• Title/Summary/Keyword: Safety requirements

Search Result 1,708, Processing Time 0.027 seconds

SHIELDING ANALYSIS OF DUAL PURPOSE CASKS FOR SPENT NUCLEAR FUEL UNDER NORMAL STORAGE CONDITIONS

  • Ko, Jae-Hun;Park, Jea-Ho;Jung, In-Soo;Lee, Gang-Uk;Baeg, Chang-Yeal;Kim, Tae-Man
    • Nuclear Engineering and Technology
    • /
    • v.46 no.4
    • /
    • pp.547-556
    • /
    • 2014
  • Korea expects a shortage in storage capacity for spent fuels at reactor sites. Therefore, a need for more metal and/or concrete casks for storage systems is anticipated for either the reactor site or away from the reactor for interim storage. For the purpose of interim storage and transportation, a dual purpose metal cask that can load 21 spent fuel assemblies is being developed by Korea Radioactive Waste Management Corporation (KRMC) in Korea. At first the gamma and neutron flux for the design basis fuel were determined assuming in-core environment (the temperature, pressure, etc. of the moderator, boron, cladding, $UO_2$ pellets) in which the design basis fuel is loaded, as input data. The evaluation simulated burnup up to 45,000 MWD/MTU and decay during ten years of cooling using the SAS2H/OGIGEN-S module of the SCALE5.1 system. The results from the source term evaluation were used as input data for the final shielding evaluation utilizing the MCNP Code, which yielded the effective dose rate. The design of the cask is based on the safety requirements for normal storage conditions under 10 CFR Part 72. A radiation shielding analysis of the metal storage cask optimized for loading 21 design basis fuels was performed for two cases; one for a single cask and the other for a $2{\times}10$ cask array. For the single cask, dose rates at the external surface of the metal cask, 1m and 2m away from the cask surface, were evaluated. For the $2{\times}10$ cask array, dose rates at the center point of the array and at the center of the casks' height were evaluated. The results of the shielding analysis for the single cask show that dose rates were considerably higher at the lower side (from the bottom of the cask to the bottom of the neutron shielding) of the cask, at over 2mSv/hr at the external surface of the cask. However, this is not considered to be a significant issue since additional shielding will be installed at the storage facility. The shielding analysis results for the $2{\times}10$ cask array showed exponential decrease with distance off the sources. The controlled area boundary was calculated to be approximately 280m from the array, with a dose rate of 25mrem/yr. Actual dose rates within the controlled area boundary will be lower than 25mrem/yr, due to the decay of radioactivity of spent fuel in storage.

Quality Control System for Analytical Chemistry Laboratory of Pesticide Products (농약 이화학시험 분석기관 정도관리체계)

  • Chang, Hee-Ra;Lee, Joon-Yeob;Lee, Young-Ju;Kang, Hye-Rim;Kim, Chan-Sub;Kim, Kyun
    • The Korean Journal of Pesticide Science
    • /
    • v.15 no.4
    • /
    • pp.529-544
    • /
    • 2011
  • Many international organizations, such as the International Organization for Standardization (ISO) and Collaborative International Pesticide Analytical Council (CIPAC), have published a guide to quality control requirements, proficiency testing and method validation for pesticide formulation. In general, proficiency testing is to determine the performance of individual laboratories from the comparison of test results and to monitor a laboratory's performance abilities. One of quality assurance (QA) scheme would be include the validation of analytical method that implies a performance characteristics, specificity, selectivity, linearity and so on. According to many international organizations, the quantification methods of active substance in formulated pesticide products are required to be reproducible, accurate and precise. This study was conducted to compare the international guidelines for the quality control, proficiency testing and method validation of analytical laboratories and to propose a general guidance for the establishment of quality control system in the analytical chemistry laboratories of pesticide formulation in domestic.

