• Title/Summary/Keyword: Salt removal

Search Result 287, Processing Time 0.03 seconds

Preparation of Carbon Electrodes Using Activated Carbon Fibers and Their Performance Characterization for Capacitive Deionization Process (활성탄소섬유를 이용한 탄소전극의 제조 및 축전식 탈염공정에서의 성능평가)

  • Park, Cheol Oh;Oh, Ju Seok;Rhim, Ji Won
    • Membrane Journal
    • /
    • v.28 no.4
    • /
    • pp.271-278
    • /
    • 2018
  • In this study, the carbon electrodes using activated carbon fibers (ACFs) were prepared for the capacitive deionization process. The Polyvinylidene fluoride (PVDF) was used as the binder and the mixed ACFs with proper solvent was cast on the commercial graphite sheets to prepare the carbon electrodes. At this moment, the different particle sizes of ACFs were applied and the mixing ratio of solvent, PVDF and ACFs, 80 : 2 : 18 and 80 : 5 : 15, were used for the electrode preparation. Then their salt removal efficiencies were characterized under the various operating conditions, adsorption potential and time, desorption potential and time, concentration of feed NaCl solution and flow rate as well. Typically, the salt removal efficiency of 53.6% were obtained at the particle size below $32{\mu}m$, mixing ratio 80 : 2 : 18, adsorption 1.2 V and 3 min, desorption -0.1V and 1 min, and 15 mL/min flow rate of NaCl 100 mg/L.

Improvement of Capacitive Deionization Performance by Coating Quaternized Poly(phenylene oxide) (4급화 폴리페닐렌 옥시드 코팅을 통한 축전식 탈이온 성능 향상)

  • Kim, Do-Hyeong;Kang, Moon-Sung
    • Membrane Journal
    • /
    • v.24 no.4
    • /
    • pp.332-339
    • /
    • 2014
  • In this study, an anion-exchange ionomer solution was developed by employing poly(2,6-dimethyl-1,4-phenylene oxide) (PPO) as the base material for the improvement of the capacitive deionization (CDI) performances. It was found that prepared quaternized PPO (QPPO) exhibited excellent ion conductivity superior to that of a commercial anion-exchange membrane (AMX, Astom Corp., Japan) and also the electrochemical properties were shown to be comparable with each other. The CDI tests were conducted by employing the porous carbon electrode coated with the ionomer solution and the result showed the high salt removal efficiency of about 94.9%. By comparing the desalination efficiencies in conventional CDI, membrane CDI (MCDI) with a commercial anion-exchange membrane, and coated CDI (CCDI) employing the porous carbon electrode coated with QPPO, it was confirmed that CCDI shows the high salt removal performance improved by 52.1% and 18.3% compared with those of conventional CDI and MCDI, respectively.

Preliminary design and assessment of a heat pipe residual heat removal system for the reactor driven subcritical facility

  • Zhang, Wenwen;Sun, Kaichao;Wang, Chenglong;Zhang, Dalin;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.3879-3891
    • /
    • 2021
  • A heat pipe residual heat removal system is proposed to be incorporated into the reactor driven subcritical (RDS) facility, which has been proposed by MIT Nuclear Reactor Laboratory for testing and demonstrating the Fluoride-salt-cooled High-temperature Reactor (FHR). It aims to reduce the risk of the system operation after the shutdown of the facility. One of the main components of the system is an air-cooled heat pipe heat exchanger. The alkali-metal high-temperature heat pipe was designed to meet the operation temperature and residual heat removal requirement of the facility. The heat pipe model developed in the previous work was adopted to simulate the designed heat pipe and assess the heat transport capability. 3D numerical simulation of the subcritical facility active zone was performed by the commercial CFD software STAR CCM + to investigate the operation characteristics of this proposed system. The thermal resistance network of the heat pipe was built and incorporated into the CFD model. The nominal condition, partial loss of air flow accident and partial heat pipe failure accident were simulated and analyzed. The results show that the residual heat removal system can provide sufficient cooling of the subcritical facility with a remarkable safety margin. The heat pipe can work under the recommended operation temperature range and the heat flux is below all thermal limits. The facility peak temperature is also lower than the safety limits.

