• Title/Summary/Keyword: Safety and protection

Search Result 2,764, Processing Time 0.028 seconds

The Study on the Fire Monitoring Dystem for Full-scale Surveillance and Video Tracking (전방위 감시와 영상추적이 가능한 화재감시시스템에 관한 연구)

  • Baek, Dong-hyun
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.40-45
    • /
    • 2018
  • The omnidirectional surveillance camera uses the object detection algorithm to level the object by unit so that broadband surveillance can be performed using a fisheye lens and then, it was a field experiment with a system composed of an omnidirectional surveillance camera and a tracking (PTZ) camera. The omnidirectional surveillance camera accurately detects the moving object, displays the squarely, and tracks it in close cooperation with the tracking camera. In the field test of flame detection and temperature of the sensing camera, when the flame is detected during the auto scan, the detection camera stops and the temperature is displayed by moving the corresponding spot part to the central part of the screen. It is also possible to measure the distance of the flame from the distance of 1.5 km, which exceeds the standard of calorific value of 1 km 2,340 kcal. In the performance test of detecting the flame along the distance, it is possible to be 1.5 km in width exceeding $56cm{\times}90cm$ at a distance of 1km, and so it is also adaptable to forest fire. The system is expected to be very useful for safety such as prevention of intrinsic or surrounding fire and intrusion monitoring if it is installed in a petroleum gas storage facility or a storing place for oil in the future.

A Study on the Evaluation for Performance of Body Armor Vest using ANOVA (분산분석을 이용한 방탄조끼의 방탄성능 평가에 관한 연구)

  • Park, Jae Woo;Byun, Kisik;Cho, Sung-Yong;Kim, Suk Ki;Yeo, Yongheon;Kwon, Jae Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.372-378
    • /
    • 2021
  • A body armor vest is a form of munition related directly to the safety and life of combatants. Therefore, it must meet the requirements for ballistic resistance. The ROK demands the performance of body armor vest meet the Level IIIA specified by the NIJ STD-0101.06 published by the US National Institute of Justice. This study performed acceptance tests on body armor vests. The factors for evaluating the ballistic resistance evaluated were not only whether it penetrates when shooting but also whether the BFS (Backface Signature) depth does not exceed 44 mm when it does not penetrate. The factors were assessed to determine if they were consistent or not. The BFS depth is affected by various test factors, such as the physical properties of the backing material and the changes in the amount of impact with the bullet velocity. In this study, an analysis of the bulletproof performance was performed by extracting the data with the same conditions using ANOVA to remove the influence of these external factors. The analysis revealed a correlation between the BFS depth, bullet velocity, vest conditions, and protection area. The mass production process was analyzed by estimating the Interval of BFS on each lot. Through this, a new methodology for ballistic resistance evaluation and paradigm for future quality assurance is suggested.

Assessment of physical condition of old large Chionanthus retusus(Chinese Fringe Tree) using structural stability analysis (천연기념물 이팝나무 노거수 구조안정성 진단을 통한 물리적 생육상태 평가)

  • SON Jiwon;SHIN Jinho
    • Korean Journal of Heritage: History & Science
    • /
    • v.56 no.1
    • /
    • pp.118-130
    • /
    • 2023
  • Decay or large cavities inside trees are the main causes of trees overturning and broken branches, and structurally weakened trees are more vulnerable to strong winds and heavy snowfall. Recently, as strong winds and typhoons increase due to climate change, the damage to human life and property due to trees overturning continues to increase, and cultural assets are in a similar situation. In particular, old big trees are structurally vulnerable to external shocks such as strong winds and heavy snowfall. This study was aimed at providing a scientific basis for preventive protection measures by conducting a structural stability diagnosis of seven retusa fringe trees designated as natural monuments. For the structural stability diagnosis, tree risk assessment and internal tree defect measurements were performed. As a result of the tree risk assessment, the Retusa Fringe Trees in Sinjeon-ri, Yangsan and Gwangyangeupsu had the highest risk of broken branches due to weak branch attachment strength. As a result of the diagnosis of internal defects of cross sections of measured trees, there were suspected cavities or severe decay in all except two trees of the population of Retusa Fringe Trees in Pyeongji-ri. Natural disasters due to climate change are increasing, and the scale is getting larger, so it is very important to preemptively manage large old trees through scientific structural safety diagnosis to manage trees that are vulnerable to environmental changes.

