerin;Jung, Inkyung
    • Communications for Statistical Applications and Methods
    • /
    • 제25권4호
    • /
    • pp.373-383
    • /
    • 2018
  • The spatial scan statistic is a widely used method to detect spatial clusters. The method imposes a large number of scanning windows with pre-defined shapes and varying sizes on the entire study region. The likelihood ratio test statistic comparing inside versus outside each window is then calculated and the window with the maximum value of test statistic becomes the most likely cluster. The results of cluster detection respond sensitively to the shape and the maximum size of scanning windows. The shape of scanning window has been extensively studied; however, there has been relatively little attention on the maximum scanning window size (MSWS) or maximum reported cluster size (MRCS). The Gini coefficient has recently been proposed by Han et al. (International Journal of Health Geographics, 15, 27, 2016) as a powerful tool to determine the optimal value of MRCS for the Poisson-based spatial scan statistic. In this paper, we apply the Gini coefficient to normal-based spatial scan statistics. Through a simulation study, we evaluate the performance of the proposed method. We illustrate the method using a real data example of female colorectal cancer incidence rates in South Korea for the year 2009.

인체 족부 근골격계 상세 유한요소모델링을 통한 족저압 해석 (Pressure Analysis of the Plantar Musculoskeletal Fascia Using a Fine Finite-Element Model)

  • 전성모;김철
    • 대한기계학회논문집A
    • /
    • 제35권10호
    • /
    • pp.1237-1242
    • /
    • 2011
  • 족저부의 압력 분포를 해석하기 위하여 인체에 근접한 족부 상세 해석용 모델을 개발하였다. 이 상세 해석용 모델은 족부의 단층촬영 영상(CT scan image)으로부터 밀도 차이에 따라서 골격부와 피부 및 피하조직을 각각 3D CAD 모델로 변환한 후에 결합하여 구성하였며, 근육과 뼈, 피부 모두를 반영한 3D 족부 유한요소해석 모델로 개발하였다. 개발된 3D 족부 유한요소모델에 대하여 NASTRAN의 접촉해석을 수행하여 족저압의 분포를 계산하였으며, 이러한 결과는 균일분포압력을 작용시키는 당뇨병 환자용 신발 설계의 기초 자료로 활용될 수 있다.

3차원 자동체형계측기 정밀도 검사 (An Accuracy Analysis of the 3D Automatic Body Measuring Machine)

  • 전수형;권석동;박세정;김정양;송정훈;김현진;김종원
    • 사상체질의학회지
    • /
    • 제20권1호
    • /
    • pp.42-47
    • /
    • 2008
  • 1. Objectives The Body Shape and Feature is one of the important standard for classification of Sasang Constitutions. In order to evaluate one's Body Shape and Feature objectively we have been developing the Body Measuring Machine. Now we develop the 3D Automatic Body Measuring Machine(3D-ABMM). So we make an analysis of the 3D-ABMM's Accuracy. 2. Methods By using the 3D-ABMM and Vivid 9i(3D laser scanner, Konica Minolta) we have a surface scan of the three objects which are the upper body of the female and male Manikin and a male model. We overlap each scan data using the RapidForm2006 (3D scan data solution, INUS Technology) and calculate the average distance and standard deviation between the same point of each scan data. 3. Results and Conclusions In the female Manikin, the average distance is 0.84mm and the standard deviation is 1.16mm and the maximum distance is 10.68mm. In the male Manikin, the average distance is 1.12mm and the standard deviation is 1.19mm and the maximum distance is 12.00mm. In the male model, the average distance is 3.26mm and the standard deviation is 2.59mm and the maximum distance is 12.75mm. From the results, 3D-ABMM has good accuracy for scanning body and will be a usable hardware of the 3D Automatic Body Analysis Machine.

