• 제목/요약/키워드: Scaling factor (N)

Search Result 36, Processing Time 0.019 seconds

Scaling Factor Design Based Variable Step Size Incremental Resistance Maximum Power Point Tracking for PV Systems

  • Ahmed, Emad M.;Shoyama, Masahito
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.164-171
    • /
    • 2012
  • Variable step size maximum power point trackers (MPPTs) are widely used in photovoltaic (PV) systems to extract the peak array power which depends on solar irradiation and array temperature. One essential factor which judges system dynamics and steady state performances is the scaling factor (N), which is used to update the controlling equation in the tracking algorithm to determine a new duty cycle. This paper proposes a novel stability study of variable step size incremental resistance maximum power point tracking (INR MPPT). The main contribution of this analysis appears when developing the overall small signal model of the PV system. Therefore, by using linear control theory, the boundary value of the scaling factor can be determined. The theoretical analysis and the design principle of the proposed stability analysis have been validated using MATLAB simulations, and experimentally using a fixed point digital signal processor (TMS320F2808).

시이섭동기법을 이용한 모델 절감화의 오금 산정 및 관련 파라미터의 추정에 관한 연구 (A Study on Errors and Selection of Associated Parameters in Model Simplification Using Singular Perturbation Technique)

  • 천희영;박귀태;이기상
    • 대한전기학회논문지
    • /
    • 제32권2호
    • /
    • pp.43-49
    • /
    • 1983
  • In this study, model simplification problem using singular perturbation technique is considered. The correctness and errors of simplified model which is obtained by the use of this technique, depends upon the order and the time scaling factor of the simplified model But, unfortunately, there is no explicit criteria for selections of these parameters. In this paper, error equations are derived and expanded by using the useful properties of $L_2$-norm. Then, new criteria for selecting the order of the simplified model and time scaling factor with respect to error bound are suggested. Since these criteria, newly proposed in this study, have strong concern about error bound, it can be used to choose the minimum order of the simplified model and time scaling factor with respect to given error bound. Conversely, if the order of the simplified model and time scaling factor are given, the error induced by the simplification can also be computed easily.

퍼지제어 시스템을 위한 이득동조 방법 (Scaling Factor Tuning Method for Fuzzy Control System)

  • 최한수;김성중
    • 대한전기학회논문지
    • /
    • 제43권5호
    • /
    • pp.819-826
    • /
    • 1994
  • This paper deals with a self-tuning fuzzy controller. The fuzzy controller is constructed with linguistic rules which consist of the fuzzy sets. Each fuzzy set is characterized by a membership function. The tuning fuzzy controller has paramenters that are input/output scaling factors to effect control output. In this paper we propose a tuning method for the scaling factor Computer simulations carried out on first-order and second-order processes will show how the present tuning approach improves the transient and the steady-state characteristics of the overall system.The applicability of the proposed algorithm is certified by computer simulation results.

A New Scaling Theory for the Effective Conducting Path Effect of Dual Material Surrounding Gate Nanoscale MOSFETs

  • Balamurugan, N.B.;Sankaranarayanan, K.;Suguna, M.
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제8권1호
    • /
    • pp.92-97
    • /
    • 2008
  • In this Paper, we present a scaling theory for dual material surrounding gate (DMSGTs) MOSFETs, which gives a guidance for the device design and maintaining a precise subthreshold factor for given device parameters. By studying the subthreshold conducting phenomenon of DMSGTs, the effective conductive path effect (ECPE) is employed to acquire the natural length to guide the design. With ECPE, the minimum channel potential is used to monitor the subthreshold behavior. The effect of ECPE on scaling factor significantly improves the subthreshold swing compared to conventional scaling rule. This proposed model offers the basic designing guidance for dual material surrounding gate MOSFETs.

퍼지제어기을 위한 입출력이득요소 설계 (I/O Scaling Factors Design for Fuzzy Controller)

  • 정창규;이감연;정헌;김영동;고낙용;최한수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 B
    • /
    • pp.990-992
    • /
    • 1996
  • The design of I/O scaling factors for fuzzy controller system is proposed in this paper. The proposed method is for nonlinear input scaling factor and variable output scaling factor. The fuzzy controller is evaluated by computer simulation on the 1st order process and 2nd order process. Simulation results showed robust characteristics for variable reference signal.

  • PDF

RMESH 구조에서 선형 사진트리의 영역 확장과 스케일링을 위한 상수시간 알고리즘 (Constant Time Algorithms for Region Expansion and Scaling of Linear Quadtrees on RMESH)

  • 우진운
    • 정보처리학회논문지A
    • /
    • 제11A권3호
    • /
    • pp.173-180
    • /
    • 2004
  • 계층적 자료구조인 사진트리는 영상을 표현하는데 매우 중요한 자료구조이다. 사진트리를 메모리에 저장하는 방법 중 선형 사진트리 표현방법은 다른 표현 방법과 비교할 때 저장 공간을 매우 효율적으로 절약할 수 있는 이점이 있기 때문에 사진트리와 관련된 연산의 수행을 위해 선형 사진트리를 사용하는 효율적인 알고리즘 개발에 많은 연구가 진행되어 왔다. 영역 확장은 영상을 주어진 거리만큼 확장시키는 연산이고, 스케일링은 영상을 주어진 크기만큼 증폭시키는 연산으로 영상의 기하학적 연산에 속한다. 본 논문에서는 RMESH(Reconfigulrable MESH) 구조에서 3-차원 n${\times}$n${\times}$n 프로세서를 사용하여 선형 사진트리로 표면된 영상의 영역 확장과 스케일링을 수행하는 효율적인 알고리즘을 제안한다. 이 알고리즘은 n${\times}$n${\times}$n RMESH의 계층구조에서 선형 사진트리의 위치코드들을 효율적으로 전송할 수 있는 기본적인 연산들을 이용함으로써 상수 시간의 시간복잡도를 갖는다.

