• Title/Summary/Keyword: Saturation pulse

Search Result 192, Processing Time 0.031 seconds

The effect of acupuncture treated by tonification and sedation manipulation at LI4 and KI7 on lacking of sweating in cold environment(I) (합곡(合谷) 복류(復溜) 보사(補瀉) 시술(施術)이 소한(少汗)에 미치는 영향(影響)(I))

  • Choi, Chan-Hun;Youn, Dae-Hwan;Kim, Young-Sun;Song, Min-Sun;Na, Chang-Su
    • Korean Journal of Acupuncture
    • /
    • v.26 no.4
    • /
    • pp.23-38
    • /
    • 2009
  • Objectives : The purpose of this study was to identify the effect of the tonification & sedation manipulation for LI4 and KI7 on lacking of sweating in cold environment. Methods: The participants were divided into 3 groups as intact group without acupuncture, acupuncture group inserting and twisting with LI4 tonificaton and KI7 sedation method(LI4-tonify KI7-purge) and acupuncture group inserting and twisting with LI4 sedation and KI7 tonificaton method(LI4-purge KI7-tonify). We obtained baseline data at cold condition with the temperature $14{\pm}1^{\circ}C$. After making the participant staying in cold condition for 10 minute, we measured sweating rate in skin surface, body temperature, oxygen saturation, pulse rate, systolic blood pressure, diastolic blood pressure, deoxy-Hb and oxy-Hb in subcutaneous. Results : After acupuncture in cold environment, the sweating rate in skin surface significantly decreased in KI7-purge LI4-tonify group comparing the intact groups. The body temperature significantly increased in LI4-tonify KI7-purge and LI4-purge KI7-tonify groups comparing the intact group. The oxygen saturation significantly increased in LI4-tonify KI7-purge group comparing the intact group. Conclusions : These findings indicated that LI4 tonificaton and KI7 sedation method(LI4-tonify KI7-purge) could be effective for production of sweating in cold condition.

  • PDF

A development of a multimodal patch-type probe for measuring blood flow and oxygen saturation in carotid artery (경동맥 혈류 속도 및 산소 포화도 측정을 위한 다중모드 패치형 프로브 개발)

  • Youn, Sangyeon;Lee, Kijoon;Kim, Jae Gwan;Hwang, Jae Youn
    • The Journal of the Acoustical Society of Korea
    • /
    • v.38 no.4
    • /
    • pp.443-449
    • /
    • 2019
  • To protect the patient's internal organs when a patient with cardiovascular disease occurs, it is important to reduce the elapsed time by providing emergency medical services. Decisions for conducting cardiopulmonary resuscitation are mainly made using the carotid palpation method, which directs the pulse of the carotid artery, which can diagnose the patient's condition according to one's own subject and cause cerebral blood flow to be blocked by excessive pressure in the carotid due to the weaken cardiopulmonary function. In this study, we developed a multimodal patch-type probe based on multi-channel ultrasound Doppler pairs and oxygen saturation measurement modules which can monitor cardiopulmonary functions. From the in-vivo experiments, the developed probe can be utilized as a novel tool that can increase the survival rate of cardiovascular disease patients by objectively monitoring the cardiopulmonary function of the patient quantitatively and promptly in an emergency situation.

COMPARISON OF SEDATIVE EFFECTS BETWEEN THREE ROUTES OF ADMINISTRATION WITH MIDAZOLAM (Midazolam의 투여방법에 따른 진정효과의 비교연구)

  • Kim, Ryoung;Lee, Keung-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.27 no.2
    • /
    • pp.283-291
    • /
    • 2000
  • The purpose of this study was to compare the sedative effect of three routes of administration - intramuscular, intranasal drop-in, intranasal spray - with midazolam. The twenty two uncooperative children from 23 months to 76 months who required at least three dental appointment. Each patient was assigned randomly to receive intramuscular(Group I, 0.15mg/kg), intranasal drop-in(Group II, 0.20mg/kg), intranasal spray(Group III, 0.20mg/kg) administration at each visit. Sleep, crying, movement, and overall behavior response were evaluated, and the sedative effects were evaluated by Houpt's rating scale In order to monitor the sedated patients, pulse rate and peripheral oxygen saturation were measured by pulse oximeter during treatment procedures. The results were as follows 1. Pulse rate and peripheral oxygen saturation were stable through all the treatment procedures, and there were no statistically significant differences among three routes of administration(P>0.05). 2. The effect on sleep was, III, II, I, in order, III group was the most effective through all the treatment procedures, except rubber-dam placement and filling phase (P<0.0001). 3. The effects on crying, movement, overall behavior were II, III, I, in order, II group was the most effective through all treatment procedures(P<0.0001).