  • PDF

Influence of Band and Loop Type Space Maintainer on Intraoral Scanning Accuracy of an Adjacent Tooth

  • Ju Ri Ye;Yong Kwon Chae;Ko Eun Lee;Hyo-Seol Lee;Sung Chul Choi;Ok Hyung Nam
    • Journal of Korean Dental Science
    • /
    • 제16권2호
    • /
    • pp.149-155
    • /
    • 2023
  • Purpose: The purpose of this study was to evaluate whether the presence of a space maintainer affects the accuracy of an intraoral scanner. Materials and Methods: The maxillary primary first molar typodont tooth was removed from the primary dentition typodont model and a band and loop type space maintainer was delivered. After the model was connected to a dental phantom, intraoral scan was performed using TRIOS 4 (3Shape A/S, Copenhagen, Denmark). The scan was repeated with the same technique without the space maintainer. Each scan was performed 10 times. All scan files into a GOM inspect 2018 software and evaluated the accuracy. The accuracy was evaluated on trueness and precision, and calculated using the root mean square value. Result: When there was a space maintainer in the oral cavity, the trueness value was 0.10±0.02 mm and the precision value was 0.15±0.03 mm. In the absence of the space maintainer, the trueness value was 0.12±0.03 mm and the precision value was 0.16±0.04 mm. There were no significant differences depending on the presence of a space maintainer (P>0.05). Conclusion: Within the limits of this study, the accuracy of the intraoral scanner was not influenced by the presence of space maintainer.

거울 및 단일 카메라를 이용한 3차원 발 스캐너 (A 3D Foot Scanner Using Mirrors and Single Camera)

  • 정성엽;박상근
    • 한국CDE학회논문집
    • /
    • 제16권1호
    • /
    • pp.11-20
    • /
    • 2011
  • A structured beam laser is often used to scan object and make 3D model. Multiple cameras are inevitable to see occluded areas, which is the main reason of the high price of the scanner. In this paper, a low cost 3D foot scanner is developed using one camera and two mirrors. The camera and two mirrors are located below and above the foot, respectively. Occluded area, which is the top of the foot, is reflected by the mirrors. Then the camera measures 3D point data of the bottom and top of the foot at the same time. Then, the whole foot model is reconstructed after symmetrical transformation of the data reflected by mirrors. The reliability of the scan data depends on the accuracy of the parameters between the camera and the laser. A calibration method is also proposed and verified by experiments. The results of the experiments show that the worst errors of the system are 2 mm along x, y, and z directions.

Monotonic and Parallelizable Algorithm for Simultaneous Reconstruction of Activity/Attenuation using Emission data in PET

  • Kim, Seung-Gu
    • Communications for Statistical Applications and Methods
    • /
    • 제8권1호
    • /
    • pp.299-309
    • /
    • 2001
  • In PET(Positron Emission Tomography), it is necessary to use transmission scan data in order to estimate the attenuation map. Recently, there are several empirical studies in which one might be able to estimate attenuation map and activity distribution simultaneously with emissive sinogram alone without transmission scan. However, their algorithms are based on the model in which does not include the background counts term, and so is unrealistic. If the background counts component has been included in the model, their algorithm would introduce non-monotonic reconstruction algorithm which results in vain in practice. in this paper, we develop a monotonic and parallelizable algorithm for simultaneous reconstruction of both characteristics and present the validity through some simulations.

  • PDF

Two-Dimensional Numerical Modeling and Simulation of Ultrasonic Testing

  • Yim, Hyun-June;Baek, Eun-Sol
    • 비파괴검사학회지
    • /
    • 제22권6호
    • /
    • pp.649-658
    • /
    • 2002
  • As an attempt to further improve the reliability and effectiveness of ultrasonic testing (UT), a two-dimensional numerical simulator of UT was developed. The simulator models the wave medium (or test object) using the mass-spring lattice model (MSLM) that consists of mass-points and springs. Some previous simulation results, obtained by using MSLM, are briefly reviewed in this paper, for propagation, reflection, and scattering of ultrasonic waves. Next, the models of transmitting and receiving piezoelectric transducers are introduced with some numerical results, which is a main focus of this paper. The UT simulator, established by combining the transducer models with the MSLM, was used to simulate many UT setups. In this paper, two simple setups are considered as examples, and their simulated A-scan signals are discussed. The potential of the MSLM, transducer models, and the UT simulator developed in this study to be used in the actual UT is confirmed.