• Title/Summary/Keyword: Saturation pulse

Search Result 192, Processing Time 0.023 seconds

$^1H$ NMR Estimation of Multi-Redox potentials of Cytochrome $c_3$ from Desulfovibrio vulgaris Hildenborough

  • 박장수;강신원;최성낙
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.4
    • /
    • pp.331-336
    • /
    • 1995
  • The macroscopic and microscopic redox potentials of tetrahemoprotein, cytochrome c3 from Desulfovibrio vulgaris(Hildenborough) (DvH) were estimated from 1H NMR and differential pulse polarography(DPP). Five sets of NMR resonances were confirmed by a redox titration. They represent cytochrome c3 molecules in five macroscopic redox states. The electron transfer in cytochrome c3 involves four consecutive one-electron steps. The saturation transfer method was used to determine the chemical shifts of eight heme methyl resonances in five different oxidation states. Thirty two microscopic redox potentials were estimated. The results showed the presence of a strong positive interaction between a pair of particular hemes. Comparing the results with those of Desulfovibrio vulgaris Miyazaki F (DvMF), it was observed that the two proteins resemble each other in overall redox pattern, but there is small difference in the relative redox potentials of four hemes.

A Study on MR Imaging Method for The Patient with Inserting Shoulder Joint Suture Anchor (견관절 삽입술을 시행한 환자의 자기 공명 영상법에 관한 연구)

  • Park, Eui-Cheol;Bae, Seok-Hwan;Ryu, Yeun-Chul;Park, Young-Joon;Kim, Yong-Gwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.513-519
    • /
    • 2021
  • Metallic suture anchors are very useful and common fixation devices that are inserted into the target bone to sustain the tendon of a patient with musculus supraspinatus tendon ruptures. On the other hand, the presence of a metallic material prosthesis, such as a metal suture anchor, causes severe MR imaging artifacts, including field distortion, signal loss, and failure of fat suppression. The difference in magnetic susceptibility between metal and other organic materials causes magnetic field distortion surrounding the prosthesis. The resulting magnetic field inhomogeneity makes the images with a lower signal-to-noise ratio and distortion. For a patient with a suture anchor implanted, MR imaging is the golden standard for determining the postoperative prognosis, and a fat-saturation sequence is one of the imaging methods most affected by metal-induced artifacts. In this study, three fat-saturation sequences were compared. Artifact quantification and contrast comparison between the supraspinatus tendon and the surrounding muscle were presented. The images obtained using the STIR pulse sequence showed fewer susceptibility artifacts and better visibility in the supraspinatus tendon and the tissue area. Therefore, the STIR sequence is the most appropriate fat-saturation imaging method for patients with a metallic prosthesis.

Association of Airflow Limitation and COPD Composite Index with Peripheral Oxygen Saturation in Patients with Chronic Obstructive Pulmonary Disease (만성폐쇄성폐질환자에서 기류제한 및 COPD 복합지수와 말초산소포화도의 연관성)

  • Jong Seong Lee;Jae Hoon Shin;Jin Ee Baek;Hyerim Son;Byung-soon Choi
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.34 no.1
    • /
    • pp.57-66
    • /
    • 2024
  • Objective: Chronic obstructive pulmonary disease (COPD) is characterized by progressive airflow obstruction that is only partly reversible, inflammation in the airways, and systemic effects. This study aimed to investigate the association between low peripheral oxygen saturation levels (SpO2), and composite indices predicting death in male patients with (COPD). Method: A total of 140 participants with post-bronchodilator FEV1/FVC ratio less than 0.7 were included. Three composite indices (ADO, DOSE, BODEx) were calculated using six variables such as age (A), airflow obstruction (O), body mass index (B), dyspnea (D), exacerbation history (E or Ex), and smoking status (S). Severity of airflow limitation was classified according to Global Initiative for Obstructive Lung Disease (GOLD) guidelines. SpO2 was measured by pulse oximetry, and anemia and iron deficiency were assessed based on blood hemoglobin levels and serum markers such as ferritin, transferrin saturation, or soluble transferrin receptor. Results: Participants with low SpO2 (<95%) showed significantly lower levels of %FEV1 predicted (p=0.020) and %FEV1/FVC ratio (p=0.002) compared to those with normal SpO2 levels. The mMRC dyspnea scale (p<0.001) and GOLD grade (p=0.002) showed a significant increase in the low SpO2 group. Receiver Operating Characteristic analysis revealed higher area under the curve for %FEV1 (p=0.020), %FEV1/FVC(p=0.002), mMRC dyspnea scale (p=0.001), GOLD grade (p=0.010), ADO (p=0.004), DOSE (p=0.002), and BODEx (p=0.011) in the low SpO2 group. Conclusion: These results suggest that low SpO2 levels are related to increased airflow limitation and the composite indices of COPD.

