• Title/Summary/Keyword: Scale of Center

Search Result 5,678, Processing Time 0.034 seconds

Operation Direction of Regional Architectural Safety Center through Analysis of Japanese Building Confirmation System (일본의 건축확인제도 분석을 통한 지역건축안전센터의 운영 방향 설정)

  • Baek, Cheong-Hoon;Kim, Eun-Young
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.5
    • /
    • pp.11-20
    • /
    • 2018
  • To prevent illegal building work in advance, regional building safety centers were introduced to perform technical investigations and management. The purpose of this study is to propose the detailed operational directions of the regional building safety center through the analysis on the current status of parameters, such as the operation of designated confirmation and inspection bodies in Japan. We consider the role, building administrative process and establishment criteria of regional building safety centers through the analysis the introduction background and the designation criteria of designated confirmation and inspection bodies. In establishing the center's professional manpower qualifications, we refer to the criteria for the professional qualifications of the designated confirmation and inspection bodies. In addition, the calculation method of required manpower of verification inspectors in Japan was used as a reference in setting the scale of regional professional manpower. Finally, we propose the detailed operational directions of the regional building safety center such as (1)roles of the center, (2)establishing management plan of the center, (3)work scope (4)scale of the professional manpower, (5)qualification of the professional manpower, and (6)funds.

Substrate tempperature dependence of crystalline Y2O3 films grown by Ionized Cluster Beam Deposition

  • Cho, M.H.;Whangbo, S.W.;Seo, J.G.;Choi, S.C.;Cho, S.J.;Whang, C.N.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.87-89
    • /
    • 1998
  • The Y2O3 films on Si(111) was grown by ionized cluster beam depposition (ICBD) in ultrahigh-vacuum (UHV). The acceleration voltage and oxygen ppartial ppressure were fixed at 5 kV and 2$\times$10-5 Torr resppectively. The substrate tempperature was varied from 10$0^{\circ}C$ to $600^{\circ}C$ in order to find the deppendence of crystallinity of Y2O3 films on the substrate tempperature. The crystallinity of the films with the substrate tempperature studied using x-ray diffraction (XRD) and Rutherford backscattering sppectroscoppy (RES). Surface crystallinity and surface morpphology of the films were also investigated using the reflection high-energy electron diffraction (RHEED) and atomic force microscoppe (AFM) resppectively. The films grown at the substrate tempperature below 50$0^{\circ}C$showed the ppoly-crystalline structure of oxygen deficiency. On the contrary the single-crystalline structure was obtained at the substrate tempperature over 50$0^{\circ}C$ and the stochimetry was gradually matched as increasing the substrate tempperature. The surface morpphology showed the increase of the surface roughness as the substrate tempperature was increased upp to 50$0^{\circ}C$ The crystallinity of the film was not good and the minimum channeling yield $\chi$min was measured at 0.91 The stochiometric and high crystallinine film (surface $\chi$min=0.25) was obtained as the substrate tempperature increased upp to 60 $0^{\circ}C$ which indicate the tempperature was sufficient to migrate the depposited atom.

  • PDF

Surface Characteristics and Micro-Scale Friction Property of Natural Surface (식물잎의 표면형상 및 마이크로-스케일에서의 마찰 특성)

  • Yoon, Eui-Sung;Kim, Hong-Joon;Singh R. Arvind;Kim, Jin-Seok
    • Tribology and Lubricants
    • /
    • v.22 no.5
    • /
    • pp.237-242
    • /
    • 2006
  • Surfaces found in nature, including biological surfaces have been providing inspiration to modify/fabricate artificial surfaces as solutions for tribological applications. As an example, the concept of 'lotus-effect' has motivated tribologists world wide to modify/fabricate surfaces for enhanced tribological performance. These was done by creating nano/micro-scale asperities on various surfaces using ion beam milling and ion-beam assisted roughening. In order to understand the attributes of natural surfaces, which are inspirational to tribologists, we characterized the surface of two natural surfaces-Nelumbo nucifera (lotus) and Colocasia esculenta leaves. Further, we evaluated their micro-scale friction property, both in their fresh and dried conditions. The characterization of surfaces was conducted using a confocal microscope and SEM, which involved the evaluation of size and distribution of protuberances. The micro-scale friction property was evaluated using a ball-on-flat type micro-tribo tester, under reciprocating motion. A soda lime glass ball (2 mm diameter) was used in these tests. Tests were conducted at the applied normal load of $3000{\mu}N$, at a sliding speed of 1 mm/sec for a scan length of 3 mm. All experiments were conducted at ambient temperature ($24{\pm}1^{\circ}C}$) and relative humidity ($45{\pm}5%$). It was observed that the friction behaviour of the natural surfaces was influenced by their surface characteristics (morphology and distribution of protuberances) and also by the condition (fresh or dried) in which they were tested.