Care-giver's Needs and Evaluation on the Actual Condition of the Playgrounds in Child Care Facilities (보육시설의 실외놀이 환경실태 및 환경특성에 대한 교사의 평가와 요구)

  • Choi, Mock-Wha;Byun, Hea-Ryun
    • Journal of the Korean housing association
    • /
    • v.19 no.6
    • /
    • pp.105-114
    • /
    • 2008
  • The purpose of this study is to classify playground types according to the physical characteristics of playgrounds in child care facilities, to analyze the needs of care-givers and to evaluate the adequacy of playgrounds according to playground types. The specific areas discussed in this study were the evaluation of the adequacy in the physical characteristics of playgrounds for children's outdoor play activities by the care-givers, who assist in the outdoor play activities of children and manage safety in the playground, and a report on playground requirements of them. Data was collected from field survey carried out to investigate the physical characteristics of playgrounds of 21 child care facilities. This survey incorporated a structured-questionnaire for the purpose of evaluating the adequacy of the physical characteristics of playgrounds (location and size of the playground, play equipments, the composition of play areas, ground covers, and location of sidewalk in the playground) by the 181 care-givers from the facilities and investigating the needs of them. The major results showed the following. 1) In field survey, it was observed that while the location and the size of the playgrounds varied widely, ground cover, play equipments, and the composition of play area turned out to be identical, regardless of the location and the size of the playgrounds. 2) The playgrounds were classified into five types according to the number of children and the size of the playground. The five types include A-type as a large-scale facility/smallsize playground, B-type as a small-scale facility/large-size playground, C-type as a small-scale facility/small-size playground, D-type as a middle-scale facility/large-size playground, and E-type as a large-scale facility/large-size playground. 3) The adequacy of the physical characteristics of playground in the D-type was evaluated to be higher than that of the other types. The adequacy of the C-type playground was evaluated to be lower than that of the other types in terms of size and the composition of play areas within the playground. 4) The care-givers of the D-type and the E-type playground expressed a desire to install various play equipments, while the care-givers of the C-type playground did not wish to install play equipment. 5) Various outdoor play areas were needed in the D-type playground.

Design and Implementation of Service Model for Tailored Residential Space based on 3D Cadastral Information (3차원 지적정보 기반 맞춤형 주거 공간정보 서비스 모델 개발)

  • Bae, Sang Keun;Shin, Yun Ho;Lee, Seong Gyu;Joo, Yong Jin
    • Spatial Information Research
    • /
    • v.23 no.2
    • /
    • pp.49-57
    • /
    • 2015
  • Recently, Through the linkage and opening, the fusion of the spatial information, it is necessary for productive ecosystem to provide a variety of information and to increase the civil use. Depending on the economic growth, demand for quality of life and well-being has been on the increase. Spatial information service contents for the public convenience has emerged to solve the problem such as health, safety, welfare and discomfort of daily life This study aims to implement search services for a tailored residence space through the three-dimensional data modeling on cadastral information. To achieve this goal, we established the requirements for deriving a registered object by investigating recent trend with respect to existing cadastral data model and defined property and relationship. Focusing on Songpa-gu, Jamsil station in Seoul, we implemented search services for a tailored residence space for three-dimensional right analysis in conjunction with residential and commercial complex building. As a result, we derived a way to supply 3D cadastre information through open platforms (VWorld) and to represent efficiently, which is able to improve the quality of spatial information service contents for the public convenience as well as to widen utilization of information.

Exposure Assessment of Korean Farmers While Applying Chlorpyrifos, and Chlorothalonil on Pear and Red Pepper (노지고추 및 배 재배 농업인의 방제작업 중 Chlorpyrifos, Chlorothalonil 노출에 관한 연구)

  • Kang, Tae-Sun;Kim, Gil-Joong;Choe, In-Ja;Kwon, Young-Jun;Kim, Kyung-Ran;Lee, Kyung-Sook
    • Journal of agricultural medicine and community health
    • /
    • v.29 no.2
    • /
    • pp.249-263
    • /
    • 2004
  • Objectives: The objectives of the present study were to establish the exposure monitoring method of chlorpyrifos and chlorothalonil application to pear and field red pepper by vehicle-mounted sprayer, hand-held sprayer and to assess the risk. Methods and Results: Chlorpyrifos met all of requirements of sampling and analysis method(U.S. EPA), but chlorothalonil met only dermal patch method. Potential dermal and inhalation exposure was evaluated in 42 farmers. Compared with the hand-held sprayer application, vehicle mounted sprayer demonstrated producing relatively lower dermal exposure levels with statistical significance. In dermal exposure during hand-held application, there is no significant difference between pear and red pepper. Conclusions: This results show that application method is the main factor of dermal exposure. There was no statistically significant difference between each group of respiratory exposure level. The margin of safety (MOS) was calculated to assess the risk of pesticide exposure. All Chlorpyrifos MOS values are lower than 0.2, which mean working conditions are unsafe. In order to protect farmers, big efforts to control exposure are needed.