  • PDF

Effects of Nurse Presence Program on Anxiety and Physiological Indicators in Patients with Gynecological Surgery (Nurse Presence 프로그램이 산부인과 수술환자의 불안 및 생리적 지수에 미치는 효과)

  • Kim, Yun Jeong;Jo, Kae Hwa
    • Journal of Korean Biological Nursing Science
    • /
    • v.16 no.4
    • /
    • pp.326-333
    • /
    • 2014
  • Purpose: This study was to examine the effects of Nurse Presence (NP) program on anxiety and physiological indicators in patients with gynecological surgery. Methods: This study used a randomized control group pre-test, post-test design. The patients were 25-65 years old who had undergone gynecological surgery with general anesthesia. The subjects were divided into an experimental group (n=30) and the control group (n=30). SPSS 21.0 was used to analyze the data with Chi-square, Fisher's exact test, t-test, and one sample t-test. Results: The results show that there were significant differences in anxiety and heart rate and were no significant differences in systolic pressure or peripheral oxygen saturation of the experimental group which received the NP program. Conclusion: Nurse Presence program decreased pulse rate which is a physiological indicator by relieving the anxiety of the patients before gynecological surgery. Thus, this intervention is effective to relieve anxiety of the patients before gynecological surgery and should be utilized in clinics.

The Sedation Anesthesia for Prolotherapy and Intramuscular Stimulation (증식 치료와 근육내 자극술시의 수면 마취)

  • Jo, Dae Hyun;Kim, Myung Hee;Hong, Ji Hee
    • The Korean Journal of Pain
    • /
    • v.19 no.1
    • /
    • pp.77-80
    • /
    • 2006
  • Background: Painful experiences during procedures such as prolotherapy and intramuscular stimulation are stressful to patients and can affect the treatment outcome. We present a method for relieving pain and increasing the level of patient comfort during the procedure. Methods: Twenty six patients who requested sedation anesthesia during the procedure were examined. All patients were injected with 500 ml of 0.9% normal saline and were monitored by electrocardiography, blood pressure and pulse oximetry. The patients were supplied with oxygen (3 L/min) through a nasal cannula. Midazolam (0.02 mg/kg) and alfentanil ($8{\mu}g/kg$) was injected before the procedure and a bolus injection was administered during the procedure if patients felt any pain. The duration of the procedure, the total amount of drugs, the changes in the systolic blood pressure, heart rate, pulse oxygen saturation, sedation and pain level during procedure, satisfaction scale after the procedure, complications and the incidence of amnesia were evaluated. Results: Twenty one patients had a moderate level of sedation, 15 patients did not feel any pain during the procedure, 17 patients had high level of satisfaction (8-10). No patient experienced complications after the procedure, or unstable vital signs, and 6 patients could not remember the procedure. Conclusions: Sedation anesthesia is a safe method for relieving pain during the procedure, and most patients had a high level of satisfaction.

Characteristics of Pulse Width Modulation(PWM) Excitation of Ultrasonic Elliptical Vibration Cutting Device (초음파 진동절삭기의 펄스폭변조 가진 특성)

  • Loh, Byoung Gook;Kim, Gi Dae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.1
    • /
    • pp.59-65
    • /
    • 2014
  • To obtain an elliptical trajectory at the cutting edge during elliptical vibration cutting, sinusoidal voltage excitations of two piezoelectric actuators have commonly been used. In this study, PWM excitation, which is relatively simple to generate, was employed and its characteristics were investigated. In experimental and analytical analyses, we found that for PWM excitation, the integer-multiple frequencies of the excitation voltage distorted the shape of the elliptical trajectory, whereas at a duty ratio(DR) of 50%, the distortion of the elliptical trajectory was minimized due to disappearance of the first overtone. When the magnitude of the maximum excitation voltage was maintained at the same level for both PWM and sinusoidal excitation, PWM (DR=50%) excitation produced a greater vibration amplitude than sinusoidal excitation but resulted in more rapid saturation of a high-frequency power amplifier.