Use of Li-K-Cd Alloy to Remove MCl3 in LiCl-KCl Eutectic Salt (Li-K-Cd 합금을 이용한 LiCl-KCl 용융염에서 금속염화물의 제거)

  • Kim, Gha-Young;Kim, Tack-Jin;Jang, Junhyuk;Kim, Si-Hyung;Lee, Chang Hwa;Lee, Sung-Jai
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.3
    • /
    • pp.309-313
    • /
    • 2018
  • In this study, we prepared Li-K-Cd alloy, which meets the requirement of eutectic ratio of Li:K, to maintain the operating temperature of the drawdown process at $500^{\circ}C$ and to achieve the reuse of LiCl-KCl molten salt. The prepared Li-K-Cd alloys were added to LiCl-KCl salt bearing U and Nd at $500^{\circ}C$ to investigate the removal of $UCl_3$ in the salt. The reduction of $UCl_3$ in the salt was examined by measuring the OCP value of salt and analyzing the salt composition by ICP-OES. Reduction was also visually confirmed by change of salt color from dark purple to white. The experimental results reveal that the prepared Li-K-Cd alloy has reductive extractability for $UCl_3$ in salt. By improving the preparation method, the Li-K-Cd alloy can be applied to the drawdown process.

Effect of pH and Initial Phosphorus Concentration on Phosphorus Removal by Aluminum Salts (알루미늄염에 의한 인 제거 시 pH와 초기 인 농도의 영향)

  • Park, Jeongwon;Kwak, Hyoeun;Min, Sojin;Chung, Hyung-Keun;Park, Pyung-Kyu
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.2
    • /
    • pp.123-130
    • /
    • 2016
  • Phosphorus (P) removal by aluminum sulfate solution was investigated with varying pH and initial P concentrations. P removal was the highest at around pH 6. The pH range where P removal occurred was slightly wider at higher initial P concentrations. Compared to theoretical calculations, it was confirmed that $AlPO_4$ precipitation was the main reason for P removal at low pH. At high pH, where there should be no $AlPO_4$ precipitates, the P removal by adsorption of amorphous $Al(OH)_3$ precipitates was experimentally observed. The P removal by adding amorphous $Al(OH)_3$ precipitates prepared before the adsorption experiments, however, was lower than that by injecting aluminum sulfate solution because the prepared precipitates became larger, leading to less specific surface area available for adsorption. Ions other than sulfate had little influence on P removal.

Noise Removal using Modified Switching Filter in Mixed Noise Environments (복합잡음 환경에서 변형된 스위칭 필터를 이용한 잡음 제거)

  • Kwon, Se-Ik;Kim, Nam-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.6
    • /
    • pp.1215-1220
    • /
    • 2016
  • As society has developed rapidly toward a highly advanced digital information age, a multimedia communication service for acquisition, transmission and storage of image data as well as voice has being commercialized. However, image data is always corrupted by various noises during image processing, so researches for removing noises have been continued until now. There are diverse types of noise on the image including salt and pepper noise, AWGN, and mixed noise. Hence, the filter algorithm for the image recovery was proposed that salt and pepper noise was processed by linear interpolation, histogram weighted values and median filter after defining the noise to lessen the impact of mixed noise added in the image, and AWGN was processed by the pixel information of local mask establishing the weighted values in this study. In addition, the algorithm was compared with the conventional methods for objectively and used the PSNR(peak signal to noise ratio) as the basis of the determination.

Desalinization Effect of Off-season Crop Cultivation in Long-term Oriental Melon Cultivated Plastic Film House Soils (휴경기 후작물 재배에 의한 참외 장기연작 비닐하우스 토양의 제염 효과)