  • PDF

Seismic Performance and Damage Prediction of Existing Fire-protection Pipe Systems Installed in RC Frame Structures (철근콘크리트 구조물 내 부착된 수계 관망시스템의 내진거동 및 손상예측)

  • Jung, Woo-Young;Ju, Bu-Seog
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.3
    • /
    • pp.37-43
    • /
    • 2011
  • Reliability of piping systems is essential to the safety of any important industrial facilities. During an earthquake, damage to the piping system can occur. It can also cause considerable economic losses and the loss of life following earthquakes. Traditionally, the study of the secondary system was less important than primary structure system, however it has recently been emerging as a key issue for the effective maintenance of the structural system and to help reduce nonstructural earthquake damage. The primary objectives of this study are to evaluate seismic design requirements and the seismic performance of gas and fire protection piping systems installed in reinforced concrete (RC) buildings. In order to characterize the seismic behavior of the existing piping system in an official building, 10 simulated earthquakes and 9 recorded real earthquakes were applied to ground level and the building system by the newmark average acceleration time history method. The results developed by this research can be used for the improvement of new seismic code/regulatory guidelines of secondary systems as well as the improvement of seismic retrofitting or the strengthening of the current piping system.

Development of the computer program calculating the stress induced by various loads for buried natural gas pipeline ( I ) (매설 천연가스 배관의 제반하중에 의한 응력 계산용 프로그램 개발 (I))

  • Bang I.W.;Kim H.S.;Kim W.S.;Yang Y.C.;Oh K.W.
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.2
    • /
    • pp.18-25
    • /
    • 1998
  • According to the requirements of ANSI B3l.8, the pipe thickness is determined with hoop stress resulted from internal pressure. And the other loads induced by soil, vehicle, thermal expansion, ground subsidence, etc shall be evaluated rationally. There are two ways of calculating stress of buried gas pipeline. The first is FEM. FEM can calculate the stress regardless of the complexity of pipeline shape and boundary conditions. But it needs high cost and long time. The second is the way to use equation. The reliable equations to calculate the stress of buried gas pipeline was developed and have been used in designing pipeline and evaluating pipeline safety, But these equation are very difficult to understand and use for non-specialist. For easy calculation of non-specialist, the new computer program to calculate stress of buried natural gas pipeline have been developed. The stress is calculated by the equations and extrapolation of the graph resulted from FEM. The full paper is consist of series I and II. In this paper, series I, the calculating equation of the program is explained in detail.

  • PDF

Development of the computer program calculating the stress induced by various loads for buried natural gas pipeline (II) (매설 천연가스 배관의 제반하중에 의한 응력 계산용 프로그램 개발 (II))

  • Bang I.W.;Kim H.S.;Yang Y.C.;Kim W.S.;Oh K.W.
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.2
    • /
    • pp.26-33
    • /
    • 1998
  • The thickness of buried gas pipeline is determined mainly with internal pressure and location factor according to the requirements of ANSI B3l.8. But the stress of buried gas pipeline is determined by not only internal stress but also external loads. The change of burying and environmental conditions, therefore, may result in increasing stress of pipeline. In order to avoid the decrease of safety degree resulting from change of environmental condition, the evaluation of stress level shall be necessary. The reliable equations have been developed for calculating stress of buried pipeline from internal pressure, earth load, vehicle load, ground subsidence. But they are very difficult to understand and use for non-specialist. For easy calculation of non-specialist, the new computer program to calculate stress of buried natural gas pipeline have been developed. The program can calculate maximum stress resulted from earth load, vehicle load, thermal load, four type ground subsidence. The stress is calculated by the equations and extrapolation of the graph resulted from FEM. In this paper, as the series of paper I, the operating method and the functions of the program is explained.