Effect of vapocoolant spray and EMLA cream upon DPT vaccination pain in infants (DPT 예방접종 시 냉각 스프레이와 EMLA의 통증경감 효과)

  • Jang, Gunja;Jeon, Eunyoung;Lee, Eunsil
    • Journal of the Korean Data and Information Science Society
    • /
    • v.25 no.4
    • /
    • pp.705-714
    • /
    • 2014
  • This study aimed at identifying the effect of vapocoolant spray and EMLA (eutectic mixture of local anesthetics) cream upon DPT (diphtheria-pertussis-tetanus)vaccineassociated injection pain in infants. A nonequivalent control group pretest-posttest design was used. The subjects were 49 infants, 19 of them for control group, 15 of them for vapocoolant group, and 15 infants for EMLA group. Pulse and oxygen saturation as pain indicators were measured before and after DPT vaccination. FLACC was also measured after vaccination. The data were collected between October 2009 and June 2010 and analyzed using SPSS WIN 20.0. EMLA group had significant a little changes in pulse (F=43.37, p <.001) and oxygen saturation (F=9.86, p=.003) compared to the control and vapocoolant group. But there was no difference in FLACC pain score among three groups. This results showed that EMLA cream is an effective agent for reducing DPT vaccination-associated pain. Therefore, EMLA cream can be used to reduce pain at public health centers and clinical settings.

The effect of acupuncture using tonification and sedation manipulation at LI4(Hegu) and KI7(Fuliu) on the control of sweating (한조절(汗調節) 혈위(穴位) 합곡(合谷) 복류(復溜)의 보사(補瀉)에 따른 침자(鍼刺)가 지한(止汗)에 미치는 영향(影響))

  • Song, Min-Sun;Choi, Chan-Hun;Youn, Dae-Hwan;Kim, Jee-Hyun;Na, Chang-Su
    • Korean Journal of Acupuncture
    • /
    • v.25 no.4
    • /
    • pp.133-145
    • /
    • 2008
  • Objectives : The purpose of this study was to exam the effectiveness of acupuncture using the tonification & sedation manipulation for LI4(Hegu) and KI7(Fuliu) which was known to promote sweating for lack sweating and inhibit for excessive sweating. Methods : The subject of this study was 60 people who agreed with participating. The participants were divided into 6 groups as control group without acupuncture, acupuncture group with needle inserted perpendicularly at LI4, KI7 without manipulation(AT-A), acupuncture group with needle inserted and twisted at LI4 using sedation technique and KI7 using tonificaton technique(AT-B), acupuncture group with needle inserted and twisted at LI4 using tonificaton technique and KI7 using sedation technique(AT-C), acupuncture group with needle inserted and twisted at LI4 and KI7 using tonificaton technique(AT-D) and acupuncture group with needle inserted and twisted at LI4 and KI7 using sedation technique(AT-E). We obtained baseline data at a stable condition with the temperature of $25^{\circ}C$. After having the participant stay at $40^{\circ}C$ for 10 minute and treated with acupuncture for 10 minute, we measured the parameters such as sweating rate, water content in subcutaneous, water content in skin surface, systolic blood pressure, diastolic blood pressure, pulse rate, oxygen saturation and body temperature. Results : After the tonification & sedation manipulation at LI4 and KI7, the sweating rate was significantly decreased in AT-B, AT-D and AT-E groups. The water contents in skin surface was significantly decreased in AT-B and AT-E groups. The water contents in subcutaneous was significantly decreased in AT-B, AT-C, AT-D and AT-E groups. However, there were no significant changes in systolic blood pressure, diastolic blood pressure, pulse rate, oxygen saturation and body temperature. Conclusions : Acupuncture at LI4 and KI7 is effective in controling sweating, and the effect varies according to the tonification & sedation manipulation technique.

