• Title/Summary/Keyword: Scale of Center

Search Result 5,650, Processing Time 0.033 seconds

The Relationship between Dynamic Balance Measures and Center of Pressure Displacement Time in Older Adults during an Obstacle Crossing

  • Park, Seol;Park, Ji-Won
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.3
    • /
    • pp.1-5
    • /
    • 2011
  • Purpose: This study examined the relationship between the center of pressure (COP) displacement time during the stance phase and dynamic balance ability when older adults cross a 10 cm obstacle. Methods: Fifteen older adults were enrolled in this study (all ${\geq}65$ years of age). The F-scan was used to measure the COP displacement time when subjects cross a 10 cm obstacle, and the Dynamic gait index. Berg's balance scale and the Four square step test were used to measure dynamic balance ability. Results: The Dynamic gait index, Berg's balance scale and the Four square step test were correlated with each other. Dynamic balance ability was correlated with COP displacement time during the stance phase at an obstacle crossing in older adults. Conclusion: People with higher dynamic balance ability show a smaller COP displacement time during the stance phase at an obstacle crossing. Therefore, dynamic balance ability can be predicted by measuring the center of pressure displacement time.

Acoustic Performance Enhancement in PVDF Speakers by Using Buckled Nanospring Carbon Nanotubes

  • Ham, Sora;Lee, Yun Jae;Kim, Jung-Hyuk;Kim, Sung-Ryong;Choi, Won Kook
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.360-365
    • /
    • 2019
  • A polyvinylidene fluoride (PVDF)-based film speaker is successfully fabricated with enhanced bass sound by incorporating buckled nanospring carbon nanotubes (NS-CNTs) as fillers. Various concentrations up to 1-7 wt% of uniformly dispersed buckled NS-CNTs are loaded to increase the beta (β)-phase fraction, crystallinity, and dielectric constant of the speaker, and this results in the bass part enhancement of about 19 dB full scale (dBFS) at 7 wt% filler loading of the piezoelectric film speaker.

Regional Occurrence and Sedimentary Environment of Manganese Nodule in KODOS area, C-C zone of NE Pacific (북동태평양 한국 심해저 연구지역 망간단괴의 지역적 분포와 퇴적환경)

  • Chi, Sang-Bum;Kang, Jung-Keuk;Oh, Jae-Kyung;Son, Seung-Kyu;Park, Cheong-Kee
    • Ocean and Polar Research
    • /
    • v.25 no.3
    • /
    • pp.257-267
    • /
    • 2003
  • Deep-sea bottom photographs acquired in the Clarion-Clipperton fracture zone of the northeast equatorial Pacific were analyzed to reveal the controlling processes for the spatial variation of manganese nodule. The results show that regional-scale occurrence variations of manganese nodule are mainly controlled by primary productivity of surface water, sedimentation rate, and water depth (or carbonate compensation depth). As a result, the diagenetic accretion on nodules increases toward southwest while hydrogenetic accretion increases toward northeast. Considering the northwestward movement of Pacific Plate, this regional-scale variation of manganese nodule occurrence seems to be affected by oceanic environment during the active growth period (Oligocene-Miocene) of Pacific Plate.

Outcomes of open neck injuries

  • Noh, Dongsub;Choi, Jin Ho
    • Journal of Trauma and Injury
    • /
    • v.35 no.3
    • /
    • pp.168-172
    • /
    • 2022
  • Purpose: The neck is a particularly critical region for penetrating injuries due to the close proximity of the trachea, esophagus, blood vessels, and the spinal cord. An open neck injury has the potential for serious morbidity and mortality. The purpose of this study is to evaluate the assessment and management of open neck injuries. Methods: In this retrospective study, open neck injury patients who were admitted to the Trauma Center of Daejeon Eulji Medical Center, Eulji University between December 2015 and December 2017 were analyzed for epidemiology, the mechanism of trauma, the injured organ, complications, and mortality. Results: Thirty-two patients presented with open neck injuries. All patients underwent computed tomographic angiography to evaluate their injuries once their vital signs stabilized. Among these patients, 27 required surgical treatment. The most commonly injured organ was the airway. There were five deaths, and the main cause of death was bleeding. Mortality was associated with the initial systolic blood pressure at the hospital and Glasgow Coma Scale. Conclusions: Mortality from open neck injuries was associated with initial systolic blood pressure at the hospital and Glasgow Coma Scale.

