• Title/Summary/Keyword: Saturation field

Search Result 545, Processing Time 0.029 seconds

Efficient Search Method of Deperming Protocol for Magnetic Silence of Vessel

  • Kim, Jong-Wang;Kim, Sang-Hyun;Kim, Ji-ho;Lee, Hyang-Beom;Chung, Hyun-Ju
    • Journal of Magnetics
    • /
    • v.22 no.1
    • /
    • pp.85-92
    • /
    • 2017
  • This research is proposed with the efficient searching method of deperming protocol for magnetic silence. The deperming protocol has been changed depending on the initial magnetic field, the final magnetic field, and the shot number, so deciding parameter is highly important. Therefore, in this paper, the value of the initial magnetic field is supposed to be fixed to that of the saturation field, and excluding the initial magnetic field in the variable, the deperming protocol has been analyzed depending on the final magnetic field and the change of the shot number. In the result of this experiment, the final magnetic field gets high performance to the reverse of the direction of the initial magnetization, and it is resulted that the shot number inverse proportion to the size of the final magnetic field.

Analysis of the Output Characteristics of IGZO TFT with Double Gate Structure (더블 게이트 구조 적용에 따른 IGZO TFT 특성 분석)

  • Kim, Ji Won;Park, Kee Chan;Kim, Yong Sang;Jeon, Jae Hong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.33 no.4
    • /
    • pp.281-285
    • /
    • 2020
  • Oxide semiconductor devices have become increasingly important because of their high mobility and good uniformity. The channel length of oxide semiconductor thin film transistors (TFTs) also shrinks as the display resolution increases. It is well known that reducing the channel length of a TFT is detrimental to the current saturation because of drain-induced barrier lowering, as well as the movement of the pinch-off point. In an organic light-emitting diode (OLED), the lack of current saturation in the driving TFT creates a major problem in the control of OLED current. To obtain improved current saturation in short channels, we fabricated indium gallium zinc oxide (IGZO) TFTs with single gate and double gate structures, and evaluated the electrical characteristics of both devices. For the double gate structure, we connected the bottom gate electrode to the source electrode, so that the electric potential of the bottom gate was fixed to that of the source. We denote the double gate structure with the bottom gate fixed at the source potential as the BGFP (bottom gate with fixed potential) structure. For the BGFP TFT, the current saturation, as determined by the output characteristics, is better than that of the conventional single gate TFT. This is because the change in the source side potential barrier by the drain field has been suppressed.

Development of a predictive functional control approach for steel building structure under earthquake excitations

  • Mohsen Azizpour;Reza Raoufi;Ehsan Kazeminezhad
    • Earthquakes and Structures
    • /
    • v.25 no.3
    • /
    • pp.187-198
    • /
    • 2023
  • Model Predictive Control (MPC) is an advanced control approach that uses the current states of the system model to predict its future behavior. In this article, according to the seismic dynamics of structural systems, the Predictive Functional Control (PFC) method is used to solve the control problem. Although conventional PFC is an efficient control method, its performance may be impaired due to problems such as uncertainty in the structure of state sensors and process equations, as well as actuator saturation. Therefore, it requires the utilization of appropriate estimation algorithms in order to accurately evaluate responses and implement actuator saturation. Accordingly, an extended PFC is presented based on the H-ifinity (H∞) filter (HPFC) while considering simultaneously the saturation actuator. Accordingly, an extended PFC is presented based on the H-ifinity (H∞) filter (HPFC) while considering the saturation actuator. Thus, the structural responses are formulated by two estimation models using the H∞ filter. First, the H∞ filter estimates responses using a performance bound (𝜃). Second, the H∞ filter is converted into a Kalman filter in a special case by considering the 𝜃 equal to zero. Therefore, the scheme based on the Kalman filter (KPFC) is considered a comparative model. The proposed method is evaluated through numerical studies on a building equipped with an Active Tuned Mass Damper (ATMD) under near and far-field earthquakes. Finally, HPFC is compared with classical (CPFC) and comparative (KPFC) schemes. The results show that HPFC has an acceptable efficiency in boosting the accuracy of CPFC and KPFC approaches under earthquakes, as well as maintaining a descending trend in structural responses.

COLLINEARITY AND SPIN FREEZING

  • Vincze, I.;Kemeny, T.
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.5
    • /
    • pp.343-350
    • /
    • 1995
  • An overview will be given on recent Mossbauer and magnetization investigation of the applied field dependence of the magnetic properties of typical systems without strong magnetic anisotropy and showing the absence of magnetic saturation in high fields (including iron-rich spin glass (amorphous $Fe_{93}Zr_{7}$, soft ferromagnets (amorphous $Fe_{88}Zr_{12}$, $Fe_{70}Ni_{20}Zr_{10}$ and $Fe_{88}B_{12}$) and pure Fe). The results emphasize that shape anisotropy due to surface irregularities causes misalignment between the magnetization and the applied field in the otherwise collinear magnetic structure.