  • Byeon, Il-Su;Chung, Jong-Bae
    • Korean Journal of Environmental Agriculture
    • /
    • v.34 no.4
    • /
    • pp.253-259
    • /
    • 2015
  • BACKGROUND: During the off-season, the cultivation of Chinese cabbage and water dropwort is often used to desalinize plastic film house soils. The objective of this study was to verify the effect of double-cropping systems on the salt removal in oriental melon cultivated plastic film house soils.METHODS AND RESULTS: Electrical conductivity (EC) and soluble salt contents were measured in soils collected from plastic film houses of oriental melon cultivation before and after the off-season crop cultivation. Also the same measurements were performed in the next oriental melon season to estimate the desalinization effect of double-cropping systems. During the cultivation of Chinese cabbage under open-field condition, ECeof surface soil was reduced from 6.0 to 0.8 dS/m. Double-cropping of water dropwort in flooded soil was also efficient in removing the salts accumulated during oriental melon cultivation. In the house soils where salts were removed during the off-season crop cultivation, soil ECewas maintained below 3 dS/m during the next oriental melon cultivation season.CONCLUSION: The off-season cropping under open-field or flooded condition was effective in desalinization of plastic film house soils. Since the salt removal effect is not expected to last for several years, the double-cropping system should be introduced every season to maintain soil EC below the critical level.

Salt & Pepper Noise Removal using Bilinear Interpolation (이중 선형 보간법을 이용한 Salt & Pepper 잡음 제거)

  • Ko, You-Hak;Kwon, Se-Ik;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.343-345
    • /
    • 2017
  • In digital era image processing has been utilized in a variety of media such as TV, camera and smart phone. However, in the process of analyzing, recognizing, and processing image data, deterioration occurs due to various causes and Salt & Pepper noise occurs. Typical methods for removing such noise include SMF, CWMF, and SWMF. However, existing methods have a somewhat poor noise canceling characteristic in Salt & Pepper noise environment. Therefore, in this paper, we propose an algorithm to remove Salt & Pepper noise effectively by using bilinear interpolation method and median filter according to noise density of local mask. And using the PSNR(Peak Signal to Noise Ratio) it compared to the existing methods and their performance in order to determine the performance of the proposed method.

  • PDF

A Study on the Cell Structure for Capacitive Deionization System (축전식 탈염 시스템을 위한 셀 구조에 관한 연구)

  • Lee, Ju-Young;Seo, Seok-Jun;Park, Jung-Woo;Moon, Seung-Hyeon
    • Korean Chemical Engineering Research
    • /
    • v.48 no.6
    • /
    • pp.791-794
    • /
    • 2010
  • This study presents channel design of a CDI stack to achieve high removal efficiency in a large scale by applying parallel flow structure with a concentrated stream. The flow pattern in the stack was simulated by COMSOL Multiphysics program. To prove the salt removal performance, a unit cell and 20 cell stacks were tested at a flow rate condition of 18 ml/min and 360 ml/min, respectively. The removal efficiencies of the unit cell and the 20 cell stacks were obtained as 70.8 % and 75.6 %, respectively, with 100 mg/L sodium chloride solution. During the operation of cell test, water pressures of unit cell and 20 cell pair stack maintained in the ranges of 1.1 psi and 1.3~1.5 psi, respectively. It was demonstrated that the parallel cell structure with two concentrated streams can be employed in a large scale CDI for salt removal.

간척지, 해안가 근처의 농업용수 공급을 위한 기수담수 시스템 연구

  • Hong, Min
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.57 no.4
    • /
    • pp.16-24
    • /
    • 2015
  • Desalination technology is a process to remove salt from water. There are three classified In accordance with the concentration of salt The concentration of sea water 15,000~50,000mg/l, brackish water 1,500~15,000mg/l, desalination less than 500mg/l.. In general, salt to remove for using a pre-treatment UF filter, but this study is new pre-treatment technology RO Membrane process technology Suspended particulate matter is said most were treated at the pre-treatment equipment, wheat affluent particulate material was removed from the MF filter. Influent SS 16.2mg /l The treatment was effective in treatment 0.05mg /l of 99% is removed. COD is reduced to 60% in the pre-treatment device, after treatment was reduced to 30% RO membrane. Influent COD 10.2mg/l treatment was removed 1.9mg/l. The removal rate is 81.9%. Desalination removes the ionic substances in the RO Membrane. Influent EC $978.8{\mu}s/cm$ and treatment showed a result of $18.7{\mu}s/cm$.