Photovoltaic Modified β-Parameter-based MPPT Method with Fast Tracking

  • Li, Xingshuo;Wen, Huiqing;Jiang, Lin;Lim, Eng Gee;Du, Yang;Zhao, Chenhao
    • Journal of Power Electronics
    • /
    • 제16권1호
    • /
    • pp.9-17
    • /
    • 2016
  • Maximum power point tracking (MPPT) is necessary for photovoltaic (PV) power system application to extract the maximum possible power under changing irradiation and temperature conditions. The β-parameter-based method has many advantages over conventional MPPT methods; such advantages include fast tracking speed in the transient stage, small oscillations in the steady state, and moderate implementation complexity. However, a problem in the implementation of the conventional beta method is the choice of an appropriate scaling factor N, which greatly affects both the steady-state and transient performance. Therefore, this paper proposes a modified β-parameter-based method, and the determination of the N is discussed in detail. The study shows that the choice of the scaling factor N is determined by the changes of the value of β during changes in irradiation or temperature. The proposed method can respond accurately and quickly during changes in irradiation or temperature. To verify the proposed method, a photovoltaic power system with MPPT function was built in Matlab/Simulink, and an experimental prototype was constructed with a solar array emulator and dSPACE. Simulation and experimental results are illustrated to show the advantages of the improved β-parameter-based method with the optimized scaling factor.

Experimental analysis of rocking shallow foundation on cohesive sand

  • Moosavian, S.M. Hadi;Ghalandarzadeh, Abbas;Hosseini, Abdollah
    • Earthquakes and Structures
    • /
    • 제22권6호
    • /
    • pp.597-608
    • /
    • 2022
  • One of the most important parameters affecting nonlinearsoil-structure interaction, especially rocking foundation, is the vertical factor of safety (F.Sv). In this research, the effect of F.Sv on the behavior of rocking foundations was experimentally investigated. A set of slow, cyclic, horizontal loading tests was conducted on elastic SDOF structures with different shallow foundations. Vertical bearing capacity tests also were conducted to determine the F.Sv more precisely. Furthermore, 10% silt was mixed with the dry sand at a 5% moisture content to reach the minimum apparent cohesion. The results of the vertical bearing capacity tests showed that the bearing capacity coefficients (Nc and Nγ) were influenced by the scaling effect. The results of horizontal cyclic loading tests showed that the trend of increase in capacity was substantially related to the source of nonlinearity and it varied by changing F.Sv. Stiffness degradation was found to occur in the final cycles of loading. The results indicated that the moment capacity and damping ratio of the system in models with lower F.Sv values depended on soil specifications such cohesiveness or non-cohesiveness and were not just a function of F.Sv.

동계 광양만에서 식물플랑크톤 군집구조의 수평적 분포특성과 성장에 미치는 영양염 제한 특성 (Characteristics of Horizontal Community Distribution and Nutrient Limitation on Growth Rate of Phytoplankton during a Winter in Gwangyang Bay, Korea)

  • 백승호;김동선;현봉길;최현우;김영옥
    • Ocean and Polar Research
    • /
    • 제33권2호
    • /
    • pp.99-111
    • /
    • 2011
  • To estimate the effects of limitation nutrients for phytoplankton growth and its influences on short-term variations of a winter phytoplankton community structure, we investigated the abiotic and biotic factors of surface and bottom waters at 20 stations of inner and offshore areas from 6 to 7 February in Gwangyang Bay, Korea. Also, several algal bio-assay studies were conducted to identify any additional nutrient effects on phytoplankton assemblage using surface water for the assay. The dominant species in the bay was diatom Skeletonema costatum, which occupied more than 70% of total species in most stations (St.1-16) of the inner bay. According to a cluster and multidimensional scaling (MDS) analysis based on phytoplankton community data from each station, the bay was divided into three groups. The first group included stations from the south-western parts of Myodo lsland, which can be characterized as a semien-closed eutrophic area with high phytoplankton abundance. The second group included most stations from the north-eastern part of Myodo lsland, influenced indirectly by surface water currents from offshore of the bay. The standing phytoplankton crops were lower than those of the first group. The other cluster was restricted to samples collected from offshore of the bay. In the bay, silicon (Si) and phosphorus (P) were not a major limiting factor for phytoplankton production. However, since the DIN: DIP and DSi: DIN ratios clearly demonstrated that there were potential stoichiometric N limitations, nitrogen (N) was considered as a limiting factor. Based on the algal bio-assay, in vivo fluorescence values in N (+) added experiments were higher compared to control and P added experiments. Our results suggested that nitrogen may act as one of the most important factors in controlling primary production during winter in Gwangyang Bay.

On the symmetric sierpinski gaskets

  • Song, Hyun-Jong;Kang, Byung-Sik
    • 대한수학회논문집
    • /
    • 제12권1호
    • /
    • pp.157-163
    • /
    • 1997
  • Based on a n-regular polygon $P_n$, we show that $r_n = 1/(2 \sum^{[(n-4)/4]+1}_{j=0}{cos 2j\pi/n)}$ is the ratio of contractions $f_i(1 \leq i \leq n)$ at each vertex of $P_n$ yielding a symmetric gasket $G_n$ associated with the just-touching I.F.S. $g_n = {f_i $\mid$ 1 \leq i \leq n}$. Moreover we see that for any odd n, the ratio $r_n$ is still valid for just-touching I.F.S $H_n = {f_i \circ R $\mid$ 1 \leq i \leq n}$ yielding another symmetric gasket $H_n$ where R is the $\pi/n$-rotation with respect to the center of $P_n$.

  • PDF