DOI QR코드

DOI QR Code

Preliminary design and assessment of a heat pipe residual heat removal system for the reactor driven subcritical facility

  • Zhang, Wenwen (School of Nuclear Science and Technology, Xi'an Jiaotong University) ;
  • Sun, Kaichao (Massachusetts Institute of Technology, Nuclear Reactor Laboratory) ;
  • Wang, Chenglong (School of Nuclear Science and Technology, Xi'an Jiaotong University) ;
  • Zhang, Dalin (School of Nuclear Science and Technology, Xi'an Jiaotong University) ;
  • Tian, Wenxi (School of Nuclear Science and Technology, Xi'an Jiaotong University) ;
  • Qiu, Suizheng (School of Nuclear Science and Technology, Xi'an Jiaotong University) ;
  • Su, G.H. (School of Nuclear Science and Technology, Xi'an Jiaotong University)
  • Received : 2020.10.12
  • Accepted : 2021.06.05
  • Published : 2021.12.25

Abstract

A heat pipe residual heat removal system is proposed to be incorporated into the reactor driven subcritical (RDS) facility, which has been proposed by MIT Nuclear Reactor Laboratory for testing and demonstrating the Fluoride-salt-cooled High-temperature Reactor (FHR). It aims to reduce the risk of the system operation after the shutdown of the facility. One of the main components of the system is an air-cooled heat pipe heat exchanger. The alkali-metal high-temperature heat pipe was designed to meet the operation temperature and residual heat removal requirement of the facility. The heat pipe model developed in the previous work was adopted to simulate the designed heat pipe and assess the heat transport capability. 3D numerical simulation of the subcritical facility active zone was performed by the commercial CFD software STAR CCM + to investigate the operation characteristics of this proposed system. The thermal resistance network of the heat pipe was built and incorporated into the CFD model. The nominal condition, partial loss of air flow accident and partial heat pipe failure accident were simulated and analyzed. The results show that the residual heat removal system can provide sufficient cooling of the subcritical facility with a remarkable safety margin. The heat pipe can work under the recommended operation temperature range and the heat flux is below all thermal limits. The facility peak temperature is also lower than the safety limits.

Keywords

References

  1. S.M. Bragg-Sitton, Analysis of Space Reactor System Components: Investigation through Simulation and Non-nuclear Testing, Diss. University of Michigan, United States, 2004.
  2. M. Houts, L. Kos, D. Poston, January). Potential operating orbits for fission electric propulsion systems driven by the SAFE-400, in: AIP Conference Proceedings, vol. 608, American Institute of Physics, 2002, pp. 717-721. No. 1.
  3. M.S. El-Genk, J.M.P. Tournier, "SAIRS"-scalable AMTEC integrated reactor space power system, Prog. Nucl. Energy 45 (1) (2004) 25-69. https://doi.org/10.1016/j.pnucene.2004.08.002
  4. M.A. Gibson, L.S. Mason, C.L. Bowman, D.I. Poston, P.R. McClure, J. Creasy, C. Robinson, Development of NASA's Small Fission Power System for Science and Human Exploration, 2015.
  5. D.I. Poston, The heatpipe-operated Mars exploration reactor (HOMER), AIP Conference Proceedings 552 (2001). No. 1. AIP.
  6. A. Bushman, et al., The Martian Surface Reactor: an Advanced Nuclear Power Station for Manned Extraterrestrial Exploration, MIT-NSA-TR-003, 2004.
  7. J.D. Bess, A Basic LEGO Reactor Design for the Provision of Lunar Surface Power. No. INL/CON-08-14353, Idaho National Laboratory, United States, 2008.
  8. E. Greenspan, Solid Core Heat-Pipe Nuclear Battery Type Reactor, University of California, United States, 2008. No. DOE/ID/14706).
  9. A. Maioli, et al., Modernization of Technical Requirements for Licensing of Advanced Non-light Water Reactors Westinghouse eVinciTM Micro-reactor Licensing Modernization Project Demonstration, Southern Company, United States, 2019.
  10. A. Faghri, Heat pipes: review, opportunities and challenges, Frontiers in Heat Pipes (FHP) 5 (1) (2014).
  11. A.L. Qualls, B.R. Betzler, N.R. Brown, J.J. Carbajo, M.S. Greenwood, R. Hale, A.J. Wysocki, Preconceptual design of a fluoride high temperature salt-cooled engineering demonstration reactor: motivation and overview, Ann. Nucl. Energy 107 (2017) 144-155. https://doi.org/10.1016/j.anucene.2016.11.021
  12. N.R. Brown, B.R. Betzler, J.J. Carbajo, A.J. Wysocki, M.S. Greenwood, C. Gentry, A.L. Qualls, Preconceptual design of a fluoride high temperature salt-cooled engineering demonstration reactor: core design and safety analysis, Ann. Nucl. Energy 103 (2017) 49-59. https://doi.org/10.1016/j.anucene.2017.01.003
  13. R.R. Romatoski, L.W. Hu, Fluoride-salt-cooled high-temperature test reactor thermal-hydraulic licensing and uncertainty propagation analysis, Nucl. Technol. 205 (11) (2019) 1495-1512. https://doi.org/10.1080/00295450.2019.1610686
  14. K. Sun, L.W. Hu, C. Forsberg, Neutronics feasibility of an MIT reactor-driven subcritical facility for the fluoride-salt-cooled high-temperature reactor, Int. J. Energy Res. 41 (14) (2017) 2248-2257. https://doi.org/10.1002/er.3786
  15. T.H. Newton Jr., M.S. Kazimi, E.E. Pilat, Development of a low-enricheduranium core for the MIT reactor, Nucl. Sci. Eng. 157 (3) (2007) 264-279. https://doi.org/10.13182/NSE07-A2727
  16. K. Sun, L.W. Hu, C. Forsberg, Neutronic design features of a transportable fluoride-salt-cooled high-temperature reactor, J. Nucl. Eng. Radiat. Sci. 2 (3) (2016).
  17. W. Zhang, D. Zhang, W. Tian, S. Qiu, G.H. Su, Thermal-hydraulic analysis of the improved TOPAZ-II power system using a heat pipe radiator, Nucl. Eng. Des. 307 (2016) 218-233. https://doi.org/10.1016/j.nucengdes.2016.07.020
  18. Z.J. Zuo, A. Faghri, A network thermodynamic analysis of the heat pipe, Int. J. Heat Mass Tran. 41 (11) (1998) 1473-1484. https://doi.org/10.1016/S0017-9310(97)00220-2
  19. V. Gnielinski, New equations for heat and mass transfer in turbulent pipe and channel flow, Int. Chem. Eng. 16 (2) (1976) 359-368.
  20. D. Taler, Experimental determination of correlations for mean heat transfer coefficients in plate fin and tube heat exchangers, Arch. Therm. 33 (2012) 3-26.