Efficacy of Combining Proximal Balloon Guiding Catheter and Distal Access Catheter in Thrombectomy with Stent Retriever for Anterior Circulation Ischemic Stroke

  • Kim, Sang Hwa;Choi, Jae Hyung;Kang, Myung Jin;Cha, Jae Kwan;Kim, Dae Hyun;Nah, Hyun Wook;Park, Hyun Seok;Kim, Sang Hyun;Huh, Jae Taeck
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.4
    • /
    • pp.405-413
    • /
    • 2019
  • Objective : We evaluated efficacy of combining proximal balloon guiding catheter (antegrade flow arrest) and distal access catheter (aspiration at the site of occlusion) in thrombectomy for anterior circulation ischemic stroke. Methods : We retrospectively analyzed 116 patients who underwent mechanical thrombectomy with stent retriever. The patients were divided by the techniques adopted, the combined technique (proximal balloon guiding catheter and large bore distal access catheter) group (n=57, 49.1%) and the conventional (guiding catheter with stent retriever) technique group (n=59, 50.9%). We evaluated baseline characteristics (epidemiologic data, clinical and imaging characteristics) and procedure details (the number of retrieval attempts, procedure time), as well as angiographic (thrombolysis in cerebral infarction (TICI) score, distal thrombus migration) and clinical outcome (National Institutes of Health Stroke Scale at discharge, modified Rankin Scale [mRS] at 3 months) of them. Results : The number of retrieval attempts was lower (p=0.002) and the first-pass successful reperfusion rate was higher (56.1% vs. 28.8%; p=0.003) in the combined technique group. And the rate of final result of TICI score 3 was higher (68.4% vs. 28.8%; p<0.01) and distal thrombus migration rate was also lower (15.8% vs. 40.7%; p=0.021) in the combined technique group. Early strong neurologic improvement (improvement of National Institutes of Health Stroke Scale ${\geq}11$ or National Institutes of Health Stroke Scale ${\leq}1$ at discharge) rate (57.9% vs. 36.2%; p=0.02) and favorable clinical outcome (mRS at 3 months ${\leq}2$) rate (59.6% vs. 33.9%; p=0.005) were also better in the combined technique group. Conclusion : The combined technique needs lesser attempts, decreases distal migration, increases TICI 3 reperfusion and achieves better clinical outcomes.

The Validation of Korean Version of Five Facet Mindfulness Questionnaire Short Form (한국판 5요인 마음챙김 단축형 척도 타당화 연구)

  • Cheong, Moon Joo;Chae, Eun Young;Lyu, Yeoung Su;Kang, Hyung Won
    • Journal of Oriental Neuropsychiatry
    • /
    • v.28 no.3
    • /
    • pp.207-216
    • /
    • 2017
  • Objectives: To simplify the mindfulness scale and to ensure reliability and validity of the scale. Methods: To develop scale items using the original scale and to identify factor structure of the scale, exploratory factor analysis was conducted based on results of factor analysis, the short-form 5-factor mindfulness scale item was selected. Internal consistency coefficient was calculated and confirmatory factor analysis was conducted to verify reliability of the short-form scale. Finally, to verify validity of the abbreviated scale, we conducted correlation analysis with the abbreviated scale and the mindfulness scale (FFMQ). Results: As with the original scales, scaled scales were composed of 5 factors and consisted of 15 items in total. Factor analysis revealed factor loadings were adequate and reliability and validity were secured. Conclusions: It provided that mindfulness shortening scale validation can be used more simply to measure mindfulness in the clinical scene.

Alcohol Intoxication and Glasgow Coma Scale Scores in Patients with Head Trauma

  • Park, Jisoo;Park, Taejin;Ko, Jung-In;Yeo, Woonhyung
    • Journal of Trauma and Injury
    • /
    • v.33 no.4
    • /
    • pp.227-235
    • /
    • 2020
  • Purpose: Alcohol intoxication is commonly associated with traumatic brain injury (TBI), but the influence of alcohol on the Glasgow Coma Scale (GCS) score remains unclear. This study investigates the effects of blood alcohol concentration (BAC) on the GCS score in head trauma patients with alcohol intoxication. Methods: In total, 369 head trauma patients with alcohol intoxication in a 1-year period were retrospectively analyzed. The patients underwent head computed tomography and had a BAC ≥80 mg/dL. Patients were divided into TBI and non-TBI groups. Brain injury severity was further classified using the head Abbreviated Injury Score (AIS). The effects according to 5 BAC groups were examined. Results: The TBI group consisted of 64 patients (16.2%). The mean BAC was significantly higher in the non-TBI group (293.4±87.3 mg/dL) than in the TBI group (242.8±89.9 mg/dL). The mean GCS score was significantly lower in the TBI group (10.3±4.6) than in the non-TBI group (13.0±2.5). A higher BAC showed a significant association with a lower mean GCS score in the TBI group, but not in the non-TBI group. Above ≥150 mg/dL, higher BACs showed significant odds ratios for a lower GCS score. Conclusions: The influence of alcohol in patients with head trauma depended on the presence of a brain injury. An association between a higher BAC and a lower GCS score was only observed in patients with TBI. Therefore, if a severe brain injury is suspected based on a GCS evaluation in patients with alcohol intoxication, prompt diagnosis and intensive care should be performed without delay.