Assaying Mitochondrial COI Sequences and Their Molecular Studies in Hexapoda, PART I: From 2000 to 2009 (육각강에서 보고된 미토콘드리아 COI 염기서열과 이들을 이용한 분자 연구 논문 분석, 파트 I: 2000년~2009년)

  • Lee, Wonhoon;Park, Jongsun;Akimoto, Shin-Ichi;Kim, Sora;Kim, Yang-Su;Lee, Yerim;Kim, Kwang-Ho;Lee, Si Hyeock;Lee, Yong-Hwan;Lee, Seunghwan
    • Korean journal of applied entomology
    • /
    • v.52 no.4
    • /
    • pp.395-402
    • /
    • 2013
  • Since 2000, a large number of molecular studies have been conducted in Hexapoda with generating large amount of mitochondrial sequences. In this study, to review mitochondrial COI sequences and their molecular studies reported in Hexapoda from 2000 to 2009, 488 molecular studies conducted based on 58,323 COI sequences were categorized according to 26 orders and the positions of COI sequences (5', 3', and entire regions). The numbers of molecular studies in which the three regions utilized varied largely among the 26 orders; however, seven orders showed preferred positions of COI sequences in the researches: Diptera and Orthoptera revealed the largest number of studies in the 5' region; while, Coleoptera, Phthiraptera, Odonata, Phasmatodea, and Psocoptera, showed the largest number of studies in the 3' region. From comparing 84 molecular studies published before 2000, we observed the possibilities that molecular studies in Coleoptera, Diptera, Phthiraptera, and Phasmatodea from 2000 to 2009 had been followed classical studies using the positions of COI sequences well-known until 1999. This study provides useful information to understand the overall trends in COI sequence usages as well as molecular studies conducted from 2000 to 2009 in Hexapoda.

Shielding Design Optimization of the HANARO Cold Neutron Triple-Axis Spectrometer and Radiation Dose Measurement (냉중성자 삼축분광장치의 차폐능 최적화 설계 및 선량 측정)

  • Ryu, Ji Myung;Hong, Kwang Pyo;Park, J.M. Sungil;Choi, Young Hyeon;Lee, Kye Hong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.21-29
    • /
    • 2014
  • A new cold neutron triple-axis spectrometer (Cold-TAS) was recently constructed at the 30 MWth research reactor, HANARO. The spectrometer, which is composed of neutron optical components and radiation shield, required a redesign of the segmented monochromator shield due to the lack of adequate support of its weight. To shed some weight, lowering the height of the segmented shield was suggested while adding more radiation shield to the top cover of the monochromator chamber. To investigate the radiological effect of such change, we performed MCNPX simulations of a few different configurations of the Cold-TAS monochromator shield and obtained neutron and photon intensities at 5 reference points just outside the shield. Reducing the 35% of the height of the segmented shield and locating lead 10 cm from the bottom of the top cover made of polyethylene was shown to perform just as well as the original configuration as radiation shield excepting gamma flux at two points. Using gamma map by MCNPX, it was checked that is distribution of gamma. Increased flux had direction to the top and it had longer distance from top of segmented shield. However, because of reducing the 35% of the height, height of dissipated gamma was lower than original geometry. Reducing the 35% of the height of the segmented shield and locating lead 10cm from the bottom of the top cover was selected. After changing geometry, radiation dose was measured by TLD for confirming tester's safety at any condition. Neutron(0.21 ${\mu}Svhr^{-1}$) and gamma(3.69 ${\mu}Svhr^{-1}$) radiation dose were satisfied standard(6.25 ${\mu}Svhr^{-1}$).

A Study on the Development of Fire Extinguishing Agent and Extinguishing System for ESS Fire (ESS 화재전용 소화약제 및 소화시스템 개발에 관한 연구)

  • Lee, Yeon-Ho;Lee, Joo-Hyung;Kim, Soo-Jin;Chon, Sung-Ho;Choi, Byoung-Chul;Oh, Seung-Ju;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.147-155
    • /
    • 2020
  • This paper presents a study on the development of a fire extinguishing agent and extinguishing system for an energy storage system (ESS) fire. The fire extinguishing agent designed to extinguish an ESS fire is a highly permeable fire extinguisher that reduces the surface tension and viscosity while bringing about cooling action. This is the main extinguishing effect of this type of wetting agent, which displays the characteristics of fire extinguishing agents used for penetrating the battery cells inside the ESS module. For the fire extinguishing system, a local application system was designed to suppress fire on a rack-by-rack basis. A 360° rotating nozzle was inserted into the rear hall of the ESS module, and general nozzles were installed in the rack to maximize the fire extinguishing effect. The fire extinguishing agent was strongly discharged by virtue of the gas release pressure. Experiments on fire suppression performance with ESS module 1 unit and module 3 units showed that all visible flames were extinguished in 8 s and 9 s, respectively, by the fire extinguishing agent. In addition, based on confirming reignition for 600 s after the fire extinguishing agent was exhausted, it was confirmed that the ESS fire was completely extinguished without reignition in all fire suppression performance experiments.

