• Title/Summary/Keyword: Safety related valve

Search Result 50, Processing Time 0.02 seconds

Transient analysis of lubrication with a squeeze film effect due to the loading rate at the interface of a motor operated valve assembly in nuclear power plants

  • Jaehyung Kim;Sang Hyuk Lee;Sang Kyo Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2905-2918
    • /
    • 2023
  • The valve assembly used in nuclear power plants is important safety-related equipment. In the new standard, the physical attributes are measured using a valve diagnosis test, which is used in the expansion to other non-tested valves using a quantitative test-basis methodology. With a motor-operated actuator, the state of stem's lubrication is related to physical attributes such as the stem factor and the friction coefficient. This study analyzed the numerical transient of fluid and solid lubrication with a squeeze film effect due to the loading rate on the stem and the stem nut using the experimental data. The differential equation that governs the motion mechanism of the stem and stem nut is established and analyzed. The flow rate, the fluid and the solid contact forces are calculated with the friction coefficient. Finally, we found that a change in the friction coefficient results from a change of the shear force in the solid contact mode during the interchange process between the solid contact mode and the fluid contact mode. The qualitative understanding of the squeeze film effect is expanded quantitatively for forces, thread surface distance, velocity, and acceleration, with consideration of the metal solid contact and fluid contact.

A Study on the Development of Overflow Cutoff Valve for Liquefied Petroleum Gas Cylinders (액화석유가스 용기용 과류차단밸브의 개발에 관한 연구)

  • Rhim Jong-Kuk
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.2 s.70
    • /
    • pp.158-161
    • /
    • 2005
  • This research is about overflow cutoff valve for liquefied petroleum gas cylinders. This valve was developed based on Bernoulli's equation and Newton's equation. The structure of overflow cutoff valve was made by insert module instead of the ordinary valve that is used at present. Recently, the increase in use of gas for fuel in houses has resulted to more frequent occurrences of gas related accidents. In Korea, the government has made a law for the obligatory use of the cutoff valves. This cutoff valve is not ya developed. This research focuses on the use of over flow cutoff valve for LPG cylinders. If this valve is adapted, many accidents can be prevented.

Shape Design Optimization of Disk Seal in $SF_6$ Gas Safety Valve ($SF_6$ 가스 안전밸브 디스크 시일의 최적설계에 관한 연구)

  • 김청균;조승현
    • Tribology and Lubricants
    • /
    • v.20 no.5
    • /
    • pp.231-236
    • /
    • 2004
  • Sulfur Hexafluoride, S $F_{6}$ is widely used for leak detection and as a gaseous dielectric in transformers, condensers and circuit breakers. S $F_{6}$ gas is also effective as a cleanser in the semiconductor industry. This paper presents a numerical study of the sealing force of disk type seal in S $F_{6}$ gas safety valve. The sealing force on the disk seal is analyzed by the FEM method based on the Taguch's experimental design technique. Disk seals in S $F_{6}$ gas safety valve are designed with 9 design models based on 3 different contact length, compressive ratio and gas pressure. The calculated results of Cauchy stress and strain showed that the sealing characteristics of Teflon $^{ }$PTFE is more effective compared to that of FKM(Viton), which is related to the stiffness of the materials. And also, the contact length of the disk seal is important design parameter for sealing the S $F_{6}$ gas leakage in the safety valve.afety valve.

Selection of Valves Susceptible to Pressure Locking and Thermal Binding (압력잠김 및 열고착 현상 발생가능 밸브의 선정)

  • Lee, Sung-No;An, Jin-Geun;Kim, Seoug-Beom
    • The KSFM Journal of Fluid Machinery
    • /
    • v.10 no.5
    • /
    • pp.20-26
    • /
    • 2007
  • Some gate valves are susceptible to pressure locking and thermal binding which prevent the safety function. The safety related gate valves susceptible to pressure locking and thermal binding shall be identified and taken preventive actions to ensure the safety function. The identification of the gate valves susceptible to pressure locking and thermal binding needs the evaluation of system design, valve and piping arrangement, test requirements, and operating conditions. Application of preventive methods should consider the system safety function, applicability, effectiveness, interface with system design, and cost. The selection procedure of valves susceptible to pressure locking and thermal binding can be effectively used in industry including nuclear power plants. In order to prevent the pressure locking, the hole can be drilled through the one disc of upstream side or down stream and the external equalizing line can be installed from bonnet to downstream or upstream. The double disc parallel seat valve type can be used instead of flexible wedge gate valve to prevent the thermal binding. The identification of gate valves susceptible to pressure locking and thermal binding, and preventive actions will meet the regulatory requirements and enhance the availability and safety of plants.

A Development of Web-based Safety Evaluation System of Motor-Operated-Valve in Nuclear Power Plant (웹기반 원전 동력구동밸브 안정성 평가 시스템 개발)

  • Bae, J.H.;Lee, K.N.;Kim, W.M.;Park, S.K.;Lee, D.H.;Kim, J.C.;Hong, J.S.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.903-908
    • /
    • 2001
  • A web-based client/server program, MOVIDIK(Motor-Operated-Valve Integrated Database Information of KEPCO) has been developed to perform a design basis safety evaluation for a motor-operated-valve(MOV) in the nuclear power plant. The MOVIDIK consists of seven analysis modules and one administrative module. The analysis module calculates a differential pressure on the valve disk, thrust/torque acting at a valve stem, maximum allowable stress, thermal-overload-relay selection, voltage degradation, actuator output and margin. In addition, the administrative module manages user information, approval system and code information. MOVIDIK controls a huge amount of evaluation data and piles up the safety information of safety-related MOV. The MOVIDIK will improve the efficiency of safety evaluation work and standardize the analysis process for the MOV.