  • PDF

Development of a Prototype Patient Monitoring System with Module-Based Bedside Units and Central Stations: Overall Architecture and Specifications (모듈형 환자감시기와 중앙 환자감시기로 구성되는 환자감시시스템 시제품의 개발: 전체구조 및 사양)

  • Woo, E.J.;Park, S.H.;Jun, B.M.;Moon, C.W.;Lee, H.C.;Kim, S.T.;Kim, H.J.;Seo, J.J.;Chae, K.M.;Park, J.C.;Choi, K.H.;Lee, W.J.;Kim, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.315-319
    • /
    • 1996
  • We have developed a prototype patient monitoring system including module-based bedside units, interbed network, and central stations. A bedside unit consists of a color monitor and a main CPU unit with peripherals including a module controller. It can also include up to 3 module cases and 21 different modules. In addition to the 3-channel recorder module, six different physiological parameters of ECG, respiration, invasive blood pressure, noninvasive blood pressure, body temperature, and arterial pulse oximetry with plethysmogaph are provided as parameter modules. Modules and a module controller communicate with up to 1Mbps data rate through an intrabed network based on RS-485 and HDLC protocol. Bedside units can display up to 12 channels of waveforms with any related numeric informations simultaneously. At the same time, it communicates with other bedside units and central stations through interbed network based on 10Mbps Ethernet and TCP/IP protocol. Software far bedside units and central stations fully utilizes gaphical user interface techniques and all functions are controlled by a rotate/push button on bedside unit and a mouse on central station. The entire system satisfies the requirements of AAMI and ANSI standards in terms of electrical safety and performances. In order to accommodate more advanced data management capabilities such as 24-hour full disclosure, we are developing a relational database server dedicated to the patient monitoring system. We are also developing a clinical workstation with which physicians can review and examine the data from patients through various kinds of computer networks far diagnosis and report generation. Portable bedside units with LCD display and wired or wireless data communication capability will be developed in the near future. New parameter modules including cardiac output, capnograph, and other gas analysis functions will be added.

  • PDF

Development of a Real-time OS Based Control System for Laparoscopic Surgery Robot (복강경 수술로봇을 위한 실시간 운영체제 기반 제어 시스템의 개발)

  • Song, Seung-Joon;Park, Jun-Woo;Shin, Jung-Wook;Kim, Yun-Ho;Lee, Duk-Hee;Jo, Yung-Ho;Choi, Jae-Seoon;Sun, Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.1
    • /
    • pp.32-39
    • /
    • 2008
  • This paper reports on a realtime OS based master-slave configuration robot control system for laparoscopic surgery robot which enables telesurgery and overcomes shortcomings with conventional laparoscopic surgery. Surgery robot system requires control system that can process large volume information such as medical image data and video signal from endoscope in real-time manner, as well as precisely control the robot with high reliability. To meet the complex requirements, the use of high-level real-time OS (Operating System) in surgery robot controller is a must, which is as common as in many of modem robot controllers that adopt real-time OS as a base system software on which specific functional modules are implemened for more reliable and stable system. The control system consists of joint controllers, host controllers, and user interface units. The robot features a compact slave robot with 5 DOF (Degree-Of-Freedom) expanding the workspace of each tool and increasing the number of tools operating simultaneously. Each master, slave and Gill (Graphical User Interface) host runs a dedicated RTOS (Real-time OS), RTLinux-Pro (FSMLabs Inc., U.S.A.) on which functional modules such as motion control, communication, video signal integration and etc, are implemented, and all the hosts are in a gigabit Ethernet network for inter-host communication. Each master and slave controller set has a dedicated CAN (Controller Area Network) channel for control and monitoring signal communication with the joint controllers. Total 4 pairs of the master/slave manipulators as current are controlled by one host controller. The system showed satisfactory performance in both position control precision and master-slave motion synchronization in both bench test and animal experiment, and is now under further development for better safety and control fidelity for clinically applicable prototype.