Study and three Cases Report for Lumbar Spinal Stenosis Treatment Using a Combination of Acupotomy and Existing Treatments (기존치료법과 침도침 시술을 병행한 요추관협착증의 증례보고 및 분석)

  • Jung, Ki-Yong;Sur, Young-Chan;Jang, Woo-Soon;Lee, Ji-Eun;Kim, Kyoung-Hoon;Shin, Gwang-Soon;Han, You-Sik
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.26 no.1
    • /
    • pp.120-127
    • /
    • 2012
  • This study reports the effect of acupotomy for patients diagnosed with lumbar spinal stenosis(LSS). We treated three patients diagnosed with LSS using acupotomy. We measured the Numerical Rating Scale(NRS), Oswestry Disability Index(ODI) scores and Odom's criteria before and after treatment to assess improvements in symptoms and functions. In all patients, NRS, ODI scores and Odom's criteria were improved. We found a beneficial effect with acupotomy for three patients diagnosed with LSS. Thus, these data suggest LSS may be treated successfully with acupotomy.

A Study on the appropriateness of Public Facilities Scale (기능전환에 따른 동사무소 공간의 적정규모에 관한 연구)

  • Lee Jeong-Ho
    • Journal of the Korean housing association
    • /
    • v.16 no.1
    • /
    • pp.65-72
    • /
    • 2005
  • With the changing consciousness of community people and the rising standard of living, there has recently been an emphasis on the creation of public facilities' new functions and their role as local community facilities. This changing trends are accordingly requiring a change in spatial structure of the public facilities. In this study, an analysis was conducted with 24 public facilities situated in the Buk-gu district of Daegu to identify the adequacy of their space scale after functional variation. The results of this study are summarized as follows. 1) The site area of public facilities has been being widened after functional variation since more spaces are needed to provide an outdoor resting space with community people, expand a parking space, and operate a community center. 2) The factors that had a direct effect on the change in the use of space are the reduced space for administrative work and the expanded scope of the community center's function. Specifically, the areas of activities for civil service and administrative work and for reserve forces have been reduced due to reduction of function, and floor division by each function group has been becoming stricter due to addition of a community center's function. 3) It was shown that in terms of the space for functions of public facilities, spaces for civil service and waiting have increased mostly after function variation. After functional variation, the scale of spaces for civil service and administrative work has been being planned within the range of $200\~300 m^2$, regardless of the number of population to be covered by public facilities. 4) The space for public use is showing the greatest increase in public facilities which have been built after functional variation. The major factors seem to be the increased moving passages, the expanded convenient facilities for community people, and the increased convenient facilities for disabled. Facilities scale plans have been being made more systematically, compared to the conventional facilities.

The Generation of Vacuum Scale Using the Vapour Pressure of Water (물의 증기압을 이용한 진공도눈금의 생성)

  • Seong D. J.;Shin Y. H.;Chung K. H.
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.4
    • /
    • pp.180-185
    • /
    • 2005
  • The possibility of generation of the vacuum scale using the vapour pressure of water was evaluated. The range of vacuum from 3.3 kPa to 101.3 kPa was corresponds the vapour pressure of water in the temperature range from $25^{\circ}C$ to $100^{\circ}C$ The measured values of the vapour pressure of water were agreed within the deviation of $5\%$ comparing to reference value. This result shows the vapour pressure of water can be used as an secondary reference of the vacuum scale. Moreover it shows the thermo-dynamical properties such as, triple point, temperature-pressure curve of a material have a applicability in the vacuum scale as a reference in corresponding range of vacuum.

Scale Development of Family Strength for Dual-Earner Families with Children (자녀가 있는 맞벌이가정의 건강성 척도 개발 연구)

  • Song, Hyerim;Koh, Sun-Kang;Kang, Eunju
    • Journal of Family Resource Management and Policy Review
    • /
    • v.27 no.3
    • /
    • pp.1-19
    • /
    • 2023
  • This study aims to develop a family strength scale for dual-earner families with young children. Based on existing theories of family strength and a review of related literature, we draw on 80 items to measure the strength of dual-earner families. Using a sample of 747 people, all members of dual-earner families with young children, we examined the items' factor structures. Using the statistical method, we checked the validity and reliability of these items. The final scale consisted of four domains with a total of 49 items : basic foundation (basic structure, economic life, and resource management), parenting, social interest and participation (citizenship, volunteer, leisure, network), work-life balance (balance between work and family, sharing the family role, equal division of role). The developed scale can be used in the field, such as in the Healthy Family Support Center or Family Center, in the context of education, counseling, or consulting for dual-earner families. In order to enhance the usefulness and efficiency of the scale, the adequate education system for the professionals who handle this scale in the field and updated data are required.