  • PDF

Signl processing method and diagnostic algorithm for arterial oxygen-saturation measument (산소포화도 측정을 위한 신호처리방법 및 계산 알고리즘)

  • 김수진;황돈연;전계진;이종연;정성규;윤길원
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.6
    • /
    • pp.452-456
    • /
    • 2000
  • A measurement unit and signal processing algorithm have been developed for predicting arterial oxygen saturation noninvasively. The measurement set-up was composed of a probe including light source and photodetector, optical signal processing section, LED driving circuit, PC interface software for data acquisition and data processing software. Light from the LED's was irradiated onto the finger nail bed and transmitted light was measured at different wavelengths. An effective baseline correction method was developed and measured data were analyzed by using various data processing methods and prediction algOlithms. For performance evaluation, a pulse oximeter simulator (Bio- Tek Instrument Inc.) was used as reference. The best performance in terms of the correlation coefficient and the standard deviation was obtained under the following conditions; when the arterial signals were computed in terms of area rather than peak-valley difference, and when the algorithm calculating by $In(I_p/I_v)/I_{avr}$ value for pulsation waveform was used. In in vivo test, prediction was improved when the developed baseline correction method was used. In addition, wavelengths of 660 nm and 940 nm provided better linearity and precision than wavelengths of 660 nm and 805 nm. 05 nm.

  • PDF

A Study on Optimized MRI Fat-Saturation Technique for Brachial Plexus Patients : Focused on SPAIR and STIR Fat-Saturation (상완신경총 환자에서 최적의 자기공명영상 지방소거 기법에 관한 연구 : SPAIR, STIR 지방소거 중심으로)

  • Goo, Eunhoe
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.5
    • /
    • pp.271-278
    • /
    • 2014
  • The purpose of this study is to know optimized fat suppression techniques for brachial plexus compared with STIR and SPAIR T1, T2 techniques. A total of 30 normal volunteers without brachial plexus disease were studied on a 3.0 T MRI scanner. As an analytical method, SNR, CNR, 4-point grading scale were evaluated by using three pulse sequences. As a quantitative analysis, the SNR, CNR for SPAIR T1 technique provided high value in branchial plexus roots (03.07, -2.25), branchial plexus trunks(06.70, 36.31)(p<0.05). As a qualitative Analysis, The visibility for delineation of brachial plexus, fat suppression, artifact was significantly better on SPAIR T1(3.2, 3.6, 3.4) technique(p<0.05).

Effect of Submucosal Midazolam on Percutaneous Saturation Percentage of Oxygen ($SpO_2$), End-tidal Carbon Dioxide ($EtCO_2$) and Physiologic Response When Combined with Chloral Hydrate, Hydroxyzine and Nitrous Oxide Sedation (구강 점막 하 주입 Midazolam과 경구 투여한 Chloral Hydrate의 용량에 따른 산소 포화도 및 생징후 변화에 대한 비교 연구)