이중 주파수를 사용하는 펄스 플라즈마 특성에 관한 연구

  • Choe, Sang-Uk;Seo, Jin-Seok;Kim, Tae-Hyeong;Kim, Gyeong-Nam;Yeom, Geun-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.219.1-219.1
    • /
    • 2014
  • 전자소자 산업의 미세화 및 대형화에 따라 플라즈마 밀도, 전위, 온도, 균일도 등 과 같은 플라즈마 특성을 제어하는 것은 차세대 플라즈마 장치 개발에 있어 매우 중요한 요소라고 할 수 있다. 특히, 급격한 소자의 미세화에 따라 플라즈마 공정을 통해 발생할 수 있는 damage는 큰 issue가 되어 왔고, 많은 연구자들은 이를 해결하기 위해서 다각적인 노력을 진행해 왔다. 그중 높은 전자 온도는 높은 전자 에너지에 의해 공정 중 소자를 손상 시키는 주된 원인이라고 보고되고 있으며, 이에 대한 제어기술은 매우 중요하다고 할 수 있다. 본 연구에서는 서로 다른 두 개의 내/외측으로 나뉘어진 나선형 모양의 ICP 안테나를 이용 하여 연구를 진행하였다. 내측의 안테나에는 2 MHz를 연결 하였으며, 외측의 안테나에는 13.56 MHz를 연결 하였으며, 내/외측 안테나에 각각 pulse mode로 입력전력을 인가해 줌으로써 플라즈마의 특성을 관찰하였다. Pulse / CW (Continuous Wave) mode에 있어서 전자온도의 측정을 위해 emissive probe 를 이용하여 plasma potential과 floating potential을 측정하였으며, 이를 통하여 전자온도를 계산하여 구할 수 있었다. Duty ratio 및 pulsing frequency의 변화에 따른 전자온도의 변화를 확인 할 수 있었으며, 그에 따른 플라즈마 균일도를 ion saturation current를 측정함으로써 관찰할 수 있었다. 실제 식각 공정에 있어서 Pulsing 조건에 따른 식각 특성을 관찰하기 위해, SiO2, ACL (Amorphous Carbon Layer)에 대해 식각을 진행하였으며, 식각 메커니즘 분석을 위해 이온에너지 분포의 변화를 PSM (Plasma Sampling Mass-spectroscopy)을 이용하여 측정하였다.

  • PDF

Effects of EMLA Cream Application on Pain Perception and Pain Response of Children with Cancer During Implanted Venous Access Port Needle Insertion (EMLA크림 도포가 소아암환자의 피하매몰 중심정맥포트 바늘삽입 시 통증인지와 통증반응에 미치는 영향)

  • Seo, Hyun-Young;Kim, Young-Hae
    • Child Health Nursing Research
    • /
    • v.22 no.1
    • /
    • pp.21-28
    • /
    • 2016
  • Purpose: The purpose of this study was to identify effects of EMLA (Eutectic Mixture of Local Anesthetics) cream application on pain perception and pain response during insertion of implanted venous access port needle in children with cancer. Methods: From December 2010 to August 2011, at U university hospital, 20 patients scheduled for implanted venous access port needle insertion were recruited, and randomly assigned to receive either EMLA or a placebo cream 1 hour before the implanted venous access port needle insertion. While conducting needle insertion, changes in pulse and oxygen saturation on the pulse oxymeter monitor were measured and pain behavior reaction was also measured during needle insertion in the treatment room. After conducting needle insertion, self-reported pain reaction, and mothers' perception of the children's pain reaction were measured. Collected data were statistically processed using SPSS version 17.0 for Windows, and analyzed using descriptive statistics, t-test. Results: Children's self-reported degree of pain, degree of pain as perceived by mothers and pain behavior reaction decreased significantly in the EMLA application group compared with the placebo group. Conclusion: Findings indicate that application of EMLA cream is effective in relieving pain in these children during implanted venous access port needle insertion.

The Heart Rate Monitoring System using Inverted Photoplethysmography (반전 용적맥파 신호를 이용한 심박 모니터링 시스템)

  • Lee, Jun-Yeon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.17 no.3
    • /
    • pp.105-111
    • /
    • 2012
  • Photoplethysmogram is widely used to measure heart rate and arterial blood oxygen saturation in human. This paper describes implementation a photoplethysmography monitoring system that uses 780nm and 940nm length infrared light in radial artery. That system used combinations of 8 LEDs and 2 photoelectricities. When recorded on the skin over radial artery, the radial pulse wave was inverted. The mechanism of inverted pulse wave skin, which was reduced during systolic period and increase during diastolic period of the cardiac cycle. Through this system, we discovered optimal environments and combinations of sensors in both penetration type and reflection type. These results suggest that radial arterial wall way reflect infrared ray.

Development of the Alarm System for Preventing of the Lonely Death of Elderly (고령자 고독사 방지를 위한 알림 장치 개발)

  • Kim, Jong-Tae;Kong, Jung-Shik;Kim, Jin-Geol
    • Journal of IKEEE
    • /
    • v.20 no.1
    • /
    • pp.115-118
    • /
    • 2016
  • This paper presents development of the alarm system for preventing of the lonely death of the elderly. The population of the elderly people are growing rapidly. So, Some problems is caused by the senior citizen who lives alone, because of their death alone. In this paper, we propose the alarm system that can announce the state of the elderly who live alone. The system can check the pulse and oxygen saturation continuously. If biological signals are not good, the system can announce the information of the elderly to family and neighborhood. This system is verified by SpO2 Simulator.