Comparison of KTAS(Korean Triage and Acuity Scale) results by Triage Classifier (중증도 분류자 직종에 따른 중증도 분류 결과의 차이 비교)

  • Huh, Young-Jin;Oh, Mi-Ra;Kim, Se-Hyung;Han, So-Hyun;Pak, Yun-Suk
    • Journal of Convergence for Information Technology
    • /
    • v.10 no.4
    • /
    • pp.98-103
    • /
    • 2020
  • The purpose of this study was to determine whether the results of KTAS(Korean Triage and Acuity Scale) triage classifier differ according to the occupations. We analyzed a total of 10,960,359 cases of data sent to the NEDIS from January 1st, 2016 to December 31th, 2017. The triage classifier were MD(Medical Doctor), R(Resident), INT(Intern), GP(General Practitioner), RN(Registered Nurses) and EMT(Emergency Medical Technician). The consistency between the initial triage and final triage results was the highest GP(98.9%) and the lowest INT(80.2%). The results of over-triage classification was the lowest by GP(0.6%) and the highest for INT(16.0%). Also, the results of under-triage classification was the lowest by MD, EMT(0.4%) and the highest for INT(3.8%). The results of KTAS triage classifier significantly differ from according to the occupations(p<0.001). Triage classification should not differ from according to occupations and skill. It is necessary to strengthen the classifier's capacity for accurate triage classifications.

Continuous Production of Fructo-oligosaccharides by Immobilized Cells of Aureobasidium pullulans

  • Yun, Jong-Won;Jung, Kyung-Hoon;Jeon, Yeong-Joong;Lee, Jae-Heung
    • Journal of Microbiology and Biotechnology
    • /
    • v.2 no.2
    • /
    • pp.98-101
    • /
    • 1992
  • Continuous production of fructo-oligosaccharides employing a packed bed reactor charged with immobilized cells of Aureobasidium pullulans was investigated. The optimum conditions for reactor operation were a feed concentration of 860 g/l; a feed rate, expressed as superficial space velocity of $0.2\;h^{-1}$, and a temperature of $50^\circ{C}$. Under these optimum conditions, the productivity of the reactor was $180\;g/l\cdot{h}$. Initial activity was maintained for more than 100 days. The reactor was successfully scaled up to a production scale of 1000l.

  • PDF

Operational Characteristics of Pilot Scale Plasma DeSOx-DeNOx System for Treatment of Coal-Fired Flue Gas (석탄연소 배가스 처리용 플라즈마 탈황탈질 시스템의 운전 특성)

  • Jang, Gil-Hong;Paek, Min-Su;Kim, Tae-Hee;Jeong, Jong-Han
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1806-1808
    • /
    • 1998
  • Tests of pilot-scale plasma DeSOx-DeNOx system using pulsed streamer corona were carried out. The system consists of the reactor with wire-plate electrodes the $30kW_{max}$. MPC type pulse generator, and $1MW_{th}$ pulverized coal combustor as a flue gas source. $NH_3$ and $C_2H_4$ were used to enhance the removal rate. The experimental result on the removal efficiency of SOx/NOx and on the effect of the additives was presented in this paper.

  • PDF

Development of 250kW Power Conditioning System for Large Scale Photovoltaic Power Plant (대규모 태양광 발전설비를 위한 전력변환기 개발)

  • Kang, Ho-Hyun;Jung, Hong-Ju;Kim, Wang-Mun;Suh, In-Young
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.640-642
    • /
    • 2008
  • This paper presents the design, development and performance of a 250kW power conditioning system(PCS) for large scale photovoltaic power plant. The PV inverter consists of a three phase IGBT stack, L-C filter, transformer and HMI unit for monitoring. To verify the performance of the PV inverter a testing facility was designed and constructed to simulate the characteristics of the solar cell and grid.

  • PDF

Digital Gray-Scale/Color Image-Segmentation Architecture for Cell-Network-Based Real-Time Applications

  • Koide, Tetsushi;Morimoto, Takashi;Harada, Youmei;Mattausch, Jurgen Hans
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.670-673
    • /
    • 2002
  • This paper proposes a digital algorithm for gray-scale/color image segmentation of real-time video signals and a cell-network-based implementation architecture in state-of-the-art CMOS technology. Through extrapolation of design and simulation results we predict that about 300$\times$300 pixels can be integrated on a chip at 100nm CMOS technology, realizing very high-speed segmentation at about 1600sec per color image. Consequently real-time color-video segmentation will become possible in near future.

  • PDF

Operation Direction of Regional Architectural Safety Center through Analysis of Japanese Building Confirmation System (일본의 건축확인제도 분석을 통한 지역건축안전센터의 운영 방향 설정)

  • Baek, Cheong-Hoon;Kim, Eun-Young
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.5
    • /
    • pp.11-20
    • /
    • 2018
  • To prevent illegal building work in advance, regional building safety centers were introduced to perform technical investigations and management. The purpose of this study is to propose the detailed operational directions of the regional building safety center through the analysis on the current status of parameters, such as the operation of designated confirmation and inspection bodies in Japan. We consider the role, building administrative process and establishment criteria of regional building safety centers through the analysis the introduction background and the designation criteria of designated confirmation and inspection bodies. In establishing the center's professional manpower qualifications, we refer to the criteria for the professional qualifications of the designated confirmation and inspection bodies. In addition, the calculation method of required manpower of verification inspectors in Japan was used as a reference in setting the scale of regional professional manpower. Finally, we propose the detailed operational directions of the regional building safety center such as (1)roles of the center, (2)establishing management plan of the center, (3)work scope (4)scale of the professional manpower, (5)qualification of the professional manpower, and (6)funds.