  • Yu, Ji-Hye;Kim, Yun-Hee;Jung, Sang-Hyuk;Baek, Kwang-Woo
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.6 no.2 s.11
    • /
    • pp.89-97
    • /
    • 2006
  • Background: The aim of this study was to examine the difference of $SpO_2$, PR, $EtCO_2$, RR with submucosal injection of midazolam to oral chloral hydrate and hydroxyzine for pediatric patients Methods: Thirty two sedation cases were performed in this study. Patients were randomly classified into one group taking oral CH (60 mg/kg). hydroxyzine (1 mg/kg) and submucosal injection of midazolam (0.1 mg/kg) and the other group recieving oral CH (50 mg/kg), hydroxyzine (1 mg/kg) and submucosal injection of midazolam (0.2 mg/kg). For evaluating the depth of sedation. data including saturation percentage of oxygen ($SpO_2$), pulse rate (PR), end-tidal carbon dioxide ($EtCO_2$), respiratory rate (RR) and the behavior scale were checked every 2 minutes and were collected for only 40 minutes from the beginning of treatment and were analyzed using Two independent sample T-test. Results: Analysis showed no significant difference in the mean $SpO_2$, PR, $EtCO_2$, RR during sedation between two groups (P > 0.05). The values of $SpO_2$, PR, $EtCO_2$ and RR for both groups remained within the normal values. Conclusions: The results of this present study indicate that combination of oral CH, hydroxyzine, nitrous oxide gas inhalation and submucosal injection of midazolam improved the sedation quality without compromising safety.

  • PDF

Cerebral Oxygenation during Apnea in Preterm Infants: Effects of Accompanying Peripheral Oxygen Desaturation

  • Choi, Seo Hee;Lee, Juyoung;Nam, Soo Kyung;Jun, Yong Hoon
    • Neonatal Medicine
    • /
    • v.28 no.1
    • /
    • pp.14-21
    • /
    • 2021
  • Purpose: Premature infants have immature respiratory control and cerebral autoregulation. We aimed to investigate changes in cerebral oxygenation during apnea with and without peripheral oxygen desaturation in premature infants. Methods: This prospective observational study was conducted at Inha University Hospital. Near-infrared spectroscopy (NIRS)-monitored regional cerebral oxygen saturation (rScO2) and pulse oximeter-monitored peripheral oxygen saturation (SpO2) were assessed during the first week of life in 16 stable, spontaneously breathing preterm infants. Apneic episodes that lasted for ≥20 seconds or were accompanied by desaturation or bradycardia were included for analysis. The average rScO2 value during the 5-minute prior to apnea (baseline), the lowest rScO2 value following apnea (nadir), the time to recover to baseline (recovery time), the area under the curve (AUC), and the overshoot above the baseline after recovery were analyzed. Results: The median gestational age and birth weight of the infants were 29.2 weeks (interquartile range [IQR], 28.5 to 30.5) and 1,130 g (IQR, 985 to 1,245), respectively. A total of 73 apneic episodes were recorded at a median postnatal age of 2 days (IQR, 1 to 4). The rScO2 decreased significantly following apneic episodes regardless accompanied desaturation. There were no differences in baseline, nadir, or overshoot rScO2 between the two groups. However, the rScO2 AUC for apnea with desaturation was significantly higher than that for apnea without desaturation. Conclusion: Cerebral oxygenation can significantly decrease during apnea, especially when accompanied by reduced SpO2. These results add the evidence for the clinical utility of NIRS in monitoring premature infants.

Real-time Vital Signs Measurement System using Facial Image Data (안면 이미지 데이터를 이용한 실시간 생체징후 측정시스템)

  • Kim, DaeYeol;Kim, JinSoo;Lee, KwangKee
    • Journal of Broadcast Engineering
    • /
    • v.26 no.2
    • /
    • pp.132-142
    • /
    • 2021
  • The purpose of this study is to present an effective methodology that can measure heart rate, heart rate variability, oxygen saturation, respiration rate, mental stress level, and blood pressure using mobile front camera that can be accessed most in real life. Face recognition was performed in real-time using Blaze Face to acquire facial image data, and the forehead was designated as ROI (Region Of Interest) using feature points of the eyes, nose, and mouth, and ears. Representative values for each channel of the ROI were generated and aligned on the time axis to measure vital signs. The vital signs measurement method was based on Fourier transform, and noise was removed and filtered according to the desired vital signs to increase the accuracy of the measurement. To verify the results, vital signs measured using facial image data were compared with pulse oximeter contact sensor, and TI non-contact sensor. As a result of this work, the possibility of extracting a total of six vital signs (heart rate, heart rate variability, oxygen saturation, respiratory rate, stress, and blood pressure) was confirmed through facial images.