  • PDF

Preliminary Review of On-Site Clamping Repair Technology for Welding Part Leakage of Safety Related Valve in the Nuclear Power Plant (원전용 안전등급 밸브의 용접부 누설 클램핑 현장보수 기술 검토)

  • Ki Hong Kim;Ki Su Kim;Hwan Seok Jung;Moo Kyung Jang
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.19 no.1
    • /
    • pp.52-59
    • /
    • 2023
  • The welding part of the valve needs immediate action when leakage occurs due to cracks or damage. In order to repair leakage of the welding part, the valve must be separated from the pipe or replaced with a new valve. However, it is difficult to remove the valve while operating the power plant. This study presents a method to remove leakage by precisely processing the gap between the clamp and the incision part within 0.1mm while installed in the pipe system. If the external leakage is removed using a clamp on the welding part without removing the valve during operation, the time and cost required for maintenance can be reduced.

Shape Design of Disk Seal in $SF_6$ Gas Safety Valve using Taguchi method (다구찌법을 이용한 $SF_6$가스 안전밸브용 디스크 시일 형상의 설계)

  • Cho Seunghyun;Kim Chungkyun;Kim Younggyu
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.237-240
    • /
    • 2004
  • Sulfur Hexafluoride, SF6 is widely used for leak detection and as a gaseous dielectric in transformers, condensers and circuit breakers. SF6 gas is also effective as a cleanser in the semiconductor industry. This paper presents a numerical study of the sealing force of disk type seal in SF6 gas safety valve. The sealing force on the disk seal is analyzed by the FEM method based on the Taguch's experimental design technique. Disk seals in SF6 gas safety valve are designed with 9 design models based on 3 different contact length, compressive ratio and gas pressure. The calculated results of Cauchy stress and strain showed that the sealing characteristics of Teflon PTFE is more effective compared to that of FKM(Viton), which is related to the stiffness of the materials. And also, the contact length of the disk seal is important design parameter for sealing the SF6 gas leakage in the safety valve.

  • PDF

Analysis for the Behavior of Thermal Stratification in Safety Injection Piping of Nuclear Power Plant (원전 안전주입배관에서의 열성층 유동해석)

  • Park, M.H.;Kim, K.K.;Youm, H.K.;Kim, T.Y.;Lee, S.K.;Kim, K.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.110-114
    • /
    • 2001
  • A numerical analysis has been perfonned to estimate the effect of turbulent penetration and thermal stratified flow in the branch lines piping. This phenomenon of thermal stratification are usually observed in the piping lines of the safety related systems and may be identified as the source of fatigue in the piping system due to the thermal stress loading which are associated with plant operating modes. The turbulent penetration length reaches to $1^{st}$ valve in safety injection piping from reactor coolant system (RCS) at normal operation for nuclear power plant when a coolant does not leak out through valve. At the time, therefore, the thermal stratification does not appear in the piping between RCS piping and $1^{st}$ valve of safety injection piping. When a coolant leak out through the $1^{st}$ valve by any damage, however, the thermal stratification can occur in the safety injection piping. At that time, the maximum temperature difference of fluid between top and bottom in the piping is estimated about $50^{\circ}C$.

  • PDF

Categorization of Motor Operated Valve Safety Significance for Its Periodic Safety Verification (모터구동 밸브 주기적 안전성 확인을 위한 중요도 분류)

  • Sung, Tae-Young;Kim, Kil-Yoo;Kang, Dae-Il
    • Journal of the Korean Society of Safety
    • /
    • v.17 no.2
    • /
    • pp.92-99
    • /
    • 2002
  • Safety-related motor operated valve(MOV) safety significance for Ulchin Unit 3 was categorized. The safety evaluation of MOV of domestic nuclear power plants affects the generic data used for the quantification of MOV common cause failure(CCF) events in Ulchin Units 3&4 PSA. Therefore, in this paper, MGL(multiple greek letter)parameter ${\beta}$, used for the evaluation of MOV CCF probabilities in Ulchin Units 3&4 probabilistic safety assessment(PSA), was re-estimated and the MOV safety significance was categorized. The re-estimation results of MGL parameter show that the value of(is decreased by 30% compared with the current value used in Ulchin Unit 3&4 PSA. The categorization results of MOV safety significance using the changed value of MGL parameter(show that the number of HSSCs(high safety significant components) is decreased by 54.5% compared with those using the current value of it used in Ulchin Units 3&4 PSA.

Experimental Investigation on Cracks and Defects of a Valve Sealing Components for a LPG Cylinder (LPG 용기용 밸브의 밀봉부품 크랙 및 결함에 관한 실험적 고찰)

  • Kim, Chung-Kyun;Lee, Byung-Kwan;Kim, Tae-Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.11 no.1 s.34
    • /
    • pp.23-28
    • /
    • 2007
  • This paper presents an experimental investigation on the sealing defects and cracks of O-rings and a valve packing of a gas valve for a LPG cylinder. O-ring in which stops a gas leakage of a liquefied petroleum gas is very important for a LPG valve safety. Valve packing is to open and close a gas flow port for supplying and charging a LPG fuel. The sealing performance of two sealing units ism related to the leak safety and long lift of a gas valve. The investigated results show that most of O-rings was failed due to a circumferential crack in which is caused by partial press bonding failure near the partition zone and an excess compression rate. Some of the O-ring failure was originated by an extrusion of an excessive leak pressure of a LP gas. Thus, this paper strongly recommends a tight quality control and a safety guarantee system of O-rings and valve packing to guarantee a leak safety and to extend a service lift of a gas valve. At the end, a warranty policy of the sealing units should be adopted for increasing a product quality and safety of a gas valve.

  • PDF