Collision Strength Assessment for Double Hull Type Product Carrier Using Finite Element Analysis (이중 선체 화학 운반선의 충돌 강도 평가)

  • Paik, Jeom-Kee;Lee, Jae-Myung;Lee, Kyung-Ern;Won, Suk-Hee;Kim, Chelo-Hong;Ko, Jae-Yong
    • Journal of Navigation and Port Research
    • /
    • v.28 no.6
    • /
    • pp.481-489
    • /
    • 2004
  • Ship collisions and grounding continue to occur regardless of continuous efforts to prevent such accidents. With the increasing demand for safety at sea and for protection of the environment, it is of crucial importance to be able to reduce the probability of accidents, assess their consequences and ultimately minimize or prevent potential damages to the ships and the marine environment. Numerical simulations for actual collision problem are conducted with a special attention with respect to finite element size, fracture criteria and material properties, which require a careful consideration to improve the accuracy. A parametric analysis varying colliding speed, angle, design loading condition is conducted using nonlinear finite element analysis method for 46,00 dwt Product/chemical carrier. The relationship between the absorbed energy and indentation are derived quantitatively using the insights observed from this study, and a novel design concept for assessing the anti-collision performance are proposed.

Monitoring of pesticide residues in water and soil at the Bokpocheon watershed in Yangpyong (남한강지류 복포천유역의 농약잔류량 조사)

  • Park, Kyung-Hun;Park, Byung-Joo;Lee, Byung-Moo;Choi, Ju-Hyeon;Kim, Chan-Sub;Jeong, Mi-Hye;Kim, Byung-Seok;Park, Hyeon-Ju
    • The Korean Journal of Pesticide Science
    • /
    • v.11 no.4
    • /
    • pp.230-237
    • /
    • 2007
  • This study was carried out to indicate the status of agricultural environment in Yangpyong area which is special protection area for tap water in Han river during three years($1996{\sim}1998$). The main study was on pesticide monitoring, analysis of pesticides in Bokpocheon water and soil. Water in this small river for supplying to the rice was found nine pesticides residues, ranged from 0.1 to 22.7 ppb, similar patterns from survey conducted in National Institute of Agricultural Science and technology, Soil in rice paddy has also low levels of eleven pesticide residues, ranged from 0.002 to 0.55 ppm.

Inhibitory Effects of Candidate Probiotic Bacteria on the Growth of Fish Pathogenic Bacteria, Streptococcus sp. (Candidate Probiotic Bacteria의 어류병원성 Streptococcus sp. 성장에 대한 억제 효과)

  • Lee, Minyeong;Kim, Eunheui
    • Journal of fish pathology
    • /
    • v.27 no.2
    • /
    • pp.107-114
    • /
    • 2014
  • For the treatments and protection of bacterial fish disease, many requirements are needed for aquatic probiotics so that they are effective in aquaculture animals but are also harmless to humans. In the present study, among 17 candidate probiotic bacteria (CPB) obtained from the edible part of the shellfish, Bacillus sp. CPB-St (CPB-St) were selected and in vitro evaluated for the possibility as a probiotic strain for the control of fish streptococcosis which frequently occurs in the olive flounder farms. CPB-St showed inhibitory effects on the growth of various fish pathogenic bacteria, Streptococcus sp., S. parauberis, S. iniae, Lactococcus garvieae and L. piscium by the double layer test ranging about 18~26 mm of clear zone. Inhibitory activity of CPB-St to Streptococcus sp. was observed 6 hours after and the growth of Streptococcus sp. was decreased to 8~55 folds in the co-culture of CPB-St with Streptococcus sp.. The safety of CPB-St to fish and survival of CPB-St in the intestine were assessed in the olive flounder, Paralichthys olivaceus. Fish mortality was not observed in artificial infection with CPB-St for 2 weeks. CPB-St was entirely excreted from the stomach and intestine 24 hours after oral injection. This results indicate that CPB-St has potential applications as a probiotic for the control of fish streptococcosis in aquaculture.

Assessment of the Combustion Diffusion Pattern and Fire Risk of a Water Purifier Damaged by a General Fire (일반화염에 의해 소손된 정수기의 연소 확산 패턴 및 화재위험성 평가)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.35-39
    • /
    • 2012
  • This paper analyzes the combustion diffusion pattern when a water purifier is artificially ignited outside and inside in order to provide data to examine the cause of fire of a water purifier damaged by fire. The analysis result of the combustion diffusion pattern of a water purifier shows that the combustion diffused at a higher speed when it was ignited inside the purifier than when ignited outside. It took approximately 360 seconds for the water purifier to be half-burned when ignited on the outside, and approximately 180 seconds when ignited from inside. That is, it is thought that the internal combustion speed is higher because the internal ignition causes the generated heat to be accumulated and radiated instantly. It was observed that the water purifier damaged by fire caused by external ignition showed a uniform carbonization pattern and the carbide burned down at the bottom were gradually deposited. The water purifier damaged by internal ignition showed a relatively clear boundary of carbonized surface, which formed a V-pattern. The difference in the combustion patterns presents an objective base from which to determine where the fire started. By the time the purifier was half-burned by fire, the built-in fuse had not melted and the power supply protection device did not operate. In addition, as was found in the case of the fuse damaged by a general fire, carbonization occurred at the metal holder, and it is thought that this fact may be used as a basis from which to determine the cause of a fire.