  • PDF

A Study on MR Imaging Method for The Patient with Inserting Shoulder Joint Suture Anchor (견관절 삽입술을 시행한 환자의 자기 공명 영상법에 관한 연구)

  • Park, Eui-Cheol;Bae, Seok-Hwan;Ryu, Yeun-Chul;Park, Young-Joon;Kim, Yong-Gwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.4
    • /
    • pp.513-519
    • /
    • 2021
  • Metallic suture anchors are very useful and common fixation devices that are inserted into the target bone to sustain the tendon of a patient with musculus supraspinatus tendon ruptures. On the other hand, the presence of a metallic material prosthesis, such as a metal suture anchor, causes severe MR imaging artifacts, including field distortion, signal loss, and failure of fat suppression. The difference in magnetic susceptibility between metal and other organic materials causes magnetic field distortion surrounding the prosthesis. The resulting magnetic field inhomogeneity makes the images with a lower signal-to-noise ratio and distortion. For a patient with a suture anchor implanted, MR imaging is the golden standard for determining the postoperative prognosis, and a fat-saturation sequence is one of the imaging methods most affected by metal-induced artifacts. In this study, three fat-saturation sequences were compared. Artifact quantification and contrast comparison between the supraspinatus tendon and the surrounding muscle were presented. The images obtained using the STIR pulse sequence showed fewer susceptibility artifacts and better visibility in the supraspinatus tendon and the tissue area. Therefore, the STIR sequence is the most appropriate fat-saturation imaging method for patients with a metallic prosthesis.

Analysis and Comparison of a Permanent-Magnet DC Motor with a Field-Winding DC Motor

  • Kiyoumarsi, Arash
    • Journal of Electrical Engineering and Technology
    • /
    • v.4 no.3
    • /
    • pp.370-376
    • /
    • 2009
  • The influence of magnetic saturation on electromagnetic field distribution in both a permanent-magnet direct-current (PMDC) motor and a field-winding (wound-field) direct-current (FWDC) motor, with the same output mechanical power, has been studied. In this paper, an approximate analytical method and time-stepping Finite Element Method (FEM) are used for prediction of Back-EMF and electromagnetic torque. No-load and rotor-lucked conditions, according to experimental measurements, and the FEM and analytical method studies of the motors have been considered. A sensitivity analysis has also been successfully accomplished on the major design parameters that affect motor performance. At last, these two DC motors are compared, in spite of their differences, on the basis of measured output characteristics.

Characteristics of Ferroelectric-Gate MFISFET Device Behaving to NDRO Configuration (NDRD 방식의 강유전체-게이트 MFSFET소자의 특성)

  • 이국표;강성준;윤영섭
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.1
    • /
    • pp.1-10
    • /
    • 2003
  • Device characteristics of the Metal-Ferroclecric-Semiconductor FET(MFSFET) are simulated in this study. The field-dependent polarization model and the square-law FET model are employed in our simulation. C-V$_{G}$ curves generated from our MFSFET simulation exhibit the accumulation, the depletion and the inversion regions clearly. The capacitance, the subthreshold and the drain current characteristics as a function of gate bias exhibit the memory windows are 1 and 2 V, when the coercive voltages of ferroelectric are 0.5 and 1 V respectively. I$_{D}$-V$_{D}$ curves are composed of the triode and the saturation regions. The difference of saturation drain currents of the MFSFET device at the dual threshold voltages in I$_{D}$-V$_{D}$ curve is 1.5, 2.7, 4.0, and 5.7 ㎃, when the gate biases are 0, 0.1, 0.2 and 0.3V respectively. As the drain current is demonstrated after time delay, PLZT(10/30/70) thin film shows excellent reliability as well as the decrease of saturation current is about 18 % after 10 years. Our simulation model is expected to be very useful in the estimation of the behaviour of MFSFET devices.T devices.

Prediction method of slope hazards using a decision tree model (의사결정나무모형을 이용한 급경사지재해 예측기법)

  • Song, Young-Suk;Chae, Byung-Gon;Cho, Yong-Chan
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.1365-1371
    • /
    • 2008
  • Based on the data obtained from field investigation and soil testing to slope hazards occurrence section and non-occurrence section in gneiss area, a prediction technique was developed by the use of a decision tree model. The slope hazards data of Seoul and Kyonggi Province were 104 sections in gneiss area. The number of data applied in developing prediction model was 61 sections except a vacant value. The statistical analyses using the decision tree model were applied to the entrophy index. As the results of analyses, a slope angle, a degree of saturation and an elevation were selected as the classification standard. The prediction model of decision tree using entrophy index is most likely accurate. The classification standard of the selected prediction model is composed of the slope angle, the degree of saturation and the elevation from the first choice stage. The classification standard values of the slope angle, the degree of saturation and elevation are $17.9^{\circ}$, 52.1% and 320m, respectively.

  • PDF